메뉴 건너뛰기




Volumn 13, Issue 5, 2011, Pages 909-922

Design and integration of a generic disposable array-compatible sensor housing into an integrated disposable indirect microfluidic flow injection analysis system

Author keywords

Biosensors; Flow injection analysis; Microfluidic polymer chip; Microfluidics; Surface acoustic wave

Indexed keywords

BIOANALYTICAL APPLICATIONS; BIOMEDICAL APPLICATIONS; BIOSENSING; COMPARATIVE MEASUREMENTS; COMPATIBLE POLYMERS; END USERS; FLOW INJECTION ANALYSIS; INTEGRATION STRATEGY; MICRO FLUIDIC SYSTEM; MICROFLUIDIC CHIP; MICROFLUIDIC FLOW; REUSABLE COMPONENTS; SAMPLE VOLUME; SENSOR SYSTEMS; SURFACE ACOUSTIC WAVE; SURFACE ACOUSTIC WAVE SENSORS; TETRADECANE;

EID: 80053929297     PISSN: 13872176     EISSN: 15728781     Source Type: Journal    
DOI: 10.1007/s10544-011-9560-4     Document Type: Article
Times cited : (15)

References (25)
  • 1
    • 3042698106 scopus 로고    scopus 로고
    • Improvement of surface acoustic wave gas and biosensor response characteristics using a capacitive coupling technique
    • DOI 10.1021/ac035019+
    • F Bender K Länge A Voigt M Rapp 2004 Anal Chem 76 3837 3840 10.1021/ac035019+ (Pubitemid 38868852)
    • (2004) Analytical Chemistry , vol.76 , Issue.13 , pp. 3837-3840
    • Bender, F.1    Lange, K.2    Voigt, A.3    Rapp, M.4
  • 2
    • 21844436824 scopus 로고    scopus 로고
    • Developments in biosensors - Where are tomorrow's markets?
    • DOI 10.1108/02602280510606426
    • R Bogue 2005 Sens Rev 25 180 184 10.1108/02602280510606426 (Pubitemid 40952277)
    • (2005) Sensor Review , vol.25 , Issue.3 , pp. 180-184
    • Bogue, R.1
  • 6
    • 33748348843 scopus 로고    scopus 로고
    • An integrated microfluidic chip for DNA/RNA amplification, electrophoresis separation and on-line optical detection
    • DOI 10.1002/elps.200600458
    • H Fu-Chun L Chia-Sheng L Gwo-Bin 2006 Electrophoresis 27 3297 3305 10.1002/elps.200600458 (Pubitemid 44336017)
    • (2006) Electrophoresis , vol.27 , Issue.16 , pp. 3297-3305
    • Huang, F.-C.1    Liao, C.-S.2    Lee, G.-B.3
  • 8
    • 14644411718 scopus 로고    scopus 로고
    • Monitoring complex formation in the blood-coagulation cascade using aptamer-coated SAW sensors
    • DOI 10.1016/j.bios.2004.09.007, PII S0956566304004178
    • TMA Gronewold S Glass E Quandt A Famulok 2005 Biosens Bioelectron 20 2044 2052 10.1016/j.bios.2004.09.007 (Pubitemid 40312101)
    • (2005) Biosensors and Bioelectronics , vol.20 , Issue.10 SPEC. ISS. , pp. 2044-2052
    • Gronewold, T.M.A.1    Glass, S.2    Quandt, E.3    Famulok, M.4
  • 13
    • 18744428328 scopus 로고    scopus 로고
    • A Surface Acoustic Wave Biosensor Concept with Low Flow Cell Volumes for Label-Free Detection
    • DOI 10.1021/ac0207574
    • K Länge F Bender A Voigt H Gao M Rapp 2003 Anal Chem 75 5561 5566 10.1021/ac0207574 (Pubitemid 37280587)
    • (2003) Analytical Chemistry , vol.75 , Issue.20 , pp. 5561-5566
    • Lange, K.1    Bender, F.2    Voigt, A.3    Gao, H.4    Rapp, M.5
  • 14
    • 33747373852 scopus 로고    scopus 로고
    • Integration of a surface acoustic wave biosensor in a microfluidic polymer chip
    • DOI 10.1016/j.bios.2005.12.026, PII S0956566306000078
    • K Länge G Blaess A Voigt R Götzen M Rapp 2006 Biosens Bioelectron 22 227 232 10.1016/j.bios.2005.12.026 (Pubitemid 44247615)
    • (2006) Biosensors and Bioelectronics , vol.22 , Issue.2 , pp. 227-232
    • Lange, K.1    Blaess, G.2    Voigt, A.3    Gotzen, R.4    Rapp, M.5
  • 15
    • 34447618953 scopus 로고    scopus 로고
    • Chemical modification of parylene C coatings for SAW biosensors
    • DOI 10.1016/j.snb.2007.02.039, PII S0925400507001451
    • K Länge S Grimm M Rapp 2007 Sens Actuators B 125 441 446 10.1016/j.snb.2007.02.039 (Pubitemid 47095222)
    • (2007) Sensors and Actuators, B: Chemical , vol.125 , Issue.2 , pp. 441-446
    • Lange, K.1    Grimm, S.2    Rapp, M.3
  • 19
    • 33747833771 scopus 로고    scopus 로고
    • Impedance spectroscopy: Over 35 years of electrochemical sensor optimization
    • DOI 10.1016/j.electacta.2006.04.025, PII S0013468606004944
    • B Pejcic R De Marco 2006 Electrochim Acta 51 6217 6229 10.1016/j.electacta.2006.04.025 (Pubitemid 44286814)
    • (2006) Electrochimica Acta , vol.51 , Issue.28 , pp. 6217-6229
    • Pejcic, B.1    De Marco, R.2
  • 22
    • 0032535499 scopus 로고    scopus 로고
    • Influence of phase position on the performance of chemical sensors based on SAW device oscillators
    • DOI 10.1021/ac9805504
    • J Reibel S Stier A Voigt M Rapp 1998 Anal Chem 70 5190 5197 10.1021/ac9805504 (Pubitemid 29011058)
    • (1998) Analytical Chemistry , vol.70 , Issue.24 , pp. 5190-5197
    • Reibel, J.1    Stier, S.2    Voigt, A.3    Rapp, M.4
  • 23
    • 84873086275 scopus 로고
    • edn, Wiley
    • J. Růžička, E.H. Hansen, edn, Wiley (1981)
    • (1981)
    • Růžička, J.1
  • 24
    • 0032508847 scopus 로고    scopus 로고
    • Convection and diffusion in a micro-flow injection system
    • DOI 10.1016/S0003-2670(98)00381-X, PII S000326709800381X
    • EB van Akker M Bos WE van der Linden 1998 Anal Chim Acta 373 227 239 10.1016/S0003-2670(98)00381-X (Pubitemid 28448812)
    • (1998) Analytica Chimica Acta , vol.373 , Issue.2-3 , pp. 227-239
    • Van Akker, E.B.1    Bos, M.2    Van Der Linden, W.E.3
  • 25
    • 23144452296 scopus 로고    scopus 로고
    • Automatic bio-sampling chips integrated with micro-pumps and micro-valves for disease detection
    • DOI 10.1016/j.bios.2004.11.004, PII S0956566304005457
    • C-H Wang G-B Lee 2005 Biosens Bioelectron 21 419 425 05548279 10.1016/j.bios.2004.11.004 (Pubitemid 41078785)
    • (2005) Biosensors and Bioelectronics , vol.21 , Issue.3 , pp. 419-425
    • Wang, C.-H.1    Lee, G.-B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.