메뉴 건너뛰기




Volumn 43, Issue 3, 2008, Pages 337-343

Experimental study of ventilation effectiveness and air velocity distribution in an aircraft cabin mockup

Author keywords

Aircraft cabin; Airflow; Indoor air quality; Local mean age of air; Ventilation effectiveness factor

Indexed keywords

AIR QUALITY; AIRCRAFT MOCKUPS; CABINS (AIRCRAFT); CARBON DIOXIDE; FLOW OF GASES; FLOW PATTERNS; VELOCITY DISTRIBUTION; VELOCITY MEASUREMENT;

EID: 35448946026     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2006.02.024     Document Type: Article
Times cited : (90)

References (16)
  • 1
    • 0037166987 scopus 로고    scopus 로고
    • Aircraft cabin air recirculation and symptoms of the common cold
    • Zitter J.N., Mazonson P.D., Miller D.P., Hulley S.B., and Balmes J.R. Aircraft cabin air recirculation and symptoms of the common cold. JAMA 288 4 (2002) 483-486
    • (2002) JAMA , vol.288 , Issue.4 , pp. 483-486
    • Zitter, J.N.1    Mazonson, P.D.2    Miller, D.P.3    Hulley, S.B.4    Balmes, J.R.5
  • 5
    • 17144445380 scopus 로고    scopus 로고
    • Application of particle image velocimetry for the measurement of the airflow characteristics in an aircraft cabin
    • Mo H., Hosni M.H., and Jones B.W. Application of particle image velocimetry for the measurement of the airflow characteristics in an aircraft cabin. ASHRAE Transactions 109 1 (2003) 101-109
    • (2003) ASHRAE Transactions , vol.109 , Issue.1 , pp. 101-109
    • Mo, H.1    Hosni, M.H.2    Jones, B.W.3
  • 6
    • 27644482306 scopus 로고    scopus 로고
    • Numerical simulation of airflow and airborne pathogen transport in aircraft cabins. Part 1: numerical simulation of the flow field
    • Lin C., Horstman R., Ahlers M., Sedgwick L., Dunn K., Topmiller J., et al. Numerical simulation of airflow and airborne pathogen transport in aircraft cabins. Part 1: numerical simulation of the flow field. ASHRAE Transactions 111 1 (2005) 755-763
    • (2005) ASHRAE Transactions , vol.111 , Issue.1 , pp. 755-763
    • Lin, C.1    Horstman, R.2    Ahlers, M.3    Sedgwick, L.4    Dunn, K.5    Topmiller, J.6
  • 7
    • 27644457341 scopus 로고    scopus 로고
    • Numerical simulation of airflow and airborne pathogen transport in aircraft cabins. Part 2: numerical simulation of airborne pathogen transport
    • Lin C., Horstman R., Ahlers M., Sedgwick L., Dunn K., Topmiller J., et al. Numerical simulation of airflow and airborne pathogen transport in aircraft cabins. Part 2: numerical simulation of airborne pathogen transport. ASHRAE Transactions 111 1 (2005) 764-768
    • (2005) ASHRAE Transactions , vol.111 , Issue.1 , pp. 764-768
    • Lin, C.1    Horstman, R.2    Ahlers, M.3    Sedgwick, L.4    Dunn, K.5    Topmiller, J.6
  • 8
    • 0019682545 scopus 로고
    • What is ventilation efficiency?
    • Sandberg M. What is ventilation efficiency?. Building and Environment 16 2 (1981) 123-135
    • (1981) Building and Environment , vol.16 , Issue.2 , pp. 123-135
    • Sandberg, M.1
  • 9
    • 0020940765 scopus 로고
    • The use of moments for assessing air quality
    • Sandberg M., and Sjoberg M. The use of moments for assessing air quality. Building and Environment 18 (1983) 181-197
    • (1983) Building and Environment , vol.18 , pp. 181-197
    • Sandberg, M.1    Sjoberg, M.2
  • 10
    • 20344404743 scopus 로고    scopus 로고
    • Effect of ventilation system on particle spatial distribution in ventilated rooms
    • Wang X., Zhang Y., Funk T.L., Zhao L., and Riskowski G.L. Effect of ventilation system on particle spatial distribution in ventilated rooms. ASHRAE Transactions 110 2 (2004) 258-266
    • (2004) ASHRAE Transactions , vol.110 , Issue.2 , pp. 258-266
    • Wang, X.1    Zhang, Y.2    Funk, T.L.3    Zhao, L.4    Riskowski, G.L.5
  • 12
    • 29144535303 scopus 로고    scopus 로고
    • Experimental characterization of airflows in aircraft cabins. Part I: experimental system and measurement
    • Sun Y., Zhang Y., Wang A., Topmiller J.L., and Bennett J. Experimental characterization of airflows in aircraft cabins. Part I: experimental system and measurement. ASHRAE Transactions 111 2 (2005) 45-52
    • (2005) ASHRAE Transactions , vol.111 , Issue.2 , pp. 45-52
    • Sun, Y.1    Zhang, Y.2    Wang, A.3    Topmiller, J.L.4    Bennett, J.5
  • 13
    • 29144532964 scopus 로고    scopus 로고
    • Streak recognition for a 3-D volumetric particle tracking velocimetry system
    • Wang A., Zhang Y., and Sun Y. Streak recognition for a 3-D volumetric particle tracking velocimetry system. ASHRAE Transactions 111 2 (2005) 476-484
    • (2005) ASHRAE Transactions , vol.111 , Issue.2 , pp. 476-484
    • Wang, A.1    Zhang, Y.2    Sun, Y.3
  • 14
    • 2442458980 scopus 로고    scopus 로고
    • An algorithm of stereoscopic particle image velocimetry for full-scale room airflow studies
    • Sun Y., Zhang Y., Zhao L., and Wang X. An algorithm of stereoscopic particle image velocimetry for full-scale room airflow studies. ASHRAE Transactions 110 1 (2004) 75-80
    • (2004) ASHRAE Transactions , vol.110 , Issue.1 , pp. 75-80
    • Sun, Y.1    Zhang, Y.2    Zhao, L.3    Wang, X.4
  • 15
    • 35448929813 scopus 로고    scopus 로고
    • ASHRAE Standard 129-1997. Measuring air-change effectiveness. Atlanta: American Society of Heating, Refrigerating and Air Conditioning Engineers, Inc. 1997.
  • 16
    • 0035176530 scopus 로고    scopus 로고
    • Relative ventilation effectiveness in a mechanically ventilated airspace under isothermal conditions
    • Maghirang R.G., Jerez S.B., and Predicala B.Z. Relative ventilation effectiveness in a mechanically ventilated airspace under isothermal conditions. ASAE Transactions 44 3 (2001) 691-696
    • (2001) ASAE Transactions , vol.44 , Issue.3 , pp. 691-696
    • Maghirang, R.G.1    Jerez, S.B.2    Predicala, B.Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.