메뉴 건너뛰기




Volumn 34, Issue 5, 2011, Pages 1037-1044

Improved quantification of brain perfusion using FAIR with active suppression of superior tagging (FAIR ASST)

Author keywords

arterial spin labeling (ASL); cerebral blood flow (CBF); FAIR; FAIR ASST; Q2TIPS

Indexed keywords

ADULT; ARTICLE; ARTIFACT; BRAIN BLOOD FLOW; BRAIN PERFUSION; BRAIN REGION; FAIR WITH ACTIVE SUPPRESSION OF SUPERIOR TAGGING TECHNIQUE; FLOW SENSITIVE ALTERNATING INVERSION TECHNIQUE; HUMAN; HUMAN EXPERIMENT; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; Q2TIPS TECHNIQUE; QUANTITATIVE ANALYSIS; QUIPPS TECHNIQUE; RADIOFREQUENCY; SPIN LABELING;

EID: 80054769768     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.22734     Document Type: Article
Times cited : (4)

References (21)
  • 1
    • 0029151256 scopus 로고
    • Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping
    • Kim SG,. Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping. Magn Reson Med 1995; 34: 293-301.
    • (1995) Magn Reson Med , vol.34 , pp. 293-301
    • Kim, S.G.1
  • 2
    • 34247868862 scopus 로고    scopus 로고
    • FAIR-TrueFISP imaging of cerebral perfusion in areas of high magnetic susceptibility differences at 1.5 and 3 Tesla
    • DOI 10.1002/jmri.20893
    • Boss A, Martirosian P, Klose U, Nagele T, Claussen CD, Schick F,. FAIR-TrueFISP imaging of cerebral perfusion in areas of high magnetic susceptibility differences at 1.5 and 3 Tesla. J Magn Reson Imaging 2007; 25: 924-931. (Pubitemid 46697561)
    • (2007) Journal of Magnetic Resonance Imaging , vol.25 , Issue.5 , pp. 924-931
    • Boss, A.1    Martirosian, P.2    Klose, U.3    Nagele, T.4    Claussen, C.D.5    Schick, F.6
  • 3
    • 0347634472 scopus 로고    scopus 로고
    • TurboFLASH FAIR Imaging with Optimized Inversion and Imaging Profiles
    • DOI 10.1002/mrm.10674
    • Pell GS, Lewis DP, Ordidge RJ, Branch CA,. TurboFLASH FAIR imaging with optimized inversion and imaging profiles. Magn Reson Med 2004; 51: 46-54. (Pubitemid 38095701)
    • (2004) Magnetic Resonance in Medicine , vol.51 , Issue.1 , pp. 46-54
    • Pell, G.S.1    Lewis, D.P.2    Ordidge, R.J.3    Branch, C.A.4
  • 4
  • 5
    • 0032904710 scopus 로고    scopus 로고
    • Transfer insensitive labeling technique (TILT): Application to multislice functional perfusion imaging
    • DOI 10.1002/(SICI)1522-2586(199903)9:3<454::AID-JMRI14>3.0.CO;2-B
    • Golay X, Stuber M, Pruessmann KP, Meier D, Boesiger P,. Transfer insensitive labeling technique (TILT): application to multislice functional perfusion imaging. J Magn Reson Imaging 1999; 9: 454-461. (Pubitemid 29180141)
    • (1999) Journal of Magnetic Resonance Imaging , vol.9 , Issue.3 , pp. 454-461
    • Golay, X.1    Stuber, M.2    Pruessmann, K.P.3    Meier, D.4    Boesiger, P.5
  • 6
    • 0030725989 scopus 로고    scopus 로고
    • Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling
    • Wong EC, Buxton RB, Frank LR,. Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling. NMR Biomed 1997; 10: 237-249. (Pubitemid 27519924)
    • (1997) NMR in Biomedicine , vol.10 , Issue.4-5 , pp. 237-249
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 7
    • 0031724562 scopus 로고    scopus 로고
    • EPISTAR MRI: Multislice mapping of cerebral blood flow
    • Edelman RR, Chen Q,. EPISTAR MRI: multislice mapping of cerebral blood flow. Magn Reson Med 1998; 40: 800-805. (Pubitemid 28543829)
    • (1998) Magnetic Resonance in Medicine , vol.40 , Issue.6 , pp. 800-805
    • Edelman, R.R.1    Chen, Q.2
  • 8
    • 33646443932 scopus 로고    scopus 로고
    • Quantitative lung perfusion mapping at 0.2 T using FAIR True-FISP MRI
    • Martirosian P, Boss A, Fenchel M, et al. Quantitative lung perfusion mapping at 0.2 T using FAIR True-FISP MRI. Magn Reson Med 2006; 55: 1065-1074.
    • (2006) Magn Reson Med , vol.55 , pp. 1065-1074
    • Martirosian, P.1    Boss, A.2    Fenchel, M.3
  • 9
    • 22744443729 scopus 로고    scopus 로고
    • Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements
    • DOI 10.1002/mrm.20580
