메뉴 건너뛰기




Volumn 6, Issue 4, 2011, Pages 477-489

Dialysis grafts and fistulae: Planning and assessment

Author keywords

Arteriovenous fistula; Arteriovenous graft; Hemodialysis access; Preoperative ultrasound mapping; Ultrasound

Indexed keywords

ARTERIOVENOUS FISTULA; ARTERY OCCLUSION; ARTICLE; BLOOD FLOWMETRY; COLOR ULTRASOUND FLOWMETRY; DOPPLER ECHOGRAPHY; ECHOGRAPHY; GRAY SCALE ECHOGRAPHY; HEMODIALYSIS; HUMAN; PRIORITY JOURNAL; SPECTRAL DOPPLER; VASCULAR ACCESS;

EID: 80053596379     PISSN: 1556858X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cult.2011.07.004     Document Type: Review
Times cited : (13)

References (41)
  • 1
    • 70349393145 scopus 로고    scopus 로고
    • U.S. Renal Data System, USRDS 2010 Annual Data Report National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Diseases Bethesda (MD)
    • U.S. Renal Data System, USRDS 2010 Annual Data Report Atlas of chronic kidney disease and end-stage renal disease in the United States 2010 National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Diseases Bethesda (MD)
    • (2010) Atlas of Chronic Kidney Disease and End-stage Renal Disease in the United States
  • 3
    • 33845807146 scopus 로고    scopus 로고
    • KDOQI clinical practice guidelines and clinical practice recommendations for vascular access 2006
    • KDOQI clinical practice guidelines and clinical practice recommendations for vascular access 2006 Am J Kidney Dis 48 Suppl 1 2006 S176 S322
    • (2006) Am J Kidney Dis , vol.48 , Issue.SUPPL. 1
  • 5
    • 0036189126 scopus 로고    scopus 로고
    • Epidemiology of hemodialysis vascular access infections from longitudinal infection surveillance data: Predicting the impact of NKF-DOQI clinical practice guidelines for vascular access
    • DOI 10.1053/ajkd.2002.31405
    • K.B. Stevenson, E.L. Hannah, and C.A. Lowder Epidemiology of hemodialysis vascular access infections from longitudinal infection surveillance data: predicting the impact of NKF-DOQI clinical practice guidelines for vascular access Am J Kidney Dis 39 2002 549 555 (Pubitemid 34194631)
    • (2002) American Journal of Kidney Diseases , vol.39 , Issue.3 , pp. 549-555
    • Stevenson, K.B.1    Hannah, E.L.2    Lowder, C.A.3    Adcox, M.J.4    Davidson, R.L.5    Mallea, M.C.6    Narasimhan, N.7    Wagnild, J.P.8
  • 6
    • 0031881670 scopus 로고    scopus 로고
    • A strategy for increasing use of autogenous hemodialysis access procedures: Impact of preoperative noninvasive evaluation
    • M.B. Silva Jr., R.W. Hobson 2nd, and P.J. Pappas A strategy for increasing use of autogenous hemodialysis access procedures: impact of preoperative noninvasive evaluation J Vasc Surg 27 1998 302 307
    • (1998) J Vasc Surg , vol.27 , pp. 302-307
    • Silva Jr., M.B.1    Hobson II, R.W.2    Pappas, P.J.3
  • 10
    • 0036787350 scopus 로고    scopus 로고
    • Hemodialysis arteriovenous fistula maturity: US evaluation
    • M.L. Robbin, N.E. Chamberlain, and M.E. Lockhart Hemodialysis arteriovenous fistula maturity: US evaluation Radiology 225 2002 59 64
    • (2002) Radiology , vol.225 , pp. 59-64
    • Robbin, M.L.1    Chamberlain, N.E.2    Lockhart, M.E.3
  • 12
    • 0029048657 scopus 로고
