메뉴 건너뛰기




Volumn 42, Issue 2, 2008, Pages 150-158

Expected flow parameters within hemodialysis access and selection for remedial intervention of nonmaturing conduits

Author keywords

Conduit flow rate; Duplex ultrasonography; Hemodialysis access; Hemodynamic parameters

Indexed keywords

ADULT; AGED; ARTERIOVENOUS FISTULA; ARTERY BLOOD FLOW; ARTICLE; BLOOD FLOW; BLOOD FLOW VELOCITY; CANNULATION; ECHOGRAPHY; FEMALE; GRAFT PATENCY; HEMODIALYSIS; HEMODYNAMICS; HUMAN; MAJOR CLINICAL STUDY; MALE; VASCULAR ACCESS; VEIN ANASTOMOSIS;

EID: 42249093676     PISSN: 15385744     EISSN: None     Source Type: Journal    
DOI: 10.1177/1538574407312648     Document Type: Article
Times cited : (52)

References (24)
  • 1
    • 0036736297 scopus 로고    scopus 로고
    • Prospective validation of an algorithm to maximize native arteriovenous fistulae for chronic hemodialysis access
    • Huber TS, Ozaki CK, Flynn TC, et al. Prospective validation of an algorithm to maximize native arteriovenous fistulae for chronic hemodialysis access. J Vasc Surg. 2002 ; 36: 452-459.
    • (2002) J Vasc Surg , vol.36 , pp. 452-459
    • Huber, T.S.1    Ozaki, C.K.2    Flynn, T.C.3
  • 2
    • 0036284040 scopus 로고    scopus 로고
    • Refinements in hemodialysis access construction using a new protocol for preoperative noninvasive evaluation of the upper extremity
    • Roper LD, Maynard MM, Johnson BL, Bandyk DF, Back MR Refinements in hemodialysis access construction using a new protocol for preoperative noninvasive evaluation of the upper extremity. J Vasc Technol. 2002 ; 26: 83-87.
    • (2002) J Vasc Technol , vol.26 , pp. 83-87
    • Roper, L.D.1    Maynard, M.M.2    Johnson, B.L.3    Bandyk, D.F.4    Back, M.R.5
  • 3
    • 0031881670 scopus 로고    scopus 로고
    • A strategy for increasing use of autogenous hemodialysis access procedures: Impact of preoperative noninvasive evaluation
    • Silva MB, Hobson RW III, Pappas PJ, et al. A strategy for increasing use of autogenous hemodialysis access procedures: impact of preoperative noninvasive evaluation. J Vasc Surg. 1998 ; 27: 302-308.
    • (1998) J Vasc Surg , vol.27 , pp. 302-308
    • Silva, M.B.1    Hobson III, R.W.2    Pappas, P.J.3
  • 4
    • 0030884677 scopus 로고    scopus 로고
    • NFK-DOQI clinical practice guidelines for vascular access. National Kidney Foundation-Dialysis Outcomes Quality Initiative
    • The Vascular Access Work Group.
    • The Vascular Access Work Group. NFK-DOQI clinical practice guidelines for vascular access. National Kidney Foundation-Dialysis Outcomes Quality Initiative. Am J Kidney Dis. 1997 ; 30 (suppl 3). S150 - S191.
    • (1997) Am J Kidney Dis , vol.30 , Issue.3
  • 5
    • 0141724578 scopus 로고    scopus 로고
    • Failure of arteriovenous fistula maturation: An unintended consequence of exceeding DOQI guidelines for hemodialysis access
    • Patel ST, Hughes J., Mills JL Failure of arteriovenous fistula maturation: an unintended consequence of exceeding DOQI guidelines for hemodialysis access. J Vasc Surg. 2003 ; 38: 439-445.
    • (2003) J Vasc Surg , vol.38 , pp. 439-445
    • Patel, S.T.1    Hughes, J.2    Mills, J.L.3
  • 6
    • 0036733265 scopus 로고    scopus 로고
