-
2
-
-
37549052531
-
Small fields: Nonequilibrium radiation dosimetry
-
I.J. Das, G.X. Ding, and A. Ahnesjo Small fields: nonequilibrium radiation dosimetry Med Phys 35 2008 206 215
-
(2008)
Med Phys
, vol.35
, pp. 206-215
-
-
Das, I.J.1
Ding, G.X.2
Ahnesjo, A.3
-
3
-
-
0037339773
-
The volume effect of detectors in the dosimetry of small fields used in IMRT
-
DOI 10.1118/1.1544678
-
W.U. Laud, and T. Wong The volume effect of detectors in the dosimetry of small fields used in IMRT Med Phys 30 2003 341 347 (Pubitemid 36337100)
-
(2003)
Medical Physics
, vol.30
, Issue.3
, pp. 341-347
-
-
Lauba, W.U.1
Wong, T.2
-
4
-
-
0038497899
-
An investigation of the photon energy dependence of the EPR alanine dosimetry system
-
DOI 10.1088/0031-9155/48/12/306, PII S0031915503574929
-
E.S. Bergstrand, K.R. Shortt, C.H. Ross, and E.O. Hole An investigation of the photon energy dependence of the EPR alanine dosimetry system Phys Med Biol 48 2003 1753 1771 (Pubitemid 36805848)
-
(2003)
Physics in Medicine and Biology
, vol.48
, Issue.12
, pp. 1753-1771
-
-
Bergstrand, E.S.1
Shortt, K.R.2
Ross, C.K.3
Hole, E.O.4
-
5
-
-
10644227698
-
K-band EPR dosimetry: Small-field beam profile determination with miniature alanine dosimeter
-
DOI 10.1016/j.apradiso.2004.08.036, PII S0969804304004713
-
F. Chen, C.F. Graeff, and O. Baffa K-band EPR dosimetry: small-field beam profile determination with miniature alanine dosimeter Appl Radiat Isot 62 2005 267 271 (Pubitemid 39655667)
-
(2005)
Applied Radiation and Isotopes
, vol.62
, Issue.SPEC. ISS.
, pp. 267-271
-
-
Chen, F.1
Graeff, C.F.O.2
Baffa, O.3
-
6
-
-
0026804696
-
Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations
-
A.S. Beddar, T.R. Mackie, and F.H. Attix Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations Phys Med Biol 37 1992 1883 1900
-
(1992)
Phys Med Biol
, vol.37
, pp. 1883-1900
-
-
Beddar, A.S.1
MacKie, T.R.2
Attix, F.H.3
-
7
-
-
45749136904
-
Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide
-
DOI 10.1088/0031-9155/53/11/021, PII S0031915508750449
-
J. Lambert, Y. Yin, and D.R. McKenzie Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide Phys Med Biol 53 2008 3071 3080 (Pubitemid 351868624)
-
(2008)
Physics in Medicine and Biology
, vol.53
, Issue.11
, pp. 3071-3080
-
-
Lambert, J.1
Yin, Y.2
McKenzie, D.R.3
Law, S.4
Suchowerska, N.5
-
8
-
-
77957705127
-
Measuring output ratios of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors
-
D.M. Klein, R.C. Tailor, and L. Archambault Measuring output ratios of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors Med Phys 37 2010 5541 5549
-
(2010)
Med Phys
, vol.37
, pp. 5541-5549
-
-
Klein, D.M.1
Tailor, R.C.2
Archambault, L.3
-
9
-
-
79952137211
-
Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations
-
L.L.W. Wang, and S. Beddar Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations Med Phys 38 2011 1596 1599
-
(2011)
Med Phys
, vol.38
, pp. 1596-1599
-
-
Wang, L.L.W.1
Beddar, S.2
-
10
-
-
36349023169
-
Head scatter factors for small MV photon fields. Part II: The effects of source size and detector
-
DOI 10.1016/j.radonc.2007.09.006, PII S0167814007004616
-
C. McKerracher, and D.I. Thwaites Head scatter ratios for small MV photon fields. Part II: The effects of source size and detector Radiother Oncol 85 2007 286 291 (Pubitemid 350161011)
-
(2007)
Radiotherapy and Oncology
, vol.85
, Issue.2
, pp. 286-291
-
-
McKerracher, C.1
Thwaites, D.I.2
-
11
-
-
34447336432
-
Measurement of output factors for small photon beams
-
DOI 10.1118/1.2734383
-
O.A. Sauer, and J. Wilbert Measurement of output ratios for small photon fields Med Phys 34 2007 1983 1988 (Pubitemid 47055733)
-
(2007)
Medical Physics
, vol.34
, Issue.6
, pp. 1983-1988
-
-
Sauer, O.A.1
Wilbert, J.2
-
12
-
-
36348947412
-
Head scatter factors for small MV photon fields. Part I: A comparison of phantom types and methodologies
-
DOI 10.1016/j.radonc.2007.09.005, PII S0167814007004604
-
C. McKerracher, and D.I. Thwaites Head scatter ratios for small MV photon fields. Part I: A comparison of phantom types and methodologies Radiother Oncol 85 2007 277 285 (Pubitemid 350161010)
-
(2007)
Radiotherapy and Oncology
, vol.85
, Issue.2
, pp. 277-285
-
-
McKerracher, C.1
Thwaites, D.I.2
-
13
-
-
38949117985
-
Phantom scatter factors for small MV photon fields
-
DOI 10.1016/j.radonc.2007.10.040, PII S0167814007005506
-
C. McKerracher, and D.I. Thwaites Phantom scatter ratios for small MV photon fields Radiother Oncol 86 2008 272 275 (Pubitemid 351215202)
-
(2008)
Radiotherapy and Oncology
, vol.86
, Issue.2
, pp. 272-275
-
-
McKerracher, C.1
