-
1
-
-
42949093113
-
Type 2 Diabetes Mellitus and Skeletal Muscle Metabolic Function
-
DOI 10.1016/j.physbeh.2008.01.020, PII S0031938408000231
-
Phielix E, Mensink M,. Type 2 diabetes mellitus and skeletal muscle metabolic function. Physiol Behav 2008; 94: 252-258. (Pubitemid 351615433)
-
(2008)
Physiology and Behavior
, vol.94
, Issue.2
, pp. 252-258
-
-
Phielix, E.1
Mensink, M.2
-
2
-
-
0026919666
-
The contribution made by cell-death and oxygenation to P-31 MRS observations of tumor energy-metabolism
-
Tozer GM, Griffiths JR,. The contribution made by cell-death and oxygenation to P-31 MRS observations of tumor energy-metabolism. NMR Biomed 1992; 5: 279-289.
-
(1992)
NMR Biomed
, vol.5
, pp. 279-289
-
-
Tozer, G.M.1
Griffiths, J.R.2
-
3
-
-
0038080971
-
31P-MR spectroscopy in children and adolescents with a familial risk of schizophrenia
-
31P-MR spectroscopy in children and adolescents with a familial risk of schizophrenia. Eur Radiol 2003; 13: 763-770. (Pubitemid 36790559)
-
(2003)
European Radiology
, vol.13
, Issue.4
, pp. 763-770
-
-
Rzanny, R.1
Klemm, S.2
Reichenbach, J.R.3
Pfleiderer, S.O.R.4
Schmidt, B.5
Volz, H.-P.6
Blanz, B.7
Kaiser, W.A.8
-
4
-
-
57149097868
-
Efficient H-1 to P-31 polarization transfer on a clinical 3 T MR system
-
Klomp DWJ, Wijnen JP, Scheenen TWJ, Heerschap A,. Efficient H-1 to P-31 polarization transfer on a clinical 3 T MR system. Magn Reson Med 2008; 60: 1298-1305.
-
(2008)
Magn Reson Med
, vol.60
, pp. 1298-1305
-
-
Klomp, D.W.J.1
Wijnen, J.P.2
Scheenen, T.W.J.3
Heerschap, A.4
-
5
-
-
53549119448
-
Three-dimensional high-resolution magnetic resonance spectroscopic imaging for absolute quantification of P-31 metabolites in human liver
-
Chmelik M, Schmid AI, Gruber S, Szendroedi J, Krssak M, Trattnig S, Moser E, Roden M,. Three-dimensional high-resolution magnetic resonance spectroscopic imaging for absolute quantification of P-31 metabolites in human liver. Magn Reson Med 2008; 60: 796-802.
-
(2008)
Magn Reson Med
, vol.60
, pp. 796-802
-
-
Chmelik, M.1
Schmid, A.I.2
Gruber, S.3
Szendroedi, J.4
Krssak, M.5
Trattnig, S.6
Moser, E.7
Roden, M.8
-
6
-
-
42549093619
-
31P CSI: A feasible approach for the study of membrane turnover in the human brain
-
DOI 10.1002/mrm.21588
-
Wokrina T, Ulrich M, Weber-Fahr W, Ende G,. 3D RINEPT {H-1}-P-31 CSI: a feasible approach for the study of membrane turnover in the human brain. Magn Reson Med 2008; 59: 999-1004. (Pubitemid 351590512)
-
(2008)
Magnetic Resonance in Medicine
, vol.59
, Issue.5
, pp. 999-1004
-
-
Wokrina, T.1
Ulrich, M.2
Weber-Fahr, W.3
Ende, G.4
-
7
-
-
42449141070
-
31P MR spectroscopic assessment of muscle in patients with myasthenia gravis before and after thymectomy: Initial experience
-
31P MR spectroscopic assessment of muscle in patients with myasthenia gravis before and after thymectomy: initial experience. Radiology 2008; 247: 162-169.