    • Prediction of wrist arteriovenous fistula maturation with preoperative vein mapping with ultrasonography
    • Mendes RR, Farber MA, Marston WA, Dinwiddie LC, Keagy BA, Burnham SJ Prediction of wrist arteriovenous fistula maturation with preoperative vein mapping with ultrasonography. J Vasc Surg. 2002 ; 36: 460-463.
    • (2002) J Vasc Surg , vol.36 , pp. 460-463
    • Mendes, R.R.1    Ma, F.2    Marston, W.A.3    Dinwiddie, L.C.4    Keagy, B.A.5    Burnham, S.J.6
  • 7
    • 20444500945 scopus 로고    scopus 로고
    • Frequency of critical stenosis in primary arteriovenous fistulae before hemodialysis access: Should duplex ultrasound surveillance be the standard of care
    • Grogan J., Castilla M., Lozanski L., Griffin A., Loth F., Bassiouny H. Frequency of critical stenosis in primary arteriovenous fistulae before hemodialysis access: should duplex ultrasound surveillance be the standard of care ? J Vasc Surg. 2005 ; 41: 1000-1006.
    • (2005) J Vasc Surg , vol.41 , pp. 1000-1006
    • Grogan, J.1    Castilla, M.2    Lozanski, L.3    Griffin, A.4    Loth, F.5    Bassiouny, H.6
  • 9
    • 0035207240 scopus 로고    scopus 로고
    • Salvage of immature forearm fistulas for hemodialysis by interventional radiology
    • Turmel-Rodrigues L., Mouton A., Birmele B., et al. Salvage of immature forearm fistulas for hemodialysis by interventional radiology. Nephrol Dial Transplant. 2001 ; 16: 2365-2371.
    • (2001) Nephrol Dial Transplant , vol.16 , pp. 2365-2371
    • Turmel-Rodrigues, L.1    Mouton, A.2    Birmele, B.3
  • 10
    • 0035653391 scopus 로고    scopus 로고
    • Impact of reintervention for failing upper extremity arteriovenous autogenous access for hemodialysis
    • Hingorani A., Ascher E., Kallakuri S., Greenberg S., Khanimov Y. Impact of reintervention for failing upper extremity arteriovenous autogenous access for hemodialysis. J Vasc Surg. 2001 ; 34: 1004-1009.
    • (2001) J Vasc Surg , vol.34 , pp. 1004-1009
    • Hingorani, A.1    Ascher, E.2    Kallakuri, S.3    Greenberg, S.4    Khanimov, Y.5
  • 11
    • 0035516098 scopus 로고    scopus 로고
    • Impact of secondary procedures in arteriovenous fistula maturation and maintenance
    • Berman SS, Gentile AT Impact of secondary procedures in arteriovenous fistula maturation and maintenance. J Vasc Surg. 2001 ; 34: 866-871.
    • (2001) J Vasc Surg , vol.34 , pp. 866-871
    • Berman, S.S.1    Gentile, A.T.2
  • 12
    • 0026702391 scopus 로고
    • Accuracy of duplex scanning for measurement of arterial volume flow
    • Zierler BK, Kirkman TR, Kraiss LW, et al. Accuracy of duplex scanning for measurement of arterial volume flow. J Vasc Surg. 1992 ; 16: 520-526.
    • (1992) J Vasc Surg , vol.16 , pp. 520-526
    • Zierler, B.K.1    Kirkman, T.R.2    Kraiss, L.W.3
  • 13
    • 0030250476 scopus 로고    scopus 로고
    • Hemodialysis access flow measurement: Comparison of ultrasound dilution and duplex ultrasonography
    • Sands J., Glidden D., Miranda C. Hemodialysis access flow measurement: comparison of ultrasound dilution and duplex ultrasonography. ASAIO J. 1996 ; 42: M899 - M901.
    • (1996) ASAIO J. , vol.42
    • Sands, J.1    Glidden, D.2    Miranda, C.3