    • Gunther M, Oshio K, Feinberg DA,. Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements. Magn Reson Med 2005; 54: 491-498. (Pubitemid 41033572)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.2 , pp. 491-498
    • Gunther, M.1    Oshio, K.2    Feinberg, D.A.3
  • 11
    • 0033936617 scopus 로고    scopus 로고
    • Noise reduction in 3D perfusion imaging by attenuating the static signal in arterial spin tagging (ASSIST)
    • DOI 10.1002/1522-2594(200007)44:1<92::AID-MRM14>3.0.CO;2-M
    • Ye FQ, Frank JA, Weinberger DR, McLaughlin AC,. Noise reduction in 3D perfusion imaging by attenuating the static signal in arterial spin tagging (ASSIST). Magn Reson Med 2000; 44: 92-100. (Pubitemid 30439843)
    • (2000) Magnetic Resonance in Medicine , vol.44 , Issue.1 , pp. 92-100
    • Ye, F.Q.1    Frank, J.A.2    Weinberger, D.R.3    McLaughlin, A.C.4
  • 12
    • 0031966050 scopus 로고    scopus 로고
    • Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
    • DOI 10.1002/mrm.1910390506
    • Wong EC, Buxton RB, Frank LR,. Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II). Magn Reson Med 1998; 39: 702-708. (Pubitemid 28189141)
    • (1998) Magnetic Resonance in Medicine , vol.39 , Issue.5 , pp. 702-708
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 13
    • 0032997648 scopus 로고    scopus 로고
    • 1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling
    • DOI 10.1002/(SICI)1522-2594(199906)41:6<1246::AID-MRM22>3.0.CO;2-N
    • Luh WM, Wong EC, Bandettini PA, Hyde JS,. QUIPSS II with thin-slice TI1 periodic saturation: a method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling. Magn Reson Med 1999; 41: 1246-1254. (Pubitemid 29247294)
    • (1999) Magnetic Resonance in Medicine , vol.41 , Issue.6 , pp. 1246-1254
    • Luh, W.-M.1    Wong, E.C.2    Bandettini, P.A.3    Hyde, J.S.4
  • 14
    • 28444475831 scopus 로고    scopus 로고
    • Quantification of cerebral perfusion using arterial spin labeling: Two-compartment models
    • DOI 10.1002/jmri.20456
    • Parkes LM,. Quantification of cerebral perfusion using arterial spin labeling: two-compartment models. J Magn Reson Imaging 2005; 22: 732-736. (Pubitemid 41741239)
    • (2005) Journal of Magnetic Resonance Imaging , vol.22 , Issue.6 , pp. 732-736
    • Parkes, L.M.1
  • 15
    • 28444471547 scopus 로고    scopus 로고
    • Quantifying CBF with arterial spin labeling
    • DOI 10.1002/jmri.20462
    • Buxton RB,. Quantifying CBF with arterial spin labeling. J Magn Reson Imaging 2005; 22: 723-726. (Pubitemid 41741237)
    • (2005) Journal of Magnetic Resonance Imaging , vol.22 , Issue.6 , pp. 723-726
    • Buxton, R.B.1
  • 18
    • 0027936294 scopus 로고
    • Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency
    • Edelman RR, Siewert B, Darby DG, et al. Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency. Radiology 1994; 192: 513-520. (Pubitemid 24233937)
    • (1994) Radiology , vol.192 , Issue.2 , pp. 513-520
    • Edelman, R.R.1    Siewert, B.2    Darby, D.G.3    Thangaraj, V.4    Nobre, A.C.5    Mesulam, M.M.6    Warach, S.7
  • 19
    • 57149104587 scopus 로고    scopus 로고
    • Continuous flow-driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields
    • Dai W, Garcia D, de Bazelaire C, Alsop DC,. Continuous flow-driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields. Magn Reson Med 2008; 60: 1488-1497.
    • (2008) Magn Reson Med , vol.60 , pp. 1488-1497
    • Dai, W.1    Garcia, D.2    De Bazelaire, C.3    Alsop, D.C.4
  • 20
    • 35948969225 scopus 로고    scopus 로고
    • A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling
    • DOI 10.1002/mrm.21403
    • Wu WC, Fernandez-Seara M, Detre JA, Wehrli FW, Wang J,. A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling. Magn Reson Med 2007; 58: 1020-1027. (Pubitemid 350074370)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.5 , pp. 1020-1027
    • Wu, W.-C.1    Fernandez-Seara, M.2    Detre, J.A.3    Wehrli, F.W.4    Wang, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.