Volumn 86, Issue 4, 2005, Pages 809-812

Distance measure error induced by displacement of the ulnar nerve when the elbow is flexed

Author keywords

Diagnostic errors; Electrodiagnosis; Nerve conduction; Ulnar nerve; Ultrasonography

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; DISLOCATION; ECHOGRAPHY; ELBOW; ELBOW FLEXION; ELECTRODIAGNOSIS; FEMALE; HUMAN; HUMAN EXPERIMENT; MALE; NERVE CONDUCTION; NERVE INJURY; NORMAL HUMAN; SKIN; SUBLUXATION; ULNAR NERVE; UNIVERSITY HOSPITAL; VOLUNTEER;

EID: 16844383388     PISSN: 00039993     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apmr.2004.08.006     Document Type: Article
Times cited : (58)

References (22)
  • 1
    • 0034067562 scopus 로고    scopus 로고
    • Diagnosis of ulnar neuropathy: A new approach
    • K. Merlevede, P. Theys, J. van Hees Diagnosis of ulnar neuropathy a new approach Muscle Nerve 23 2000 478 481
    • (2000) Muscle Nerve , vol.23 , pp. 478-481
    • Merlevede, K.1    Theys, P.2    Van Hees, J.3
  • 2
    • 0037233693 scopus 로고    scopus 로고
    • The utility of segmental nerve conduction studies in ulnar mononeuropathy at the elbow
    • Y. Azrieli, L. Weimer, R. Lovelace, C. Gooch The utility of segmental nerve conduction studies in ulnar mononeuropathy at the elbow Muscle Nerve 27 2003 46 50
    • (2003) Muscle Nerve , vol.27 , pp. 46-50
    • Azrieli, Y.1    Weimer, L.2    Lovelace, R.3    Gooch, C.4
  • 3
    • 0036896139 scopus 로고    scopus 로고
    • Changes in nerve conduction velocity across the elbow due to experimental error
    • M.E. Landau, M.I. Diaz, K.C. Barner, W.W. Campbell Changes in nerve conduction velocity across the elbow due to experimental error Muscle Nerve 26 2002 838 840
    • (2002) Muscle Nerve , vol.26 , pp. 838-840
    • Landau, M.E.1    Diaz, M.I.2    Barner, K.C.3    Campbell, W.W.4
  • 4
    • 0028842328 scopus 로고
    • Comparison of the flexed and extended elbow positions in localizing ulnar neuropathy at the elbow
    • M.J. Kothari, D.C. Preston Comparison of the flexed and extended elbow positions in localizing ulnar neuropathy at the elbow Muscle Nerve 18 1995 336 340
    • (1995) Muscle Nerve , vol.18 , pp. 336-340
    • Kothari, M.J.1    Preston, D.C.2
  • 5
    • 0022657276 scopus 로고
    • The evaluation of suspected ulnar neuropathy at the elbow. Normal conduction study values
    • J.C. Kincaid, L.H. Phillips II, J.R. Daube The evaluation of suspected ulnar neuropathy at the elbow. Normal conduction study values Arch Neurol 43 1986 44 47
    • (1986) Arch Neurol , vol.43 , pp. 44-47
    • Kincaid, J.C.1    Phillips II, L.H.2    Daube, J.R.3
  • 6
    • 0015106619 scopus 로고
    • Ulnar nerve conduction velocity--effect of elbow position on measurement
    • N.S. Checkles, A.D. Russakov, D.L. Piero Ulnar nerve conduction velocity--effect of elbow position on measurement Arch Phys Med Rehabil 52 1971 362 365
    • (1971) Arch Phys Med Rehabil , vol.52 , pp. 362-365
    • Checkles, N.S.1    Russakov, A.D.2    Piero, D.L.3
  • 7
    • 0032110252 scopus 로고    scopus 로고
    • Morphologic changes in the ulnar nerve at the elbow with flexion and extension: A magnetic resonance imaging study with 3-dimensional reconstruction
    • V.V. Patel, F.P. Heidenreich Jr, R.R. Bindra, K. Yamaguchi, R.H. Gelberman Morphologic changes in the ulnar nerve at the elbow with flexion and extension a magnetic resonance imaging study with 3-dimensional reconstruction J Shoulder Elbow Surg 7 1998 368 374
    • (1998) J Shoulder Elbow Surg , vol.7 , pp. 368-374
    • Patel, V.V.1    Heidenreich Jr., F.P.2    Bindra, R.R.3    Yamaguchi, K.4    Gelberman, R.H.5
  • 9
    • 0016737146 scopus 로고
    • Recurrent ulnar-nerve dislocation at the elbow
    • H.M. Childress Recurrent ulnar-nerve dislocation at the elbow Clin Orthop 108 1975 168 173 May
    • (1975) Clin Orthop , Issue.108 , pp. 168-173
    • Childress, H.M.1
  • 10
    • 0034860247 scopus 로고    scopus 로고
    • Ulnar nerve dislocation and snapping triceps syndrome: Diagnosis with dynamic sonography--report of three cases
    • J.A. Jacobson, P.J. Jebson, A.W. Jeffers, D.P. Fessell, C.W. Hayes Ulnar nerve dislocation and snapping triceps syndrome diagnosis with dynamic sonography--report of three cases Radiology 220 2001 601 605
    • (2001) Radiology , vol.220 , pp. 601-605
    • Jacobson, J.A.1    Jebson, P.J.2    Jeffers, A.W.3    Fessell, D.P.4    Hayes, C.W.5
  • 11
    • 0018104984 scopus 로고
