메뉴 건너뛰기




Volumn 45, Issue 19, 2011, Pages 8536-8542

Online monitoring of water toxicity by use of bioluminescent reporter bacterial biochips

Author keywords

[No Author keywords available]

Indexed keywords

EARLY WARNING SYSTEM; FLOWTHROUGH; INDUSTRIAL WASTEWATERS; MODEL COMPOUND; ONLINE MONITORING; SECURITY NETWORKS; SINGLE PHOTON AVALANCHE DIODE; TOXIC CHEMICALS; TOXICITY MONITORING; WATER FLOWS; WATER POLLUTANTS; WATER SAFETY;

EID: 80053430106     PISSN: 0013936X     EISSN: 15205851     Source Type: Journal    
DOI: 10.1021/es202465c     Document Type: Article
Times cited : (71)

References (40)
  • 1
    • 0031974551 scopus 로고    scopus 로고
    • New online biomonitoring system for Gammarus pulex (L) (Crustacea): In situ test below a copper effluent in South Sweden
    • DOI 10.1021/es970442j
    • Gerhardt, A.; Carlsson, A.; Ressemann, C.; Stich, K. P. New online biomonitoring system for Gammarus pulex (L.) (Crustacea): in situ test below a copper effluent in south Sweden Environ. Sci. Technol. 1998, 32, 150-156 (Pubitemid 28035914)
    • (1998) Environmental Science and Technology , vol.32 , Issue.1 , pp. 150-156
    • Gerhardt, A.1    Carlsson, A.2    Ressemann, C.3    Stich, K.P.4
  • 3
    • 33750583638 scopus 로고    scopus 로고
    • In situ on-line toxicity biomonitoring in water: Recent developments
    • DOI 10.1897/05-486R1.1
    • Gerhardt, A.; Ingram, M. K.; Kang, I. J.; Ulitzur, S. In situ on-line toxicity biomonitoring in water: recent developments Environ. Toxicol. Chem. 2006, 25, 2263-2271 (Pubitemid 44763281)
    • (2006) Environmental Toxicology and Chemistry , vol.25 , Issue.9 , pp. 2263-2271
    • Gerhardt, A.1    Ingram, M.K.2    Kang, I.J.3    Ulitzur, S.4
  • 4
    • 0038604176 scopus 로고    scopus 로고
    • Microbial whole-cell sensing systems of environmental pollutants
    • DOI 10.1016/S1369-5274(03)00059-6
    • Belkin, S. Microbial whole-cell sensing systems of environmental pollutants Curr. Opin. Microbiol. 2003, 6, 206-212 (Pubitemid 36841662)
    • (2003) Current Opinion in Microbiology , vol.6 , Issue.3 , pp. 206-212
    • Belkin, S.1
  • 5
    • 77953622209 scopus 로고    scopus 로고
    • Where microbiology meets microengineering: Design and applications of reporter bacteria
    • van der Meer, J. R.; Belkin, S. Where microbiology meets microengineering: design and applications of reporter bacteria Nat. Rev. Microbiol. 2010, 8, 511-522
    • (2010) Nat. Rev. Microbiol. , vol.8 , pp. 511-522
    • Van Der Meer, J.R.1    Belkin, S.2
  • 7
    • 33847377484 scopus 로고    scopus 로고
    • An oxidative stress-specific bacterial cell array chip for toxicity analysis
    • DOI 10.1016/j.bios.2006.10.038, PII S0956566306005306, Selected Papers from the Ninth World Congress On Biosensors
    • Lee, J. H.; Youn, C. H.; Kim, B. C.; Gu, M. B. An oxidative stress-specific bacterial cell array chip for toxicity analysis Biosens. Bioelectron. 2007, 22, 2223-2229 (Pubitemid 46349672)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.9-10 , pp. 2223-2229
    • Lee, J.H.1    Youn, C.H.2    Kim, B.C.3    Gu, M.B.4
  • 9
    • 53149124088 scopus 로고    scopus 로고
    • Microbial reporters of metal bioavailability
    • Magrisso, S.; Erel, Y.; Belkin, S. Microbial reporters of metal bioavailability Microb. Biotechnol. 2008, 1, 320-330
