-
1
-
-
41949113224
-
Sources of error in intraocular lens power calculation
-
DOI 10.1016/j.jcrs.2007.10.031, PII S0886335007020470
-
S. Norrby Sources of error in intraocular lens power calculation J Cataract Refract Surg 34 2008 368 376 (Pubitemid 351625583)
-
(2008)
Journal of Cataract and Refractive Surgery
, vol.34
, Issue.3
, pp. 368-376
-
-
Norrby, S.1
-
2
-
-
0021679032
-
A comparison of immersion and contact techniques for axial length measurements
-
H.J.F. Shammas A comparison of immersion and contact techniques for axial length measurements Am Intra-Ocular Implant Soc J 10 1984 444 447
-
(1984)
Am Intra-Ocular Implant Soc J
, vol.10
, pp. 444-447
-
-
Shammas, H.J.F.1
-
3
-
-
0022601055
-
MESSUNG DER BULBUSLANGE MIT VERSCHIEDENEN ULTRASCHALL-GERATEN
-
L.G. Artaria Messung der Bulbuslänge mit verschiedenen Ultraschall-Geräten [Axial length measurements with different ultrasonic devices] Klin Monatsbl Augenheilkd 188 1986 492 494 (Pubitemid 16122019)
-
(1986)
Klinische Monatsblatter fur Augenheilkunde
, vol.188
, Issue.5
, pp. 492-494
-
-
Artaria, L.G.1
-
4
-
-
0024315421
-
Comparison of contact and immersion techniques for axial length measurement and implant power calculation
-
J. Schelenz, and J. Kammann Comparison of contact and immersion techniques for axial measurement and implant power calculation J Cataract Refract Surg 15 1989 425 428 (Pubitemid 19193480)
-
(1989)
Journal of Cataract and Refractive Surgery
, vol.15
, Issue.4
, pp. 425-428
-
-
Schelenz, J.1
Kammann, J.2
-
5
-
-
0024539797
-
Immersion versus contact technique in the measurement of axial length by ultrasound
-
T. Olsen, and P.J. Nielsen Immersion versus contact technique in the measurement of axial length by ultrasound Acta Ophthalmol (Copenh) 67 1989 101 102 (Pubitemid 19110462)
-
(1989)
Acta Ophthalmologica
, vol.67
, Issue.1
, pp. 101-102
-
-
Olsen, T.1
Nielsen, P.J.2
-
6
-
-
17944377092
-
Contact or immersion technique for axial length measurement?
-
DOI 10.1046/j.1440-1606.1999.00162.x
-
A. Watson, and R. Armstrong Contact or immersion technique for axial length measurement? Aust N Z J Ophthalmol 27 1999 49 51 Available at: http://onlinelibrary.wiley.com/doi/10.1046/j.1440-1606.1999.00162.x/pdf Accessed June 30, 2011 (Pubitemid 29166667)
-
(1999)
Australian and New Zealand Journal of Ophthalmology
, vol.27
, Issue.1
, pp. 49-51
-
-
Watson, A.1
Armstrong, R.2
-
7
-
-
37349054139
-
Reply: Pentacam keratometry and IOL power calculation
-
DOI 10.1016/j.jcrs.2007.11.012, PII S0886335007019177
-
E. Borasio Pentacam keratometry and IOL power calculation [reply to letter by S Norrby] J Cataract Refract Surg 34 2008 4 (Pubitemid 350299799)
-
(2008)
Journal of Cataract and Refractive Surgery
, vol.34
, Issue.1
, pp. 4
-
-
Borasio, E.1
-
8
-
-
37349056419
-
Anterior segment biometry with the Pentacam: Comprehensive assessment of repeatability of automated measurements
-
DOI 10.1016/j.jcrs.2007.09.013, PII S0886335007017725
-
H. Shankar, D. Taranath, C. Santhirathelagan, and K. Pesudovs Anterior segment biometry with the Pentacam: comprehensive assessment of repeatability of automated measurements J Cataract Refractive Surg 34 2008 103 113 (Pubitemid 350299777)
-
(2008)
Journal of Cataract and Refractive Surgery
, vol.34
, Issue.1
, pp. 103-113
-
-
Shankar, H.1
Taranath, D.2
Santhirathelagan, C.T.3
Pesudovs, K.4
-
9
-
-
58949101631
-
Scheimpflug photography keratometry readings for routine intraocular lens power calculation
-