-
(2008)
Radiology
, vol.247
, pp. 162-169
-
-
Ko, S.F.1
Huang, C.C.2
Hsieh, M.J.3
Ng, S.H.4
Lee, C.C.5
Lin, T.K.6
Chen, M.C.7
Lee, L.8
-
8
-
-
33745815602
-
31P-MR spectroscopic imaging in hypertensive heart disease
-
DOI 10.1007/s00330-006-0170-0
-
Heyne JP, Rzanny R, Hansch A, Leder U, Reichenbach JR, Kaiser WA,. P-31-MR spectroscopic imaging in hypertensive heart disease. Eur Radiol 2006; 16: 1796-1802. (Pubitemid 44027383)
-
(2006)
European Radiology
, vol.16
, Issue.8
, pp. 1796-1802
-
-
Heyne, J.-P.1
Rzanny, R.2
Hansch, A.3
Leder, U.4
Reichenbach, J.R.5
Kaiser, W.A.6
-
9
-
-
5044237124
-
31P MR spectroscopy in human cancer research. In vitro and normal volunteer studies
-
DOI 10.1002/nbm.915
-
Arias-Mendoza F, Zakian K, Schwartz A, Howe FA, Koutcher JA, Leach MO, Griffiths JR, Heerschap A, Glickson JD, Nelson SJ, Evelhoch JL, Charles HC, Brown TR,; Cooperative Group on MRS Applications in Cancer. Methodological standardization for a multi-institutional in vivo trial of localized P-31 MR spectroscopy in human cancer research. In vitro and normal volunteer studies. NMR Biomed 2004; 17: 382-391. (Pubitemid 39335176)
-
(2004)
NMR in Biomedicine
, vol.17
, Issue.6
, pp. 382-391
-
-
Arias-Mendoza, F.1
Zakian, K.2
Schwartz, A.3
Howe, F.A.4
Koutcher, J.A.5
Leach, M.O.6
Griffiths, J.R.7
Heerschap, A.8
Glickson, J.D.9
Nelson, S.J.10
Evelhoch, J.L.11
Charles, H.C.12
Brown, T.R.13
Murphy-Boesch, J.14
Stoyanova, R.15
Kappler, F.16
Negendank, W.G.17
Ballon, D.18
Payne, G.19
-
10
-
-
69449088543
-
Assessment of P-31 relaxation times in the human calf muscle: A comparison between 3 T and 7 T in vivo
-
Bogner W, Chmelik M, Schmid AI, Moser E, Trattnig S, Gruber S,. Assessment of P-31 relaxation times in the human calf muscle: a comparison between 3 T and 7 T in vivo. Magn Reson Med 2009; 62: 574-582.
-
(2009)
Magn Reson Med
, vol.62
, pp. 574-582
-
-
Bogner, W.1
Chmelik, M.2
Schmid, A.I.3
Moser, E.4
Trattnig, S.5
Gruber, S.6
-
11
-
-
0037310043
-
31P magnetic resonance spectroscopy of human brain at 7 T: An initial experience
-
DOI 10.1002/mrm.10379
-
Lei H, Zhu XH, Zhang XL, Ugurbil K, Chen W,. In vivo P-31 magnetic resonance spectroscopy of human brain at 7 T: an initial experience. Magn Reson Med 2003; 49: 199-205. (Pubitemid 36159855)
-
(2003)
Magnetic Resonance in Medicine
, vol.49
, Issue.2
, pp. 199-205
-
-
Lei, H.1
Zhu, X.-H.2
Zhang, X.-L.3
Ugurbil, K.4
Chen, W.5
-
12
-
-
34548716597
-
31P MRS of human brain at high/ultrahigh fields: A quantitative comparison of NMR detection sensitivity and spectral resolution between 4 T and 7 T
-
DOI 10.1016/j.mri.2006.08.002, PII S0730725X06002402
-
Qiao H, Zhang XL, Zhu XH, Du F, Chen W,. In vivo 31P MRS of human brain at high/ultrahigh fields: a quantitative comparison of NMR detection sensitivity and spectral resolution between 4 T and 7 T. Magn Reson Imaging 2006; 24: 1281-1286. (Pubitemid 44827580)
-
(2006)
Magnetic Resonance Imaging
, vol.24
, Issue.10
, pp. 1281-1286
-
-
Qiao, H.1
Zhang, X.2
Zhu, X.-H.3
Du, F.4
Chen, W.5
-
13
-
-
33746850826
-
Spatial localization in nuclear magnetic resonance spectroscopy
-
DOI 10.1088/0031-9155/51/16/R01, PII S0031915506360915, R01
-
Keevil SF,. Spatial localization in nuclear magnetic resonance spectroscopy. Phys Med Biol 2006; 51: R579-R636. (Pubitemid 44177395)
-
(2006)
Physics in Medicine and Biology
, vol.51
, Issue.16
-
-
Keevil, S.F.1
-
14
-
-
41949093884
-
Image-selected in vivo spectroscopy (ISIS)-a new technique for spatially selective NMR-spectroscopy
-
Ordidge RJ, Connelly A, Lohman JAB,. Image-selected in vivo spectroscopy (ISIS)-a new technique for spatially selective NMR-spectroscopy. J Magn Reson 1986; 66: 283-294.
