메뉴 건너뛰기




Volumn 34, Issue 10, 2011, Pages 1209-1216

Percutaneous lead and system extraction in patients with cardiac resynchronization therapy (CRT) devices and coronary sinus leads

Author keywords

CRT; defibrillation ICD; lead extraction; pacing

Indexed keywords

ADULT; AGED; ARTICLE; CARDIAC RESYNCHRONIZATION THERAPY; COHORT ANALYSIS; COMORBIDITY; CORONARY SINUS; EXTRACTION; FEMALE; HEART LEFT VENTRICLE EJECTION FRACTION; HUMAN; IMPLANTATION; LASER; MAJOR CLINICAL STUDY; MALE; PERCUTANEOUS LEAD AND SYSTEM EXTRACTION; TRACTION THERAPY; TREATMENT DURATION;

EID: 80054754256     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2011.03149.x     Document Type: Article
Times cited : (30)

References (17)
  • 1
    • 60649088431 scopus 로고    scopus 로고
    • Effects of cardiac resynchronization therapy on long-term quality of life: An analysis from the cardiac resynchronisation-heart failure (care-hf) study
    • Cleland JG, Calvert MJ, Verboven Y, Freemantle N,. Effects of cardiac resynchronization therapy on long-term quality of life: An analysis from the cardiac resynchronisation-heart failure (care-hf) study. Am Heart J 2009; 157: 457-466.
    • (2009) Am Heart J , vol.157 , pp. 457-466
    • Cleland, J.G.1    Calvert, M.J.2    Verboven, Y.3    Freemantle, N.4
  • 2
    • 59449106464 scopus 로고    scopus 로고
    • Extraction of chronic pacemaker and defibrillator leads from the coronary sinus: Laser infrequently used but required
    • Hamid S, Arujuna A, Khan S, Ladwiniec A, McPhail M, Bostock J, Mobb M, et al,. Extraction of chronic pacemaker and defibrillator leads from the coronary sinus: Laser infrequently used but required. Europace 2009; 11: 213-215.
    • (2009) Europace , vol.11 , pp. 213-215
    • Hamid, S.1    Arujuna, A.2    Khan, S.3    Ladwiniec, A.4    McPhail, M.5    Bostock, J.6    Mobb, M.7
  • 4
    • 12844255864 scopus 로고    scopus 로고
    • Coronary sinus lead extraction in the era of cardiac resynchronization therapy: Single center experience
    • DOI 10.1111/j.1540-8159.2005.09353.x
    • Kasravi B, Tobias S, Barnes MJ, Messenger JC,. Coronary sinus lead extraction in the era of cardiac resynchronization therapy: Single-center experience. Pacing Clin Electrophysiol 2005; 28: 51-53. (Pubitemid 40171145)
    • (2005) PACE - Pacing and Clinical Electrophysiology , vol.28 , Issue.1 , pp. 51-53
    • Kasravi, B.1    Tobias, S.2    Barnes, M.J.3    Messenger, J.C.4
  • 8
    • 0033133418 scopus 로고    scopus 로고
    • Pacemaker lead extraction with the laser sheath: Results of the pacing lead extraction with the excimer sheath (plexes) trial
    • Wilkoff BL, Byrd CL, Love CJ, Hayes DL, Sellers TD, Schaerf R, Parsonnet V, et al,. Pacemaker lead extraction with the laser sheath: Results of the pacing lead extraction with the excimer sheath (plexes) trial. J Am Coll Cardiol 1999; 33: 1671-1676.
    • (1999) J Am Coll Cardiol , vol.33 , pp. 1671-1676
    • Wilkoff, B.L.1    Byrd, C.L.2    Love, C.J.3    Hayes, D.L.4    Sellers, T.D.5    Schaerf, R.6    Parsonnet, V.7
  • 9
    • 71049192265 scopus 로고    scopus 로고
    • Single-operator experience with a mechanical approach for removal of pacing and implantable defibrillator leads
    • Calvagna GM, Evola R, Scardace G, Valsecchi S,. Single-operator experience with a mechanical approach for removal of pacing and implantable defibrillator leads. Europace 2009; 11: 1505-1509.
    • (2009) Europace , vol.11 , pp. 1505-1509
