메뉴 건너뛰기




Volumn 47, Issue 1, 2012, Pages 89-99

A personal air distribution system with air terminals embedded in chair armrests on commercial airplanes

Author keywords

Air quality; Aircraft cabin; CFD; Displacement ventilation; Experiment; Personal ventilation

Indexed keywords

AIR DISTRIBUTION SYSTEMS; AIR SUPPLY; AIR SYSTEMS; AIRCRAFT CABIN; BASIC PARAMETERS; BREATHING ZONES; COMMERCIAL AIRPLANE; COMPUTATIONAL FLUID DYNAMICS MODELING; COOL AIR; DISPLACEMENT VENTILATION; EXPERIMENTAL TEST; TERMINAL DEVICES; VERTICAL TEMPERATURE;

EID: 80052812412     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2011.04.035     Document Type: Article
Times cited : (86)

References (29)
  • 1
    • 51449117862 scopus 로고    scopus 로고
    • Experimental and numerical investigation of airflow and contaminant transport in an airliner cabin mockup
    • Zhang Z., Chen X., Mazumdar S., Zhang T., Chen Q. Experimental and numerical investigation of airflow and contaminant transport in an airliner cabin mockup. Building and Environment 2009, 44(1):85-94.
    • (2009) Building and Environment , vol.44 , Issue.1 , pp. 85-94
    • Zhang, Z.1    Chen, X.2    Mazumdar, S.3    Zhang, T.4    Chen, Q.5
  • 2
    • 58749106596 scopus 로고    scopus 로고
    • Experimental parametric study of forced and mixed convection in a passenger aircraft cabin mock-up
    • Kühn M., Bosbach J., Wagner C. Experimental parametric study of forced and mixed convection in a passenger aircraft cabin mock-up. Building and Environment 2009, 44(5):961-970.
    • (2009) Building and Environment , vol.44 , Issue.5 , pp. 961-970
    • Kühn, M.1    Bosbach, J.2    Wagner, C.3
  • 3
    • 35448946026 scopus 로고    scopus 로고
    • Experimental study of ventilation effectiveness and air velocity distribution in an aircraft cabin
    • Wang A., Zhang Y., Sun Y., Wang X. Experimental study of ventilation effectiveness and air velocity distribution in an aircraft cabin. Building and Environment 2008, 43(3):337-343.
    • (2008) Building and Environment , vol.43 , Issue.3 , pp. 337-343
    • Wang, A.1    Zhang, Y.2    Sun, Y.3    Wang, X.4
  • 4
    • 33749386199 scopus 로고    scopus 로고
    • Comparison of large eddy simulation predictions with particle image velocimetry data for the airflow in a generic cabin model
    • Lin C.H., Wu T.T., Horstman R.H., Lebbin P.A., Hosni M.H., Jones B.W., et al. Comparison of large eddy simulation predictions with particle image velocimetry data for the airflow in a generic cabin model. HVAC&R Research 2006, 12(3c):935-951.
    • (2006) HVAC&R Research , vol.12 , Issue.3 C , pp. 935-951
    • Lin, C.H.1    Wu, T.T.2    Horstman, R.H.3    Lebbin, P.A.4    Hosni, M.H.5    Jones, B.W.6
  • 5
    • 1642516205 scopus 로고    scopus 로고
    • CFD validation for contaminant transport in aircraft cabin ventilation flow fields. In: Proceedings of Annual SAFE Symposium.
    • Garner R, Wong K, Ericson S. CFD validation for contaminant transport in aircraft cabin ventilation flow fields. In: Proceedings of Annual SAFE Symposium 2003. p.248-253.
    • (2003) , pp. 248-253
    • Garner, R.1    Wong, K.2    Ericson, S.3
  • 6
    • 17144445380 scopus 로고    scopus 로고
    • Application of particle image velocimetry for the measurement of the airflow characteristics in an aircraft cabin
    • Mo H., Hosni M., Jones B. Application of particle image velocimetry for the measurement of the airflow characteristics in an aircraft cabin. ASHRAE Transactions 2003, 109(2):101-110.
    • (2003) ASHRAE Transactions , vol.109 , Issue.2 , pp. 101-110
    • Mo, H.1    Hosni, M.2    Jones, B.3
  • 7
    • 0035458374 scopus 로고    scopus 로고
    • Low relative humidity and aircraft cabin air quality
    • Nagda N.L., Hodgson M. Low relative humidity and aircraft cabin air quality. Indoor Air 2001, 11:200-214.
    • (2001) Indoor Air , vol.11 , pp. 200-214
    • Nagda, N.L.1    Hodgson, M.2
  • 8
    • 1642300823 scopus 로고    scopus 로고
