메뉴 건너뛰기




Volumn 34, Issue 4, 2011, Pages 352-359

Current status of vertebroplasty for osteoporotic compression fracture

Author keywords

Bone cement; Compression fracture; Osteoporosis; Vertebroplasty

Indexed keywords

ANALGESIC AGENT; BONE CEMENT;

EID: 80052669445     PISSN: 20720939     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (19)

References (59)
  • 1
    • 1542343075 scopus 로고
    • The clinical consequences of vertebral compression fracture
    • Silverman SL. The clinical consequences of vertebral compression fracture. Bone 1992;13:27-31.
    • (1992) Bone , vol.13 , pp. 27-31
    • Silverman, S.L.1
  • 2
    • 0029942682 scopus 로고    scopus 로고
    • The clinical impact of vertebral fractures: Quality of life in women with osteoporosis
    • Gold DT. The clinical impact of vertebral fractures: quality of life in women with osteoporosis. Bone 1996;18:185S-9S.
    • (1996) Bone , vol.18
    • Gold, D.T.1
  • 3
    • 0036559453 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for the treatment of osteoporotic vertebral compression fractures: A preliminary report
    • Chen JF, Lee ST, Lui TN, Wu CT, Liao CC. Percutaneous vertebroplasty for the treatment of osteoporotic vertebral compression fractures: a preliminary report. Chang Gung Med J 2002;25:306-14.
    • (2002) Chang Gung Med J , vol.25 , pp. 306-314
    • Chen, J.F.1    Lee, S.T.2    Lui, T.N.3    Wu, C.T.4    Liao, C.C.5
  • 4
    • 0026439770 scopus 로고
    • Transpedicular screw-rod fixation of the lumbar spine: Operative technique and outcome in 104 cases
    • Dickman CA, Fessler RG, MacMillan M, Haid RW. Transpedicular screw-rod fixation of the lumbar spine: operative technique and outcome in 104 cases. J Neurosurg 1992;77:860-70.
    • (1992) J Neurosurg , vol.77 , pp. 860-870
    • Dickman, C.A.1    Fessler, R.G.2    McMillan, M.3    Haid, R.W.4
  • 5
    • 0043165850 scopus 로고
    • Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty
    • Galibert P, Deramond H, Rosat P, Le Gars D. Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty. Neurochirurgie 1987;33:166-8.
    • (1987) Neurochirurgie , vol.33 , pp. 166-168
    • Galibert, P.1    Deramond, H.2    Rosat, P.3    le Gars, D.4
  • 6
    • 35848970037 scopus 로고    scopus 로고
    • Clinical evaluation of vertebroplasty for multiple-level osteoporotic spinal compression fracture in the elderly
    • Yu SW, Yang SC, Kao YH, Yen CY, Tu YK, Chen LH. Clinical evaluation of vertebroplasty for multiple-level osteoporotic spinal compression fracture in the elderly. Arch Orthop Trauma Surg 2008;128:97-101.
    • (2008) Arch Orthop Trauma Surg , vol.128 , pp. 97-101
    • Yu, S.W.1    Yang, S.C.2    Kao, Y.H.3    Yen, C.Y.4    Tu, Y.K.5    Chen, L.H.6
  • 7
    • 77954012709 scopus 로고    scopus 로고
    • Comparison of 5766 vertebral compression fractures treated with or with out kyphoplasty
    • Zampini JM, White AP, McGuire KJ. Comparison of 5766 vertebral compression fractures treated with or with out kyphoplasty. Clin Orthop Relat Res 2010;468:1773-80.
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 1773-1780
    • Zampini, J.M.1    White, A.P.2    McGuire, K.J.3
  • 8
    • 0036169233 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for osteoporotic compression fractures: Quantitative prospective evaluation of long-term outcomes
    • Zoarski GH, Snow P, Olan WJ, Stallmeyer MJB, Dick BW, Hebel JR, De Deyne M. Percutaneous vertebroplasty for osteoporotic compression fractures: quantitative prospective evaluation of long-term outcomes. J Vasc Interv Radiol 2002;13:139-48.