    • Calvagna, G.M.1    Evola, R.2    Scardace, G.3    Valsecchi, S.4
  • 11
    • 67549100824 scopus 로고    scopus 로고
    • Transvenous lead extraction: Heart rhythm society expert consensus on facilities, training, indications, and patient management: This document was endorsed by the American Heart Association (AHA)
    • Wilkoff BL, Love CJ, Byrd CL, Bongiorni MG, Carrillo RG, Crossley GH, 3rd, Epstein LM, et al,. Transvenous lead extraction: Heart rhythm society expert consensus on facilities, training, indications, and patient management: This document was endorsed by the American Heart Association (AHA). Heart Rhythm 2009; 6: 1085-1104.
    • Heart Rhythm 2009 , vol.6 , pp. 1085-1104
    • Wilkoff, B.L.1    Love, C.J.2    Byrd, C.L.3    Bongiorni, M.G.4    Carrillo, R.G.5    Crossley III, G.H.6    Epstein, L.M.7
  • 12
    • 34548147470 scopus 로고    scopus 로고
    • Cardiac resynchronisation therapy for the treatment of heart failure: NICE technology appraisal guidance
    • DOI 10.1136/hrt.2007.127563
    • Barnett D, Phillips S, Longson C,. Cardiac resynchronisation therapy for the treatment of heart failure: Nice technology appraisal guidance. Heart 2007; 93: 1134-1135. (Pubitemid 47310998)
    • (2007) Heart , vol.93 , Issue.9 , pp. 1134-1135
    • Barnett, D.1    Phillips, S.2    Longson, C.3
  • 13
    • 57349111725 scopus 로고    scopus 로고
    • Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: High success rate and safety in more than 2000 leads
    • Bongiorni MG, Soldati E, Zucchelli G, Di Cori A, Segreti L, De Lucia R, Solarino G, et al,. Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: High success rate and safety in more than 2000 leads. Eur Heart J 2008; 29: 2886-2893.
    • (2008) Eur Heart J , vol.29 , pp. 2886-2893
    • Bongiorni, M.G.1    Soldati, E.2    Zucchelli, G.3    Di Cori, A.4    Segreti, L.5    De Lucia, R.6    Solarino, G.7
  • 14
    • 66749148454 scopus 로고    scopus 로고
    • A single-centre experience of over one thousand lead extractions
    • Kennergren C, Bjurman C, Wiklund R, Gabel J,. A single-centre experience of over one thousand lead extractions. Europace 2009; 11: 612-617.
    • (2009) Europace , vol.11 , pp. 612-617
    • Kennergren, C.1    Bjurman, C.2    Wiklund, R.3    Gabel, J.4
  • 16
    • 84860388803 scopus 로고    scopus 로고
    • A modified transvenous single mechanical dilatation technique to remove a chronically implanted active-fixation coronary sinus pacing lead
    • Bongiorni MG, A DIC, Zucchelli G, Segreti L, R DEL, Paperini L, Soldati E,. A modified transvenous single mechanical dilatation technique to remove a chronically implanted active-fixation coronary sinus pacing lead. Pacing Clin Electrophysiol 2011; 34: e66-e69.
    • (2011) Pacing Clin Electrophysiol , vol.34
    • Bongiorni, M.G.1    C, A.D.I.2    Zucchelli, G.3    Segreti, L.4    L, R.D.E.5    Paperini, L.6    Soldati, E.7
  • 17
    • 80054743562 scopus 로고    scopus 로고
    • Fibrotic tissue growth into the extendable lobes of an active fixation coronary sinus lead can complicate extraction
    • Baranowski B, Yerkey M, Dresing T, Wilkoff BL,. Fibrotic tissue growth into the extendable lobes of an active fixation coronary sinus lead can complicate extraction. Pacing Clin Electrophysiol 2010.
    • (2010) Pacing Clin Electrophysiol
    • Baranowski, B.1    Yerkey, M.2    Dresing, T.3    Wilkoff, B.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.