메뉴 건너뛰기




Volumn 212, Issue 2, 2011, Pages 426-430

Non-uniformity correction of human brain imaging at high field by RF field mapping of B 1 + and B 1 -

Author keywords

High field; Human brain; Non uniformity; RF field

Indexed keywords

HIGH FIELD; HOMOGENEOUS EXCITATION; HUMAN BRAIN; IMAGE CORRECTION; IN-VIVO; INVERSION RECOVERY; NONUNIFORMITY; NONUNIFORMITY CORRECTION; PHASE METHODS; POLYNOMIAL FUNCTIONS; RECEPTION FIELDS; RF FIELDS; RF TRANSMISSION; SIGNAL INTENSITIES; SPATIAL PATTERNS; SPIN ECHO; WATER FRACTION; WHITE MATTER;

EID: 80053255127     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2011.08.001     Document Type: Article
Times cited : (13)

References (15)
  • 1
    • 20444501009 scopus 로고    scopus 로고
    • Unified segmentation
    • DOI 10.1016/j.neuroimage.2005.02.018, PII S1053811905001102
    • J. Ashburner, and K.J. Friston Unified segmentation NeuroImage 26 2005 839 851 (Pubitemid 40825026)
    • (2005) NeuroImage , vol.26 , Issue.3 , pp. 839-851
    • Ashburner, J.1    Friston, K.J.2
  • 4
    • 0034405181 scopus 로고    scopus 로고
    • The principle of reciprocity in signal strength calculations - A mathematical guide
    • D.I. Hoult The principle of reciprocity in signal strength calculations - a mathematical guide Concepts Magn. Reson. 12 2000 173 183
    • (2000) Concepts Magn. Reson. , vol.12 , pp. 173-183
    • Hoult, D.I.1
  • 5
    • 0036238849 scopus 로고    scopus 로고
    • Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz
    • DOI 10.1002/mrm.10153
    • C.M. Collins, Q.X. Yang, J.H. Wang, X. Zhang, H. Liu, S. Michaeli, X.-H. Zu, G. Adriany, J.T. Vaughan, P. Anderson, H. Merkle, K. Uurbil, M.B. Smith, and W. Chen Different excitation and reception distributions with a single-loop transmit-receive surface coil near head-sized spherical phantom at 300 MHz Magn. Reson. Med. 47 2002 1026 1028 (Pubitemid 34454064)
    • (2002) Magnetic Resonance in Medicine , vol.47 , Issue.5 , pp. 1026-1028
    • Vaughan, J.T.1    Adriany, G.2    Garwood, M.3    Yacoub, E.4    Duong, T.5    Delabarre, L.6    Andersen, P.7    Ugurbil, K.8
  • 9
    • 80054820091 scopus 로고    scopus 로고
    • 1 mapping using phase information created by frequency-modulated pulses
    • Tronto, Canada
    • 1 mapping using phase information created by frequency-modulated pulses, in: Proceedings of the 16th Annual Meeting ISMRM, Tronto, Canada, 2008, p. 361.
    • (2008) Proceedings of the 16th Annual Meeting ISMRM , pp. 361
    • Park, J.Y.1    Garwood, M.2
  • 11
    • 12844266240 scopus 로고    scopus 로고
    • Measurement and correction of transmitter and receiver induced nonuniformities in vivo
    • DOI 10.1002/mrm.20354
    • J. Wang, M. Qiu, Q.X. Yang, M.B. Smith, and R.T. Constable Measurement and correction of transmitter and receiver induced nonuniformities in vivo Magn. Reson. Med. 53 2005 408 417 (Pubitemid 40171055)
    • (2005) Magnetic Resonance in Medicine , vol.53 , Issue.2 , pp. 408-417
    • Wang, J.1    Qiu, M.2    Yang, Q.X.3    Smith, M.B.4    Constable, R.T.5
  • 12
    • 35948977751 scopus 로고    scopus 로고
    • Apparent transverse relaxation rate in human brain varies linearly with tissue iron concentration at 4.7 T
    • DOI 10.1002/mrm.21373
    • F. Mitsumori, H. Watanabe, N. Takaya, and M. Garwood Apparent transverse relaxation rate in human brain varies linearly with tissue iron concentration at 4.7 T Magn. Reson. Med. 58 2007 1054 1060 (Pubitemid 350074374)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.5 , pp. 1054-1060
    • Mitsumori, F.1    Watanabe, H.2    Takaya, N.3    Garwood, M.4
  • 13
    • 70449371466 scopus 로고    scopus 로고
    • Estimation of brain iron concentration in vivo using a linear relationship between regional iron and apparent transverse relaxation rate of the tissue water at 4.7 T
    • F. Mitsumori, H. Watanabe, and N. Takaya Estimation of brain iron concentration in vivo using a linear relationship between regional iron and apparent transverse relaxation rate of the tissue water at 4.7 T Magn. Reson. Med. 62 2009 1326 1330
    • (2009) Magn. Reson. Med. , vol.62 , pp. 1326-1330
    • Mitsumori, F.1    Watanabe, H.2    Takaya, N.3
  • 14
    • 0006580714 scopus 로고
    • Chemical topography of the brain
    • O. Lowell, and L.O. Randall Chemical topography of the brain J. Biol. Chem. 124 1938 481 488
    • (1938) J. Biol. Chem. , vol.124 , pp. 481-488
    • Lowell, O.1    Randall, L.O.2
  • 15
    • 0035157986 scopus 로고    scopus 로고
    • Interregional variation of longitudinal relaxation rates in human brain at 3.0 T: Relation to estimated iron and water contents
    • DOI 10.1002/1522-2594(200101)45: 1<71::AID-MRM1011>3.0.CO;2-2
    • N. Gelman, J.R. Ewing, J.M. Gorell, E.M. Spickler, and E.G. Solomon Interregional variation of longitudinal relaxation rates in human brain at 3.0 T: relaxation to estimated iron and water contents Magn. Reson. Med. 45 2001 71 79 (Pubitemid 32044267)
    • (2001) Magnetic Resonance in Medicine , vol.45 , Issue.1 , pp. 71-79
    • Gelman, N.1    Ewing, J.R.2    Gorell, J.M.3    Spickler, E.M.4    Solomon, E.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.