    • (2002) J Vasc Interv Radiol , vol.13 , pp. 139-148
    • Zoarski, G.H.1    Snow, P.2    Olan, W.J.3    Stallmeyer, M.J.B.4    Dick, B.W.5    Hebel, J.R.6    de Deyne, M.7
  • 9
    • 4544348317 scopus 로고    scopus 로고
    • Complications of percutaneous vertebroplasty and their prevention
    • Laredo JD, Hamze B. Complications of percutaneous vertebroplasty and their prevention. Skeletal Radiol 2004;33:493-505.
    • (2004) Skeletal Radiol , vol.33 , pp. 493-505
    • Laredo, J.D.1    Hamze, B.2
  • 11
    • 0031778659 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty with polymethylmethacrylate. Technique, indications, and results
    • Deramond H, Depriester C, Galibert P, Le Gars D. Percutaneous vertebroplasty with polymethylmethacrylate. Technique, indications, and results. Radiol Clin North Am 1998;36:533-46.
    • (1998) Radiol Clin North Am , vol.36 , pp. 533-546
    • Deramond, H.1    Depriester, C.2    Galibert, P.3    le Gars, D.4
  • 12
    • 28244447728 scopus 로고    scopus 로고
    • Vertebroplasty and kyphoplasty: Filler materials
    • Lieberman IH, Togawa D, Kayanja MM. Vertebroplasty and kyphoplasty: filler materials. Spine J 2005;5:305S-316S.
    • (2005) Spine J , vol.5
    • Lieberman, I.H.1    Togawa, D.2    Kayanja, M.M.3
  • 13
  • 15
    • 77956142863 scopus 로고    scopus 로고
    • Vertebroplasty for acute osteoporotic spinal Ffactures-best evidence?
    • Clark W, Goh AC. Vertebroplasty for acute osteoporotic spinal Ffactures-best evidence? J Vasc Interv Radiol 2010;21:1330-3.
    • (2010) J Vasc Interv Radiol , vol.21 , pp. 1330-1333
    • Clark, W.1    Goh, A.C.2
  • 20
    • 77954866027 scopus 로고    scopus 로고
    • The highest level of evidence in a high impact journal: Is this the final verdict?
    • Fisher CG, Vaccaro AR. The highest level of evidence in a high impact journal: is this the final verdict? Spine 2010;35:676-7.
    • (2010) Spine , vol.35 , pp. 676-677
    • Fisher, C.G.1    Vaccaro, A.R.2
  • 21
    • 70249096606 scopus 로고    scopus 로고
    • Vertebroplasty and kyphoplasty: Reasons for concern?
    • Denaro L, Longo UG, Denaro V. Vertebroplasty and kyphoplasty: reasons for concern? Orthop Clin North Am 2009;40:465-71.
    • (2009) Orthop Clin North Am , vol.40 , pp. 465-471
    • Denaro, L.1    Longo, U.G.2    Denaro, V.3
  • 23
    • 34249320564 scopus 로고    scopus 로고
    • Kyphoplasty and vertebroplasty: How good is the evidence?
    • McKiernan FE. Kyphoplasty and vertebroplasty: how good is the evidence? Curr Rheumatol Rep 2007;9:57-65.
    • (2007) Curr Rheumatol Rep , vol.9 , pp. 57-65
    • McKiernan, F.E.1
  • 24
    • 9644260577 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for treatment of thoracolumbar spine bursting fracture
    • Chen JF, Lee ST. Percutaneous vertebroplasty for treatment of thoracolumbar spine bursting fracture. Surg Neurol 2004;62:494-500.
    • (2004) Surg Neurol , vol.62 , pp. 494-500
    • Chen, J.F.1    Lee, S.T.2
  • 25
    • 77952005547 scopus 로고    scopus 로고
    • C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty
    • Tam AL, Mohamed A, Pfister M, Chinndurai P, Rohm E, Hall AF, Wallace MJ. C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty. Spine 2010;35:1095-9.
    • (2010) Spine , vol.35 , pp. 1095-1099
    • Tam, A.L.1    Mohamed, A.2    Pfister, M.3    Chinndurai, P.4    Rohm, E.5    Hall, A.F.6    Wallace, M.J.7
  • 26
    • 0038544700 scopus 로고    scopus 로고
    • Volumetric quantification of cement leakage following percutaneous vertebroplasty in metastatic and osteoporotic vertebrae
    • Mousavi P, Roth S, Finkelstein J, Cheung G, Whyne C. Volumetric quantification of cement leakage following percutaneous vertebroplasty in metastatic and osteoporotic vertebrae. J Neurosurg 2003;99:56-9.