    • Air quality in aircraft. Proceedings of the institution of mechanical engineers, part E
    • Spengler J., Wilson D. Air quality in aircraft. Proceedings of the institution of mechanical engineers, part E. Journal of Process Mechanical Engineering 2003, 217(4):323-336.
    • (2003) Journal of Process Mechanical Engineering , vol.217 , Issue.4 , pp. 323-336
    • Spengler, J.1    Wilson, D.2
  • 10
    • 20444432801 scopus 로고    scopus 로고
    • Health and perception of cabin air quality among Swedish commercial airline crew
    • Lindgren T., Norbäck D. Health and perception of cabin air quality among Swedish commercial airline crew. Indoor Air 2005, 15(Suppl. 10):65-72.
    • (2005) Indoor Air , vol.15 , Issue.SUPPL. 10 , pp. 65-72
    • Lindgren, T.1    Norbäck, D.2
  • 11
    • 13844286024 scopus 로고    scopus 로고
    • Respiratory infections during air travel
    • Leder K., Newman D. Respiratory infections during air travel. Internal Medicine Journal 2005, 35:50-55.
    • (2005) Internal Medicine Journal , vol.35 , pp. 50-55
    • Leder, K.1    Newman, D.2
  • 12
    • 15844385304 scopus 로고    scopus 로고
    • Transmission of infectious diseases during commercial air travel
    • Mangili A., Gendreav M.A. Transmission of infectious diseases during commercial air travel. Lancet 2005, 365:989-996.
    • (2005) Lancet , vol.365 , pp. 989-996
    • Mangili, A.1    Gendreav, M.A.2
  • 13
    • 33751510968 scopus 로고    scopus 로고
    • Novel air distribution systems for commercial aircraft cabins
    • Zhang T., Chen Q. Novel air distribution systems for commercial aircraft cabins. Building and Environment 2007, 42(4):1675-1684.
    • (2007) Building and Environment , vol.42 , Issue.4 , pp. 1675-1684
    • Zhang, T.1    Chen, Q.2
  • 14
    • 71649101412 scopus 로고    scopus 로고
    • An under-aisle air distribution system facilitating humidification of commercial aircraft cabins
    • Zhang T., Yin S., Wang S. An under-aisle air distribution system facilitating humidification of commercial aircraft cabins. Building and Environment 2010, 45(4):907-915.
    • (2010) Building and Environment , vol.45 , Issue.4 , pp. 907-915
    • Zhang, T.1    Yin, S.2    Wang, S.3
  • 15
    • 71649113667 scopus 로고    scopus 로고
    • Numerical study of different air distribution systems for aircraft cabins
    • Copenhagen, Denmark, ID: 922
    • Schmidt M., Muller D., Markwart M. Numerical study of different air distribution systems for aircraft cabins. Proceedings of indoor air 2008, Copenhagen, Denmark, ID: 922.
    • (2008) Proceedings of indoor air
    • Schmidt, M.1    Muller, D.2    Markwart, M.3
  • 16
    • 20844447341 scopus 로고    scopus 로고
    • Personalized ventilation
    • Melikov A.K. Personalized ventilation. Indoor Air 2004, 14(Suppl. 7):157-167.
    • (2004) Indoor Air , vol.14 , Issue.SUPPL. 7 , pp. 157-167
    • Melikov, A.K.1
  • 17
    • 21644475946 scopus 로고    scopus 로고
    • Study on inhalation region by means of CFD analysis and experiment
    • Zhu S., Kato S., Murakami S., Hayashi T. Study on inhalation region by means of CFD analysis and experiment. Building and Environment 2005, 40:1329-1336.
    • (2005) Building and Environment , vol.40 , pp. 1329-1336
    • Zhu, S.1    Kato, S.2    Murakami, S.3    Hayashi, T.4
  • 18
    • 77954216971 scopus 로고    scopus 로고
    • Novel personalized and humidified air supply for airliner passengers
    • Zítek P., Vyhlídal T., Simeunović G. Novel personalized and humidified air supply for airliner passengers. Building and Environment 2010, 45(11):2345-2353.
    • (2010) Building and Environment , vol.45 , Issue.11 , pp. 2345-2353
    • Zítek, P.1    Vyhlídal, T.2    Simeunović, G.3
  • 19
    • 42949084186 scopus 로고    scopus 로고
    • Personalized ventilation for commercial aircraft cabins
    • Gao N.P., Niu J.L. Personalized ventilation for commercial aircraft cabins. Journal of Aircraft 2008, 45(2):508-512.
