메뉴 건너뛰기




Volumn 26, Issue 7, 2011, Pages 1045-1049

Revision Total Hip Arthroplasty Using a Tapered, Press-Fit Cementless Revision Stem in Elderly Patients

Author keywords

Cementless; Elderly; Femoral stem; Osteoporosis; Press fit; Revision total hip arthroplasty; Tapered

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; FEMALE; FOLLOW UP; HARRIS HIP SCORE; HUMAN; MALE; PATIENT MONITORING; POSTOPERATIVE PERIOD; REOPERATION; RETROSPECTIVE STUDY; TOTAL HIP PROSTHESIS;

EID: 80053195502     PISSN: 08835403     EISSN: 15328406     Source Type: Journal    
DOI: 10.1016/j.arth.2011.03.020     Document Type: Article
Times cited : (14)

References (20)
  • 1
    • 21444440419 scopus 로고    scopus 로고
    • Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002
    • Kurtz S., Mowat F., Ong K., et al. Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. J Bone Joint Surg Am 2005, 87:1487.
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 1487
    • Kurtz, S.1    Mowat, F.2    Ong, K.3
  • 2
    • 67949109626 scopus 로고    scopus 로고
    • High medium-term survival of Zweymuller SLR-plus stem used in femoral revision
    • Korovessis P., Repantis T. High medium-term survival of Zweymuller SLR-plus stem used in femoral revision. Clin Orthop Relat Res 2009, 467:2032.
    • (2009) Clin Orthop Relat Res , vol.467 , pp. 2032
    • Korovessis, P.1    Repantis, T.2
  • 3
    • 0029849809 scopus 로고    scopus 로고
    • Aging effect on inductive capacity of human demineralized bone matrix
    • Nyssen-Behets C., Delaere O., Duchesne P.Y., et al. Aging effect on inductive capacity of human demineralized bone matrix. Arch Orthop Trauma Surg 1996, 115:303.
    • (1996) Arch Orthop Trauma Surg , vol.115 , pp. 303
    • Nyssen-Behets, C.1    Delaere, O.2    Duchesne, P.Y.3
  • 4
    • 0026322309 scopus 로고
    • Fixation of titanium and hydroxyapatite-coated implants in arthritic osteopenic bone
    • Soballe K., Hansen E.S., Brockstedt-Rasmussen H., et al. Fixation of titanium and hydroxyapatite-coated implants in arthritic osteopenic bone. J Arthroplasty 1991, 6:307.
    • (1991) J Arthroplasty , vol.6 , pp. 307
    • Soballe, K.1    Hansen, E.S.2    Brockstedt-Rasmussen, H.3
  • 5
    • 0032786654 scopus 로고    scopus 로고
    • Minimum 10-year-results of extensively porous-coated stems in revision hip arthroplasty
    • Paprosky W.G., Greidanus N.V., Antoniou J. Minimum 10-year-results of extensively porous-coated stems in revision hip arthroplasty. Clin Orthop Relat Res 1999, 230.
    • (1999) Clin Orthop Relat Res , pp. 230
    • Paprosky, W.G.1    Greidanus, N.V.2    Antoniou, J.3
  • 6
    • 0018687995 scopus 로고
    • "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening
    • Gruen T.A., McNeice G.M., Amstutz H.C. "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 1979, 17.
    • (1979) Clin Orthop Relat Res , pp. 17
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 7
    • 0023777583 scopus 로고
    • The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty
    • Engh C.A., Bobyn J.D. The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop Relat Res 1988, 7.
    • (1988) Clin Orthop Relat Res , pp. 7
    • Engh, C.A.1    Bobyn, J.D.2
  • 8
    • 0023240947 scopus 로고
    • Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results
    • Engh C.A., Bobyn J.D., Glassman A.H. Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br 1987, 69:45.
    • (1987) J Bone Joint Surg Br , vol.69 , pp. 45
    • Engh, C.A.1    Bobyn, J.D.2    Glassman, A.H.3
  • 9
    • 0023816128 scopus 로고
    • Reduction in cement-bone interface shear strength between primary and revision arthroplasty
    • Dohmae Y., Bechtold J.E., Sherman R.E., et al. Reduction in cement-bone interface shear strength between primary and revision arthroplasty. Clin Orthop Relat Res 1988, 214.
    • (1988) Clin Orthop Relat Res , pp. 214
    • Dohmae, Y.1    Bechtold, J.E.2    Sherman, R.E.3
  • 10
    • 0033755534 scopus 로고    scopus 로고
    • Clinical experience with a modular noncemented femoral component in revision total hip arthroplasty: 4- to 7-year results