    • (2003) J Neurosurg , vol.99 , pp. 56-59
    • Mousavi, P.1    Roth, S.2    Finkelstein, J.3    Cheung, G.4    Whyne, C.5
  • 27
    • 2542562770 scopus 로고    scopus 로고
    • A syringe compressor for vertebroplasty: Technical note
    • Lee ST, Chen JF. A syringe compressor for vertebroplasty: technical note. Surg Neurol 2004;61:580-4.
    • (2004) Surg Neurol , vol.61 , pp. 580-584
    • Lee, S.T.1    Chen, J.F.2
  • 28
    • 0141520526 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty: Complication avoidance and technique optimization
    • Mathis JM. Percutaneous vertebroplasty: complication avoidance and technique optimization. AJNR Am J Neuroradiol 2003;24:1697-706.
    • (2003) AJNR Am J Neuroradiol , vol.24 , pp. 1697-1706
    • Mathis, J.M.1
  • 29
    • 0036083754 scopus 로고    scopus 로고
    • Is percutaneous vertebroplasty without pretreatment venography safe? Evaluation of 205 consecutives procedures
    • Vasconcelos C, Gailloud P, Beauchamp NJ, Heck DV, Murphy KJ. Is percutaneous vertebroplasty without pretreatment venography safe? Evaluation of 205 consecutives procedures. AJNR Am J Neuroradiol 2002;23:913-7.
    • (2002) AJNR Am J Neuroradiol , vol.23 , pp. 913-917
    • Vasconcelos, C.1    Gailloud, P.2    Beauchamp, N.J.3    Heck, D.V.4    Murphy, K.J.5
  • 30
    • 0141853158 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty
    • Kallmes DF, Jensen ME. Percutaneous vertebroplasty. Radiology 2003;229:27-36.
    • (2003) Radiology , vol.229 , pp. 27-36
    • Kallmes, D.F.1    Jensen, M.E.2
  • 31
    • 20444377227 scopus 로고    scopus 로고
    • Unipedicle percutaneous vertebroplasty for spinal intraosseous vacuum cleft
    • Chen LH, Lai PL, Chen WJ. Unipedicle percutaneous vertebroplasty for spinal intraosseous vacuum cleft. Clin l Orthop Relat Res 2005;435:148-53.
    • (2005) Clin l Orthop Relat Res , vol.435 , pp. 148-153
    • Chen, L.H.1    Lai, P.L.2    Chen, W.J.3
  • 33
    • 1642376359 scopus 로고    scopus 로고
    • Closed reduction vertebroplasty for the treatment of osteoporotic vertebral compression fractures. Technical note
    • Lee ST, Chen JF. Closed reduction vertebroplasty for the treatment of osteoporotic vertebral compression fractures. Technical note. J Neurosurg 2004;100:392-6.
    • (2004) J Neurosurg , vol.100 , pp. 392-396
    • Lee, S.T.1    Chen, J.F.2
  • 34
    • 51649087410 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty and bone cement leakage: Clinical experience with a new high-viscosity bone cement and delivery system for vertebral augmentation in benign and malignant compression fractures
    • Anselmetti GC, Zoarski G, Manca A, Masala S, Eminefendic H, Russo F, Regge D. Percutaneous vertebroplasty and bone cement leakage: clinical experience with a new high-viscosity bone cement and delivery system for vertebral augmentation in benign and malignant compression fractures. Cardiovasc Intervent Radiol 2008;31:937-47.
    • (2008) Cardiovasc Intervent Radiol , vol.31 , pp. 937-947
    • Anselmetti, G.C.1    Zoarski, G.2    Manca, A.3    Masala, S.4    Eminefendic, H.5    Russo, F.6    Regge, D.7
  • 35
    • 42949128144 scopus 로고    scopus 로고
    • Vertebroplasty comparing injectable calcium phosphate cement compared with polymethylmethacrylate in a unique canine vertebral body large defect model
    • Turner TM, Urban RM, Singh K, Hall DJ, Renner SM, Lim TH, Tomlinson MJ, An HS. Vertebroplasty comparing injectable calcium phosphate cement compared with polymethylmethacrylate in a unique canine vertebral body large defect model. Spine J 8:482-7.
