메뉴 건너뛰기




Volumn 56, Issue 20, 2011, Pages 6523-6543

Automated quantification of three-dimensional subject motion to monitor image quality in high-resolution peripheral quantitative computed tomography

Author keywords

[No Author keywords available]

Indexed keywords

AUTOMATED METHODS; AUTOMATED TECHNIQUES; AUTOMATIC METHOD; BONE ARCHITECTURE; BONE MINERAL DENSITY; BONE QUALITY; CORTICAL THICKNESS; HIGH QUALITY IMAGES; HIGH RESOLUTION; HUMAN CADAVER; IMAGE ARTIFACTS; IMAGING MODALITY; IN-PLANE; INPLANE ROTATION; LONGITUDINAL MOVEMENTS; MECHANICAL DEVICE; MORPHOLOGICAL PARAMETERS; MOTION ARTIFACT; PARAMETER ERROR; PHYSICAL MOTION; PROJECTION DATA; PROJECTION PROFILE; QUANTITATIVE COMPUTED TOMOGRAPHIES; TRANSLATIONAL MOTIONS;

EID: 80053602431     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/56/20/001     Document Type: Article
Times cited : (26)

References (26)
  • 1
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland J M and Altman D G 1986 Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 307-10 (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 2
    • 27944449749 scopus 로고    scopus 로고
    • In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography
    • DOI 10.1210/jc.2005-1258
    • Boutroy S, Bouxsein M L, Munoz F and Delmas P D 2005 In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography J. Clin. Endocrinol. Metab. 90 6508-15 (Pubitemid 41759306)
    • (2005) Journal of Clinical Endocrinology and Metabolism , vol.90 , Issue.12 , pp. 6508-6515
    • Boutroy, S.1    Bouxsein, M.L.2    Munoz, F.3    Delmas, P.D.4
  • 3
    • 77955845468 scopus 로고    scopus 로고
    • Reproducibility of direct quantitative measures of cortical bone microarchitecture of the distal radius and tibia by HR-pQCT
    • Burghardt A J, Buie H R, Laib A, Majumdar S and Boyd S K 2010 Reproducibility of direct quantitative measures of cortical bone microarchitecture of the distal radius and tibia by HR-pQCT Bone 47 519-28
    • (2010) Bone , vol.47 , pp. 519-528
    • Burghardt, A.J.1    Buie, H.R.2    Laib, A.3    Majumdar, S.4    Boyd, S.K.5
  • 4
    • 78649556809 scopus 로고    scopus 로고
    • A longitudinal HR-pQCT study of alendronate treatment in postmenopausal women with low bone density: Relations among density, cortical and trabecular microarchitecture, biomechanics, and bone turnover
    • Burghardt A J, Kazakia G J, Sode M, de Papp A E, Link T M and Majumdar S 2010 A longitudinal HR-pQCT study of alendronate treatment in postmenopausal women with low bone density: relations among density, cortical and trabecular microarchitecture, biomechanics, and bone turnover J. Bone Miner. Res. 25 2558-71
    • (2010) J. Bone Miner. Res. , vol.25 , pp. 2558-2571
    • Burghardt, A.J.1    Kazakia, G.J.2    Sode, M.3    De Papp, A.E.4    Link, T.M.5    Majumdar, S.6
  • 6
    • 0036464430 scopus 로고    scopus 로고
    • A hybrid 3-D reconstruction/registration algorithm for correction of head motion in emission tomography
    • DOI 10.1109/TNS.2002.998750, PII S0018949902016441
    • Hutton B F, Kyme A Z, Lau Y H, Skerett D W and Fulton R R 2002 A hybrid 3-d reconstruction/registration algorithm for correction of head motion in emission tomography IEEE Trans. Nucl. Sci. 49 188-94 (Pubitemid 34658216)
    • (2002) IEEE Transactions on Nuclear Science , vol.49 , Issue.1 , pp. 188-194
    • Hutton, B.F.1    Kyme, A.Z.2    Lau, Y.H.3    Skerrett, D.W.4    Fulton, R.R.5
  • 10
  • 11
    • 0344141607 scopus 로고    scopus 로고
    • Comparison of structure extraction methods for in vivo trabecular bone measurements
    • DOI 10.1016/S0895-6111(98)00071-8, PII S0895611198000718
    • Laib A and Rüegsegger P 1999 Comparison of structure extraction methods for in vivo trabecular bone measurements Comput. Med. Imaging Graph. 23 69-74 (Pubitemid 29181634)
    • (1999) Computerized Medical Imaging and Graphics , vol.23 , Issue.2 , pp. 69-74
    • Laib, A.1    Ruegsegger, P.2
  • 12
    • 0037149991 scopus 로고    scopus 로고
    • Tomographic motion detection and correction directly in sinogram space
    • DOI 10.1088/0031-9155/47/8/304, PII S0031915502332433
    • Lu W and Mackie T R 2002 Tomographic motion detection and correction directly in sinogram space Phys. Med. Biol. 47 1267-84 (Pubitemid 34495625)
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.8 , pp. 1267-1284
    • Lu, W.1    Mackie, T.R.2
  • 13
    • 43149096685 scopus 로고    scopus 로고
    • Bone strength at the distal radius can be estimated from high-resolution peripheral quantitative computed tomography and the finite element method