-
(1986)
J Magn Reson
, vol.66
, pp. 283-294
-
-
Ordidge, R.J.1
Connelly, A.2
Lohman, J.A.B.3
-
15
-
-
0029782594
-
Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy
-
Ordidge RJ, Wylezinska M, Hugg JW, Butterworth E, Franconi F,. Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy. Magn Reson Med 1996; 36: 562-566. (Pubitemid 26330876)
-
(1996)
Magnetic Resonance in Medicine
, vol.36
, Issue.4
, pp. 562-566
-
-
Ordidge, R.J.1
Wylezinska, M.2
Hugg, J.W.3
Butterworth, E.4
Franconi, F.5
-
16
-
-
0024551355
-
Computer simulation of MRS localization techniques: An analysis of ISIS
-
DOI 10.1002/mrm.1910090302
-
Lawry TJ, Karczmar GS, Weiner MW, Matson GB,. Computer-simulation of MRS localization techniques-an analysis of ISIS. Magn Reson Med 1989; 9: 299-314. (Pubitemid 19088092)
-
(1989)
Magnetic Resonance in Medicine
, vol.9
, Issue.3
, pp. 299-314
-
-
Lawry, T.J.1
Karczmar, G.S.2
Weiner, M.W.3
Matson, G.B.4
-
17
-
-
0033772753
-
Extended ISIS sequences insensitive to T-1 smearing
-
Ljungberg M, Starck G, Vikhoff-Baaz B, Alpsten M, Ekholm S, Forssell-Aronsson E,. Extended ISIS sequences insensitive to T-1 smearing. Magn Reson Med 2000; 44: 546-555.
-
(2000)
Magn Reson Med
, vol.44
, pp. 546-555
-
-
Ljungberg, M.1
Starck, G.2
Vikhoff-Baaz, B.3
Alpsten, M.4
Ekholm, S.5
Forssell-Aronsson, E.6
-
18
-
-
0001271104
-
Uniform sample excitation with surface coils for in vivo spectroscopy by adiabatic rapid half passage
-
Bendall MR, Pegg DT,. Uniform sample excitation with surface coils for in vivo spectroscopy by adiabatic rapid half passage. J Magn Reson 1986; 67: 376-381.
-
(1986)
J Magn Reson
, vol.67
, pp. 376-381
-
-
Bendall, M.R.1
Pegg, D.T.2
-
19
-
-
0028861559
-
Quality Assessment in in-vivo NMR-spectroscopy, part 4. A multicenter trial of test objects and protocols for performance assessment in clinical NMR-spectroscopy
-
Keevil SF, Barbiroli B, Collins DJ, Danielsen ER, Hennig J, Henriksen O, Leach MO, Longo R, Lowry M, Moore C, Moser E, Segebarth C, Bovee WMMJ, Podo F,. Quality Assessment in in-vivo NMR-spectroscopy, part 4. A multicenter trial of test objects and protocols for performance assessment in clinical NMR-spectroscopy. J Magn Reson 1995; 13: 139-157.
-
(1995)
J Magn Reson
, vol.13
, pp. 139-157
-
-
Keevil, S.F.1
Barbiroli, B.2
Collins, D.J.3
Danielsen, E.R.4
Hennig, J.5
Henriksen, O.6
Leach, M.O.7
Longo, R.8
Lowry, M.9
Moore, C.10
Moser, E.11
Segebarth, C.12
Bovee, W.13
Podo, F.14
-
20
-
-
0035665961
-
The performance of volume selection sequences for in vivo NMR spectroscopy: Implications for quantitative MRS
-
DOI 10.1016/S0730-725X(01)00449-0, PII S0730725X01004490
-
Keevil SF, Newbold MC,. The performance of volume selection sequences for in vivo NMR spectroscopy: implications for quantitative MRS. Magn Reson Imaging 2001; 19: 1217-1226. (Pubitemid 34016587)
-
(2001)
Magnetic Resonance Imaging
, vol.19
, Issue.9
, pp. 1217-1226
-
-
Keevil, S.F.1
Newbold, M.C.2
-
21
-
-
0026894503
-
Experimental characterization of the ISIS technique for volume selected NMR-spectroscopy
-
Keevil SF, Porter DA, Smith MA,. Experimental characterization of the ISIS technique for volume selected NMR-spectroscopy. NMR Biomed 1992; 5: 200-208.
-
(1992)
NMR Biomed
, vol.5
, pp. 200-208
-
-
Keevil, S.F.1
Porter, D.A.2
Smith, M.A.3
-
22
-
-
0029367855
-
Signal profile measurements for evaluation of the volume-selection performance of ISIS
-
Ljungberg M, Starck G, ForssellAronsson E, Alpsten M, Ekholm S,. Signal profile measurements for evaluation of the volume-selection performance of ISIS. NMR Biomed 1995; 8: 271-277.
