메뉴 건너뛰기




Volumn 44, Issue 4, 2011, Pages 583-586

Avoiding false-negative nerve conduction study in ulnar neuropathy at the elbow

Author keywords

Distance measure error; False negative nerve conduction study; Ulnar nerve displacement; Ulnar neuropathy; Ultrasonography

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CUBITAL TUNNEL SYNDROME; ECHOGRAPHY; ELECTRODIAGNOSIS; FALSE NEGATIVE RESULT; FEMALE; HUMAN; MALE; MOTOR NERVE CONDUCTION; PRIORITY JOURNAL; ULNAR NERVE; VELOCITY;

EID: 80052910151     PISSN: 0148639X     EISSN: 10974598     Source Type: Journal    
DOI: 10.1002/mus.22131     Document Type: Article
Times cited : (18)

References (22)
  • 1
    • 0033088949 scopus 로고    scopus 로고
    • American Academy of Physical Medicine and Rehabilitation, American Academy of Neurology
    • Practice parameter for electrodiagnostic studies in ulnar neuropathy at the elbow: summary statement. American Association of Electrodiagnostic Medicine
    • Practice parameter for electrodiagnostic studies in ulnar neuropathy at the elbow: summary statement. American Association of Electrodiagnostic Medicine, American Academy of Physical Medicine and Rehabilitation, American Academy of Neurology. Arch Phys Med Rehabil 1999;80:357-359.
    • (1999) Arch Phys Med Rehabil , vol.80 , pp. 357-359
  • 3
    • 0036896139 scopus 로고    scopus 로고
    • Changes in nerve conduction velocity across the elbow due to experimental error
    • Landau ME, Diaz MI, Barner KC, Campbell WW. Changes in nerve conduction velocity across the elbow due to experimental error. Muscle Nerve 2002;26:838-840.
    • (2002) Muscle Nerve , vol.26 , pp. 838-840
    • Landau, M.E.1    Diaz, M.I.2    Barner, K.C.3    Campbell, W.W.4
  • 4
    • 0022657276 scopus 로고
    • The evaluation of suspected ulnar neuropathy at the elbow. Normal conduction study values
    • Kincaid JC, Phillips LH II, Daube JR. The evaluation of suspected ulnar neuropathy at the elbow. Normal conduction study values. Arch Neurol 1986;43:44-47.
    • (1986) Arch Neurol , vol.43 , pp. 44-47
    • Kincaid, J.C.1    Phillips, L.H.2    Daube, J.R.3
  • 5
    • 0028842328 scopus 로고
    • Comparison of the flexed and extended elbow positions in localizing ulnar neuropathy at the elbow
    • Kothari MJ, Preston DC. Comparison of the flexed and extended elbow positions in localizing ulnar neuropathy at the elbow. Muscle Nerve 1995;18:336-340.
    • (1995) Muscle Nerve , vol.18 , pp. 336-340
    • Kothari, M.J.1    Preston, D.C.2
  • 6
    • 16844383388 scopus 로고    scopus 로고
    • Distance measure error induced by displacement of the ulnar nerve when the elbow is flexed
    • Kim BJ, Date ES, Lee SH, Yoon JS, Hur SY, Kim SJ. Distance measure error induced by displacement of the ulnar nerve when the elbow is flexed. Arch Phys Med Rehabil 2005;86:809-812.
    • (2005) Arch Phys Med Rehabil , vol.86 , pp. 809-812
    • Kim, B.J.1    Date, E.S.2    Lee, S.H.3    Yoon, J.S.4    Hur, S.Y.5    Kim, S.J.6
  • 9
    • 0028355914 scopus 로고
    • Sensory and mixed nerve conduction studies in the evaluation of ulnar neuropathy at the elbow
    • Raynor EM, Shefner JM, Preston DC, Logigian EL. Sensory and mixed nerve conduction studies in the evaluation of ulnar neuropathy at the elbow. Muscle Nerve 1994;17:785-792.
    • (1994) Muscle Nerve , vol.17 , pp. 785-792
    • Raynor, E.M.1    Shefner, J.M.2    Preston, D.C.3    Logigian, E.L.4
  • 11
    • 0015383082 scopus 로고