    • Spine J , vol.8 , pp. 482-487
    • Turner, T.M.1    Urban, R.M.2    Singh, K.3    Hall, D.J.4    Renner, S.M.5    Lim, T.H.6    Tomlinson, M.J.7    An, H.S.8
  • 36
    • 75049085148 scopus 로고    scopus 로고
    • Evaluation of two novel aluminumfree, zinc-based glass polyalkenoate cements as alternatives to PMMA bone cement for use in vertebroplasty and balloon kyphoplasty
    • Lewis G, Towler MR, Boyd D, German MJ, Wren AW, Clarkin OM, Yates A. Evaluation of two novel aluminumfree, zinc-based glass polyalkenoate cements as alternatives to PMMA bone cement for use in vertebroplasty and balloon kyphoplasty. J Mater Sci Mater Med 2010;21:59-66.
    • (2010) J Mater Sci Mater Med , vol.21 , pp. 59-66
    • Lewis, G.1    Towler, M.R.2    Boyd, D.3    German, M.J.4    Wren, A.W.5    Clarkin, O.M.6    Yates, A.7
  • 37
    • 74249106127 scopus 로고    scopus 로고
    • Vertebroplasty: Only small cement volumes are required to normalize stress distributions on the vertebral bodies
    • Luo J, Daines L, Charalambous A, Adams MA, Annesley-Williams DJ, Dolan P. Vertebroplasty: only small cement volumes are required to normalize stress distributions on the vertebral bodies. Spine 2009;34:2865-73.
    • (2009) Spine , vol.34 , pp. 2865-2873
    • Luo, J.1    Daines, L.2    Charalambous, A.3    Adams, M.A.4    Annesley-Williams, D.J.5    Dolan, P.6
  • 38
    • 8444228488 scopus 로고    scopus 로고
    • A review of complications associated with vertebroplasty and kyphoplasty as reported to the Food and Drug Administration medical device related web site
    • Nussbaum DA, Gailloud P, Murphy K. A review of complications associated with vertebroplasty and kyphoplasty as reported to the Food and Drug Administration medical device related web site. J Vasc Interv Radiol 2004;15:1185-92.
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 1185-1192
    • Nussbaum, D.A.1    Gailloud, P.2    Murphy, K.3
  • 39
    • 33748086788 scopus 로고    scopus 로고
    • Vertebroplasty and kyphoplasty: A systematic review of 69 clinical studies
    • Hulme PA, Krebs J, Ferguson SJ, Berlemann U. Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studies. Spine 2006;31:1983-2001.
    • (2006) Spine , vol.31 , pp. 1983-2001
    • Hulme, P.A.1    Krebs, J.2    Ferguson, S.J.3    Berlemann, U.4
  • 40
    • 0036782669 scopus 로고    scopus 로고
    • Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: A case report
    • Lee BJ, Lee SR, Yoo, TY. Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: a case report. Spine 2002;27:419-22.
    • (2002) Spine , vol.27 , pp. 419-422
    • Lee, B.J.1    Lee, S.R.2    Yoo, T.Y.3
  • 41
    • 0032807670 scopus 로고    scopus 로고
    • Temperature elevation caused by bone cement polymerization during vertebroplasty
    • Deramond H, Wright N, Belkoff S. Temperature elevation caused by bone cement polymerization during vertebroplasty. Bone 1999;25:17.
    • (1999) Bone , vol.25 , pp. 17
    • Deramond, H.1    Wright, N.2    Belkoff, S.3
  • 42
    • 0038638437 scopus 로고    scopus 로고
    • Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty
    • Belkoff S, Molloy S. Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty. Spine 2003;28:1555.
    • (2003) Spine , vol.28 , pp. 1555
    • Belkoff, S.1    Molloy, S.2
  • 43
    • 43049134122 scopus 로고    scopus 로고
    • Inferior vena cava syndrome following percutaneous vertebroplasty with polymethylmethacrylate
    • Kao FC, Tu YK, Lai PL, Yu SW, Yen CY, Chou MC. Inferior vena cava syndrome following percutaneous vertebroplasty with polymethylmethacrylate. Spine 2008;33:329-33.
    • (2008) Spine , vol.33 , pp. 329-333
    • Kao, F.C.1    Tu, Y.K.2    Lai, P.L.3    Yu, S.W.4    Yen, C.Y.5    Chou, M.C.6
  • 44
    • 64949160827 scopus 로고    scopus 로고
    • Pulmonary cement embolism after percutaneous vertebroplasty in osteoporotic vertebral compression fractures: Incidence, characteristics, and risk factors
    • Kim YJ, Lee JW, Park KW, Yeom JS, Jeong HS, Park JM, Kang HS. Pulmonary cement embolism after percutaneous vertebroplasty in osteoporotic vertebral compression fractures: incidence, characteristics, and risk factors. Radiology 2009;251:250-9.
