메뉴 건너뛰기




Volumn 100, Issue 3, 2011, Pages 429-435

Experimental small field 6 MV output ratio analysis for various diode detector and accelerator combinations

Author keywords

Diode detector; Dosimetry; Small field

Indexed keywords

ARTICLE; DIODE; ELECTROMAGNETIC FIELD; LINEAR ACCELERATOR; PRIORITY JOURNAL; RADIATION DETECTION; RADIATION DOSE; RADIATION MEASUREMENT; STEREOTACTIC PROCEDURE;

EID: 80054067428     PISSN: 01678140     EISSN: 18790887     Source Type: Journal    
DOI: 10.1016/j.radonc.2011.09.002     Document Type: Article
Times cited : (51)

References (26)
  • 2
    • 37549052531 scopus 로고    scopus 로고
    • Small fields: Nonequilibrium radiation dosimetry
    • I.J. Das, G.X. Ding, and A. Ahnesjo Small fields: nonequilibrium radiation dosimetry Med Phys 35 2008 206 215
    • (2008) Med Phys , vol.35 , pp. 206-215
    • Das, I.J.1    Ding, G.X.2    Ahnesjo, A.3
  • 3
    • 0037339773 scopus 로고    scopus 로고
    • The volume effect of detectors in the dosimetry of small fields used in IMRT
    • DOI 10.1118/1.1544678
    • W.U. Laud, and T. Wong The volume effect of detectors in the dosimetry of small fields used in IMRT Med Phys 30 2003 341 347 (Pubitemid 36337100)
    • (2003) Medical Physics , vol.30 , Issue.3 , pp. 341-347
    • Lauba, W.U.1    Wong, T.2
  • 4
    • 0038497899 scopus 로고    scopus 로고
    • An investigation of the photon energy dependence of the EPR alanine dosimetry system
    • DOI 10.1088/0031-9155/48/12/306, PII S0031915503574929
    • E.S. Bergstrand, K.R. Shortt, C.H. Ross, and E.O. Hole An investigation of the photon energy dependence of the EPR alanine dosimetry system Phys Med Biol 48 2003 1753 1771 (Pubitemid 36805848)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.12 , pp. 1753-1771
    • Bergstrand, E.S.1    Shortt, K.R.2    Ross, C.K.3    Hole, E.O.4
  • 5
    • 10644227698 scopus 로고    scopus 로고
    • K-band EPR dosimetry: Small-field beam profile determination with miniature alanine dosimeter
    • DOI 10.1016/j.apradiso.2004.08.036, PII S0969804304004713
    • F. Chen, C.F. Graeff, and O. Baffa K-band EPR dosimetry: small-field beam profile determination with miniature alanine dosimeter Appl Radiat Isot 62 2005 267 271 (Pubitemid 39655667)
    • (2005) Applied Radiation and Isotopes , vol.62 , Issue.SPEC. ISS. , pp. 267-271
    • Chen, F.1    Graeff, C.F.O.2    Baffa, O.3
  • 6
    • 0026804696 scopus 로고
    • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations
    • A.S. Beddar, T.R. Mackie, and F.H. Attix Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations Phys Med Biol 37 1992 1883 1900
    • (1992) Phys Med Biol , vol.37 , pp. 1883-1900
    • Beddar, A.S.1    MacKie, T.R.2    Attix, F.H.3
  • 7
    • 45749136904 scopus 로고    scopus 로고
    • Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide
    • DOI 10.1088/0031-9155/53/11/021, PII S0031915508750449
    • J. Lambert, Y. Yin, and D.R. McKenzie Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide Phys Med Biol 53 2008 3071 3080 (Pubitemid 351868624)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.11 , pp. 3071-3080
    • Lambert, J.1    Yin, Y.2    McKenzie, D.R.3    Law, S.4    Suchowerska, N.5
  • 8
    • 77957705127 scopus 로고    scopus 로고
    • Measuring output ratios of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors
    • D.M. Klein, R.C. Tailor, and L. Archambault Measuring output ratios of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors Med Phys 37 2010 5541 5549
    • (2010) Med Phys , vol.37 , pp. 5541-5549
    • Klein, D.M.1    Tailor, R.C.2    Archambault, L.3
  • 9
    • 79952137211 scopus 로고    scopus 로고
    • Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations
    • L.L.W. Wang, and S. Beddar Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations Med Phys 38 2011 1596 1599
    • (2011) Med Phys , vol.38 , pp. 1596-1599
    • Wang, L.L.W.1    Beddar, S.2
  • 10
    • 36349023169 scopus 로고    scopus 로고
    • Head scatter factors for small MV photon fields. Part II: The effects of source size and detector
    • DOI 10.1016/j.radonc.2007.09.006, PII S0167814007004616
    • C. McKerracher, and D.I. Thwaites Head scatter ratios for small MV photon fields. Part II: The effects of source size and detector Radiother Oncol 85 2007 286 291 (Pubitemid 350161011)
    • (2007) Radiotherapy and Oncology , vol.85 , Issue.2 , pp. 286-291
    • McKerracher, C.1    Thwaites, D.I.2
  • 11
    • 34447336432 scopus 로고    scopus 로고
    • Measurement of output factors for small photon beams
    • DOI 10.1118/1.2734383
    • O.A. Sauer, and J. Wilbert Measurement of output ratios for small photon fields Med Phys 34 2007 1983 1988 (Pubitemid 47055733)
    • (2007) Medical Physics , vol.34 , Issue.6 , pp. 1983-1988
    • Sauer, O.A.1    Wilbert, J.2
  • 12
    • 36348947412 scopus 로고    scopus 로고
    • Head scatter factors for small MV photon fields. Part I: A comparison of phantom types and methodologies
    • DOI 10.1016/j.radonc.2007.09.005, PII S0167814007004604
    • C. McKerracher, and D.I. Thwaites Head scatter ratios for small MV photon fields. Part I: A comparison of phantom types and methodologies Radiother Oncol 85 2007 277 285 (Pubitemid 350161010)
    • (2007) Radiotherapy and Oncology , vol.85 , Issue.2 , pp. 277-285
    • McKerracher, C.1    Thwaites, D.I.2
  • 13
    • 38949117985 scopus 로고    scopus 로고
    • Phantom scatter factors for small MV photon fields
    • DOI 10.1016/j.radonc.2007.10.040, PII S0167814007005506
    • C. McKerracher, and D.I. Thwaites Phantom scatter ratios for small MV photon fields Radiother Oncol 86 2008 272 275 (Pubitemid 351215202)
    • (2008) Radiotherapy and Oncology , vol.86 , Issue.2 , pp. 272-275
    • McKerracher, C.1    Thwaites, D.I.2
  • 14
    • 3142711454 scopus 로고    scopus 로고
    • A new approach in dose measurement and error analysis for narrow photon beams (beamlets) shaped by different multileaf collimators using a small detector
    • DOI 10.1118/1.1760191
    • S. Li, A. Rashid, S. He, and D. Djajaputra A new approach in dose measurement and error analysis for narrow photon beams (beamlets) shaped by different multileaf collimators using a small detector Med Phys 31 2004 2020 2032 (Pubitemid 38924822)
    • (2004) Medical Physics , vol.31 , Issue.7 , pp. 2020-2032
    • Li, S.1    Rashid, A.2    He, S.3    Djajaputra, D.4
  • 15
    • 33645009141 scopus 로고    scopus 로고
    • Dosimetric characteristics of a new unshielded silicon diode and its application in clinical photon and electron beams
    • I. Griessbach, M. Lapp, G. Gademann, and D. Harder Dosimetric characteristics of a new unshielded silicon diode and its application in clinical photon and electron beams Med Phys 32 2005 3750 3754
    • (2005) Med Phys , vol.32 , pp. 3750-3754
    • Griessbach, I.1    Lapp, M.2    Gademann, G.3    Harder, D.4
  • 16
    • 33746211628 scopus 로고    scopus 로고
    • Notes on the construction of solid-state detectors
    • DOI 10.1016/j.radonc.2006.05.008, PII S0167814006002052
    • C. McKerracher, and D.I. Thwaites Notes on the construction of solid-state detectors Radiother Oncol 79 2006 348 351 (Pubitemid 44093763)
    • (2006) Radiotherapy and Oncology , vol.79 , Issue.3 , pp. 348-351
    • McKerracher, C.1    Thwaites, D.I.2
