메뉴 건너뛰기




Volumn 60, Issue 10, 2011, Pages 3259-3268

Surface electromyographic signals using dry electrodes

Author keywords

Electrodes; electromyography (EMG); myoelectric signal; noise; skin preparation

Indexed keywords

AG/AGCL; DRY ELECTRODE; ELECTROMYOGRAPHIC SIGNAL; EMG MEASUREMENT; FRAUNHOFER; ISOMETRIC CONTRACTIONS; ISOPROPYL ALCOHOLS; MUSCLE CONTRACTIONS; MYOELECTRIC SIGNALS; NOISE; POSITIVE EFFECTS; PRACTICAL IMPLEMENTATION; PREPARATION METHOD; RECORDING SYSTEMS; SIGNAL FEATURES; SURFACE EMG; TIBIALIS ANTERIOR;

EID: 80052831337     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIM.2011.2164279     Document Type: Conference Paper
Times cited : (100)

References (21)
  • 1
    • 0033865959 scopus 로고    scopus 로고
    • Clinical utility of surface EMG: Report of the therapeutics and technology assessment subcommittee of the American Academy of Neurology
    • Jul.
    • S. L. Pullman, D. S. Goodin, A. I. Marquinez, S. Tabbal, and M. Rubin, "Clinical utility of surface EMG: Report of the therapeutics and technology assessment subcommittee of the American Academy of Neurology," Neurology, vol. 55, no. 2, pp. 171-177, Jul. 2000.
    • (2000) Neurology , vol.55 , Issue.2 , pp. 171-177
    • Pullman, S.L.1    Goodin, D.S.2    Marquinez, A.I.3    Tabbal, S.4    Rubin, M.5
  • 2
    • 7544222470 scopus 로고    scopus 로고
    • Grasp recognition from myoelectric signals
    • Auckland, New Zealand
    • S. Ferguson and G. R. Dunlop, "Grasp recognition from myoelectric signals," in Proc. Australas. Conf. Robot. Autom., Auckland, New Zealand, 2002, pp. 83-87.
    • (2002) Proc. Australas. Conf. Robot. Autom. , pp. 83-87
    • Ferguson, S.1    Dunlop, G.R.2
  • 3
    • 0031037416 scopus 로고    scopus 로고
    • Effects of muscle kinematics on surface EMG amplitude and frequency during fatiguing dynamic contractions
    • Jan.
    • J. R. Potvin, "Effects of muscle kinematics on surface EMG amplitude and frequency during fatiguing dynamic contractions," J. Appl. Physiol., vol. 82, no. 1, pp. 144-151, Jan. 1997.
    • (1997) J. Appl. Physiol. , vol.82 , Issue.1 , pp. 144-151
    • Potvin, J.R.1
  • 4
    • 77957835684 scopus 로고    scopus 로고
    • Flexible dry electrode for recording surface electromyogram
    • Austin, TX
    • A. D. C. Chan and E. Lemaire, "Flexible dry electrode for recording surface electromyogram," in Proc. IEEE Int. Instrum. Meas. Technol. Conf., Austin, TX, 2010, pp. 1234-1237.
    • (2010) Proc. IEEE Int. Instrum. Meas. Technol. Conf. , pp. 1234-1237
    • Chan, A.D.C.1    Lemaire, E.2
  • 5
    • 41549116003 scopus 로고    scopus 로고
    • Flexible polymeric dry electrodes for the long-term monitoring of ECG
    • May
    • J. Y. Baek, J. H. An, J. M. Choi, K. S. Park, and S. H. Lee, "Flexible polymeric dry electrodes for the long-term monitoring of ECG," Sens. Actuators A, Phys., vol. 143, no. 2, pp. 423-429, May 2008.
    • (2008) Sens. Actuators A, Phys. , vol.143 , Issue.2 , pp. 423-429
    • Baek, J.Y.1    An, J.H.2    Choi, J.M.3    Park, K.S.4    Lee, S.H.5
  • 7
    • 0034048104 scopus 로고    scopus 로고
    • A direct comparison of wet, dry and insulating bioelectric recording electrodes
    • May
    • A. Searle and L. Kirkup, "A direct comparison of wet, dry and insulating bioelectric recording electrodes," Physiol. Meas., vol. 21, no. 2, pp. 271-283, May 2000.
    • (2000) Physiol. Meas. , vol.21 , Issue.2 , pp. 271-283
    • Searle, A.1    Kirkup, L.2
  • 9
    • 0021645224 scopus 로고
    • Reducing motion artifacts and interference in biopotential recording
    • Dec.
    • J. G. Webster, "Reducing motion artifacts and interference in biopotential recording," IEEE Trans. Biomed. Eng., vol. BME-31, no. 12, pp. 823-826, Dec. 1984.
    • (1984) IEEE Trans. Biomed. Eng. , vol.BME-31 , Issue.12 , pp. 823-826
    • Webster, J.G.1
  • 10
    • 0017368294 scopus 로고
    • Minimizing electrode motion artifact by skin abrasion
    • Mar.
    • H. W. Tam and J. G. Webster, "Minimizing electrode motion artifact by skin abrasion," IEEE Trans. Biomed. Eng., vol. BME-24, no. 2, pp. 134-139, Mar. 1977.
