메뉴 건너뛰기




Volumn 136, Issue 4, 2011, Pages 609-616

Current and future applications of mass spectrometry to the clinical laboratory

Author keywords

Atmospheric pressure chemical ionization; Electrospray ionization; Liquid chromatography tandem mass spectrometry; Mass spectrometry; Multiple reaction monitoring; Selected ion monitoring

Indexed keywords

ANALYZER; CLINICAL LABORATORY; ELECTROSPRAY; GAS CHROMATOGRAPHY; LIQUID CHROMATOGRAPHY; MASS SPECTROMETRY; METABOLOMICS; PRIORITY JOURNAL; QUADRUPOLE MASS SPECTROMETRY; REVIEW; SOLID PHASE EXTRACTION; TANDEM MASS SPECTROMETRY; TIME OF FLIGHT MASS SPECTROMETRY;

EID: 80053492663     PISSN: 00029173     EISSN: 19437722     Source Type: Journal    
DOI: 10.1309/AJCPW0TA8OBBNGCK     Document Type: Review
Times cited : (78)

References (23)
  • 6
    • 0038574979 scopus 로고    scopus 로고
    • Ion suppression in mass spectrometry
    • DOI 10.1373/49.7.1041
    • Annesley TM. Ion suppression in mass spectrometry. Clin Chem. 2003;49:1041-1044. (Pubitemid 36751088)
    • (2003) Clinical Chemistry , vol.49 , Issue.7 , pp. 1041-1044
    • Annesley, T.M.1
  • 7
    • 0035241692 scopus 로고    scopus 로고
    • Mass spectrometry in the clinical laboratory
    • DOI 10.1021/cr990077+
    • Chace DH. Mass spectrometry in the clinical laboratory. Chem Rev. 2001;101:445-477. (Pubitemid 32325801)
    • (2001) Chemical Reviews , vol.101 , Issue.2 , pp. 445-477
    • Chace, D.H.1
  • 8
    • 67650432879 scopus 로고    scopus 로고
    • The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry
    • Hoofnagle AN, Wener MH. The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry. J Immunol Methods. 2009;347:3-11.
    • (2009) J Immunol Methods , vol.347 , pp. 3-11
    • Hoofnagle, A.N.1    Wener, M.H.2
  • 9
    • 77955417271 scopus 로고    scopus 로고
    • Quantification of circulating 25-hydroxyvitamin D by liquid chromatography-tandem mass spectrometry
    • Vogeser M. Quantification of circulating 25-hydroxyvitamin D by liquid chromatography-tandem mass spectrometry. J Steroid Biochem Mol Biol. 2010;121:565-573.
    • (2010) J Steroid Biochem Mol Biol , vol.121 , pp. 565-573
    • Vogeser, M.1
  • 10
    • 33744494040 scopus 로고    scopus 로고
    • 3 using HPLC-tandem mass spectrometry and examination of reference intervals for diagnosis of vitamin D deficiency
    • 3 using HPLC-tandem mass spectrometry and examination of reference intervals for diagnosis of vitamin D deficiency. Am J Clin Pathol. 2006;125:914-920.
    • (2006) Am J Clin Pathol , vol.125 , pp. 914-920
    • Saenger, A.K.1    Laha, T.J.2    Bremner, D.E.3
  • 11
    • 77952102785 scopus 로고    scopus 로고
    • A rubber transfer gasket to improve the throughput of liquid-liquid extraction in 96-well plates: Application to vitamin D testing
    • Hoofnagle AN, Laha TJ, Donaldson TF. A rubber transfer gasket to improve the throughput of liquid-liquid extraction in 96-well plates: application to vitamin D testing. J Chromatogr B Analyt Technol Biomed Life Sci. 2010;878:1639-1642.
    • (2010) J Chromatogr B Analyt Technol Biomed Life Sci , vol.878 , pp. 1639-1642
    • Hoofnagle, A.N.1    Laha, T.J.2    Donaldson, T.F.3
  • 12
    • 33747637729 scopus 로고    scopus 로고
    • C-3 epimers can account for a significant proportion of total circulating 25-hydroxyvitamin D in infants, complicating accurate measurement and interpretation of vitamin D status
    • DOI 10.1210/jc.2006-0710
    • Singh RJ, Taylor RL, Reddy GS, et al. C-3 epimers can account for a significant proportion of total circulating 25-hydroxyvitamin D in infants, complicating accurate measurement and interpretation of vitamin D status. J Clin Endocrinol Metab. 2006;91:3055-3061. (Pubitemid 44271755)
    • (2006) Journal of Clinical Endocrinology and Metabolism , vol.91 , Issue.8 , pp. 3055-3061
    • Singh, R.J.1    Taylor, R.L.2    Reddy, G.S.3    Grebe, S.K.G.4
  • 13
    • 77952801705 scopus 로고    scopus 로고
    • Liquid chromatography-tandem mass spectrometry applications in endocrinology
