메뉴 건너뛰기




Volumn , Issue , 2010, Pages 77-80

Surface electromyographic signals using a dry electrode

Author keywords

Electrodes; Electromyography; Myoelectric signal; Noise; Skin preparation

Indexed keywords

AG/AGCL; DRY ELECTRODE; ELECTROMYOGRAPHIC SIGNAL; ISOPROPYL ALCOHOLS; MOBILITY MONITORING SYSTEMS; MUSCLE CONTRACTIONS; MYOELECTRIC SIGNAL; MYOELECTRIC SIGNALS; NOISE; NOISE LEVELS; PRACTICAL IMPLEMENTATION; SIGNAL STRENGTHS; TIBIALIS ANTERIOR;

EID: 77954396713     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MEMEA.2010.5480213     Document Type: Conference Paper
Times cited : (11)

References (12)
  • 1
    • 41549116003 scopus 로고    scopus 로고
    • Flexible polymeric dry electrodes for the long-term monitoring of ECG
    • J. Y. Baek, J. H. An, J. M. Choi, K. S. Park, S. H. Lee, "Flexible polymeric dry electrodes for the long-term monitoring of ECG," Sensors and Actuators A, 143 pp. 423-429, 2008.
    • (2008) Sensors and Actuators A , vol.143 , pp. 423-429
    • Baek, J.Y.1    An, J.H.2    Choi, J.M.3    Park, K.S.4    Lee, S.H.5
  • 4
    • 0021645224 scopus 로고
    • Reducing motion artifacts and interference in biopotential recording
    • J. G. Webster, "Reducing motion artifacts and interference in biopotential recording," IEEE Trans. Biomed. Eng., vol. BME-31, pp. 823-826,1984.
    • (1984) IEEE Trans. Biomed. Eng. , vol.BME-31 , pp. 823-826
    • Webster, J.G.1
  • 5
    • 0017368294 scopus 로고
    • Minimizing electrode motion artifact by skin abrasion
    • H.W. Tam, J. G. Webster, "Minimizing electrode motion artifact by skin abrasion", IEEE Trans Biomed Eng 24:134-139, 1977
    • (1977) IEEE Trans Biomed Eng , vol.24 , pp. 134-139
    • Tam, H.W.1    Webster, J.G.2
  • 6
    • 57649180485 scopus 로고    scopus 로고
    • Flexible dry surface-electrodes for ECG long-term monitoring
    • K.-P. Hoffman, R. Ruff, "Flexible dry surface-electrodes for ECG long-term monitoring," Proc. Intl Conf. Eng. Med. Biol. Soc., pp. 5739-5742, 2007.
    • (2007) Proc. Intl Conf. Eng. Med. Biol. Soc. , pp. 5739-5742
    • Hoffman, K.-P.1    Ruff, R.2
  • 9
    • 0035372611 scopus 로고    scopus 로고
    • Onset detection in surface electromyographic signals: A systematic comparison of methods
    • G. Staude, C. Flachenecker, M. Daumer, and W. Wolf, "Onset detection in surface electromyographic signals: A systematic comparison of methods," Journal of Applied Signal Processing, 2, 67-81, 2001.
    • (2001) Journal of Applied Signal Processing , vol.2 , pp. 67-81
    • Staude, G.1    Flachenecker, C.2    Daumer, M.3    Wolf, W.4
  • 10
    • 0026943629 scopus 로고
    • The spatial integration effect of surface electrode detecting myoelectric signal
    • Nov.
    • J. N. Helal and P. Bouissou, "The spatial integration effect of surface electrode detecting myoelectric signal," IEEE Trans. Biomed. Eng., vol. 39, pp. 1161-7, Nov. 1992.
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , pp. 1161-1167
    • Helal, J.N.1    Bouissou, P.2
  • 11
    • 0026444309 scopus 로고
    • Detection of motor unit action potentials with surface electrodes: Influence of electrode size and spacing
    • A. J. Fuglevand, D.A. Winter, A.E. Patla, D. Stashuk, "Detection of motor unit action potentials with surface electrodes: influence of electrode size and spacing," Biol. Cybern. 67: 143-153, 1992.
    • (1992) Biol. Cybern. , vol.67 , pp. 143-153
    • Fuglevand, A.J.1    Winter, D.A.2    Patla, A.E.3    Stashuk, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.