  • 19
    • 0037701288 scopus 로고    scopus 로고
    • Focal spot motion of linear accelerators and its effect on portal image analysis
    • DOI 10.1118/1.1576229
    • J.J. Sonke, B. Brand, and M. van Herk Focal spot motion of linear accelerators and its effect on portal image analysis Med Phys 30 2003 1067 1075 (Pubitemid 36735972)
    • (2003) Medical Physics , vol.30 , Issue.6 , pp. 1067-1075
    • Sonke, J.-J.1    Brand, B.2    Van Herk, M.3
  • 20
    • 52949151876 scopus 로고    scopus 로고
    • Using a Monte Carlo model to predict dosimetric properties of small radiotherapy photon fields
    • A. Scott, A.E. Nahum, and J.D. Fenwich Using a Monte Carlo model to predict dosimetric properties of small radiotherapy photon fields Med Phys 35 2008 4671 4684
    • (2008) Med Phys , vol.35 , pp. 4671-4684
    • Scott, A.1    Nahum, A.E.2    Fenwich, J.D.3
  • 21
    • 67649625514 scopus 로고    scopus 로고
    • Monte Carlo modeling of small photon fields: Quantifying the impact of focal spot size on source occlusion and output ratios, and exploring miniphantom design for small-field measurements
    • A. Scott, A.E. Nahum, and J.D. Fenwich Monte Carlo modeling of small photon fields: quantifying the impact of focal spot size on source occlusion and output ratios, and exploring miniphantom design for small-field measurements Med Phys 36 2009 3132 3144
    • (2009) Med Phys , vol.36 , pp. 3132-3144
    • Scott, A.1    Nahum, A.E.2    Fenwich, J.D.3
  • 22
    • 79960214850 scopus 로고    scopus 로고
    • Experimental comparison of seven commercial dosimetry diodes for measurement of stereotactic radiosurgery cone factors
    • S. Dieterich, and G.W. Sherouse Experimental comparison of seven commercial dosimetry diodes for measurement of stereotactic radiosurgery cone factors Med Phys 38 2011 4166 4173
    • (2011) Med Phys , vol.38 , pp. 4166-4173
    • Dieterich, S.1    Sherouse, G.W.2
  • 23
    • 2642710922 scopus 로고    scopus 로고
    • Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams
    • DOI 10.1088/0031-9155/43/1/002, PII S0031915598852640
    • A. Dau, P.O. Lofroth, and G. Wickman Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams Phys Med Biol 43 1998 21 36 (Pubitemid 28103708)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.1 , pp. 21-36
    • Dasu, A.1    Lofroth, P.-O.2    Wickman, G.3
  • 24
    • 0032829872 scopus 로고    scopus 로고
    • Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition
    • DOI 10.1088/0031-9155/44/9/303, PII S0031915599005382
    • C. McKerracher, and D.I. Thwaites Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition Phys Med Biol 44 1999 2143 2160 (Pubitemid 29424376)
    • (1999) Physics in Medicine and Biology , vol.44 , Issue.9 , pp. 2143-2160
    • McKerracher, C.1    Thwaites, D.I.2
  • 25
    • 54949105889 scopus 로고    scopus 로고
    • A new formalism for reference dosimetry of small and nonstandard fields
    • R. Alfonso, P. Andreo, and R. Capote A new formalism for reference dosimetry of small and nonstandard fields Med Phys 35 2008 5179 5186
    • (2008) Med Phys , vol.35 , pp. 5179-5186
    • Alfonso, R.1    Andreo, P.2    Capote, R.3
  • 26
    • 38849151519 scopus 로고    scopus 로고
    • Total scatter factors of small beams: A multidetector and Monte Carlo study
    • DOI 10.1118/1.2828195
    • P. Francescon, S. Cora, and C. Cavedon Total scatter ratios of small beams: a multidetector and Monte Carlo study Med Phys 35 2008 504 513 (Pubitemid 351190870)
    • (2008) Medical Physics , vol.35 , Issue.2 , pp. 504-513
    • Francescon, P.1    Cora, S.2    Cavedon, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.