-
1
-
-
0036654483
-
The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients
-
J.S. Feine, G.E. Carlsson, M.A. Awad, A. Chehade, W.J. Duncan, and S. Gizani The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients Gerodontology 19 2002 3 4
-
(2002)
Gerodontology
, vol.19
, pp. 3-4
-
-
Feine, J.S.1
Carlsson, G.E.2
Awad, M.A.3
Chehade, A.4
Duncan, W.J.5
Gizani, S.6
-
2
-
-
67650488954
-
A qualitative study on patient perspectives of how conventional and implant-supported dentures affect eating
-
R. Hyland, J. Ellis, M. Thomason, A. El-Feky, and P. Moynihan A qualitative study on patient perspectives of how conventional and implant-supported dentures affect eating Journal of Dentistry 37 2009 718 723
-
(2009)
Journal of Dentistry
, vol.37
, pp. 718-723
-
-
Hyland, R.1
Ellis, J.2
Thomason, M.3
El-Feky, A.4
Moynihan, P.5
-
4
-
-
59049102263
-
Massive sublingual haematoma following osseo-integrated implant placement in the anterior mandible
-
N. Pigadas, P. Simoes, and J.R. Tuffin Massive sublingual haematoma following osseo-integrated implant placement in the anterior mandible British Dental Journal 206 2009 67 68
-
(2009)
British Dental Journal
, vol.206
, pp. 67-68
-
-
Pigadas, N.1
Simoes, P.2
Tuffin, J.R.3
-
5
-
-
3042517245
-
Hemorrhaging associated with endosseous implant placement in the anterior mandible: A review of the literature
-
C.D. Kalpidis, and R.M. Setayesh Hemorrhaging associated with endosseous implant placement in the anterior mandible: a review of the literature Journal of Periodontology 75 2004 631 645 (Pubitemid 38811852)
-
(2004)
Journal of Periodontology
, vol.75
, Issue.5
, pp. 631-645
-
-
Kalpidis, C.D.R.1
Setayesh, R.M.2
-
6
-
-
77953707372
-
The role of primary stability for successful immediate loading of dental implants. A literature review
-
F. Javed, and G.E. Romanos The role of primary stability for successful immediate loading of dental implants. A literature review Journal of Dentistry 38 2010 612 620
-
(2010)
Journal of Dentistry
, vol.38
, pp. 612-620
-
-
Javed, F.1
Romanos, G.E.2
-
7
-
-
33645459460
-
-
Fgdp(uk) 2nd edn. Faculty of General Dental Practitioners (UK) Royal College of Surgeons of England
-
FGDP(UK) Selection criteria in dental radiography 2nd edn. 2004 Faculty of General Dental Practitioners (UK) Royal College of Surgeons of England
-
(2004)
Selection Criteria in Dental Radiography
-
-
-
9
-
-
18544400674
-
E.A.O. guidelines for the use of diagnostic imaging in implant dentistry: A consensus workshop organized by the European Association for Osseointegration in Trinity College Dublin
-
DOI 10.1034/j.1600-0501.2002.130518.x
-
D. Harris, D. Buser, K. Dula, K. Grondahl, D. Harris, and R. Jacobs E.A.O. guidelines for the use of diagnostic imaging in implant dentistry. A consensus workshop organized by the European Association for Osseointegration in Trinity College Dublin Clinical Oral Implants Research 13 2002 566 570 (Pubitemid 41713085)
-
(2002)
Clinical Oral Implants Research
, vol.13
, Issue.5
, pp. 566-570
-
-
Harris, D.1
Buser, D.2
Dula, K.3
Grondahl, K.4
Jacobs, R.5
Lekholm, U.6
Nakielny, R.7
Van Steenberghe, D.8
Van Der Stelt, P.9
-
10
-
-
0034183344
-
Selection criteria for dental implant site imaging: A position paper of the American Academy of Oral and Maxillofacial radiology
-
D.A. Tyndall, and S.L. Brooks Selection criteria for dental implant site imaging: a position paper of the American Academy of Oral and Maxillofacial radiology Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontics 89 2000 630 637
-
(2000)
Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontics
, vol.89
, pp. 630-637
-
-
Tyndall, D.A.1
Brooks, S.L.2
-
11
-
-
65349143077
-
A transymphyseal X-ray projection to assess the anterior edentulous mandible prior to implant placement
-
A.M. Shelley, and K. Horner A transymphyseal X-ray projection to assess the anterior edentulous mandible prior to implant placement Dental Update 35 2008 689 694
-
(2008)
Dental Update
, vol.35
, pp. 689-694
-
-
Shelley, A.M.1
Horner, K.2
-
13
-
-
0023049334
-
Statistics in medicine: Confidence intervals rather than P values: Estimation rather than hypothesis testing
-
M.J. Gardner, and D.G. Altman Confidence intervals rather than P values: estimation rather than hypothesis testing British Medical Journal (Clinical Research Edition) 292 1986 746 750 (Pubitemid 16167414)
-
(1986)
British Medical Journal
, vol.292
, Issue.6522
, pp. 746-750
-
-
Gardner, M.J.1
Altman, D.G.2
-
14
-
-
84973587732
-
A coefficient of agreement for nominal scales
-
J. Cohen A coefficient of agreement for nominal scales Educational Psychological Measurement 20 1960 37 46