    • Kushnir MM, Rockwood AL, Bergquist J. Liquid chromatography-tandem mass spectrometry applications in endocrinology. Mass Spectrom Rev. 2010;29:480-502.
    • (2010) Mass Spectrom Rev , vol.29 , pp. 480-502
    • Kushnir, M.M.1    Rockwood, A.L.2    Bergquist, J.3
  • 14
    • 35948932643 scopus 로고    scopus 로고
    • Liquid chromatography tandem-mass spectrometry (LC-MS/MS) - Technique and applications in endocrinology
    • DOI 10.1055/s-2007-981458
    • Vogeser M, Parhofer KG. Liquid chromatography tandem-mass spectrometry (LC-MS/MS): technique and applications in endocrinology. Exp Clin Endocrinol Diabetes. 2007;115:559-570. (Pubitemid 350070925)
    • (2007) Experimental and Clinical Endocrinology and Diabetes , vol.115 , Issue.9 , pp. 559-570
    • Vogeser, M.1    Parhofer, K.G.2
  • 15
    • 67651095793 scopus 로고    scopus 로고
    • Cross reactions elicited by serum 17-OH progesterone and 11-desoxycortisol in cortisol assays
    • Brossaud J, Barat P, Gualde D, et al. Cross reactions elicited by serum 17-OH progesterone and 11-desoxycortisol in cortisol assays. Clin Chim Acta. 2009;407:72-74.
    • (2009) Clin Chim Acta , vol.407 , pp. 72-74
    • Brossaud, J.1    Barat, P.2    Gualde, D.3
  • 16
    • 80053548290 scopus 로고    scopus 로고
    • Interferences in an LC-MS/MS steroid assay: Systematic reduction of possible endogenous interferences from database searches and examination of an exogenous interference from sample collection
    • [abstract]. Presented at
    • Cournoyer J, Nair H, Seward R, et al. Interferences in an LC-MS/MS steroid assay: systematic reduction of possible endogenous interferences from database searches and examination of an exogenous interference from sample collection [abstract]. Presented at: Mass Spectrometry Applications to the Clinical Laboratory Annual Meeting; February 5-9, 2011; San Diego, CA.
    • Mass Spectrometry Applications to the Clinical Laboratory Annual Meeting; February 5-9, 2011; San Diego, CA
    • Cournoyer, J.1    Nair, H.2    Seward, R.3
  • 18
    • 75749100667 scopus 로고    scopus 로고
    • Quantitative clinical proteomics by liquid chromatography-tandem mass spectrometry: Assessing the platform
    • Hoofnagle AN. Quantitative clinical proteomics by liquid chromatography-tandem mass spectrometry: assessing the platform. Clin Chem. 2010;56:161-164.
    • (2010) Clin Chem , vol.56 , pp. 161-164
    • Hoofnagle, A.N.1
  • 20
    • 79953746862 scopus 로고    scopus 로고
    • Amino acid profiling for the diagnosis of inborn errors of metabolism
    • Piraud M, Ruet S, Boyer S, et al. Amino acid profiling for the diagnosis of inborn errors of metabolism. Methods Mol Biol. 2011;708:25-53.
    • (2011) Methods Mol Biol , vol.708 , pp. 25-53
    • Piraud, M.1    Ruet, S.2    Boyer, S.3
  • 21
    • 77957593707 scopus 로고    scopus 로고
    • Newborn screening for disorders of fatty-acid oxidation: Experience and recommendations from an expert meeting
    • Lindner M, Hoffmann GF, Matern D. Newborn screening for disorders of fatty-acid oxidation: experience and recommendations from an expert meeting. J Inherit Metab Dis. 2010;33:521-526.
    • (2010) J Inherit Metab Dis , vol.33 , pp. 521-526
    • Lindner, M.1    Hoffmann, G.F.2    Matern, D.3
  • 22
    • 77954370184 scopus 로고    scopus 로고
    • Newborn screening of lysosomal storage disorders
    • Marsden D, Levy H. Newborn screening of lysosomal storage disorders. Clin Chem. 2010;56:1071-1079.
    • (2010) Clin Chem , vol.56 , pp. 1071-1079
    • Marsden, D.1    Levy, H.2
  • 23
    • 79952529218 scopus 로고    scopus 로고
    • A powerful couple in the future of clinical biochemistry: In situ analysis of dried blood spots by ambient mass spectrometry
    • Corso G, D'Apolito O, Gelzo M, et al. A powerful couple in the future of clinical biochemistry: in situ analysis of dried blood spots by ambient mass spectrometry. Bioanalysis. 2010;2:1883-1891.
    • (2010) Bioanalysis , vol.2 , pp. 1883-1891
    • Corso, G.1    D'Apolito, O.2    Gelzo, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.