-
(1995)
NMR Biomed
, vol.8
, pp. 271-277
-
-
Ljungberg, M.1
Starck, G.2
Forssellaronsson, E.3
Alpsten, M.4
Ekholm, S.5
-
23
-
-
0031416189
-
Adiabatic pulses
-
DOI 10.1002/(SICI)1099-1492(199712)10:8<423::AID-NBM488>3.0.CO;2-X
-
Tannus A, Garwood M,. Adiabatic pulses. NMR Biomed 1997; 10: 423-434. (Pubitemid 28110737)
-
(1997)
NMR in Biomedicine
, vol.10
, Issue.8
, pp. 423-434
-
-
Tannus, A.1
Garwood, M.2
-
24
-
-
77949486359
-
Spectroscopic imaging with improved gradient modulated constant adiabaticity pulses on high-field clinical scanners
-
Andronesi OC, Ramadan S, Ratai EM, Jennings D, Mountford CE, Sorensen AG,. Spectroscopic imaging with improved gradient modulated constant adiabaticity pulses on high-field clinical scanners. J Magn Reson 2010; 203: 283-293.
-
(2010)
J Magn Reson
, vol.203
, pp. 283-293
-
-
Andronesi, O.C.1
Ramadan, S.2
Ratai, E.M.3
Jennings, D.4
Mountford, C.E.5
Sorensen, A.G.6
-
25
-
-
19944382844
-
Spin-echo MRS in humans at high field: LASER localisation using FOCI pulses
-
DOI 10.1016/j.jmr.2005.03.009, PII S1090780705000959
-
Kinchesh P, Ordidge RJ,. Spin-echo MRS in humans at high field: LASER localisation using FOCI pulses. J Magn Reson 2005; 175: 30-43. (Pubitemid 40753505)
-
(2005)
Journal of Magnetic Resonance
, vol.175
, Issue.1
, pp. 30-43
-
-
Kinchesh, P.1
Ordidge, R.J.2
-
26
-
-
0030716493
-
Implementation and evaluation of frequency offset corrected inversion (FOCI) pulses on a clinical MR system
-
DOI 10.1002/mrm.1910380520
-
Payne GS, Leach MO,. Implementation and evaluation of frequency offset corrected inversion (FOCI) pulses on a clinical MR system. Magn Reson Med 1997; 38: 828-833. (Pubitemid 27467723)
-
(1997)
Magnetic Resonance in Medicine
, vol.38
, Issue.5
, pp. 828-833
-
-
Payne, G.S.1
Leach, M.O.2
-
27
-
-
0025338970
-
3-D FLASH imaging using a single surface coil and a new adiabatic pulse, BIR-4
-
Staewen RS, Johnson AJ, Ross BD, Parrish T, Merkle H, Garwood M,. 3-D flash imaging using a single surface coil and a new adiabatic pulse, BIR-4. Invest Radiol 1990; 25: 559-567. (Pubitemid 20173102)
-
(1990)
Investigative Radiology
, vol.25
, Issue.5
, pp. 559-567
-
-
Staewen, R.C.1
Johnson, A.J.2
Ross, B.D.3
Parrish, T.4
Merkle, H.5
Garwood, M.6
-
28
-
-
0346308381
-
Improved Method for Accurate and Efficient Quantification of MRS Data with Use of Prior Knowledge
-
Vanhamme L, van den Boogaart A, Van Huffel S,. Improved method for accurate and efficient quantification of MRS data with use of prior knowledge. J Magn Reson 1997; 129: 35-43. (Pubitemid 127454051)
-
(1997)
Journal of Magnetic Resonance
, vol.129
, Issue.1
, pp. 35-43
-
-
Vanhamme, L.1
Van Den Boogaart, A.2
Van Huffel, S.3
-
29
-
-
0035665961
-
The performance of volume selection sequences for in vivo NMR spectroscopy: Implications for quantitative MRS
-
DOI 10.1016/S0730-725X(01)00449-0, PII S0730725X01004490
-
Keevil SF, Newbold MC,. The performance of volume selection sequences for in vivo NMR spectroscopy: implications for quantitative MRS. Magn Reson Imaging 2001; 19: 1217-1226. (Pubitemid 34016587)
-
(2001)
Magnetic Resonance Imaging
, vol.19
, Issue.9
, pp. 1217-1226
-
-
Keevil, S.F.1
Newbold, M.C.2
-
30
-
-
0001607711
-
Outer volume suppressed image related in vivo spectroscopy (OSIRIS), a high-sensitivity localization technique
-
Connelly A, Counsell C, Lohman JAB, Ordidge RJ,. Outer volume suppressed image related in vivo spectroscopy (OSIRIS), a high-sensitivity localization technique. J Magn Reson 1988; 78: 519-525.