    • MacNeil J A and Boyd S K 2008a Bone strength at the distal radius can be estimated from high-resolution peripheral quantitative computed tomography and the finite element method Bone 42 1203-13
    • (2008) Bone , vol.42 , pp. 1203-1213
    • MacNeil, J.A.1    Boyd, S.K.2
  • 14
    • 43149083839 scopus 로고    scopus 로고
    • Improved reproducibility of high resolution peripheral quantitative computed tomography for measurement of bone quality
    • MacNeil J A and Boyd S K 2008b Improved reproducibility of high resolution peripheral quantitative computed tomography for measurement of bone quality Med. Eng. Phys. 30 792-9
    • (2008) Med. Eng. Phys. , vol.30 , pp. 792-799
    • MacNeil, J.A.1    Boyd, S.K.2
  • 20
    • 77955559627 scopus 로고    scopus 로고
    • Strontium ranelate and alendronate have differing effects on distal tibia bone microstructure in women with osteoporosis
    • Rizzoli R, Laroche M, Krieg M, Frieling I, Thomas T, Delmas P D and Felsenberg D 2010 Strontium ranelate and alendronate have differing effects on distal tibia bone microstructure in women with osteoporosis Rheumatol. Int. 30 1341-8
    • (2010) Rheumatol. Int. , vol.30 , pp. 1341-1348
    • Rizzoli, R.1    Laroche, M.2    Krieg, M.3    Frieling, I.4    Thomas, T.5    Delmas, P.D.6    Felsenberg, D.7
  • 21
    • 33746231767 scopus 로고    scopus 로고
    • Motion compensation for cone-beam CT based on 4D motion field of sinogram tracked markers
    • Schäfer D, Bertram M, Conrads N, Wiegert J, Rose G and Rasche V 2004 Motion compensation for cone-beam CT based on 4D motion field of sinogram tracked markers CARS 2004 - Computer Assisted Radiology and Surgery. Proc. 18th Int. Congress and Exhibition Int. Congr. Ser. 1268 189-94
    • (2004) Int. Congr. Ser. , vol.1268 , pp. 189-194
    • Schäfer, D.1    Bertram, M.2    Conrads, N.3    Wiegert, J.4    Rose, G.5    Rasche, V.6
  • 22
    • 77953715717 scopus 로고    scopus 로고
    • Microarchitectural deterioration of cortical and trabecular bone: Differing effects of denosumab and alendronate
    • Seeman E et al 2010 Microarchitectural deterioration of cortical and trabecular bone: differing effects of denosumab and alendronate J. Bone Miner. Res. 25 1886-94
    • (2010) J. Bone Miner. Res. , vol.25 , pp. 1886-1894
    • Seeman, E.1
  • 23
    • 79955894200 scopus 로고    scopus 로고
    • Quantitative characterization of subject motion in HR-pQCT images of the distal radius and tibia
    • Sode M, Burghardt A J, Pialat J, Link T M and Majumdar S 2011 Quantitative characterization of subject motion in HR-pQCT images of the distal radius and tibia Bone 48 1291-7
    • (2011) Bone , vol.48 , pp. 1291-1297
    • Sode, M.1    Burghardt, A.J.2    Pialat, J.3    Link, T.M.4    Majumdar, S.5
  • 24
    • 34247197697 scopus 로고    scopus 로고
    • Alterations of cortical and trabecular architecture are associated with fractures in postmenopausal women, partially independent of decreased BMD measured by DXA: The OFELY study
    • DOI 10.1359/jbmr.061206
    • Sornay-Rendu E, Boutroy S, Munoz F and Delmas P D 2007 Alterations of cortical and trabecular architecture are associated with fractures in postmenopausal women, partially independent of decreased BMD measured by DXA: the OFELY study J. Bone Miner. Res. 22 425-33 (Pubitemid 46797126)
    • (2007) Journal of Bone and Mineral Research , vol.22 , Issue.3 , pp. 425-433
    • Sornay-Rendu, E.1    Boutroy, S.2    Munoz, F.3    Delmas, P.D.4
  • 25
    • 33847637154 scopus 로고    scopus 로고
    • Data consistency based rigid motion artifact reduction in fan-beam CT
    • DOI 10.1109/TMI.2006.889717
    • Yu H and Wang G 2007 Data consistency based rigid motion artifact reduction in fan-beam CT IEEE Trans. Med. Imaging 26 249-60 (Pubitemid 46362767)
    • (2007) IEEE Transactions on Medical Imaging , vol.26 , Issue.2 , pp. 249-260
    • Yu, H.1    Wang, G.2
  • 26
    • 33746617610 scopus 로고    scopus 로고
    • Data consistency based translational motion artifact reduction in fan-beam CT
    • DOI 10.1109/TMI.2006.875424, 1637536
    • Yu H, Wei Y, Hsieh J and Wang G 2006 Data consistency based translational motion artifact reduction in fan-beam CT IEEE Trans. Med. Imaging 25 792-803 (Pubitemid 44143895)
    • (2006) IEEE Transactions on Medical Imaging , vol.25 , Issue.6 , pp. 792-803
    • Yu, H.1    Wei, Y.2    Hsieh, J.3    Wang, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.