메뉴 건너뛰기




Volumn 22, Issue 1, 2005, Pages 119-124

Spatially-confined arterial spin-labeling with FAIR

Author keywords

ASL; FAIR; Large vessel signal; QUIPSS II; Spatially confined tagging

Indexed keywords

ADULT; ANGIOGRAPHY; ARTERY BLOOD FLOW; ARTICLE; BLOOD FLOW VELOCITY; CAPILLARY; CONTROLLED STUDY; HUMAN; PRIORITY JOURNAL; PULSE WAVE;

EID: 21244493234     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.20362     Document Type: Article
Times cited : (9)

References (24)
  • 1
  • 2
    • 0030723478 scopus 로고    scopus 로고
    • The efficiency of adiabatic inversion for perfusion imaging by barterial spin labeling
    • Maccotta L, Detre JA, Alsop DC. The efficiency of adiabatic inversion for perfusion imaging by barterial spin labeling. NMR Biomed 1997;10:216-221.
    • (1997) NMR Biomed , vol.10 , pp. 216-221
    • Maccotta, L.1    Detre, J.A.2    Alsop, D.C.3
  • 3
    • 0029952944 scopus 로고    scopus 로고
    • Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow
    • Alsop DC, Detre JA. Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow. J Cereb Blood Flow Metab 1996;16:1236-1249.
    • (1996) J Cereb Blood Flow Metab , vol.16 , pp. 1236-1249
    • Alsop, D.C.1    Detre, J.A.2
  • 4
    • 0031848388 scopus 로고    scopus 로고
    • A theoretical and experimental comparison of continuous and pulsed arterial spin labeling techniques for quantitative perfusion imaging
    • Wong EC, Buxton RB, Frank LR. A theoretical and experimental comparison of continuous and pulsed arterial spin labeling techniques for quantitative perfusion imaging. Magn Reson Med 1998; 40:348-355.
    • (1998) Magn Reson Med , vol.40 , pp. 348-355
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 5
    • 0029151256 scopus 로고
    • Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping
    • Kim SG. Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping. Magn Reson Med 1995;34:293-301.
    • (1995) Magn Reson Med , vol.34 , pp. 293-301
    • Kim, S.G.1
  • 6
    • 0031019253 scopus 로고    scopus 로고
    • Perfusion imaging by a flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional brain imaging
    • Kim SG, Tsekos NV. Perfusion imaging by a flow-sensitive alternating inversion recovery (FAIR) technique: application to functional brain imaging. Magn Reson Med 1997;37:425-435.
    • (1997) Magn Reson Med , vol.37 , pp. 425-435
    • Kim, S.G.1    Tsekos, N.V.2
  • 7
    • 0031956255 scopus 로고    scopus 로고
    • Multislice imaging of quantitative cerebral perfusion with pulsed arterial spin labeling
    • Yang Y, Frank JA, Hou L, et al. Multislice imaging of quantitative cerebral perfusion with pulsed arterial spin labeling. Magn Reson Med 1998;39:825-832.
    • (1998) Magn Reson Med , vol.39 , pp. 825-832
    • Yang, Y.1    Frank, J.A.2    Hou, L.3
  • 8
    • 0347634472 scopus 로고    scopus 로고
    • TurboFLASH FAIR imaging with optimized inversion and imaging profiles
    • Pell GS, Lewis DP, Ordidge RJ, et al. TurboFLASH FAIR imaging with optimized inversion and imaging profiles. Magn Reson Med 2004;51:46-54.
    • (2004) Magn Reson Med , vol.51 , pp. 46-54
    • Pell, G.S.1    Lewis, D.P.2    Ordidge, R.J.3
  • 9
    • 0032904710 scopus 로고    scopus 로고
    • Transfer insensitive labeling technique (TILT): Application to multislice functional perfusion imaging
    • Golay X, Stuber M, Pruessmann KP, et al. Transfer insensitive labeling technique (TILT): application to multislice functional perfusion imaging. J Magn Reson Imaging 1999;9:454-461.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 454-461
    • Golay, X.1    Stuber, M.2    Pruessmann, K.P.3
  • 10
    • 0033062040 scopus 로고    scopus 로고
    • MR perfusion imaging in human brain using the UNFAIR technique
    • Tanabe JL, Yongbi M, Branch CA, et al. MR perfusion imaging in human brain using the UNFAIR technique. J Magn Reson Imaging 1999;9:761-767.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 761-767
    • Tanabe, J.L.1    Yongbi, M.2    Branch, C.A.3
  • 11
    • 0037308616 scopus 로고    scopus 로고
    • Improved perfusion-weighted MRI by a novel double inversion with proximal labeling of both tagged and control acquisitions
    • Jahng GH, Zhu XP, Matson GB, et al. Improved perfusion-weighted MRI by a novel double inversion with proximal labeling of both tagged and control acquisitions. Magn Reson Med 2003;49:307-314.
    • (2003) Magn Reson Med , vol.49 , pp. 307-314
    • Jahng, G.H.1    Zhu, X.P.2    Matson, G.B.3
  • 12
    • 0028153930 scopus 로고
    • Signal targeting with alternating radio frequency
    • Edelman RR, Siewert B, Adamis M, et al. Signal targeting with alternating radio frequency. Magn Reson Med 1994;31:233-238.
    • (1994) Magn Reson Med , vol.31 , pp. 233-238
    • Edelman, R.R.1    Siewert, B.2    Adamis, M.3
  • 13
    • 0027936294 scopus 로고
    • Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency (STAR) sequences: Applications to MR angiography
    • Edelman RR, Siewert B, Darby DG, et al. Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency (STAR) sequences: applications to MR angiography. Radiology 1994;192:513-520.
    • (1994) Radiology , vol.192 , pp. 513-520
    • Edelman, R.R.1    Siewert, B.2    Darby, D.G.3
  • 14
    • 0035152994 scopus 로고    scopus 로고
    • RF excitation profiles with FAIR: Impact of truncation of the arterial input function on quantitative perfusion
    • Lipton ML, Branch CA, Hrabe J, et al. RF excitation profiles with FAIR: impact of truncation of the arterial input function on quantitative perfusion. J. Magn Reson Imaging 2001;13:207-214.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 207-214
    • Lipton, M.L.1    Branch, C.A.2    Hrabe, J.3
  • 15
    • 0032957305 scopus 로고    scopus 로고
    • Implementation of quantitative FAIR perfusion imaging with a short repetition time in time-course studies
    • Pell GS, Thomas DL, Lythgoe MF, et al. Implementation of quantitative FAIR perfusion imaging with a short repetition time in time-course studies. Magn Reson Med 1999;41:829-840.
    • (1999) Magn Reson Med , vol.41 , pp. 829-840
    • Pell, G.S.1    Thomas, D.L.2    Lythgoe, M.F.3
  • 16
    • 0033780827 scopus 로고    scopus 로고
    • Turbo ASL: Arterial spin labeling with higher SNR and temporal resolution
    • Wong EC, Luh W, Liu TT, Turbo ASL: arterial spin labeling with higher SNR and temporal resolution. Magn Reson Med 2000;44:511-515.
    • (2000) Magn Reson Med , vol.44 , pp. 511-515
    • Wong, E.C.1    Luh, W.2    Liu, T.T.3
  • 17
    • 0023678634 scopus 로고    scopus 로고
    • Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging
    • LeBihan D, Lallemand D, Aubin ML, et al. Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. Radiology 1998;168:497-505.
    • (1998) Radiology , vol.168 , pp. 497-505
    • Lebihan, D.1    Lallemand, D.2    Aubin, M.L.3
  • 18
    • 0141729439 scopus 로고    scopus 로고
    • Impact of large vessel signal on quantitative measures of cerebral oxygen extraction and blood volume under normo- And hypercapnic conditions using an asymmetric spin echo approach
    • An H, Lin W. Impact of large vessel signal on quantitative measures of cerebral oxygen extraction and blood volume under normo- and hypercapnic conditions using an asymmetric spin echo approach. Magn Reson Med 2003;50:708-716.
    • (2003) Magn Reson Med , vol.50 , pp. 708-716
    • An, H.1    Lin, W.2
  • 19
    • 0042839760 scopus 로고    scopus 로고
    • Arterial transit time imaging with flow encoding arterial spin tagging (FEAST)
    • Wang J, Alsop DC, Song HK, et al. Arterial transit time imaging with flow encoding arterial spin tagging (FEAST). Magn Reson Med 2003;50:599-607.
    • (2003) Magn Reson Med , vol.50 , pp. 599-607
    • Wang, J.1    Alsop, D.C.2    Song, H.K.3
  • 20
    • 0030725989 scopus 로고    scopus 로고
    • Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling
    • Wong EC, Buxton RB, Frank LR. Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling. NMR Biomed 1997;10:237-249.
    • (1997) NMR Biomed , vol.10 , pp. 237-249
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 21
    • 0031966050 scopus 로고    scopus 로고
    • Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
    • Wong EC, Buxton RB, Frank LR. Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II). Magn Reson Med 1998;39:702-708.
    • (1998) Magn Reson Med , vol.39 , pp. 702-708
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 22
    • 0031821720 scopus 로고    scopus 로고
    • A general kinetic model for quantitative perfusion imaging with arterial spin labeling
    • Buxton RB, Frank LR, Wong EC, et al. A general kinetic model for quantitative perfusion imaging with arterial spin labeling. Magn Reson Med 1998;40:383-396.
    • (1998) Magn Reson Med , vol.40 , pp. 383-396
    • Buxton, R.B.1    Frank, L.R.2    Wong, E.C.3
  • 23
    • 0033756491 scopus 로고    scopus 로고
    • Transit time, trailing time, and cerebral blood flow during brain activation: Measurement using multislice, pulsed spin-labeling perfusion imaging
    • Yang Y, Engelten W, Xu S, et al. Transit time, trailing time, and cerebral blood flow during brain activation: measurement using multislice, pulsed spin-labeling perfusion imaging. Magn Reson Med 2000;44:680-685.
    • (2000) Magn Reson Med , vol.44 , pp. 680-685
    • Yang, Y.1    Engelten, W.2    Xu, S.3
  • 24
    • 0032997648 scopus 로고    scopus 로고
    • 1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling
    • 1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling. Magn Reson Med 1999;41:1246-1254.
    • (1999) Magn Reson Med , vol.41 , pp. 1246-1254
    • Luh, W.1    Wong, E.C.2    Bandettini, P.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.