메뉴 건너뛰기




Volumn 6, Issue 6, 2011, Pages

Analysis and correction of the magnetic field effects in the Hybrid Photo-Detectors of the RICH2 Ring Imaging Cherenkov detector of LHCb.

Author keywords

Cherenkov detectors; Large detector systems for particle and astroparticle physics; Photon detectors for UV, visible and IR photons (vacuum)

Indexed keywords


EID: 80053559817     PISSN: None     EISSN: 17480221     Source Type: Journal    
DOI: 10.1088/1748-0221/6/06/P06010     Document Type: Article
Times cited : (5)

References (20)
  • 1
    • 67650308285 scopus 로고    scopus 로고
    • The LHCb detector at the LHC
    • LHCb collaboration
    • LHCb collaboration 2008 The LHCb detector at the LHC, JINST 3 S08005
    • (2008) JINST , vol.3 , pp. 08005
  • 4
    • 51649097826 scopus 로고    scopus 로고
    • Commissioning of the LHCb RICH detectors
    • LHCb RICH collaboration
    • LHCb RICH collaboration, C. D'Ambrosio 2008 Commissioning of the LHCb RICH detectors, Nucl. Instrum. Meth. A 595 36
    • (2008) Nucl. Instrum. Meth. A , vol.595 , pp. 36
    • D'Ambrosio, C.1
  • 5
    • 0035366533 scopus 로고    scopus 로고
    • The pixel hybrid photon detectors for the LHCb-RICH project
    • T. Gys 2000 The pixel hybrid photon detectors for the LHCb-RICH project, Nucl. Instrum. Meth. A 465 240
    • (2000) Nucl. Instrum. Meth. A , vol.465 , pp. 240
    • Gys, T.1
  • 7
    • 3343016792 scopus 로고    scopus 로고
    • Performance study of new pixel hybrid photon detector prototypes for the LHCb RICH counters
    • M. Moritz et al. 2004 Performance study of new pixel hybrid photon detector prototypes for the LHCb RICH counters, IEEE Trans. Nucl. Sci. 51 1060
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , pp. 1060
    • Moritz, M.1
  • 8
    • 51649128494 scopus 로고    scopus 로고
    • Production and tests of hybrid photon detectors for the LHCb RICH detectors
    • S. Eisenhardt 2008 Production and tests of hybrid photon detectors for the LHCb RICH detectors, Nucl. Instrum. Meth. A 595 142 and references therein
    • (2008) Nucl. Instrum. Meth. A , vol.595 , pp. 142
    • Eisenhardt, S.1
  • 10
    • 79955699840 scopus 로고    scopus 로고
    • Magnetic distortion calibration for LHCb RICH detectors
    • F. Xing 2011 Magnetic distortion calibration for LHCb RICH detectors, Nucl. Instrum. Meth. A 639 242
    • (2011) Nucl. Instrum. Meth. A , vol.639 , pp. 242
    • Xing, F.1
  • 14
    • 27644497528 scopus 로고    scopus 로고
    • Characterisation and compensation of magnetic distortions for the pixel hybrid photon detectors of the LHCb RICH
    • G. Aglieri Rinella et al. 2005 Characterisation and compensation of magnetic distortions for the pixel hybrid photon detectors of the LHCb RICH, Nucl. Instrum. Meth. A 553 120
    • (2005) Nucl. Instrum. Meth. A , vol.553 , pp. 120
    • Aglieri Rinella, G.1
  • 15
    • 84876669028 scopus 로고    scopus 로고
    • Technical documentation on the Samsung SP-P310ME can be found at the Samsumg website
    • Technical documentation on the Samsung SP-P310ME can be found at the Samsumg website, http://www.samsung.com/us/support/supportDownloadCenter.do?prd- ia-cd=N0000156&prd-mdl-cd=SPP310MEMX%2FXAA&prd-mdl-name=SP-P310ME - ref-separator -
  • 20
    • 79958288772 scopus 로고    scopus 로고
    • Hybrid photon detectors and ion feedback
    • LHCb RICH collaboration, S. Eisenhardt 2010 Hybrid photon detectors and ion feedback, Nucl. Instrum. Meth. A 617 391
    • (2010) Nucl. Instrum. Meth. A , vol.617 , pp. 391
    • Eisenhardt, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.