    • (2008) Microb. Biotechnol. , vol.1 , pp. 320-330
    • Magrisso, S.1    Erel, Y.2    Belkin, S.3
  • 10
    • 66249095651 scopus 로고    scopus 로고
    • A suite of recombinant luminescent bacterial strains for the quantification of bioavailable heavy metals and toxicity testing
    • Ivask, A.; Rõlova, T.; Kahru, A. A suite of recombinant luminescent bacterial strains for the quantification of bioavailable heavy metals and toxicity testing BMC Biotechnol. 2009, 9, 41
    • (2009) BMC Biotechnol. , vol.9 , pp. 41
    • Ivask, A.1    Rõlova, T.2    Kahru, A.3
  • 11
    • 0031867547 scopus 로고    scopus 로고
    • A chromosomally based tod-luxCDABE whole-cell reporter for benzene, toluene, ethybenzene, and xylene (BTEX) sensing
    • Applegate, B. M.; Kehrmeyer, S. R.; Sayler, G. S. A chromosomally based tod-luxCDABE whole-cell reporter for benzene, toluene, ethylbenzene, and xylene (BTEX) sensing Appl. Environ. Microbiol. 1998, 64, 2730-2735 (Pubitemid 28303329)
    • (1998) Applied and Environmental Microbiology , vol.64 , Issue.7 , pp. 2730-2735
    • Applegate, B.M.1    Kehrmeyer, S.R.2    Sayler, G.S.3
  • 12
    • 0026762358 scopus 로고
    • Specific and quantitative assessment of naphthalene and salicylate bioavailability by using a bioluminescent catabolic reporter bacterium
    • Heitzer, A.; Webb, O. F.; Thonnard, J. E.; Sayler, G. S. Specific and quantitative assessment of naphthalene and salicylate bioavailability by using a bioluminescent catabolic reporter bacterium Appl. Environ. Microbiol. 1992, 58, 1839-1846
    • (1992) Appl. Environ. Microbiol. , vol.58 , pp. 1839-1846
    • Heitzer, A.1    Webb, O.F.2    Thonnard, J.E.3    Sayler, G.S.4
  • 14
    • 12844275415 scopus 로고    scopus 로고
    • An integrated mini biosensor system for continuous water toxicity monitoring
    • DOI 10.1016/j.bios.2004.06.036, PII S0956566304003021
    • Lee, J. H.; Gu, M. B. An integrated mini biosensor system for continuous water toxicity monitoring Biosens. Bioelectron. 2005, 20, 1744-1749 (Pubitemid 40170142)
    • (2005) Biosensors and Bioelectronics , vol.20 , Issue.9 , pp. 1744-1749
    • Lee, J.H.1    Gu, M.B.2
  • 15
    • 27744501514 scopus 로고    scopus 로고
    • A multi-channel continuous water toxicity monitoring system: Its evaluation and application to water discharged from a power plant
    • DOI 10.1007/s10661-005-5843-7
    • Kim, B. C.; Gu, M. B. A multi-channel continuous water toxicity monitoring system: its evaluation and application to water discharged from a power plant Environ. Monit. Assess. 2005, 109, 123-133 (Pubitemid 41631077)
    • (2005) Environmental Monitoring and Assessment , vol.109 , Issue.1-3 , pp. 123-133
    • Kim, B.C.1    Gu, M.B.2
  • 16
    • 31944434718 scopus 로고    scopus 로고
    • Advances in preservation methods: Keeping biosensor microorganisms alive and active
    • DOI 10.1016/j.copbio.2005.12.005, PII S0958166905001965, Analytical Biotechnology
    • Bjerketorp, J.; Håkansson, S.; Belkin, S.; Jansson, J. K. Advances in preservation methods: keeping biosensor microorganisms alive and active Curr. Opin. Biotechnol. 2006, 17, 43-49 (Pubitemid 43190756)
    • (2006) Current Opinion in Biotechnology , vol.17 , Issue.1 , pp. 43-49