    • Utility of intraaccess pressure monitoring in detecting and correcting venous outlet stenoses before thrombosis
    • A. Besarab, K.L. Sullivan, and R.P. Ross Utility of intraaccess pressure monitoring in detecting and correcting venous outlet stenoses before thrombosis Kidney Int 47 1995 1364 1373
    • (1995) Kidney Int , vol.47 , pp. 1364-1373
    • Besarab, A.1    Sullivan, K.L.2    Ross, R.P.3
  • 15
    • 0026539960 scopus 로고
    • The effect of Doppler flow screening studies and elective revisions on dialysis access failure
    • J. Sands, S. Young, and C. Miranda The effect of Doppler flow screening studies and elective revisions on dialysis access failure ASAIO J 38 1992 M524 M527
    • (1992) ASAIO J , vol.38
    • Sands, J.1    Young, S.2    Miranda, C.3
  • 16
    • 0029936196 scopus 로고    scopus 로고
    • Detection and treatment of dysfunctional hemodialysis access grafts: Effect of a surveillance program on graft patency and the incidence of thrombosis
    • A.A. Safa, K. Valji, and A.C. Roberts Detection and treatment of dysfunctional hemodialysis access grafts: effects of a surveillance program on graft patency and the incidence of thrombosis Radiology 199 1996 653 657 (Pubitemid 26157461)
    • (1996) Radiology , vol.199 , Issue.3 , pp. 653-657
    • Safa, A.A.1    Valji, K.2    Roberts, A.C.3    Ziegler, T.W.4    Hye, R.J.5    Oglevie, S.B.6
  • 19
    • 32544454696 scopus 로고    scopus 로고
    • Randomized comparison of ultrasound surveillance and clinical monitoring on arteriovenous graft outcomes
    • DOI 10.1038/sj.ki.5000129, PII 5000129
    • M.L. Robbin, R.F. Oser, and J.Y. Lee Randomized comparison of ultrasound surveillance and clinical monitoring on arteriovenous graft outcomes Kidney Int 69 2006 730 735 (Pubitemid 43237643)
    • (2006) Kidney International , vol.69 , Issue.4 , pp. 730-735
    • Robbin, M.L.1    Oser, R.F.2    Lee, J.Y.3    Heudebert, G.R.4    Mennemeyer, S.T.5    Allon, M.6
  • 20
    • 0030885315 scopus 로고    scopus 로고
    • Prophylactic balloon angioplasty fails to prolong the patency of expanded polytetrafluoroethylene arteriovenous grafts: Results of a prospective randomized study
    • DOI 10.1016/S0741-5214(97)70031-4
    • A.B. Lumsden, M.J. MacDonald, and D. Kikeri Prophylactic balloon angioplasty fails to prolong the patency of expanded polytetrafluoroethylene arteriovenous grafts: results of a prospective randomized study J Vasc Surg 26 1997 382 392 (Pubitemid 27408553)
    • (1997) Journal of Vascular Surgery , vol.26 , Issue.3 , pp. 382-392
    • Lumsden, A.B.1    MacDonald, M.J.2    Kikeri, D.3    Cotsonis, G.A.4    Harker, L.A.5    Martin, L.G.6
  • 21
    • 0038468806 scopus 로고    scopus 로고
    • A randomized controlled trial of blood flow and stenosis surveillance of hemodialysis grafts
    • DOI 10.1046/j.1523-1755.2003.00070.x
    • S.J. Ram, J. Work, and G.C. Caldito A randomized controlled trial of blood flow and stenosis surveillance of hemodialysis grafts Kidney Int 64 2003 272 280 (Pubitemid 36714181)
    • (2003) Kidney International , vol.64 , Issue.1 , pp. 272-280
    • Ram, S.J.1    Work, J.2    Caldito, G.C.3    Eason, J.M.4    Pervez, A.5    Paulson, W.D.6
  • 22
    • 16244382028 scopus 로고    scopus 로고
    • Regular ultrasonographic screening significantly prolongs patency of PTFE grafts
