메뉴 건너뛰기




Volumn 6892 LNCS, Issue PART 2, 2011, Pages 174-181

Susceptibility distortion correction for echo planar images with non-uniform B-spline grid sampling: A diffusion tensor image study

Author keywords

[No Author keywords available]

Indexed keywords

B SPLINES; B-SPLINE; CONTROL POINT; CORRECTION SCHEMES; DEFORMABLE REGISTRATION; DIFFUSION TENSOR IMAGES; DIFFUSION WEIGHTED IMAGES; DISTORTION CORRECTION; ECHO PLANAR IMAGING; FIBER TRACTS; GEOMETRIC DISTORTION; INITIAL SEGMENTATION; LOCAL OPTIMA; PHASE ENCODING; PLANAR IMAGES; SPATIAL DISTORTION;

EID: 80053532801     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-642-23629-7_22     Document Type: Conference Paper
Times cited : (19)

References (10)
  • 1
    • 36149042452 scopus 로고
    • Multi-planar image formation using NMR spin echoes
    • Mansfield, P.: Multi-planar image formation using NMR spin echoes. J. Phys. C. 10, 55 (1977)
    • (1977) J. Phys. C. , vol.10 , pp. 55
    • Mansfield, P.1
  • 2
    • 0029034190 scopus 로고
    • Correction for geometric distortion in echo planar images from b0 field variations
    • Jezzard, P., Balban, R.: Correction for geometric distortion in echo planar images from b0 field variations. Magnetic Resonance in Medicine 34, 65-73 (1995)
    • (1995) Magnetic Resonance in Medicine , vol.34 , pp. 65-73
    • Jezzard, P.1    Balban, R.2
  • 3
    • 0031910857 scopus 로고    scopus 로고
    • Correction of off resonance related distortion in echo-planar imaging using epi-based field maps
    • Reber, P.J., Wong, E., Buxton, R., Frank, L.R.: Correction of off resonance related distortion in echo-planar imaging using epi-based field maps. Magn. Res. in Med. 39, 328-330 (1998)
    • (1998) Magn. Res. in Med. , vol.39 , pp. 328-330
    • Reber, P.J.1    Wong, E.2    Buxton, R.3    Frank, L.R.4
  • 5
    • 27644550523 scopus 로고    scopus 로고
    • Geometric distortion correction of high-resolution 3T diffusion tensor brain images
    • Ardekani, S., Sinha, U.: Geometric distortion correction of high-resolution 3T diffusion tensor brain images. Magn. Res. in Med. 54, 1163-1171 (2005)
    • (2005) Magn. Res. in Med. , vol.54 , pp. 1163-1171
    • Ardekani, S.1    Sinha, U.2
  • 6
    • 79551688044 scopus 로고    scopus 로고
    • Comparison of EPI distortion correction methods in diffusion tensor MRI using a novel framework
    • Metaxas, D., Axel, L., Fichtinger, G., Székely, G. (eds.) MICCAI 2008, Springer, Heidelberg
    • Wu, M., Chang, L.C., Walker, L., Lemaitre, H., Barnett, A.S., Marenco, S., Pierpaoli, C.: Comparison of EPI distortion correction methods in diffusion tensor MRI using a novel framework. In: Metaxas, D., Axel, L., Fichtinger, G., Székely, G. (eds.) MICCAI 2008, Part II. LNCS, vol. 5242, pp. 321-329. Springer, Heidelberg (2008)
    • (2008) LNCS , vol.5242 , Issue.PART II , pp. 321-329
    • Wu, M.1    Chang, L.C.2    Walker, L.3    Lemaitre, H.4    Barnett, A.S.5    Marenco, S.6    Pierpaoli, C.7
  • 7
    • 70349315246 scopus 로고    scopus 로고
    • A variational image-based approach to the correction of susceptibility artifacts in the alignment of diffusion weighted and structural MRI
    • Tao, R., Fletcher, P.T., Gerber, S., Whitaker, R.T.: A variational image-based approach to the correction of susceptibility artifacts in the alignment of diffusion weighted and structural MRI. Inf. Process Med. Imaging 21, 664-675 (2009)
    • (2009) Inf. Process Med. Imaging , vol.21 , pp. 664-675
    • Tao, R.1    Fletcher, P.T.2    Gerber, S.3    Whitaker, R.T.4
  • 8
  • 9
    • 4243079824 scopus 로고    scopus 로고
    • Perturbation method for magnetic field calculations of nonconductive objects
    • Jenkinson, M., Wilson, J.L., Jezzard, P.: Perturbation method for magnetic field calculations of nonconductive objects. Magn. Res. in Med. 52, 471-477 (2004)
    • (2004) Magn. Res. in Med. , vol.52 , pp. 471-477
    • Jenkinson, M.1    Wilson, J.L.2    Jezzard, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.