Thwaites, D.I.2
-
14
-
-
3142711454
-
A new approach in dose measurement and error analysis for narrow photon beams (beamlets) shaped by different multileaf collimators using a small detector
-
DOI 10.1118/1.1760191
-
S. Li, A. Rashid, S. He, and D. Djajaputra A new approach in dose measurement and error analysis for narrow photon beams (beamlets) shaped by different multileaf collimators using a small detector Med Phys 31 2004 2020 2032 (Pubitemid 38924822)
-
(2004)
Medical Physics
, vol.31
, Issue.7
, pp. 2020-2032
-
-
Li, S.1
Rashid, A.2
He, S.3
Djajaputra, D.4
-
15
-
-
33645009141
-
Dosimetric characteristics of a new unshielded silicon diode and its application in clinical photon and electron beams
-
I. Griessbach, M. Lapp, G. Gademann, and D. Harder Dosimetric characteristics of a new unshielded silicon diode and its application in clinical photon and electron beams Med Phys 32 2005 3750 3754
-
(2005)
Med Phys
, vol.32
, pp. 3750-3754
-
-
Griessbach, I.1
Lapp, M.2
Gademann, G.3
Harder, D.4
-
16
-
-
33746211628
-
Notes on the construction of solid-state detectors
-
DOI 10.1016/j.radonc.2006.05.008, PII S0167814006002052
-
C. McKerracher, and D.I. Thwaites Notes on the construction of solid-state detectors Radiother Oncol 79 2006 348 351 (Pubitemid 44093763)
-
(2006)
Radiotherapy and Oncology
, vol.79
, Issue.3
, pp. 348-351
-
-
McKerracher, C.1
Thwaites, D.I.2
-
19
-
-
0037701288
-
Focal spot motion of linear accelerators and its effect on portal image analysis
-
DOI 10.1118/1.1576229
-
J.J. Sonke, B. Brand, and M. van Herk Focal spot motion of linear accelerators and its effect on portal image analysis Med Phys 30 2003 1067 1075 (Pubitemid 36735972)
-
(2003)
Medical Physics
, vol.30
, Issue.6
, pp. 1067-1075
-
-
Sonke, J.-J.1
Brand, B.2
Van Herk, M.3
-
20
-
-
52949151876
-
Using a Monte Carlo model to predict dosimetric properties of small radiotherapy photon fields
-
A. Scott, A.E. Nahum, and J.D. Fenwich Using a Monte Carlo model to predict dosimetric properties of small radiotherapy photon fields Med Phys 35 2008 4671 4684
-
(2008)
Med Phys
, vol.35
, pp. 4671-4684
-
-
Scott, A.1
Nahum, A.E.2
Fenwich, J.D.3
-
21
-
-
67649625514
-
Monte Carlo modeling of small photon fields: Quantifying the impact of focal spot size on source occlusion and output ratios, and exploring miniphantom design for small-field measurements
-
A. Scott, A.E. Nahum, and J.D. Fenwich Monte Carlo modeling of small photon fields: quantifying the impact of focal spot size on source occlusion and output ratios, and exploring miniphantom design for small-field measurements Med Phys 36 2009 3132 3144
-
(2009)
Med Phys
, vol.36
, pp. 3132-3144
-
-
Scott, A.1
Nahum, A.E.2
Fenwich, J.D.3
-
22
-
-
79960214850
-
Experimental comparison of seven commercial dosimetry diodes for measurement of stereotactic radiosurgery cone factors
-
S. Dieterich, and G.W. Sherouse Experimental comparison of seven commercial dosimetry diodes for measurement of stereotactic radiosurgery cone factors Med Phys 38 2011 4166 4173
-
(2011)
Med Phys
, vol.38
, pp. 4166-4173
-
-
Dieterich, S.1
Sherouse, G.W.2
-
23
-
-
2642710922
-
Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams
-
DOI 10.1088/0031-9155/43/1/002, PII S0031915598852640
-
A. Dau, P.O. Lofroth, and G. Wickman Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams Phys Med Biol 43 1998 21 36 (Pubitemid 28103708)
-
(1998)
Physics in Medicine and Biology
, vol.43
, Issue.1
, pp. 21-36
-
-
Dasu, A.1
Lofroth, P.-O.2
Wickman, G.3
-
24
-
-
0032829872
-
Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition
-
DOI 10.1088/0031-9155/44/9/303, PII S0031915599005382
-
C. McKerracher, and D.I. Thwaites Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition Phys Med Biol 44 1999 2143 2160 (Pubitemid 29424376)
-
(1999)
Physics in Medicine and Biology
, vol.44
, Issue.9
, pp. 2143-2160
-
-
McKerracher, C.1
Thwaites, D.I.2
-
25
-
-
54949105889
-
A new formalism for reference dosimetry of small and nonstandard fields
-
R. Alfonso, P. Andreo, and R. Capote A new formalism for reference dosimetry of small and nonstandard fields Med Phys 35 2008 5179 5186
-
(2008)
Med Phys
, vol.35
, pp. 5179-5186
-
-
Alfonso, R.1
Andreo, P.2
Capote, R.3
-
26
-
-
38849151519
-
Total scatter factors of small beams: A multidetector and Monte Carlo study
-
DOI 10.1118/1.2828195
-
P. Francescon, S. Cora, and C. Cavedon Total scatter ratios of small beams: a multidetector and Monte Carlo study Med Phys 35 2008 504 513 (Pubitemid 351190870)
-
(2008)
Medical Physics
, vol.35
, Issue.2
, pp. 504-513
-
-
Francescon, P.1
Cora, S.2
Cavedon, C.3
|