-
(1960)
Educational Psychological Measurement
, vol.20
, pp. 37-46
-
-
Cohen, J.1
-
15
-
-
0017360990
-
The measurement of observer agreement for categorical data
-
J.R. Landis, and G.G. Koch The measurement of observer agreement for categorical data Biometrics 33 1977 159 174 (Pubitemid 8054849)
-
(1977)
Biometrics
, vol.33
, Issue.1
, pp. 159-174
-
-
Landis, J.R.1
Koch, G.G.2
-
16
-
-
0029906864
-
Evaluating quality-of-life and health status instruments: Development of scientific review criteria
-
K.N. Lohr, N.K. Aaronson, J. Alonso, M.A. Burnam, D.L. Patrick, and E.B. Perrin Evaluating quality-of-life and health status instruments: development of scientific review criteria Clinical Therapeutics 18 1996 979 992
-
(1996)
Clinical Therapeutics
, vol.18
, pp. 979-992
-
-
Lohr, K.N.1
Aaronson, N.K.2
Alonso, J.3
Burnam, M.A.4
Patrick, D.L.5
Perrin, E.B.6
-
17
-
-
0034156669
-
Subjective image quality of solid-state and photostimulable phosphor systems for digital intra-oral radiography
-
E. Borg, A. Attaelmanan, and H.G. Grondahl Subjective image quality of solid-state and photostimulable phosphor systems for digital intra-oral radiography Dentomaxillofacial Radiology 29 2000 70 75
-
(2000)
Dentomaxillofacial Radiology
, vol.29
, pp. 70-75
-
-
Borg, E.1
Attaelmanan, A.2
Grondahl, H.G.3
-
18
-
-
0030075853
-
Endodontic measurements in digital radiographs acquired by a photostimulable, storage phosphor system
-
E. Borg, and H.G. Grondahl Endodontic measurements in digital radiographs acquired by a photostimulable, storage phosphor system Endodontics & Dental Traumatology 12 1996 20 24 (Pubitemid 126797132)
-
(1996)
Endodontics and Dental Traumatology
, vol.12
, Issue.1
, pp. 20-24
-
-
Borg, E.1
Grondahl, H.-G.2
-
19
-
-
48449091436
-
Measurement accuracy and perceived quality of imaging systems for the evaluation of periodontal structures
-
B.G. Baksi Measurement accuracy and perceived quality of imaging systems for the evaluation of periodontal structures Odontology 96 2008 55 60
-
(2008)
Odontology
, vol.96
, pp. 55-60
-
-
Baksi, B.G.1
-
20
-
-
0030112207
-
On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems
-
E. Borg, and H.G. Grondahl On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems Dentomaxillofacial Radiology 25 1996 82 88
-
(1996)
Dentomaxillofacial Radiology
, vol.25
, pp. 82-88
-
-
Borg, E.1
Grondahl, H.G.2
-
21
-
-
77955850723
-
A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT). Part I. on subjective image quality
-
X. Liang, R. Jacobs, B. Hassan, L. Li, R. Pauwels, and L. Corpas A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT). Part I. On subjective image quality European Journal of Radiology 75 2010 265 269
-
(2010)
European Journal of Radiology
, vol.75
, pp. 265-269
-
-
Liang, X.1
Jacobs, R.2
Hassan, B.3
Li, L.4
Pauwels, R.5
Corpas, L.6
-
22
-
-
58249105408
-
Influence of voxel size in the diagnostic ability of cone beam tomography to evaluate simulated external root resorption
-
G.S. Liedke, H.E. da Silveira, H.L. da Silveira, V. Dutra, and J.A. de Figueiredo Influence of voxel size in the diagnostic ability of cone beam tomography to evaluate simulated external root resorption Journal of Endodontics 35 2009 233 235
-
(2009)
Journal of Endodontics
, vol.35
, pp. 233-235
-
-
Liedke, G.S.1
Da Silveira, H.E.2
Da Silveira, H.L.3
Dutra, V.4
De Figueiredo, J.A.5
-
23
-
-
14044258579
-
Effect of number of projections on image quality of local CT
-
DOI 10.1259/dmfr/23496562
-
A.N. van Daatselaar, P.F. van der Stelt, and J. Weenen Effect of number of projections on image quality of local CT Dentomaxillofacial Radiology 33 2004 361 369 (Pubitemid 40278843)
-
(2004)
Dentomaxillofacial Radiology
, vol.33
, Issue.6
, pp. 361-369
-
-
Van Daatselaar, A.N.1
Van Der Stelt, P.F.2
Weenen, J.3
-
24
-
-
84857800878
-
-
internet]. Manchester: The University of Manchester; 2009. Available from
-
The Sedentexct Project [internet]. Manchester: The University of Manchester; 2009. Available from: www.sedentexct.eu.
-
The Sedentexct Project
-
-
-
25
-
-
52749087498
-
Patient risk related to common dental radiographic examinations: The impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculation
-
J.B. Ludlow, L.E. Davies-Ludlow, and S.C. White Patient risk related to common dental radiographic examinations: the impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculation Journal of the American Dental Association 139 2008 1237 1243
-
(2008)
Journal of the American Dental Association
, vol.139
, pp. 1237-1243
-
-
Ludlow, J.B.1
Davies-Ludlow, L.E.2
White, S.C.3
|