메뉴 건너뛰기




Volumn 63, Issue 4, 2005, Pages 1024-1028

Serial megavoltage CT imaging during external beam radiotherapy for non-small-cell lung cancer: Observations on tumor regression during treatment

Author keywords

Megavoltage CT; Non small cell lung cancer; Tumor regression

Indexed keywords

ATTENUATION; COMPUTERIZED TOMOGRAPHY; MEDICAL IMAGING; PATIENT MONITORING; REGRESSION ANALYSIS; TISSUE; TUMORS;

EID: 27144468304     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2005.04.046     Document Type: Article
Times cited : (170)

References (13)
  • 1
    • 0035879542 scopus 로고    scopus 로고
    • Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration
    • E.A. Barnes, B.R. Murray, D.M. Robinson Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration Int J Radiat Oncol Biol Phys 50 2001 1091 1098
    • (2001) Int J Radiat Oncol Biol Phys , vol.50 , pp. 1091-1098
    • Barnes, E.A.1    Murray, B.R.2    Robinson, D.M.3
  • 2
    • 0036918331 scopus 로고    scopus 로고
    • Cone-beam CT with megavoltage beams and an amorphous silicon electronic portal imaging device: Potential for verification of radiotherapy of lung cancer
    • E.C. Ford, J. Chang, K. Mueller Cone-beam CT with megavoltage beams and an amorphous silicon electronic portal imaging device Potential for verification of radiotherapy of lung cancer Med Phys 29 2002 2913 2924
    • (2002) Med Phys , vol.29 , pp. 2913-2924
    • Ford, E.C.1    Chang, J.2    Mueller, K.3
  • 3
    • 0842306297 scopus 로고    scopus 로고
    • Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment
    • G.S. Mageras, E. Yorke Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment Semin Radiat Oncol 14 2004 65 75
    • (2004) Semin Radiat Oncol , vol.14 , pp. 65-75
    • Mageras, G.S.1    Yorke, E.2
  • 5
    • 0034333029 scopus 로고    scopus 로고
    • Physical aspects of a real-time tumor-tracking system for gated radiotherapy
    • H. Shirato, S. Shimizu, T. Kunieda Physical aspects of a real-time tumor-tracking system for gated radiotherapy Int J Radiat Oncol Biol Phys 48 2000 1187 1195
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 1187-1195
    • Shirato, H.1    Shimizu, S.2    Kunieda, T.3
  • 6
    • 0037402937 scopus 로고    scopus 로고
    • Three-dimensional treatment planning using electrocardiographically gated multi-detector row CT
    • K. Yamada, T. Soejima, T. Minami Three-dimensional treatment planning using electrocardiographically gated multi-detector row CT Int J Radiat Oncol Biol Phys 56 2003 235 239
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 235-239
    • Yamada, K.1    Soejima, T.2    Minami, T.3
  • 8
    • 4444313414 scopus 로고    scopus 로고
    • Planning evaluation of radiotherapy for complex lung cancer cases using helical tomotherapy
    • T. Kron, G. Grigorov, E. Yu Planning evaluation of radiotherapy for complex lung cancer cases using helical tomotherapy Phys Med Biol 49 2004 3675 3690
    • (2004) Phys Med Biol , vol.49 , pp. 3675-3690
    • Kron, T.1    Grigorov, G.2    Yu, E.3
  • 9
    • 0035169875 scopus 로고    scopus 로고
    • A new approach to dose escalation in non-small-cell lung cancer
    • M. Mehta, R. Scrimger, R. Mackie A new approach to dose escalation in non-small-cell lung cancer Int J Radiat Oncol Biol Phys 49 2001 23 33
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 23-33
    • Mehta, M.1    Scrimger, R.2    MacKie, R.3
  • 10
    • 0037318974 scopus 로고    scopus 로고
    • Reduction in radiation dose to lung and other normal tissues using helical tomotherapy to treat lung cancer, in comparison to conventional field arrangements
    • R.A. Scrimger, W.A. Tome, G.H. Olivera Reduction in radiation dose to lung and other normal tissues using helical tomotherapy to treat lung cancer, in comparison to conventional field arrangements Am J Clin Oncol 26 2003 70 78
    • (2003) Am J Clin Oncol , vol.26 , pp. 70-78
    • Scrimger, R.A.1    Tome, W.A.2    Olivera, G.H.3
  • 11
    • 2442480847 scopus 로고    scopus 로고
    • Megavoltage computed tomography imaging: A potential tool to guide and improve the delivery of thoracic radiation therapy
    • J.S. Welsh, K. Bradley, K.J. Ruchala Megavoltage computed tomography imaging A potential tool to guide and improve the delivery of thoracic radiation therapy Clin Lung Cancer 5 2004 303 306
    • (2004) Clin Lung Cancer , vol.5 , pp. 303-306
    • Welsh, J.S.1    Bradley, K.2    Ruchala, K.J.3
  • 12
    • 0037249948 scopus 로고    scopus 로고
    • Portal imaging to assess set-up errors, tumor motion, and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer
    • S.C. Erridge, Y. Seppenwoolde, S.H. Muller Portal imaging to assess set-up errors, tumor motion, and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer Radiother Oncol 66 2003 75 85
    • (2003) Radiother Oncol , vol.66 , pp. 75-85
    • Erridge, S.C.1    Seppenwoolde, Y.2    Muller, S.H.3
  • 13
    • 0030271699 scopus 로고    scopus 로고
    • Prognostic factors in the treatment of node-negative nonsmall cell lung carcinoma with radiotherapy alone
    • P.A. Kupelian, R. Komaki, P. Allen Prognostic factors in the treatment of node-negative nonsmall cell lung carcinoma with radiotherapy alone Int J Radiat Oncol Biol Phys 36 1996 607 613
    • (1996) Int J Radiat Oncol Biol Phys , vol.36 , pp. 607-613
    • Kupelian, P.A.1    Komaki, R.2    Allen, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.