-
1
-
-
0033088949
-
American Academy of Physical Medicine and Rehabilitation, American Academy of Neurology
-
Practice parameter for electrodiagnostic studies in ulnar neuropathy at the elbow: summary statement. American Association of Electrodiagnostic Medicine
-
Practice parameter for electrodiagnostic studies in ulnar neuropathy at the elbow: summary statement. American Association of Electrodiagnostic Medicine, American Academy of Physical Medicine and Rehabilitation, American Academy of Neurology. Arch Phys Med Rehabil 1999;80:357-359.
-
(1999)
Arch Phys Med Rehabil
, vol.80
, pp. 357-359
-
-
-
3
-
-
0036896139
-
Changes in nerve conduction velocity across the elbow due to experimental error
-
Landau ME, Diaz MI, Barner KC, Campbell WW. Changes in nerve conduction velocity across the elbow due to experimental error. Muscle Nerve 2002;26:838-840.
-
(2002)
Muscle Nerve
, vol.26
, pp. 838-840
-
-
Landau, M.E.1
Diaz, M.I.2
Barner, K.C.3
Campbell, W.W.4
-
4
-
-
0022657276
-
The evaluation of suspected ulnar neuropathy at the elbow. Normal conduction study values
-
Kincaid JC, Phillips LH II, Daube JR. The evaluation of suspected ulnar neuropathy at the elbow. Normal conduction study values. Arch Neurol 1986;43:44-47.
-
(1986)
Arch Neurol
, vol.43
, pp. 44-47
-
-
Kincaid, J.C.1
Phillips, L.H.2
Daube, J.R.3
-
5
-
-
0028842328
-
Comparison of the flexed and extended elbow positions in localizing ulnar neuropathy at the elbow
-
Kothari MJ, Preston DC. Comparison of the flexed and extended elbow positions in localizing ulnar neuropathy at the elbow. Muscle Nerve 1995;18:336-340.
-
(1995)
Muscle Nerve
, vol.18
, pp. 336-340
-
-
Kothari, M.J.1
Preston, D.C.2
-
6
-
-
16844383388
-
Distance measure error induced by displacement of the ulnar nerve when the elbow is flexed
-
Kim BJ, Date ES, Lee SH, Yoon JS, Hur SY, Kim SJ. Distance measure error induced by displacement of the ulnar nerve when the elbow is flexed. Arch Phys Med Rehabil 2005;86:809-812.
-
(2005)
Arch Phys Med Rehabil
, vol.86
, pp. 809-812
-
-
Kim, B.J.1
Date, E.S.2
Lee, S.H.3
Yoon, J.S.4
Hur, S.Y.5
Kim, S.J.6
-
9
-
-
0028355914
-
Sensory and mixed nerve conduction studies in the evaluation of ulnar neuropathy at the elbow
-
Raynor EM, Shefner JM, Preston DC, Logigian EL. Sensory and mixed nerve conduction studies in the evaluation of ulnar neuropathy at the elbow. Muscle Nerve 1994;17:785-792.
-
(1994)
Muscle Nerve
, vol.17
, pp. 785-792
-
-
Raynor, E.M.1
Shefner, J.M.2
Preston, D.C.3
Logigian, E.L.4
-
10
-
-
3242798142
-
Clinical, electrodiagnostic, and sonographic studies in ulnar neuropathy at the elbow
-
Beekman R, van der Plas JP, Uitdehaag BM, Schellens RL, Visser LH. Clinical, electrodiagnostic, and sonographic studies in ulnar neuropathy at the elbow. Muscle Nerve 2004;30:202-208.
-
(2004)
Muscle Nerve
, vol.30
, pp. 202-208
-
-
Beekman, R.1
van der Plas, J.P.2
Uitdehaag, B.M.3
Schellens, R.L.4
Visser, L.H.5
-
11
-
-
0015383082
-
Experimental error in determination of nerve conduction velocity
-
Maynard FM, Stolov WC. Experimental error in determination of nerve conduction velocity. Arch Phys Med Rehabil 1972;53: 362-372.
-
(1972)
Arch Phys Med Rehabil
, vol.53
, pp. 362-372
-
-
Maynard, F.M.1
Stolov, W.C.2
-
12
-
-
38149044338
-
Pearls & Oy-sters: False positives in short-segment nerve conduction studies due to ulnar nerve dislocation
-
Kim BJ, Koh SB, Park KW, Kim SJ, Yoon JS. Pearls & Oy-sters: false positives in short-segment nerve conduction studies due to ulnar nerve dislocation. Neurology 2008;70:e9-13.
-
(2008)
Neurology
, vol.70
-
-
Kim, B.J.1
Koh, S.B.2
Park, K.W.3
Kim, S.J.4
Yoon, J.S.5
-
13
-
-
76049099553
-
Ulnar neuropathy with normal electrodiagnosis and abnormal nerve ultrasound
-
Yoon JS, Walker FO, Cartwright MS. Ulnar neuropathy with normal electrodiagnosis and abnormal nerve ultrasound. Arch Phys Med Rehabil 2010;91:318-320.
