메뉴 건너뛰기




Volumn 56, Issue 10, 2011, Pages 2906-2913

Magnetic resonance enterography: Safe and effective imaging for stricturing Crohn's Disease

Author keywords

Crohn's disease; Ionizing radiation; Magnetic resonance enterography; Obstructive symptoms

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CLINICAL EFFECTIVENESS; CLINICAL FEATURE; CLINICAL PRACTICE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CROHN DISEASE; FEMALE; HUMAN; INFLAMMATION; INTESTINAL FIBROSIS; INTESTINE OBSTRUCTION; MAGNETIC RESONANCE ENTEROGRAPHY; MALE; MEDICAL DECISION MAKING; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RETROSPECTIVE STUDY; RISK ASSESSMENT; TERTIARY HEALTH CARE;

EID: 80054758771     PISSN: 01632116     EISSN: 15732568     Source Type: Journal    
DOI: 10.1007/s10620-011-1781-0     Document Type: Article
Times cited : (28)

References (24)
  • 2
    • 67449152457 scopus 로고    scopus 로고
    • Crohn's disease clinical issues and treatment: What the radiologist needs to know and what the gastroenterologist wants to know
    • 18493815 10.1007/s00261-008-9410-x
    • DH Bruining EV Loftus Jr 2009 Crohn's disease clinical issues and treatment: what the radiologist needs to know and what the gastroenterologist wants to know Abdom Imaging 34 297 302 18493815 10.1007/s00261-008-9410-x
    • (2009) Abdom Imaging , vol.34 , pp. 297-302
    • Bruining, D.H.1    Loftus Jr., E.V.2
  • 3
    • 0033964958 scopus 로고    scopus 로고
    • Crohn's disease evaluation: Comparison of contrast-enhanced MR imaging and single-phase helical CT scanning
    • DOI 10.1002/(SICI)1522-2586(200002)11:2<127::AID-JMRI8>3.0.CO;2-G
    • RN Low IR Francis D Politoske M Bennett 2000 Crohn's disease evaluation: comparison of contrast-enhanced MR imaging and single-phase helical CT scanning J Magn Reson Imaging 11 127 135 10713944 10.1002/(SICI)1522-2586(200002)11: 2<127::AID-JMRI8>3.0.CO;2-G 1:STN:280:DC%2BD3c7nvVarsQ%3D%3D (Pubitemid 30080965)
    • (2000) Journal of Magnetic Resonance Imaging , vol.11 , Issue.2 , pp. 127-135
    • Low, R.N.1    Francis, I.R.2    Politoske, D.3    Bennett, M.4
  • 4
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • DOI 10.1056/NEJMra072149
    • DJ Brenner EJ Hall 2007 Computed tomography-an increasing source of radiation exposure N Engl J Med 357 2277 2284 18046031 10.1056/NEJMra072149 1:CAS:528:DC%2BD2sXhsVSlurfF (Pubitemid 350190758)
    • (2007) New England Journal of Medicine , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 5
    • 69349096036 scopus 로고    scopus 로고
    • Exposure to low-dose ionizing radiation from medical imaging procedures
    • 19710483 10.1056/NEJMoa0901249 1:CAS:528:DC%2BD1MXhtVKhtL7M
    • R Fazel HM Krumholz Y Wang, et al. 2009 Exposure to low-dose ionizing radiation from medical imaging procedures N Engl J Med 361 849 857 19710483 10.1056/NEJMoa0901249 1:CAS:528:DC%2BD1MXhtVKhtL7M
    • (2009) N Engl J Med , vol.361 , pp. 849-857
    • Fazel, R.1    Krumholz, H.M.2    Wang, Y.3
  • 6
    • 33751578036 scopus 로고    scopus 로고
    • Internal fistulas in Crohn disease: Magnetic resonance enteroclysis
    • DOI 10.1007/s00261-005-0400-y
    • KA Herrmann HJ Michaely CJ Zech J Seiderer MF Reiser SO Schoenberg 2006 Internal fistulas in Crohn disease: magnetic resonance enteroclysis Abdom Imaging 31 675 687 16447079 10.1007/s00261-005-0400-y 1:STN:280: DC%2BD2s7ovVOntw%3D%3D (Pubitemid 46723629)
    • (2006) Abdominal Imaging , vol.31 , Issue.6 , pp. 675-687
    • Herrmann, K.A.1    Michaely, H.J.2    Zech, C.J.3    Seiderer, J.4    Reiser, M.F.5    Schoenberg, S.O.6
  • 8
    • 40049103469 scopus 로고    scopus 로고
    • Developing role of magnetic resonance imaging in Crohn's disease
    • DOI 10.1097/MOG.0b013e3282f49b14, PII 0000157420080300000007