    • (2008) Journal of Aircraft , vol.45 , Issue.2 , pp. 508-512
    • Gao, N.P.1    Niu, J.L.2
  • 21
    • 77952584938 scopus 로고    scopus 로고
    • Mitigation of cross-contamination in an aircraft cabin via localized exhaust
    • Dygert R.K., Dang T.Q. Mitigation of cross-contamination in an aircraft cabin via localized exhaust. Building and Environment 2010, 45(9):2015-2026.
    • (2010) Building and Environment , vol.45 , Issue.9 , pp. 2015-2026
    • Dygert, R.K.1    Dang, T.Q.2
  • 22
    • 77950314382 scopus 로고    scopus 로고
    • Control of the free convective flow around the human body for enhanced inhaled air quality: application to a seat-incorporated personalized ventilation unit
    • Bolashikov Z., Melikov A., Krenek M. Control of the free convective flow around the human body for enhanced inhaled air quality: application to a seat-incorporated personalized ventilation unit. HVAC&R Research 2010, 16(2):161-188.
    • (2010) HVAC&R Research , vol.16 , Issue.2 , pp. 161-188
    • Bolashikov, Z.1    Melikov, A.2    Krenek, M.3
  • 23
    • 79956369514 scopus 로고    scopus 로고
    • Two simplified manikins for indoor environment assessment
    • Bushan, Korea
    • Zhang T., You P., Sun F., Wang Z. Two simplified manikins for indoor environment assessment. Proceedings of room vent 2009, 1285-1292. Bushan, Korea.
    • (2009) Proceedings of room vent , pp. 1285-1292
    • Zhang, T.1    You, P.2    Sun, F.3    Wang, Z.4
  • 24
    • 0026804722 scopus 로고
    • Development of turbulence models for shear flows by a double expansion technique
    • Yakhot V., Orzag S., Thangam S., Gatski T. Development of turbulence models for shear flows by a double expansion technique. Physics of Fluids Part A 1992, 4(7):1510-1520.
    • (1992) Physics of Fluids Part A , vol.4 , Issue.7 , pp. 1510-1520
    • Yakhot, V.1    Orzag, S.2    Thangam, S.3    Gatski, T.4
  • 25
    • 0029390545 scopus 로고
    • Comparison of different k-e{open} models for indoor air flow computations
    • Chen Q. Comparison of different k-e{open} models for indoor air flow computations. Numerical Heat Transfer Part B 1995, 28:353-369.
    • (1995) Numerical Heat Transfer Part B , vol.28 , pp. 353-369
    • Chen, Q.1
  • 26
    • 36549011775 scopus 로고    scopus 로고
    • Evaluation of various turbulence models in predicting airflow and turbulence in enclosed environments by CFD: part-2: comparison with experimental data from literature
    • Zhang Z., Zhang W., Zhai Z., Chen Q. Evaluation of various turbulence models in predicting airflow and turbulence in enclosed environments by CFD: part-2: comparison with experimental data from literature. HVAC&R Research 2007, 13(6):871-886.
    • (2007) HVAC&R Research , vol.13 , Issue.6 , pp. 871-886
    • Zhang, Z.1    Zhang, W.2    Zhai, Z.3    Chen, Q.4
  • 27
    • 0003842308 scopus 로고    scopus 로고
    • ASHRAE, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta
    • ASHRAE handbook fundamentals 2009, ASHRAE, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta.
    • (2009) ASHRAE handbook fundamentals
  • 28
    • 61749085922 scopus 로고    scopus 로고
    • Computational analysis of reduced-mixing personal ventilation jets
    • Russo J., Dang T., Khalifa H. Computational analysis of reduced-mixing personal ventilation jets. Building and Environment 2009, 44(8):1559-1567.
    • (2009) Building and Environment , vol.44 , Issue.8 , pp. 1559-1567
    • Russo, J.1    Dang, T.2    Khalifa, H.3
  • 29
    • 1642392151 scopus 로고    scopus 로고
    • Measurements of indoor air quality on commercial transport aircraft
    • Monterey, CA, USA
    • Waters M., Bloom T., Grajewski B. Measurements of indoor air quality on commercial transport aircraft. Proceedings of indoor air 2002, 782-787. Monterey, CA, USA.
    • (2002) Proceedings of indoor air , pp. 782-787
    • Waters, M.1    Bloom, T.2    Grajewski, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.