    • Recurrent ulnar nerve dislocation at the elbow. Report of a non-traumatic case with ulnar entrapment neuropathy
    • S. Grevsten, U. Lindsjo, S. Olerud Recurrent ulnar nerve dislocation at the elbow. Report of a non-traumatic case with ulnar entrapment neuropathy Acta Orthop Scand 49 1978 151 153
    • (1978) Acta Orthop Scand , vol.49 , pp. 151-153
    • Grevsten, S.1    Lindsjo, U.2    Olerud, S.3
  • 12
    • 0031964673 scopus 로고    scopus 로고
    • Recurrent dislocation of the ulnar nerve in athletes: A report of two cases
    • G. Capasso, V. Testa, S. Cappabianca, N. Maffulli Recurrent dislocation of the ulnar nerve in athletes a report of two cases Clin J Sport Med 8 1998 56 58
    • (1998) Clin J Sport Med , vol.8 , pp. 56-58
    • Capasso, G.1    Testa, V.2    Cappabianca, S.3    Maffulli, N.4
  • 13
    • 0005421910 scopus 로고    scopus 로고
    • Nerve conduction studies
    • D. Dumitru A.A. Amato M.J. Zwarts 2nd ed. Hanley & Belfus Philadelphia
    • D. Dumitru, A.A. Amato, M.J. Zwarts Nerve conduction studies D. Dumitru A.A. Amato M.J. Zwarts Electrodiagnostic medicine 2nd ed. 2002 Hanley & Belfus Philadelphia 196
    • (2002) Electrodiagnostic Medicine , pp. 196
    • Dumitru, D.1    Amato, A.A.2    Zwarts, M.J.3
  • 14
    • 0034020685 scopus 로고    scopus 로고
    • Morphology and dynamics of the ulnar nerve in the cubital tunnel. Observation by ultrasonography
    • M. Okamoto, M. Abe, H. Shirai, N. Ueda Morphology and dynamics of the ulnar nerve in the cubital tunnel. Observation by ultrasonography J Hand Surg 25 2000 85 89 [Br]
    • (2000) J Hand Surg , vol.25 , pp. 85-89
    • Okamoto, M.1    Abe, M.2    Shirai, H.3    Ueda, N.4
  • 15
    • 0000712550 scopus 로고
    • Recurrent ulnar-nerve dislocation at the elbow
    • H.M. Childress Recurrent ulnar-nerve dislocation at the elbow J Bone Joint Surg Am 38 1956 978 984
    • (1956) J Bone Joint Surg Am , vol.38 , pp. 978-984
    • Childress, H.M.1
  • 16
    • 0038509927 scopus 로고    scopus 로고
    • Entrapment neuropathy of the ulnar nerve by a constriction band: The role of MRI
    • R.J. Mobbs, C. Rogan, P. Blum Entrapment neuropathy of the ulnar nerve by a constriction band the role of MRI J Clin Neurosci 10 2003 374 375
    • (2003) J Clin Neurosci , vol.10 , pp. 374-375
    • Mobbs, R.J.1    Rogan, C.2    Blum, P.3
  • 17
    • 0030044885 scopus 로고    scopus 로고
    • Ulnar nerve entrapment at the elbow: Correlation of magnetic resonance imaging, clinical, electrodiagnostic, and intraoperative findings
    • G.W. Britz, D.R. Haynor, C. Kuntz Ulnar nerve entrapment at the elbow correlation of magnetic resonance imaging, clinical, electrodiagnostic, and intraoperative findings Neurosurgery 38 1996 458 465
    • (1996) Neurosurgery , vol.38 , pp. 458-465
    • Britz, G.W.1    Haynor, D.R.2    Kuntz, C.3
  • 18
    • 0032189984 scopus 로고    scopus 로고
    • Cubital tunnel syndrome: Diagnosis by high-resolution ultrasonography
    • H.J. Chiou, Y.H. Chou, S.P. Cheng Cubital tunnel syndrome diagnosis by high-resolution ultrasonography J Ultrasound Med 17 1998 643 648
    • (1998) J Ultrasound Med , vol.17 , pp. 643-648
    • Chiou, H.J.1    Chou, Y.H.2    Cheng, S.P.3
  • 20
    • 0032866157 scopus 로고    scopus 로고
    • Literature review of the usefulness of nerve conduction studies and electromyography in the evaluation of patients with ulnar neuropathy at the elbow
    • W.W. Campbell, D.J. Carroll, M.K. Greenberg Literature review of the usefulness of nerve conduction studies and electromyography in the evaluation of patients with ulnar neuropathy at the elbow Muscle Nerve 22 Suppl 8 1999 S175 S205
    • (1999) Muscle Nerve , vol.22 , Issue.8 SUPPL.
    • Campbell, W.W.1    Carroll, D.J.2    Greenberg, M.K.3
  • 21
    • 0015383082 scopus 로고
    • Experimental error in determination of nerve conduction velocity
    • F.M. Maynard, W.C. Stolov Experimental error in determination of nerve conduction velocity Arch Phys Med Rehabil 53 1972 362 372
    • (1972) Arch Phys Med Rehabil , vol.53 , pp. 362-372
    • Maynard, F.M.1    Stolov, W.C.2
  • 22
    • 0036019012 scopus 로고    scopus 로고
    • Intramuscular neurolysis with alcohol to treat post-stroke finger flexor spasticity
    • K.H. Kong, K.S. Chua Intramuscular neurolysis with alcohol to treat post-stroke finger flexor spasticity Clin Rehabil 16 2002 378 381
    • (2002) Clin Rehabil , vol.16 , pp. 378-381
    • Kong, K.H.1    Chua, K.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.