메뉴 건너뛰기




Volumn 81, Issue 3, 2011, Pages

Stability of markers used for real-time tumor tracking after percutaneous intrapulmonary placement

Author keywords

Lung cancer; Markers; Percutaneous intrapulmonary placement; Real time tumor tracking; Stereotactic radiotherapy

Indexed keywords

LUNG CANCER; MARKERS; PERCUTANEOUS INTRAPULMONARY PLACEMENT; REAL-TIME TUMOR TRACKING; STEREOTACTIC RADIOTHERAPY;

EID: 80053582777     PISSN: 03603016     EISSN: 1879355X     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2010.12.026     Document Type: Article
Times cited : (28)

References (17)
  • 5
    • 65649110515 scopus 로고    scopus 로고
    • Stereotactic radiotherapy with real-time tumor tracking for non-small cell lung cancer: Clinical outcome
    • N.C. van der Voort van Zyp, J.B. Prevost, and M.S. Hoogeman Stereotactic radiotherapy with real-time tumor tracking for non-small cell lung cancer: Clinical outcome Radiother Oncol 91 2009 296 300
    • (2009) Radiother Oncol , vol.91 , pp. 296-300
    • Van Der Voort Van Zyp, N.C.1    Prevost, J.B.2    Hoogeman, M.S.3
  • 8
    • 64049103804 scopus 로고    scopus 로고
    • Clinical accuracy of the respiratory tumor tracking system of the cyberknife: Assessment by analysis of log files
    • M. Hoogeman, J.B. Prevost, and J. Nuyttens Clinical accuracy of the respiratory tumor tracking system of the cyberknife: Assessment by analysis of log files Int J Radiat Oncol Biol Phys 74 2009 297 303
    • (2009) Int J Radiat Oncol Biol Phys , vol.74 , pp. 297-303
    • Hoogeman, M.1    Prevost, J.B.2    Nuyttens, J.3
  • 11
    • 69549116737 scopus 로고    scopus 로고
    • Measurement of interfraction variations in position and size of target volumes in stereotactic body radiotherapy for lung cancer
    • K. Matsugi, Y. Narita, and A. Sawada Measurement of interfraction variations in position and size of target volumes in stereotactic body radiotherapy for lung cancer Int J Radiat Oncol Biol Phys 75 2009 543 548
    • (2009) Int J Radiat Oncol Biol Phys , vol.75 , pp. 543-548
    • Matsugi, K.1    Narita, Y.2    Sawada, A.3
  • 12
    • 33644517882 scopus 로고    scopus 로고
    • Time trends in target volumes for stage i non-small-cell lung cancer after stereotactic radiotherapy
    • R.W. Underberg, F.J. Lagerwaard, and H. van Tinteren Time trends in target volumes for stage I non-small-cell lung cancer after stereotactic radiotherapy Int J Radiat Oncol Biol Phys 64 2006 1221 1228
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , pp. 1221-1228
    • Underberg, R.W.1    Lagerwaard, F.J.2    Van Tinteren, H.3
  • 13
    • 70350733234 scopus 로고    scopus 로고
    • Point/counterpoint: Only a single implanted marker is needed for tracking lung cancers for IGRT
    • X. Wu, S. Dieterich, and C.G. Orton Point/counterpoint: Only a single implanted marker is needed for tracking lung cancers for IGRT Med Phys 36 2009 4845 4847
    • (2009) Med Phys , vol.36 , pp. 4845-4847
    • Wu, X.1    Dieterich, S.2    Orton, C.G.3
  • 14
    • 48949116232 scopus 로고    scopus 로고
    • Endovascular coils as lung tumour markers in real-time tumour tracking stereotactic radiotherapy: Preliminary results
    • J.B. Prevost, J.J. Nuyttens, and M.S. Hoogeman Endovascular coils as lung tumour markers in real-time tumour tracking stereotactic radiotherapy: Preliminary results Eur Radiol 18 2008 1569 1576
    • (2008) Eur Radiol , vol.18 , pp. 1569-1576
    • Prevost, J.B.1    Nuyttens, J.J.2    Hoogeman, M.S.3
  • 15
    • 35448929858 scopus 로고    scopus 로고
    • Electromagnetic navigation bronchoscopy-guided fiducial placement for robotic stereotactic radiosurgery of lung tumors: A feasibility study
    • D. Anantham, D. Feller-Kopman, and L.N. Shanmugham Electromagnetic navigation bronchoscopy-guided fiducial placement for robotic stereotactic radiosurgery of lung tumors: A feasibility study Chest 132 2007 930 935
    • (2007) Chest , vol.132 , pp. 930-935
    • Anantham, D.1    Feller-Kopman, D.2    Shanmugham, L.N.3
  • 16
    • 33747200502 scopus 로고    scopus 로고
    • EUS-guided fiducial placement for CyberKnife radiotherapy of mediastinal and abdominal malignancies
    • DOI 10.1016/j.gie.2006.01.048, PII S0016510706002100
    • A.C. Pishvaian, B. Collins, and G. Gagnon EUS-guided fiducial placement for CyberKnife radiotherapy of mediastinal and abdominal malignancies Gastrointest Endosc 64 2006 412 417 (Pubitemid 44233565)
    • (2006) Gastrointestinal Endoscopy , vol.64 , Issue.3 , pp. 412-417
    • Pishvaian, A.C.1    Collins, B.2    Gagnon, G.3    Ahlawat, S.4    Haddad, N.G.5
  • 17
    • 33644874333 scopus 로고    scopus 로고
    • Endovascular coiling versus neurosurgical clipping for patients with aneurysmal subarachnoid haemorrhage
    • CD003085
    • I. van der Schaaf, A. Algra, and M. Wermer Endovascular coiling versus neurosurgical clipping for patients with aneurysmal subarachnoid haemorrhage Cochrane Database Syst Rev 2005 CD003085
    • (2005) Cochrane Database Syst Rev
    • Van Der Schaaf, I.1    Algra, A.2    Wermer, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.