    • MF Lin V Narra 2008 Developing role of magnetic resonance imaging in Crohn's disease Curr Opin Gastroenterol 24 135 140 18301262 10.1097/MOG. 0b013e3282f49b14 (Pubitemid 351322778)
    • (2008) Current Opinion in Gastroenterology , vol.24 , Issue.2 , pp. 135-140
    • Lin, M.F.1    Narra, V.2
  • 9
    • 77952360727 scopus 로고    scopus 로고
    • Role of magnetic resonance enterography in the management of Crohn disease
    • 20479346 10.1001/archsurg.2010.68
    • E Messaris N Chandolias D Grand V Pricolo 2010 Role of magnetic resonance enterography in the management of Crohn disease Arch Surg 145 471 475 20479346 10.1001/archsurg.2010.68
    • (2010) Arch Surg , vol.145 , pp. 471-475
    • Messaris, E.1    Chandolias, N.2    Grand, D.3    Pricolo, V.4
  • 10
    • 60949090275 scopus 로고    scopus 로고
    • Role of MRI in Crohn's disease
    • 19264177 10.1016/j.crad.2008.08.006 1:STN:280:DC%2BD1M7ovV2jsQ%3D%3D
    • R Sinha P Murphy P Hawker S Sanders A Rajesh R Verma 2009 Role of MRI in Crohn's disease Clin Radiol 64 341 352 19264177 10.1016/j.crad.2008.08.006 1:STN:280:DC%2BD1M7ovV2jsQ%3D%3D
    • (2009) Clin Radiol , vol.64 , pp. 341-352
    • Sinha, R.1    Murphy, P.2    Hawker, P.3    Sanders, S.4    Rajesh, A.5    Verma, R.6
  • 11
    • 49349095292 scopus 로고    scopus 로고
    • Diagnostic ionizing radiation exposure in a population-based cohort of patients with inflammatory bowel disease
    • 18564113 10.1111/j.1572-0241.2008.01920.x
    • JM Peloquin DS Pardi WJ Sandborn, et al. 2008 Diagnostic ionizing radiation exposure in a population-based cohort of patients with inflammatory bowel disease Am J Gastroenterol 103 2015 2022 18564113 10.1111/j.1572-0241. 2008.01920.x
    • (2008) Am J Gastroenterol , vol.103 , pp. 2015-2022
    • Peloquin, J.M.1    Pardi, D.S.2    Sandborn, W.J.3
  • 12
    • 62849102579 scopus 로고    scopus 로고
    • Ct enterography: Principles, technique and utility in Crohn's disease
    • 19118968 10.1016/j.ejrad.2008.11.014
    • JE Huprich JG Fletcher 2009 Ct enterography: principles, technique and utility in Crohn's disease Eur J Radiol 69 393 397 19118968 10.1016/j.ejrad. 2008.11.014
    • (2009) Eur J Radiol , vol.69 , pp. 393-397
    • Huprich, J.E.1    Fletcher, J.G.2
  • 14
    • 80054718054 scopus 로고    scopus 로고
    • Benefit of computed tomography enterography in Crohn's disease: Effects on patient management and physician level of confidence
    • (Epub ahead of print). doi: 10.1002/ibd.21683
    • Bruining DH, Siddiki HA, Fletcher JG, et al. Benefit of computed tomography enterography in Crohn's disease: effects on patient management and physician level of confidence. Inflamm Bowel Dis. (Epub ahead of print). doi: 10.1002/ibd.21683
    • Inflamm Bowel Dis
    • Bruining, D.H.1    Siddiki, H.A.2    Fletcher, J.G.3
  • 15
    • 73149110471 scopus 로고    scopus 로고
    • Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer
    • 20008690 10.1001/archinternmed.2009.427
    • R Smith-Bindman J Lipson R Marcus, et al. 2009 Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer Arch Intern Med 169 2078 2086 20008690 10.1001/archinternmed.2009.427
    • (2009) Arch Intern Med , vol.169 , pp. 2078-2086
    • Smith-Bindman, R.1    Lipson, J.2    Marcus, R.3
  • 16
    • 0034200215 scopus 로고    scopus 로고
    • Imaging recommendations for patients with newly suspected Crohn's disease, and in patients with known Crohn's disease and acute exacerbation or suspected complications. American College of Radiology. ACR appropriateness criteria
    • 11037424
    • R Kidd DG Mezwa PW Ralls, et al. 2000 Imaging recommendations for patients with newly suspected Crohn's disease, and in patients with known Crohn's disease and acute exacerbation or suspected complications. American College of Radiology. ACR appropriateness criteria Radiology 215 181 192 11037424