H.J. Shammas, K.J. Hoffer, and M.C. Shammas Scheimpflug photography keratometry readings for routine intraocular lens power calculation J Cataract Refract Surg 35 2009 330 334
-
(2009)
J Cataract Refract Surg
, vol.35
, pp. 330-334
-
-
Shammas, H.J.1
Hoffer, K.J.2
Shammas, M.C.3
-
10
-
-
78751555817
-
Automated keratometry in routine cataract surgery: Comparison of Scheimpflug and conventional values
-
R.J. Symes, and P.G. Ursell Automated keratometry in routine cataract surgery: comparison of Scheimpflug and conventional values J Cataract Refract Surg 37 2011 295 301
-
(2011)
J Cataract Refract Surg
, vol.37
, pp. 295-301
-
-
Symes, R.J.1
Ursell, P.G.2
-
11
-
-
67649831608
-
Accuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery
-
Q. Tang, K.J. Hoffer, M.D. Olson, and K.M. Miller Accuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery J Cataract Refract Surg 35 2009 1198 1203
-
(2009)
J Cataract Refract Surg
, vol.35
, pp. 1198-1203
-
-
Tang, Q.1
Hoffer, K.J.2
Olson, M.D.3
Miller, K.M.4
-
12
-
-
33751325375
-
Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula
-
DOI 10.1016/j.jcrs.2006.08.037, PII S0886335006011837
-
E. Borasio, J. Stevens, and G.T. Smith Estimation of the true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula J Cataract Refract Surg 32 2006 2004 2014 (Pubitemid 44809598)
-
(2006)
Journal of Cataract and Refractive Surgery
, vol.32
, Issue.12
, pp. 2004-2014
-
-
Borasio, E.1
Stevens, J.2
Smith, G.T.3
-
13
-
-
77953660052
-
Scheimpflug keratometry versus conventional automated keratometry in routine cataract surgery
-
erratum 2011; 37:980
-
R.J. Symes, M.J. Say, and P.G. Ursell Scheimpflug keratometry versus conventional automated keratometry in routine cataract surgery J Cataract Refract Surg 36 2010 1107 1114 erratum 2011; 37:980
-
(2010)
J Cataract Refract Surg
, vol.36
, pp. 1107-1114
-
-
Symes, R.J.1
Say, M.J.2
Ursell, P.G.3
-
14
-
-
72049102346
-
Reply to letter Holladay JT. Accuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery
-
Q. Tang, K.J. Hoffer, M.D. Olson, and K.M. Miller [Reply to letter Holladay JT. Accuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery] J Cataract Refract Surg 36 2010 183 184
-
(2010)
J Cataract Refract Surg
, vol.36
, pp. 183-184
-
-
Tang, Q.1
Hoffer, K.J.2
Olson, M.D.3
Miller, K.M.4
-
15
-
-
70350776593
-
Cleaning up data and running preliminary analyses
-
F.T.L. Leong, J.T. Austin, 2nd ed Sage Inc Thousand Oaks, CA
-
D.L. DiLalla, and S.J. Dollinger Cleaning up data and running preliminary analyses F.T.L. Leong, J.T. Austin, The Psychology Research Handbook; A Guide for Graduate Students and Research Assistants 2nd ed 2006 Sage Inc Thousand Oaks, CA 241 253
-
(2006)
The Psychology Research Handbook; A Guide for Graduate Students and Research Assistants
, pp. 241-253
-
-
Dilalla, D.L.1
Dollinger, S.J.2
-
16
-
-
67649803385
-
Accuracy of Scheimpflug corneal power measurements for intraocular lens power calculation
-
erratum, 1483
-
G. Savini, P. Barboni, M. Carbonelli, and K.J. Hoffer Accuracy of Scheimpflug corneal power measurements for intraocular lens power calculation J Cataract Refract Surg 35 2009 1193 1197 erratum, 1483
-
(2009)
J Cataract Refract Surg
, vol.35
, pp. 1193-1197
-
-
Savini, G.1
Barboni, P.2
Carbonelli, M.3
Hoffer, K.J.4
-
17
-
-
37349064395
-
Pentacam keratometry and IOL power calculation
-
DOI 10.1016/j.jcrs.2007.08.015, PII S088633500701396X
-
S. Norrby Pentacam keratometry and IOL power calculation [letter] J Cataract Refract Surg 34 2008 3 (Pubitemid 350299762)
-
(2008)
Journal of Cataract and Refractive Surgery
, vol.34
, Issue.1
, pp. 3
-
-
Norrby, S.1
|