    • Bjerketorp, J.1    Hakansson, S.2    Belkin, S.3    Jansson, J.K.4
  • 17
    • 0028209314 scopus 로고
    • Optical biosensor for environmental on-line monitoring of naphthalene and salicylate bioavailability with an immobilized bioluminescent catabolic reporter bacterium
    • Heitzer, A.; Malachowsky, K.; Thonnard, J. E.; Bienkowski, P. R.; White, D. C.; Sayler, G. S. Optical biosensor for environmental on-line monitoring of naphthalene and salicylate bioavailability with an immobilized bioluminescent catabolic reporter bacterium Appl. Environ. Microbiol. 1994, 60, 1487-1494 (Pubitemid 24144804)
    • (1994) Applied and Environmental Microbiology , vol.60 , Issue.5 , pp. 1487-1494
    • Heitzer, A.1    Malachowsky, K.2    Thonnard, J.E.3    Bienkowski, P.R.4    White, D.C.5    Sayler, G.S.6
  • 19
    • 33947222450 scopus 로고    scopus 로고
    • Technological conception of an optical biosensor with a disposable card for use with bioluminescent bacteria
    • DOI 10.1016/j.snb.2006.06.033, PII S0925400506004606
    • Horry, H.; Charrier, T.; Durand, M.-J.; Vrignaud, B.; Picart, P.; Daniel, P.; Thouand, G. Technological conception of an optical biosensor with a disposable card for use with bioluminescent bacteria Sens. Actuators, B 2007, 122, 527-534 (Pubitemid 46415664)
    • (2007) Sensors and Actuators, B: Chemical , vol.122 , Issue.2 , pp. 527-534
    • Horry, H.1    Charrier, T.2    Durand, M.-J.3    Vrignaud, B.4    Picart, P.5    Daniel, P.6    Thouand, G.7
  • 20
    • 79955569947 scopus 로고    scopus 로고
    • A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part I: Design and optimization of bioluminescent bacterial strains
    • Charrier, T.; Durand, M.-J.; Jouanneau, S.; Dion, M.; Pernetti, M.; Poncelet, D.; Thouand, G. A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part I: design and optimization of bioluminescent bacterial strains Anal. Bioanal. Chem. 2011, 400, 1051-1060
    • (2011) Anal. Bioanal. Chem. , vol.400 , pp. 1051-1060
    • Charrier, T.1    Durand, M.-J.2    Jouanneau, S.3    Dion, M.4    Pernetti, M.5    Poncelet, D.6    Thouand, G.7
  • 21
    • 79955566734 scopus 로고    scopus 로고
    • A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part II: Technical development and proof of concept of the biosensor
    • Charrier, T.; Chapeau, C.; Bendria, L.; Picart, P.; Daniel, P.; Thouand, G. A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part II: technical development and proof of concept of the biosensor Anal. Bioanal. Chem. 2011, 400, 1061-1070
    • (2011) Anal. Bioanal. Chem. , vol.400 , pp. 1061-1070
    • Charrier, T.1    Chapeau, C.2    Bendria, L.3    Picart, P.4    Daniel, P.5    Thouand, G.6
  • 22
    • 77953605121 scopus 로고    scopus 로고
    • Strategies for enhancing bioluminescent bacterial sensor performance by promoter region manipulation
    • Yagur-Kroll, S.; Bilic, B.; Belkin, S. Strategies for enhancing bioluminescent bacterial sensor performance by promoter region manipulation Microb. Biotechnol. 2010, 3, 300-310
    • (2010) Microb. Biotechnol. , vol.3 , pp. 300-310
    • Yagur-Kroll, S.1    Bilic, B.2    Belkin, S.3
  • 23
    • 0031965086 scopus 로고    scopus 로고
    • The sequence of spacers between the consensus sequences modulates the strength of prokaryotic promoters