    • (2009) Radiology , vol.251 , pp. 250-259
    • Kim, Y.J.1    Lee, J.W.2    Park, K.W.3    Yeom, J.S.4    Jeong, H.S.5    Park, J.M.6    Kang, H.S.7
  • 45
    • 33750580404 scopus 로고    scopus 로고
    • Renal cement embolism during percutaneous vertebroplasty
    • Chung SE, Lee SH, Kim TH, Yoo KH, Jo BJ. Renal cement embolism during percutaneous vertebroplasty. Eur Spine J 2006;15:590-4.
    • (2006) Eur Spine J , vol.15 , pp. 590-594
    • Chung, S.E.1    Lee, S.H.2    Kim, T.H.3    Yoo, K.H.4    Jo, B.J.5
  • 46
    • 57649146480 scopus 로고    scopus 로고
    • Cardiac tamponade and pulmonary embolism as a complication of percutaneous vertebroplasty
    • Caynak B, Onan B, Sagbas E, Duran C, Akpinar B. Cardiac tamponade and pulmonary embolism as a complication of percutaneous vertebroplasty. Ann Thorac Surg 2009;87:299-301.
    • (2009) Ann Thorac Surg , vol.87 , pp. 299-301
    • Caynak, B.1    Onan, B.2    Sagbas, E.3    Duran, C.4    Akpinar, B.5
  • 47
    • 70349690323 scopus 로고    scopus 로고
    • Management of pulmonary cement embolism after percutaneous vertebroplasty and kyphoplasty: A systematic review of the literature
    • Krueger A, Bliemel C, Zettl R, Ruchholtz S. Management of pulmonary cement embolism after percutaneous vertebroplasty and kyphoplasty: a systematic review of the literature. Eur Spine J 2009;18:1257-65.
    • (2009) Eur Spine J , vol.18 , pp. 1257-1265
    • Krueger, A.1    Bliemel, C.2    Zettl, R.3    Ruchholtz, S.4
  • 48
    • 3543086793 scopus 로고    scopus 로고
    • Serious pyogenic spondylitis following vertebroplasty--a case report
    • Yu SW, Chen WJ, Lin WC, Chen YJ, Tu YK. Serious pyogenic spondylitis following vertebroplasty--a case report. Spine 2004;29:209-11.
    • (2004) Spine , vol.29 , pp. 209-211
    • Yu, S.W.1    Chen, W.J.2    Lin, W.C.3    Chen, Y.J.4    Tu, Y.K.5
  • 49
    • 37249083516 scopus 로고    scopus 로고
    • Adjacent vertebral failure after vertebroplasty: A biomechanical study of low-modulus PMMA cement
    • Boger A, Heini P, Windolf M, Schneider E. Adjacent vertebral failure after vertebroplasty: a biomechanical study of low-modulus PMMA cement. Eur Spine J 2007;16:2118-25.
    • (2007) Eur Spine J , vol.16 , pp. 2118-2125
    • Boger, A.1    Heini, P.2    Windolf, M.3    Schneider, E.4
  • 50
    • 76649092955 scopus 로고    scopus 로고
    • Impact of cement leakage into disks on the development of adjacent vertebral compression fractures
    • Chen WJ, Kao YH, Yang SC, Yu SW, Tu YK, Chung KC. Impact of cement leakage into disks on the development of adjacent vertebral compression fractures. J Spinal Disord Tech 2010;23:35-9.
    • (2010) J Spinal Disord Tech , vol.23 , pp. 35-39
    • Chen, W.J.1    Kao, Y.H.2    Yang, S.C.3    Yu, S.W.4    Tu, Y.K.5    Chung, K.C.6
  • 51
    • 67650631698 scopus 로고    scopus 로고
    • New vertebral fracture after vertebroplasty
    • Lo YP, Chen WJ, Chen LH, Lai PL. New vertebral fracture after vertebroplasty. J Trauma 2008;65:1439-45.