    • (1977) IEEE Trans. Biomed. Eng. , vol.BME-24 , Issue.2 , pp. 134-139
    • Tam, H.W.1    Webster, J.G.2
  • 11
    • 57649180485 scopus 로고    scopus 로고
    • Flexible dry surface-electrodes for ECG long-term monitoring
    • K.-P. Hoffman and R. Ruff, "Flexible dry surface-electrodes for ECG long-term monitoring," in Proc. Int. Conf. Eng. Med. Biol. Soc., 2007, pp. 5739-5742.
    • (2007) Proc. Int. Conf. Eng. Med. Biol. Soc. , pp. 5739-5742
    • K.-P. Hoffman1    Ruff, R.2
  • 14
    • 0026943629 scopus 로고
    • The spatial integration effect of surface electrode detecting myoelectric signal
    • Nov.
    • J. N. Helal and P. Bouissou, "The spatial integration effect of surface electrode detecting myoelectric signal," IEEE Trans. Biomed. Eng., vol. 39, no. 11, pp. 1161-1167, Nov. 1992.
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , Issue.11 , pp. 1161-1167
    • Helal, J.N.1    Bouissou, P.2
  • 15
    • 80052836402 scopus 로고    scopus 로고
    • Determination of sensor location, Surface Electromyography for the Non-Invasive Assessment of Muscles, [Accessed: Jul. 7], [Online]. Available
    • Determination of sensor location, Surface Electromyography for the Non-Invasive Assessment of Muscles, [Accessed: Jul. 7, 2010]. [Online]. Available: http://www.seniam.org/
    • (2010)
  • 16
    • 0026444309 scopus 로고
    • Detection of motor unit action potentials with surface electrodes: Influence of electrode size and spacing
    • A. J. Fuglevand, D. A. Winter, A. E. Patla, and D. Stashuk, "Detection of motor unit action potentials with surface electrodes: Influence of electrode size and spacing," Biol. Cybern., vol. 67, no. 2, pp. 143-153, 1992.
    • (1992) Biol. Cybern. , vol.67 , Issue.2 , pp. 143-153
    • Fuglevand, A.J.1    Winter, D.A.2    Patla, A.E.3    Stashuk, D.4
  • 17
    • 80052835872 scopus 로고    scopus 로고
    • Comparison of ECG signal quality between novel dry electrode and a standard gel electrode
    • K. E. Sparks and A. T. Rood, "Comparison of ECG signal quality between novel dry electrode and a standard gel electrode," Med. Sci. Sports Exercise, vol. 38, no. 1, p. S5, 2006.
    • (2006) Med. Sci. Sports Exercise , vol.38 , Issue.1
    • Sparks, K.E.1    Rood, A.T.2
  • 18
    • 57649238737 scopus 로고    scopus 로고
    • Tibialis anterior EMG activation pattern changes with walking speed during over ground and treadmill walking
    • A. Barrett, A. E. Donnelly, and G. Olaighin, "Tibialis anterior EMG activation pattern changes with walking speed during over ground and treadmill walking," in Proc. Conf. IEEE Eng. Med. Biol. Soc., 2007, pp. 4883-4886.
    • (2007) Proc. Conf. IEEE Eng. Med. Biol. Soc. , pp. 4883-4886
    • Barrett, A.1    Donnelly, A.E.2    Olaighin, G.3
  • 19
    • 0015588581 scopus 로고
    • Temporal changes in electrode impedance while recording the electrocardiogram with dry electrode
    • Mar.
    • L. A. Geddes and M. E. Valentinuzzi, "Temporal changes in electrode impedance while recording the electrocardiogram with dry electrode," Ann. Biomed. Eng., vol. 1, no. 3, pp. 356-367, Mar. 1973.
    • (1973) Ann. Biomed. Eng. , vol.1 , Issue.3 , pp. 356-367
    • Geddes, L.A.1    Valentinuzzi, M.E.2
  • 20
    • 11144283609 scopus 로고    scopus 로고
    • Dry electrodes for monitoring of vital signs in functional textiles
    • San Francisco, CA, Sep. 1-5
    • J. Mühlsteff and O. Such, "Dry electrodes for monitoring of vital signs in functional textiles," in Proc. 26th Annu. Int. Conf. IEEE EMBS, San Francisco, CA, Sep. 1-5, 2004, pp. 2212-2215.
    • (2004) Proc. 26th Annu. Int. Conf. IEEE EMBS , pp. 2212-2215
    • Mühlsteff, J.1    Such, O.2
  • 21
    • 0034205642 scopus 로고    scopus 로고
    • A comprehensive model for power line interference in biopotential measurements
    • Jun.
    • M. Chimene and R. Pallas-Areny, "A comprehensive model for power line interference in biopotential measurements," IEEE Trans. Instrum. Meas., vol. 49, no. 3, pp. 535-540, Jun. 2000.
    • (2000) IEEE Trans. Instrum. Meas. , vol.49 , Issue.3 , pp. 535-540
    • Chimene, M.1    Pallas-Areny, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.