Volumn 41, Issue 3, 2004, Pages 237-240

Pneumatic tube system induced haemolysis: Assessing sample type susceptibility to haemolysis

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BIOCHEMISTRY; BLOOD SAMPLING; GEL; HEMOLYSIS; HOSPITAL DESIGN; HUMAN; LABORATORY; PNEUMATIC TOOL; PNEUMATIC TUBE SYSTEM; PRIORITY JOURNAL; PROTECTION; SERUM; SPECTROPHOTOMETRY;

EID: 2442429634     PISSN: 00045632     EISSN: None     Source Type: Journal    
DOI: 10.1258/000456304323019631     Document Type: Article
Times cited : (59)

References (7)
  • 1
    • 0036729269 scopus 로고    scopus 로고
    • Discrepancy between visual and spectrophotometric assessment of sample haemolysis
    • Hawkins R. Discrepancy between visual and spectrophotometric assessment of sample haemolysis. Ann Clin Biochem 2002; 39: 521-2
    • (2002) Ann Clin Biochem , vol.39 , pp. 521-522
    • Hawkins, R.1
  • 2
    • 0033798463 scopus 로고    scopus 로고
    • The haemolytic, icteric and lipaemic sample recommendations regarding their recognition and prevention of clinically relevant interferences
    • Guder WG, da Fonseca-Wollheim F, Heil W, Schnitt YM, Topfer G, Wisser H, et al. The haemolytic, icteric and lipaemic sample recommendations regarding their recognition and prevention of clinically relevant interferences. J Lab Med 2000; 24: 357-64
    • (2000) J Lab Med , vol.24 , pp. 357-364
    • Guder, W.G.1    Da Fonseca-Wollheim, F.2    Heil, W.3    Schnitt, Y.M.4    Topfer, G.5    Wisser, H.6
  • 3
    • 0037596706 scopus 로고    scopus 로고
    • Haemolysis interference in the Ortho-Clinical Diagnostics Vitros ECi cTnI assay
    • Hawkins R. Haemolysis interference in the Ortho-Clinical Diagnostics Vitros ECi cTnI assay. Clin Chem 2003; 49: 1226
    • (2003) Clin Chem , vol.49 , pp. 1226
    • Hawkins, R.1
  • 5
    • 0026605279 scopus 로고
    • Evaluation of a soft-handling computerized pneumatic tube specimen delivery system: Effects on analytical results and turnaround time
    • Keshgegian AA, Bull GE. Evaluation of a soft-handling computerized pneumatic tube specimen delivery system: effects on analytical results and turnaround time. Am J Clin Pathol 1992; 97: 535-40
    • (1992) Am J Clin Pathol , vol.97 , pp. 535-540
    • Keshgegian, A.A.1    Bull, G.E.2
  • 6
    • 0022885477 scopus 로고
    • Graphical comparisons of interferences in clinical chemistry instrumentation
    • Glick MR, Ryder KW, Jackson SA. Graphical comparisons of interferences in clinical chemistry instrumentation. Clin Chem 1986; 32: 470-5
    • (1986) Clin Chem , vol.32 , pp. 470-475
    • Glick, M.R.1    Ryder, K.W.2    Jackson, S.A.3
  • 7
    • 2442628286 scopus 로고    scopus 로고
    • Automation in the clinical laboratory
    • Burtis CA, Ashwood ER, eds. Philadelphia: WB Saunders
    • Boyd JC, Young DS. Automation in the clinical laboratory. In: Burtis CA, Ashwood ER, eds. Tietz Fundamentals of Clinical Chemistry, 5th edn. Philadelphia: WB Saunders, 2001: 217
    • (2001) Tietz Fundamentals of Clinical Chemistry, 5th Edn. , pp. 217
    • Boyd, J.C.1    Young, D.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.