메뉴 건너뛰기




Volumn , Issue , 2011, Pages

A new fault detection method for NPC converters

Author keywords

Diagnostics; Fault handling strategy; Fault tolerance; Industrial application; Multilevel converters

Indexed keywords

DETECTION METHODS; FAULT HANDLING STRATEGY; FEEDBACK SIGNAL; HIGH-POWER; MEDIUM VOLTAGE; MULTILEVEL CONVERTER; NEUTRAL POINT CLAMPED CONVERTERS; POWER SEMICONDUCTOR DEVICES; RELIABILITY AND AVAILABILITY;

EID: 80053524581     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (28)

References (23)
  • 1
    • 0019609910 scopus 로고
    • A neutral-point clamped PWM inverter
    • A. Nabae, I. Takahashi, H. Akagi: A neutral-point clamped PWM inverter, IEEE Trans. on I.A., Vol. 17 no 5, pp. 518- 523, 1981
    • (1981) IEEE Trans. on I.A. , vol.17 , Issue.5 , pp. 518-523
    • Nabae, A.1    Takahashi, I.2    Akagi, H.3
  • 2
    • 0030149153 scopus 로고    scopus 로고
    • Multilevel converters - A new breed of power converters
    • May/June
    • J.S. Lai, F.Z. Peng: Multilevel converters - A new breed of power converters, IEEE Trans. on I.A., Vol. 32 no 3, pp. 509-517, May/June 1996
    • (1996) IEEE Trans. on I.A. , vol.32 , Issue.3 , pp. 509-517
    • Lai, J.S.1    Peng, F.Z.2
  • 7
    • 0036687556 scopus 로고    scopus 로고
    • Diode-Clamped Multilevel converters: A practicable way to balance dc-link voltages
    • August
    • M. Marchesoni, P. Tenca: Diode-Clamped Multilevel converters: a practicable way to balance dc-link voltages, IEEE Trans. on Industrial Electronics, Vol. 49, No. 4, August, 2002, pp. 752-765.
    • (2002) IEEE Trans. on Industrial Electronics , vol.49 , Issue.4 , pp. 752-765
    • Marchesoni, M.1    Tenca, P.2
  • 11
    • 17444395148 scopus 로고    scopus 로고
    • A multilevel converter topology with fault-tolerant ability
    • DOI 10.1109/TPEL.2004.842983
    • A.L. Chen, L. Hu, L.F. Chen, Y. Deng, X.N. He: A multilevel converter topology with fault tolerant ability, IEEE Transactions on Power Electronics, vol. 20, no.2, pp.405-415, March 2005. (Pubitemid 40535743)
    • (2005) IEEE Transactions on Power Electronics , vol.20 , Issue.2 , pp. 405-415
    • Chen, A.1    Hu, L.2    Chen, L.3    Deng, Y.4    He, X.5
  • 12
    • 0037233333 scopus 로고    scopus 로고
    • Control method for cascaded H-bridge multilevel inverter with faulty power cells
    • Feb
    • S.M. Wei, B. Wu, F.H. Li, X.D. Sun: Control method for cascaded H-bridge multilevel inverter with faulty power cells, Proc.IEEE Appl. Power Electronic Conf., Miami, vol.1, pp.261-267, Feb 2003.
    • (2003) Proc.IEEE Appl. Power Electronic Conf., Miami , vol.1 , pp. 261-267
    • Wei, S.M.1    Wu, B.2    Li, F.H.3    Sun, X.D.4
  • 17
    • 77954615301 scopus 로고    scopus 로고
    • Performance evaluation of fault-tolerant Neutral-Point-Clamped converters
    • Aug
    • S. Ceballos, J. Pou, E. Robles, J. Zaragoza, J. L. Martin: Performance evaluation of fault-tolerant Neutral-Point-Clamped converters, IEEE Trans. on I.E., Vol. 57, No. 8, Aug 2010, pp. 2709-2718.
    • (2010) IEEE Trans. on I.E. , vol.57 , Issue.8 , pp. 2709-2718
    • Ceballos, S.1    Pou, J.2    Robles, E.3    Zaragoza, J.4    Martin, J.L.5
  • 19
    • 33747585846 scopus 로고    scopus 로고
    • On the operation of a press pack IGBT module under short circuit conditions
    • DOI 10.1109/TADVP.2006.875090
    • S. Gunturi, D. Schneider: On the operation of a press pack IGBT module under short circuit conditions, IEEE Transactions on Advanced Packaging, Vol 29 Issue 3, pp 433-440, 2006. (Pubitemid 44263684)
    • (2006) IEEE Transactions on Advanced Packaging , vol.29 , Issue.3 , pp. 433-440
    • Gunturi, S.1    Schneider, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.