-
(1988)
J Magn Reson
, vol.78
, pp. 519-525
-
-
Connelly, A.1
Counsell, C.2
Lohman, J.A.B.3
Ordidge, R.J.4
-
31
-
-
0029042012
-
Quantification of signal selection efficiency, extra volume suppression and contamination for ISIS, STEAM and PRESS localized H-1-NMR spectroscopy using an EEC localization test object
-
Yongbi NM, Payne GS, Collins DJ, Leach MO,. Quantification of signal selection efficiency, extra volume suppression and contamination for ISIS, STEAM and PRESS localized H-1-NMR spectroscopy using an EEC localization test object. Phys Med Biol 1995; 40: 1293-1303.
-
(1995)
Phys Med Biol
, vol.40
, pp. 1293-1303
-
-
Yongbi, N.M.1
Payne, G.S.2
Collins, D.J.3
Leach, M.O.4
-
32
-
-
0029267270
-
A new localization method using an adiabatic pulse, BIR-4
-
Degraaf RA, Luo Y, Terpstra M, Merkle H, Garwood M,. A new localization method using an adiabatic pulse, BIR-4. J Magn Reson B 1995; 106: 245-252.
-
(1995)
J Magn Reson B
, vol.106
, pp. 245-252
-
-
Degraaf, R.A.1
Luo, Y.2
Terpstra, M.3
Merkle, H.4
Garwood, M.5
-
33
-
-
0027375575
-
31P MRS
-
DOI 10.1002/mrm.1910300505
-
Buchli R, Boesiger P,. Comparison of methods for the determination of absolute metabolite concentrations in human muscles by P-31 MRS. Magn Reson Med 1993; 30: 552-558. (Pubitemid 23317311)
-
(1993)
Magnetic Resonance in Medicine
, vol.30
, Issue.5
, pp. 552-558
-
-
Buchli, R.1
Boesiger, P.2
-
34
-
-
57049134595
-
IRIS-HSVD algorithm for automatic quantitation of in vivo P-31 MRS
-
Wang X, Lee JH,. IRIS-HSVD algorithm for automatic quantitation of in vivo P-31 MRS. J Magn Reson 2009; 196: 23-32.
-
(2009)
J Magn Reson
, vol.196
, pp. 23-32
-
-
Wang, X.1
Lee, J.H.2
-
35
-
-
0036687942
-
31P-MRS: Measuring the phospholipid resonances at 4 Tesla from small voxels
-
DOI 10.1002/nbm.776
-
Jensen JE, Drost DJ, Menon RS, Williamson PC,. In vivo brain P-31-MRS: measuring the phospholipid resonances at 4 Tesla from small voxels. NMR Biomed 2002; 15: 338-347. (Pubitemid 34960101)
-
(2002)
NMR in Biomedicine
, vol.15
, Issue.5
, pp. 338-347
-
-
Eric Jensen, J.1
Drost, D.J.2
Menon, R.S.3
Williamson, P.C.4
-
36
-
-
70349625824
-
Reproducibility assessment of metabolic variables characterizing muscle energetics in vivo: A P-31-MRS study
-
Layec G, Bringard A, Le Fur Y, Vilmen C, Micallef JP, Perrey S, Cozzone PJ, Bendahan D,. Reproducibility assessment of metabolic variables characterizing muscle energetics in vivo: a P-31-MRS study. Magn Reson Med 2009; 62: 840-854.
-
(2009)
Magn Reson Med
, vol.62
, pp. 840-854
-
-
Layec, G.1
Bringard, A.2
Le Fur, Y.3
Vilmen, C.4
Micallef, J.P.5
Perrey, S.6
Cozzone, P.J.7
Bendahan, D.8
-
37
-
-
34848924909
-
31P MRS: A quantitative review
-
DOI 10.1002/nbm.1192
-
Kemp GJ, Meyerspeer M, Moser E,. Absolute quantification of phosphorus metabolite concentrations in human muscle in vivo by P-31 MRS: a quantitative review. NMR Biomed 2007; 20: 555-565. (Pubitemid 47496897)
-
(2007)
NMR in Biomedicine
, vol.20
, Issue.6
, pp. 555-565
-
-
Kemp, G.J.1
Meyerspeer, M.2
Moser, E.3
|