    • DOI 10.1111/j.1523-1755.2005.00236.x
    • J. Malik, M. Slavikova, and J. Svobodova Regular ultrasound screening significantly prolongs patency of grafts Kidney Int 67 2005 1554 1558 (Pubitemid 40463135)
    • (2005) Kidney International , vol.67 , Issue.4 , pp. 1554-1558
    • Malik, J.1    Slavikova, M.2    Svobodova, J.3    Tuka, V.4
  • 23
    • 3042723504 scopus 로고    scopus 로고
    • Randomized controlled trial of prophylactic repair of hemodialysis arteriovenous graft stenosis
    • DOI 10.1111/j.1523-1755.2004.00743.x
    • L.M. Dember, E.F. Holmberg, and J.S. Kaufman Randomized controlled trial of prophylactic repair of hemodialysis arteriovenous graft stenosis Kidney Int 66 2004 390 398 (Pubitemid 38870117)
    • (2004) Kidney International , vol.66 , Issue.1 , pp. 390-398
    • Dember, L.M.1    Holmberg, E.F.2    Kaufman, J.S.3
  • 24
    • 37349120715 scopus 로고    scopus 로고
    • Clinically immature arteriovenous hemodialysis fistulas: Effect of US on salvage
    • DOI 10.1148/radiol.2463061942
    • P. Singh, M.L. Robbin, and M.E. Lockhart Clinically immature arteriovenous hemodialysis fistulas: effect of US on salvage Radiology 246 2008 299 305 (Pubitemid 350305056)
    • (2008) Radiology , vol.246 , Issue.1 , pp. 299-305
    • Singh, P.1    Robbin, M.L.2    Lockhart, M.E.3    Allon, M.4
  • 25
    • 33749521006 scopus 로고    scopus 로고
    • Early arteriovenous fistula failure: A logical proposal for how and when to intervene
    • A. Asif, P. Roy-Chadhury, and G.A. Beathard Early arteriovenous fistula failure: a logical proposal for how and when to intervene Clin J Am Soc Nephrol 1 2006 332 339
    • (2006) Clin J Am Soc Nephrol , vol.1 , pp. 332-339
    • Asif, A.1    Roy-Chadhury, P.2    Beathard, G.A.3
  • 28
    • 73949151316 scopus 로고    scopus 로고
    • Accuracy of volumetric flow rate measurements-an in vitro study using modern US scanners
    • K. Hoyt, F. Hester, and R. Bell Accuracy of volumetric flow rate measurements-an in vitro study using modern US scanners J Ultrasound Med 28 2009 1511 1518
    • (2009) J Ultrasound Med , vol.28 , pp. 1511-1518
    • Hoyt, K.1    Hester, F.2    Bell, R.3
  • 29
    • 0029130430 scopus 로고
    • An experimental study of the accuracy of volume flow measurements using commercial ultrasound systems
    • A.J. Winkler, J. Wu, and T. Case An experimental study of the accuracy of volume flow measurements using commercial ultrasound systems J Vasc Tech 19 1995 175 180
    • (1995) J Vasc Tech , vol.19 , pp. 175-180
    • Winkler, A.J.1    Wu, J.2    Case, T.3
  • 31
    • 0141674854 scopus 로고    scopus 로고
    • Aggressive treatment of early fistula failure
    • DOI 10.1046/j.1523-1755.2003.00210.x
    • G.A. Beathard, P. Arnold, and J. Jackson Aggressive treatment of early fistula failure. Physician Operators Forum of RMS Lifeline Kidney Int 64 2003 1487 1494 (Pubitemid 37153817)
    • (2003) Kidney International , vol.64 , Issue.4 , pp. 1487-1494
    • Beathard, G.A.1    Arnold, P.2    Jackson, J.3    Litchfield, T.4
  • 32
    • 70350569868 scopus 로고    scopus 로고
    • Brachial vein transposition arteriovenous fistulas for hemodialysis access