    • Jensen, P.; Hammer, K. The sequence of spacers between the consensus sequences modulates the strength of prokaryotic promoters Appl. Environ. Microbiol. 1998, 64, 82-87 (Pubitemid 28040295)
    • (1998) Applied and Environmental Microbiology , vol.64 , Issue.1 , pp. 82-87
    • Jensen, P.R.1    Hammer, K.2
  • 24
    • 60449093642 scopus 로고    scopus 로고
    • Modeling and measurement of a whole-cell bioluminescent biosensor based on a single photon avalanche diode
    • Daniel, R.; Almog, R.; Ron, A.; Belkin, S.; Shacham-Diamand, Y. Modeling and measurement of a whole-cell bioluminescent biosensor based on a single photon avalanche diode Biosens. Bioelectron. 2008, 24, 882-887
    • (2008) Biosens. Bioelectron. , vol.24 , pp. 882-887
    • Daniel, R.1    Almog, R.2    Ron, A.3    Belkin, S.4    Shacham-Diamand, Y.5
  • 26
    • 0142027136 scopus 로고    scopus 로고
    • Development of a set of simple bacterial biosensors for quantitative and rapid measurements of arsenite and arsenate in potable water
    • DOI 10.1021/es034258b
    • Stocker, J.; Balluch, D.; Gsell, M.; Harms, H.; Feliciano, J.; Daunert, S.; Malik, K. A.; van der Meer, J. R. Development of a set of simple bacterial biosensors for quantitative and rapid measurements of arsenite and arsenate in potable water Environ. Sci. Technol. 2003, 37, 4743-4750 (Pubitemid 37266395)
    • (2003) Environmental Science and Technology , vol.37 , Issue.20 , pp. 4743-4750
    • Stocker, J.1    Balluch, D.2    Gsell, M.3    Harms, H.4    Feliciano, J.5    Daunert, S.6    Malik, K.A.7    Van Der Meer, J.R.8
  • 27
    • 0029809116 scopus 로고    scopus 로고
    • Monitoring subtoxic environmental hazards by stress-responsive luminous bacteria
    • DOI 10.1002/(SICI)1098-2256(1996)11:3<179::AID-TOX2>3.0.CO;2-6
    • Belkin, S.; Van Dyk, T. K.; Vollmer, A. C.; Smulski, D. R.; LaRossa, R. A. Monitoring subtoxic environmental hazards by stress-responsive luminous bacteria Environ. Toxicol. Water Qual. 1996, 11, 179-185 (Pubitemid 26334656)
    • (1996) Environmental Toxicology and Water Quality , vol.11 , Issue.3 , pp. 179-185
    • Belkin, S.1
  • 30
    • 0012381510 scopus 로고    scopus 로고
    • U.S. Environmental Protection Agency.
    • National primary drinking water regulations; U.S. Environmental Protection Agency, 2009; http://water.epa.gov/drink/contaminants/index.cfm#List.
    • (2009) National Primary Drinking Water Regulations
  • 32
    • 79955558843 scopus 로고    scopus 로고
    • Upgrading bioluminescent bacterial bioreporter performance by splitting the lux operon
    • Yagur-Kroll, S.; Belkin, S. Upgrading bioluminescent bacterial bioreporter performance by splitting the lux operon Anal. Bioanal. Chem. 2011, 400, 1071-1082
    • (2011) Anal. Bioanal. Chem. , vol.400 , pp. 1071-1082
    • Yagur-Kroll, S.1    Belkin, S.2
  • 33
    • 80053388090 scopus 로고    scopus 로고
    • Whole-cell biochips for bio-sensing: Integration of live cells and inanimate surfaces
    • DOI: 10.3109/07388551.2010.532767.
    • Ben-Yoav, H.; Melamed, S.; Freeman, A.; Shacham-Diamand, Y.; Belkin, S. Whole-cell biochips for bio-sensing: integration of live cells and inanimate surfaces. Crit. Rev. Biotechnol. 2010, DOI: 10.3109/07388551.2010.532767.
    • (2010) Crit. Rev. Biotechnol.