-
(2010)
Arch Phys Med Rehabil
, vol.91
, pp. 318-320
-
-
Yoon, J.S.1
Walker, F.O.2
Cartwright, M.S.3
-
14
-
-
77949496542
-
Ulnar neuropathy at the elbow: How frequent is the idiopathic form? An ultrasonographic study in a cohort of patients
-
Filippou G, Mondelli M, Greco G, Bertoldi I, Frediani B, Galeazzi M, et al. Ulnar neuropathy at the elbow: how frequent is the idiopathic form? An ultrasonographic study in a cohort of patients. Clin Exp Rheumatol 2010;28:63-67.
-
(2010)
Clin Exp Rheumatol
, vol.28
, pp. 63-67
-
-
Filippou, G.1
Mondelli, M.2
Greco, G.3
Bertoldi, I.4
Frediani, B.5
Galeazzi, M.6
-
15
-
-
61849138961
-
Use of ultrasonography in ulnar nerve entrapment surgery-a prospective study
-
Kutlay M, Colak A, Simsek H, Ozturk E, Senol MG, Topuz K, et al. Use of ultrasonography in ulnar nerve entrapment surgery-a prospective study. Neurosurg Rev 2009;32:225-232.
-
(2009)
Neurosurg Rev
, vol.32
, pp. 225-232
-
-
Kutlay, M.1
Colak, A.2
Simsek, H.3
Ozturk, E.4
Senol, M.G.5
Topuz, K.6
-
16
-
-
47149109656
-
Sonographic appearances of the normal ulnar nerve in the cubital tunnel
-
Ozturk E, Sonmez G, Colak A, Sildiroglu HO, Mutlu H, Senol MG, et al. Sonographic appearances of the normal ulnar nerve in the cubital tunnel. J Clin Ultrasound 2008;36:325-329.
-
(2008)
J Clin Ultrasound
, vol.36
, pp. 325-329
-
-
Ozturk, E.1
Sonmez, G.2
Colak, A.3
Sildiroglu, H.O.4
Mutlu, H.5
Senol, M.G.6
-
17
-
-
0016737146
-
Recurrent ulnar-nerve dislocation at the elbow
-
Childress HM. Recurrent ulnar-nerve dislocation at the elbow. Clin Orthop Relat Res 1975;108:168-173.
-
(1975)
Clin Orthop Relat Res
, vol.108
, pp. 168-173
-
-
Childress, H.M.1
-
18
-
-
1542316173
-
Diagnostic value of high-resolution sonography in ulnar neuropathy at the elbow
-
Beekman R, Schoemaker MC, van der Plas JP, van den Berg LH, Franssen H, Wokke JH, et al. Diagnostic value of high-resolution sonography in ulnar neuropathy at the elbow. Neurology 2004;62:767-773.
-
(2004)
Neurology
, vol.62
, pp. 767-773
-
-
Beekman, R.1
Schoemaker, M.C.2
van der Plas, J.P.3
van den Berg, L.H.4
Franssen, H.5
Wokke, J.H.6
-
19
-
-
33747875135
-
Ultrasound in the diagnosis of ulnar neuropathy at the cubital tunnel
-
Wiesler ER, Chloros GD, Cartwright MS, Shin HW, Walker FO. Ultrasound in the diagnosis of ulnar neuropathy at the cubital tunnel. J Hand Surg [Am] 2006;31:1088-1093.
-
(2006)
J Hand Surg [Am]
, vol.31
, pp. 1088-1093
-
-
Wiesler, E.R.1
Chloros, G.D.2
Cartwright, M.S.3
Shin, H.W.4
Walker, F.O.5
-
20
-
-
37049003976
-
Ultrasonographic measurements in cubital tunnel syndrome
-
Yoon JS, Kim BJ, Kim SJ, Kim JM, Sim KH, Hong SJ, et al. Ultrasonographic measurements in cubital tunnel syndrome. Muscle Nerve 2007;36:853-855.
-
(2007)
Muscle Nerve
, vol.36
, pp. 853-855
-
-
Yoon, J.S.1
Kim, B.J.2
Kim, S.J.3
Kim, J.M.4
Sim, K.H.5
Hong, S.J.6
-
21
-
-
53549083797
-
Ultrasonographic swelling ratio in the diagnosis of ulnar neuropathy at the elbow
-
Yoon JS, Walker FO, Cartwright MS. Ultrasonographic swelling ratio in the diagnosis of ulnar neuropathy at the elbow. Muscle Nerve 2008;38:1231-1235.
-
(2008)
Muscle Nerve
, vol.38
, pp. 1231-1235
-
-
Yoon, J.S.1
Walker, F.O.2
Cartwright, M.S.3
-
22
-
-
70349787351
-
Ultrasound evaluation of ulnar neuropathy at the elbow: Correlation with electrophysiological studies
-
Oxf
-
Volpe A, Rossato G, Bottanelli M, Marchetta A, Caramaschi P, Bambara LM, et al. Ultrasound evaluation of ulnar neuropathy at the elbow: correlation with electrophysiological studies. Rheumatology (Oxf) 2009;48:1098-1101.
-
(2009)
Rheumatology
, vol.48
, pp. 1098-1101
-
-
Volpe, A.1
Rossato, G.2
Bottanelli, M.3
Marchetta, A.4
Caramaschi, P.5
Bambara, L.M.6
|