  • 14
    • 0030885315 scopus 로고    scopus 로고
    • Prophylactic balloon angioplasty fails to prolong the patency of PTFE arteriovenous grafts: Results of a prospective randomized study
    • Lumsden AB, MacDonald MJ, Kikeri D., Cotsonis GA, Harker LA, Martin LG Prophylactic balloon angioplasty fails to prolong the patency of PTFE arteriovenous grafts: results of a prospective randomized study. J Vasc Surg. 1997 ; 24: 382-392.
    • (1997) J Vasc Surg , vol.24 , pp. 382-392
    • Lumsden, A.B.1    MacDonald, M.J.2    Kikeri, D.3    Cotsonis, G.A.4    Harker, L.A.5    Martin, L.G.6
  • 15
    • 0034893148 scopus 로고    scopus 로고
    • Current status of surveillance of hemodialysis access grafts
    • Back MR, Bandyk DF Current status of surveillance of hemodialysis access grafts. Ann Vasc Surg. 2001 ; 15: 491-502.
    • (2001) Ann Vasc Surg , vol.15 , pp. 491-502
    • Back, M.R.1    Bandyk, D.F.2
  • 16
    • 0024429402 scopus 로고
    • Duplex ultrasound scanning in the assessment of arteriovenous fistulas created for hemodialysis access: Comparison with digital su traction angiography
    • Tordoir JHM, deBruin HG, Hoeneveld H., Eikelboom BC, Kitslaar PJ Duplex ultrasound scanning in the assessment of arteriovenous fistulas created for hemodialysis access: comparison with digital su traction angiography. J Vasc Surg. 1989 ; 10: 122-128.
    • (1989) J Vasc Surg. , vol.10 , pp. 122-128
    • Jhm, T.1    Debruin, H.G.2    Hoeneveld, H.3    Eikelboom, B.C.4    Kitslaar, P.J.5
  • 17
    • 0031982271 scopus 로고    scopus 로고
    • Hemodialysis access stenosis: Early detection with color Doppler ultrasound
    • Older RA, Gizienski TA, Wilkowski MJ, Angle JF, Cote DA Hemodialysis access stenosis: early detection with color Doppler ultrasound. Radiology. 1998 ; 207: 161-164.
    • (1998) Radiology , vol.207 , pp. 161-164
    • Older, R.A.1    Gizienski, T.A.2    Wilkowski, M.J.3    Angle, J.F.4    Cote, D.A.5
  • 19
    • 0026539960 scopus 로고
    • The effect of Doppler flow screening studies and elective revisions on dialysis access failure
    • Sands J., Young S., Miranda C. The effect of Doppler flow screening studies and elective revisions on dialysis access failure. ASAIO J. 1992 ; 38: M524 - M527.
    • (1992) ASAIO J , vol.38
    • Sands, J.1    Young, S.2    Miranda, C.3
  • 21
    • 0028886525 scopus 로고
    • Prolongation of hemodialysis access survival with elective revision
    • Sands JJ, Miranda CL Prolongation of hemodialysis access survival with elective revision. Clin Nephrol. 1995 ; 44: 329-333.
    • (1995) Clin Nephrol , vol.44 , pp. 329-333
    • Sands, J.J.1    Miranda, C.L.2
  • 23
    • 0035127201 scopus 로고    scopus 로고
    • Cephalic vein and hemodialysis fistula: Surgeon's observation versus color Doppler ultrasonographic findings
    • Mihmanli I., Besirli K., Kurugoglu S. Cephalic vein and hemodialysis fistula: surgeon's observation versus color Doppler ultrasonographic findings. J Ultrasound Med. 2001 ; 20: 217-222.
    • (2001) J Ultrasound Med , vol.20 , pp. 217-222
    • Mihmanli, I.1    Besirli, K.2    Kurugoglu, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.