    • (2000) Radiology , vol.215 , pp. 181-192
    • Kidd, R.1    Mezwa, D.G.2    Ralls, P.W.3
  • 17
    • 54349083883 scopus 로고    scopus 로고
    • Crohn's disease: Factors associated with exposure to high levels of diagnostic radiation
    • 18443021 10.1136/gut.2008.151415 1:STN:280:DC%2BD1cnnsFOmuw%3D%3D
    • AN Desmond K O'Regan C Curran, et al. 2008 Crohn's disease: factors associated with exposure to high levels of diagnostic radiation Gut 57 1524 1529 18443021 10.1136/gut.2008.151415 1:STN:280:DC%2BD1cnnsFOmuw%3D%3D
    • (2008) Gut , vol.57 , pp. 1524-1529
    • Desmond, A.N.1    O'Regan, K.2    Curran, C.3
  • 19
    • 77954230504 scopus 로고    scopus 로고
    • Is computed tomography safe?
    • 20573919 10.1056/NEJMp1002530 1:CAS:528:DC%2BC3cXpslyjsbg%3D
    • R Smith-Bindman 2010 Is computed tomography safe? N Engl J Med 363 1 4 20573919 10.1056/NEJMp1002530 1:CAS:528:DC%2BC3cXpslyjsbg%3D
    • (2010) N Engl J Med , vol.363 , pp. 1-4
    • Smith-Bindman, R.1
  • 20
    • 77957861471 scopus 로고    scopus 로고
    • MR enterography with polyethylene glycol as oral contrast medium in the follow-up of patients with Crohn disease: Comparison with CT enterography
    • 19582502 10.1007/s00261-009-9557-0
    • D Ippolito F Invernizzi S Galimberti MR Panelli S Sironi 2010 MR enterography with polyethylene glycol as oral contrast medium in the follow-up of patients with Crohn disease: comparison with CT enterography Abdom Imaging 35 563 570 19582502 10.1007/s00261-009-9557-0
    • (2010) Abdom Imaging , vol.35 , pp. 563-570
    • Ippolito, D.1    Invernizzi, F.2    Galimberti, S.3    Panelli, M.R.4    Sironi, S.5
  • 21
    • 67049160346 scopus 로고    scopus 로고
    • Crohn disease of the small bowel: Comparison of CT enterography, MR enterography, and small-bowel follow-through as diagnostic techniques
    • 19276325 10.1148/radiol.2513081184
    • SS Lee AY Kim SK Yang, et al. 2009 Crohn disease of the small bowel: comparison of CT enterography, MR enterography, and small-bowel follow-through as diagnostic techniques Radiology 251 751 761 19276325 10.1148/radiol. 2513081184
    • (2009) Radiology , vol.251 , pp. 751-761
    • Lee, S.S.1    Kim, A.Y.2    Yang, S.K.3
  • 22
    • 67650294062 scopus 로고    scopus 로고
    • Prospective comparison of state-of-the-art MR enterography and CT enterography in small-bowel Crohn's disease
    • 10.2214/AJR.08.2027
    • HA Siddiki JL Fidler JG Fletcher, et al. 2009 Prospective comparison of state-of-the-art MR enterography and CT enterography in small-bowel Crohn's disease Am J Roentgenol 193 113 121 10.2214/AJR.08.2027
    • (2009) Am J Roentgenol , vol.193 , pp. 113-121
    • Siddiki, H.A.1    Fidler, J.L.2    Fletcher, J.G.3
  • 23
    • 67650248682 scopus 로고    scopus 로고
    • Magnetic resonance for assessment of disease activity and severity in ileocolonic Crohn's disease
    • 19136510 10.1136/gut.2008.167957 1:STN:280:DC%2BD1Mvns1KmsA%3D%3D
    • J Rimola S Rodriguez O Garcia-Bosch, et al. 2009 Magnetic resonance for assessment of disease activity and severity in ileocolonic Crohn's disease Gut 58 1113 1120 19136510 10.1136/gut.2008.167957 1:STN:280:DC%2BD1Mvns1KmsA%3D%3D
    • (2009) Gut , vol.58 , pp. 1113-1120
    • Rimola, J.1    Rodriguez, S.2    Garcia-Bosch, O.3
  • 24
    • 73949130763 scopus 로고    scopus 로고
    • Assessment of appropriateness of indications for CT enterography in younger patients
    • 19637359
    • LS Guimaraes JL Fidler JG Fletcher, et al. 2010 Assessment of appropriateness of indications for CT enterography in younger patients Inflamm Bowel Dis 16 226 232 19637359
    • (2010) Inflamm Bowel Dis , vol.16 , pp. 226-232
    • Guimaraes, L.S.1    Fidler, J.L.2    Fletcher, J.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.