    • Ben-Yoav, H.1    Melamed, S.2    Freeman, A.3    Shacham-Diamand, Y.4    Belkin, S.5
  • 34
    • 0031540096 scopus 로고    scopus 로고
    • A panel of stress-responsive luminous bacteria for the detection of selected classes of toxicants
    • DOI 10.1016/S0043-1354(97)00169-3, PII S0043135497001693
    • Belkin, S.; Smulski, D. R.; Dadon, S.; Vollmer, A. C.; van Dyk, T. K.; LaRossa, R. A. A panel of stress-responsive luminous bacteria for the detection of selected classes of toxicants Water Res. 1997, 31, 3009-3016 (Pubitemid 27517346)
    • (1997) Water Research , vol.31 , Issue.12 , pp. 3009-3016
    • Belkin, S.1    Smulski, D.R.2    Dadon, S.3    Vollmer, A.C.4    Van Dyk, T.K.5    Larossa, R.A.6
  • 35
    • 0842265596 scopus 로고    scopus 로고
    • Bioluminescent bioreporter integrated circuits: Potentially small, rugged and inexpensive whole-cell biosensors for remote environmental monitoring
    • DOI 10.1046/j.1365-2672.2003.02114.x
    • Nivens, D. E.; McKnight, T. E.; Moser, S. A.; Osbourn, S. J.; Simpson, M. L.; Sayler, G. S. Bioluminescent bioreporter integrated circuits: potentially small, rugged and inexpensive whole-cell biosensors for remote environmental monitoring J. Appl. Microbiol. 2004, 96, 33-46 (Pubitemid 38177903)
    • (2004) Journal of Applied Microbiology , vol.96 , Issue.1 , pp. 33-46
    • Nivens, D.E.1    McKnight, T.E.2    Moser, S.A.3    Osbourn, S.J.4    Simpson, M.L.5    Sayler, G.S.6
  • 36
    • 0031790536 scopus 로고    scopus 로고
    • Identification and quantification of toxic chemicals by use of Escherichia coli carrying lux genes fused to stress promoters
    • Ben-Israel, O.; Ben-Israel, H.; Ulitzur, S. Identification and quantification of toxic chemicals by use of Escherichia coli carrying lux genes fused to stress promoters Appl. Environ. Microbiol. 1998, 64, 4346-4352 (Pubitemid 28537999)
    • (1998) Applied and Environmental Microbiology , vol.64 , Issue.11 , pp. 4346-4352
    • Ben-Israel, O.1    Ben-Israel, H.2    Ulitzur, S.3
  • 37
    • 56449112780 scopus 로고    scopus 로고
    • Toxicant identification by a luminescent bacterial bioreporter panel: Application of pattern classification algorithms
    • Elad, T.; Benovich, E.; Magrisso, S.; Belkin, S. Toxicant identification by a luminescent bacterial bioreporter panel: application of pattern classification algorithms Environ. Sci. Technol. 2008, 42, 8486-8491
    • (2008) Environ. Sci. Technol. , vol.42 , pp. 8486-8491
    • Elad, T.1    Benovich, E.2    Magrisso, S.3    Belkin, S.4
  • 38
    • 68949170814 scopus 로고    scopus 로고
    • Identification of β-lactam antibiotics using bioluminescent Escherichia coli and a support vector machine classifier algorithm
    • Smolander, O.-P.; Ribeiro, A. S.; Yli-Harja, O.; Karp, M. Identification of β-lactam antibiotics using bioluminescent Escherichia coli and a support vector machine classifier algorithm Sens. Actuators, B 2009, 141, 604-609
    • (2009) Sens. Actuators, B , vol.141 , pp. 604-609
    • Smolander, O.-P.1    Ribeiro, A.S.2    Yli-Harja, O.3    Karp, M.4
  • 39
    • 79953252225 scopus 로고    scopus 로고
    • Improvement of the identification of four heavy metals in environmental samples by using predictive decision tree models coupled with a set of five bioluminescent bacteria
    • Jouanneau, S.; Durand, M.-J.; Courcoux, P.; Blusseau, T.; Thouand, G. Improvement of the identification of four heavy metals in environmental samples by using predictive decision tree models coupled with a set of five bioluminescent bacteria Environ. Sci. Technol. 2011, 45, 2925-2931
    • (2011) Environ. Sci. Technol. , vol.45 , pp. 2925-2931
    • Jouanneau, S.1    Durand, M.-J.2    Courcoux, P.3    Blusseau, T.4    Thouand, G.5
  • 40
    • 0038695870 scopus 로고    scopus 로고
    • A bioluminescent sensor for high throughput toxicity classification
    • DOI 10.1016/S0956-5663(02)00220-8, PII S0956566302002208
    • Kim, B. C.; Gu, M. B. A bioluminescent sensor for high throughput toxicity classification Biosens. Bioelectron. 2003, 18, 1015-1021 (Pubitemid 36627984)
    • (2003) Biosensors and Bioelectronics , vol.18 , Issue.8 , pp. 1015-1021
    • Kim, B.C.1    Gu, M.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.