    • (2008) J Trauma , vol.65 , pp. 1439-1445
    • Lo, Y.P.1    Chen, W.J.2    Chen, L.H.3    Lai, P.L.4
  • 52
    • 0037260469 scopus 로고    scopus 로고
    • Occurrence of new vertebral body fracture after percutaneous vertebroplasty in patients with osteoporosis
    • Uppin AA, Hirsch JA, Centenera LV, Pfiefer BA, Pazianos AG, Choi IS. Occurrence of new vertebral body fracture after percutaneous vertebroplasty in patients with osteoporosis. Radiology 2003;226:119-24.
    • (2003) Radiology , vol.226 , pp. 119-124
    • Uppin, A.A.1    Hirsch, J.A.2    Centenera, L.V.3    Pfiefer, B.A.4    Pazianos, A.G.5    Choi, I.S.6
  • 53
    • 77952321658 scopus 로고    scopus 로고
    • Incident vertebral fractures in patients not undergoing vertebroplasty
    • Ehteshami Rad, Gray A LA, Kallmes DF. Incident vertebral fractures in patients not undergoing vertebroplasty. J Vasc Interv Radiol 2010;21:856-60.
    • (2010) J Vasc Interv Radiol , vol.21 , pp. 856-860
    • Ehteshami, R.A.D.1    Gray, A.L.A.2    Kallmes, D.F.3
  • 54
    • 42149125615 scopus 로고    scopus 로고
    • Refractures in cemented vertebrae after percutaneous vertebroplasty: A retrospective analysis
    • Lin WC, Lee YC, Lee CH, Kuo YL, Cheng YF, Lui CC, Cheng TT. Refractures in cemented vertebrae after percutaneous vertebroplasty: a retrospective analysis. Eur Spine J 2008;17:592-9.
    • (2008) Eur Spine J , vol.17 , pp. 592-599
    • Lin, W.C.1    Lee, Y.C.2    Lee, C.H.3    Kuo, Y.L.4    Cheng, Y.F.5    Lui, C.C.6    Cheng, T.T.7
  • 55
    • 0035879089 scopus 로고    scopus 로고
    • New technologies in spine-kyphoplasty and vertebrosplasty for the treatment of painful osteoporotic compression fractures
    • Garfin SR, Yuan HA, Reiley MA. New technologies in spine-kyphoplasty and vertebrosplasty for the treatment of painful osteoporotic compression fractures. Spine 2001;26:1511-5.
    • (2001) Spine , vol.26 , pp. 1511-1515
    • Garfin, S.R.1    Yuan, H.A.2    Reiley, M.A.3
  • 56
    • 0036790721 scopus 로고    scopus 로고
    • An in vivo comparison of the potential for extravertebral cement leak after vertebroplasty and kyphoplasty
    • Phillips FM, Todd Wetzel F, Lieberman I, Campbell-Hupp M. An in vivo comparison of the potential for extravertebral cement leak after vertebroplasty and kyphoplasty. Spine 2002;27:2173-8.
    • (2002) Spine , vol.27 , pp. 2173-2178
    • Phillips, F.M.1    Todd Wetzel, F.2    Lieberman, I.3    Campbell-Hupp, M.4
  • 57
    • 0036161351 scopus 로고    scopus 로고
    • Percutaneous balloon kyphoplasty for the correction of spinal deformity in painful vertebral body compression fractures
    • Theodorou DJ, Theodorou SJ, Duncan TD, Garfin SR, Wong WH. Percutaneous balloon kyphoplasty for the correction of spinal deformity in painful vertebral body compression fractures. Clin Imaging 2002;26:1-5.
    • (2002) Clin Imaging , vol.26 , pp. 1-5
    • Theodorou, D.J.1    Theodorou, S.J.2    Duncan, T.D.3    Garfin, S.R.4    Wong, W.H.5
  • 58
    • 69249213607 scopus 로고    scopus 로고
    • Comparison of kyphoplasty and vertebroplasty in the treatment of fresh vertebral compression fractures
    • Schofer MD, Efe T, Timmesfeld N, Kortmann HR, Quante M. Comparison of kyphoplasty and vertebroplasty in the treatment of fresh vertebral compression fractures. Arch Orthop Trauma Surg 2009;129:1391-9.
    • (2009) Arch Orthop Trauma Surg , vol.129 , pp. 1391-1399
    • Schofer, M.D.1    Efe, T.2    Timmesfeld, N.3    Kortmann, H.R.4    Quante, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.