    • Christie M.J., DeBoer D.K., Tingstad E.M., et al. Clinical experience with a modular noncemented femoral component in revision total hip arthroplasty: 4- to 7-year results. J Arthroplasty 2000, 15:840.
    • (2000) J Arthroplasty , vol.15 , pp. 840
    • Christie, M.J.1    DeBoer, D.K.2    Tingstad, E.M.3
  • 11
    • 0037629058 scopus 로고    scopus 로고
    • A modular distal fixation option for proximal bone loss in revision total hip arthroplasty: a 2- to 6-year follow-up study
    • Kwong L.M., Miller A.J., Lubinus P. A modular distal fixation option for proximal bone loss in revision total hip arthroplasty: a 2- to 6-year follow-up study. J Arthroplasty 2003, 18:94.
    • (2003) J Arthroplasty , vol.18 , pp. 94
    • Kwong, L.M.1    Miller, A.J.2    Lubinus, P.3
  • 12
    • 0031443563 scopus 로고    scopus 로고
    • 5- to 13-year follow-up study on cementless femoral components in revision surgery
    • Krishnamurthy A.B., MacDonald S.J., Paprosky W.G. 5- to 13-year follow-up study on cementless femoral components in revision surgery. J Arthroplasty 1997, 12:839.
    • (1997) J Arthroplasty , vol.12 , pp. 839
    • Krishnamurthy, A.B.1    MacDonald, S.J.2    Paprosky, W.G.3
  • 14
    • 80053215024 scopus 로고    scopus 로고
    • Minimum 5-year follow-up of a cementless, modular, tapered stem in hip revision arthroplasty
    • Weiss R.J., Beckman M.O., Enocson A., et al. Minimum 5-year follow-up of a cementless, modular, tapered stem in hip revision arthroplasty. J Arthroplasty 2010, 8.
    • (2010) J Arthroplasty , pp. 8
    • Weiss, R.J.1    Beckman, M.O.2    Enocson, A.3
  • 15
    • 1442356148 scopus 로고    scopus 로고
    • Intraoperative fracture of the femur in revision total hip arthroplasty with a diaphyseal fitting stem
    • Meek R.M., Garbuz D.S., Masri B.A., et al. Intraoperative fracture of the femur in revision total hip arthroplasty with a diaphyseal fitting stem. J Bone Joint Surg Am 2004, 86A:480.
    • (2004) J Bone Joint Surg Am , vol.86 A , pp. 480
    • Meek, R.M.1    Garbuz, D.S.2    Masri, B.A.3
  • 16
    • 0030453655 scopus 로고    scopus 로고
    • The Wagner revision stem for severe osteolysis. 31 hips followed for 1.5-5 years
    • Kolstad K., Adalberth G., Mallmin H., et al. The Wagner revision stem for severe osteolysis. 31 hips followed for 1.5-5 years. Acta Orthop Scand 1996, 67:541.
    • (1996) Acta Orthop Scand , vol.67 , pp. 541
    • Kolstad, K.1    Adalberth, G.2    Mallmin, H.3
  • 17
    • 0036933190 scopus 로고    scopus 로고
    • Femoral revision using the Wagner stem: results at 2-9 years
    • Weber M., Hempfing A., Orler R., et al. Femoral revision using the Wagner stem: results at 2-9 years. Int Orthop 2002, 26:36.
    • (2002) Int Orthop , vol.26 , pp. 36
    • Weber, M.1    Hempfing, A.2    Orler, R.3
  • 18
    • 42449125631 scopus 로고    scopus 로고
    • Fifteen- to 20-year results of uncemented tapered fully porous-coated cobalt-chrome stems
    • Yoon T.R., Rowe S.M., Kim M.S., et al. Fifteen- to 20-year results of uncemented tapered fully porous-coated cobalt-chrome stems. Int Orthop 2008, 32:317.
    • (2008) Int Orthop , vol.32 , pp. 317
    • Yoon, T.R.1    Rowe, S.M.2    Kim, M.S.3
  • 19
    • 0345060427 scopus 로고    scopus 로고
    • Clinical consequences of stress shielding after porous-coated total hip arthroplasty
    • Engh C.A., Young A.M., Engh C.A., et al. Clinical consequences of stress shielding after porous-coated total hip arthroplasty. Clin Orthop Relat Res 2003, 157.
    • (2003) Clin Orthop Relat Res , pp. 157
    • Engh, C.A.1    Young, A.M.2    Engh, C.A.3
  • 20
    • 0035160786 scopus 로고    scopus 로고
    • The uncemented fully textured Lord hip prosthesis: a 10- to 15-year followup study
    • Keisu K.S., Mathiesen E.B., Lindgren J.U. The uncemented fully textured Lord hip prosthesis: a 10- to 15-year followup study. Clin Orthop Relat Res 2001, 133.
    • (2001) Clin Orthop Relat Res , pp. 133
    • Keisu, K.S.1    Mathiesen, E.B.2    Lindgren, J.U.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.