    • Experimental error in determination of nerve conduction velocity
    • Maynard FM, Stolov WC. Experimental error in determination of nerve conduction velocity. Arch Phys Med Rehabil 1972;53: 362-372.
    • (1972) Arch Phys Med Rehabil , vol.53 , pp. 362-372
    • Maynard, F.M.1    Stolov, W.C.2
  • 12
    • 38149044338 scopus 로고    scopus 로고
    • Pearls & Oy-sters: False positives in short-segment nerve conduction studies due to ulnar nerve dislocation
    • Kim BJ, Koh SB, Park KW, Kim SJ, Yoon JS. Pearls & Oy-sters: false positives in short-segment nerve conduction studies due to ulnar nerve dislocation. Neurology 2008;70:e9-13.
    • (2008) Neurology , vol.70
    • Kim, B.J.1    Koh, S.B.2    Park, K.W.3    Kim, S.J.4    Yoon, J.S.5
  • 13
    • 76049099553 scopus 로고    scopus 로고
    • Ulnar neuropathy with normal electrodiagnosis and abnormal nerve ultrasound
    • Yoon JS, Walker FO, Cartwright MS. Ulnar neuropathy with normal electrodiagnosis and abnormal nerve ultrasound. Arch Phys Med Rehabil 2010;91:318-320.
    • (2010) Arch Phys Med Rehabil , vol.91 , pp. 318-320
    • Yoon, J.S.1    Walker, F.O.2    Cartwright, M.S.3
  • 14
    • 77949496542 scopus 로고    scopus 로고
    • Ulnar neuropathy at the elbow: How frequent is the idiopathic form? An ultrasonographic study in a cohort of patients
    • Filippou G, Mondelli M, Greco G, Bertoldi I, Frediani B, Galeazzi M, et al. Ulnar neuropathy at the elbow: how frequent is the idiopathic form? An ultrasonographic study in a cohort of patients. Clin Exp Rheumatol 2010;28:63-67.
    • (2010) Clin Exp Rheumatol , vol.28 , pp. 63-67
    • Filippou, G.1    Mondelli, M.2    Greco, G.3    Bertoldi, I.4    Frediani, B.5    Galeazzi, M.6
  • 15
    • 61849138961 scopus 로고    scopus 로고
    • Use of ultrasonography in ulnar nerve entrapment surgery-a prospective study
    • Kutlay M, Colak A, Simsek H, Ozturk E, Senol MG, Topuz K, et al. Use of ultrasonography in ulnar nerve entrapment surgery-a prospective study. Neurosurg Rev 2009;32:225-232.
    • (2009) Neurosurg Rev , vol.32 , pp. 225-232
    • Kutlay, M.1    Colak, A.2    Simsek, H.3    Ozturk, E.4    Senol, M.G.5    Topuz, K.6
  • 17
    • 0016737146 scopus 로고
    • Recurrent ulnar-nerve dislocation at the elbow
    • Childress HM. Recurrent ulnar-nerve dislocation at the elbow. Clin Orthop Relat Res 1975;108:168-173.
    • (1975) Clin Orthop Relat Res , vol.108 , pp. 168-173
    • Childress, H.M.1
  • 21
    • 53549083797 scopus 로고    scopus 로고
    • Ultrasonographic swelling ratio in the diagnosis of ulnar neuropathy at the elbow
    • Yoon JS, Walker FO, Cartwright MS. Ultrasonographic swelling ratio in the diagnosis of ulnar neuropathy at the elbow. Muscle Nerve 2008;38:1231-1235.
    • (2008) Muscle Nerve , vol.38 , pp. 1231-1235
    • Yoon, J.S.1    Walker, F.O.2    Cartwright, M.S.3
  • 22
    • 70349787351 scopus 로고    scopus 로고
    • Ultrasound evaluation of ulnar neuropathy at the elbow: Correlation with electrophysiological studies
    • Oxf
    • Volpe A, Rossato G, Bottanelli M, Marchetta A, Caramaschi P, Bambara LM, et al. Ultrasound evaluation of ulnar neuropathy at the elbow: correlation with electrophysiological studies. Rheumatology (Oxf) 2009;48:1098-1101.
    • (2009) Rheumatology , vol.48 , pp. 1098-1101
    • Volpe, A.1    Rossato, G.2    Bottanelli, M.3    Marchetta, A.4    Caramaschi, P.5    Bambara, L.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.