    • W.C. Jennings, M.J. Sideman, and K.E. Taubman Brachial vein transposition arteriovenous fistulas for hemodialysis access J Vasc Surg 50 2009 1121 1125
    • (2009) J Vasc Surg , vol.50 , pp. 1121-1125
    • Jennings, W.C.1    Sideman, M.J.2    Taubman, K.E.3
  • 33
    • 30844469996 scopus 로고    scopus 로고
    • Creating arteriovenous fistulas in 132 consecutive patients: Exploiting the proximal radial artery arteriovenous fistula: Reliable, safe, and simple forearm and upper arm hemodialysis access
    • DOI 10.1001/archsurg.141.1.27
    • W.C. Jennings Creating arteriovenous fistulas in 132 consecutive patients: exploiting the proximal radial artery arteriovenous fistula: reliable, safe, and simple forearm and upper arm hemodialysis access Arch Surg 141 2006 27 32 (Pubitemid 43107383)
    • (2006) Archives of Surgery , vol.141 , Issue.1 , pp. 27-32
    • Jennings, W.C.1
  • 34
    • 33846995460 scopus 로고    scopus 로고
    • Cephalic vein measurement before forearm fistula creation: Does use of a tourniquet to meet venous diameter threshold increase the number of useable fistulas?
    • M.E. Lockhart, M.L. Robbin, and N.S. Fineberg Cephalic vein measurement before forearm fistula creation: does use of a tourniquet to meet venous diameter threshold increase the number of useable fistulas? J Ultrasound Med 25 2006 1541 1545
    • (2006) J Ultrasound Med , vol.25 , pp. 1541-1545
    • Lockhart, M.E.1    Robbin, M.L.2    Fineberg, N.S.3
  • 35
    • 0033817968 scopus 로고    scopus 로고
    • Effects of intraoperative blood flow on the early patency of radiocephalic fistulas
    • T. Won, J.W. Jang, and S. Lee Effects of intraoperative blood flow on the early patency of radiocephalic fistulas Ann Vasc Surg 14 2000 468 472
    • (2000) Ann Vasc Surg , vol.14 , pp. 468-472
    • Won, T.1    Jang, J.W.2    Lee, S.3
  • 36
  • 39
    • 33745037734 scopus 로고    scopus 로고
    • Maintenance and salvage of arteriovenous fistulas
    • DOI 10.1097/01.RVI.0000217928.43396.35, PII 0000251820060500000009
    • A. Falk Maintenance and salvage of arteriovenous fistulas J Vasc Interv Radiol 17 2006 807 813 (Pubitemid 44378479)
    • (2006) Journal of Vascular and Interventional Radiology , vol.17 , Issue.5 , pp. 807-813
    • Falk, A.1
  • 40
    • 42249093676 scopus 로고    scopus 로고
    • Expected flow parameters within hemodialysis access and selection for remedial intervention of nonmaturing conduits
    • DOI 10.1177/1538574407312648
    • M.R. Back, M. Maynard, and A. Winkler Expected flow parameters within hemodialysis access and selection for remedial intervention of nonmaturing conduits Vasc Endovascular Surg 42 2008 150 158 (Pubitemid 351550920)
    • (2008) Vascular and Endovascular Surgery , vol.42 , Issue.2 , pp. 150-158
    • Back, M.R.1    Maynard, M.2    Winkler, A.3    Bandyk, D.F.4
  • 41
    • 0029129427 scopus 로고
    • Hand ischemia in patients with hemodialysis access grafts: Angiographic diagnosis and treatment
    • K. Valji, R.J. Hye, and A.C. Roberts Hand ischemia in patients with hemodialysis access grafts: angiographic diagnosis and treatment Radiology 196 1995 697 701
    • (1995) Radiology , vol.196 , pp. 697-701
    • Valji, K.1    Hye, R.J.2    Roberts, A.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.