메뉴 건너뛰기




Volumn 21, Issue 8, 2011, Pages 1764-1771

Brachial plexus MR imaging: Accuracy and reproducibility of DTI-derived measurements and fibre tractography at 3.0-T

Author keywords

Apparent diffusion coefficient; Brachial plexus; Diffusion tensor imaging; Fractional anisotropy; Minimum detectable differences; MRI; Repeatibility; Reproducibility

Indexed keywords

ADULT; ARTICLE; BRACHIAL PLEXUS; DIAGNOSTIC ACCURACY; DIFFUSION TENSOR IMAGING; FEMALE; FRACTIONAL ANISOTROPY; HUMAN; IMAGING SYSTEM; INTERRATER RELIABILITY; INTRARATER RELIABILITY; MALE; MEASUREMENT; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; REPRODUCIBILITY; TRACTOGRAPHY;

EID: 80052652268     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-011-2100-z     Document Type: Article
Times cited : (60)

References (28)
  • 1
    • 0036868662 scopus 로고    scopus 로고
    • Fiber tracking: Principles and strategies - A technical review
    • DOI 10.1002/nbm.781
    • Mori S, van Zijl PC (2002) Fiber tracking: principles and strategies: a technical review. NMR Biomed 15:468-480. (Pubitemid 36054510)
    • (2002) NMR in Biomedicine , vol.15 , Issue.7-8 , pp. 468-480
    • Mori, S.1    Van Zijl, P.C.M.2
  • 2
    • 0033563743 scopus 로고    scopus 로고
    • Diffusion magnetic resonance imaging: Its principle and applications
    • DOI 10.1002/(SICI)1097-0185(19990615)257:3<102::AID-AR7>3.0.CO;2-6
    • Mori S, Barker PB (1999) Diffusion magnetic resonance imaging: its principle and applications. Anat Rec 257:102-109. (Pubitemid 29328295)
    • (1999) Anatomical Record , vol.257 , Issue.3 , pp. 102-109
    • Mori, S.1
  • 3
    • 0037367362 scopus 로고    scopus 로고
    • Basic principles of diffusion-weighted imaging
    • DOI 10.1016/S0720-048X(02)00303-0, PII S0720048X02003030
    • Bammer R (2003) Basic principles of diffusion-weighted imaging. Eur J Radiol 45:169-184. (Pubitemid 36197713)
    • (2003) European Journal of Radiology , vol.45 , Issue.3 , pp. 169-184
    • Bammer, R.1
  • 4
    • 0037366335 scopus 로고    scopus 로고
    • In vivo MR tractography using diffusion imaging
    • DOI 10.1016/S0720-048X(02)00311-X, PII S0720048X0200311X
    • Bammer R, Acar B, Moseley ME (2003) In vivo MR tractography using diffusion imaging. Eur J Radiol 45:223-234. (Pubitemid 36197718)
    • (2003) European Journal of Radiology , vol.45 , Issue.3 , pp. 223-234
    • Bammer, R.1    Acar, B.2    Moseley, M.E.3
  • 5
    • 35349015772 scopus 로고    scopus 로고
    • Diffusion-tensor MR imaging and tractography: Exploring brain microstructure and connectivity
    • DOI 10.1148/radiol.2452060445
    • Nucifora PG, Verma R, Lee SK, Melhem ER (2007) Diffusiontensor MR imaging and tractography: exploring brain microstructure and connectivity. Radiology 245:367-384. (Pubitemid 47612518)
    • (2007) Radiology , vol.245 , Issue.2 , pp. 367-384
    • Nucifora, P.G.P.1    Verma, R.2    Lee, S.-K.3    Melhem, E.R.4
  • 6
    • 0028154030 scopus 로고
    • MR diffusion tensor spectroscopy and imaging
    • Basser P, Mattiello J, LeBihan D (1994) MR diffusion tensor spectroscopy and imaging. Biophys J 66:259-267. (Pubitemid 24016507)
    • (1994) Biophysical Journal , vol.66 , Issue.1 , pp. 259-267
    • Basser, P.J.1    Mattiello, J.2    LeBihan, D.3
  • 7
    • 0141517633 scopus 로고    scopus 로고
    • Diffusion tensor imaging detects corticospinal tract involvement at multiple levels in amyotrophic lateral sclerosis
    • Toosy AT, Werring DJ, Orrell RW et al (2003) Diffusion tensor imaging detects corticospinal tract involvement at multiple levels in amyotrophic lateral sclerosis. J Neurol Neurosurg Psychiatry 74:1250-1257.
    • (2003) J Neurol Neurosurg Psychiatry , vol.74 , pp. 1250-1257
    • Toosy, A.T.1    Werring, D.J.2    Orrell, R.W.3
  • 10
    • 0141853120 scopus 로고    scopus 로고
    • Diffusion-weighted MR imaging with apparent diffusion coefficient and apparent diffusion tensor maps in cervical spondylotic myelopathy
    • DOI 10.1148/radiol.2291020658
    • Demir A, Ries M, Moonen CT et al (2003) Diffusion-weighted MR imaging with apparent diffusion coefficient and apparent diffusion tensor maps in cervical spondylotic myelopathy. Radiology 229:37-43. (Pubitemid 37152102)
    • (2003) Radiology , vol.229 , Issue.1 , pp. 37-43
    • Demir, A.1    Ries, M.2    Moonen, C.T.W.3    Vital, J.-M.4    Dehais, J.5    Arne, P.6    Caille, J.-M.7    Dousset, V.8
  • 11
    • 31944444655 scopus 로고    scopus 로고
    • Line scan diffusion tensor MRI at low magnetic field strength: Feasibility study of cervical spondylotic myelopathy in an early clinical stage
    • DOI 10.1002/jmri.20488
    • Hori M, Okubo T, Aoki S et al (2006) Line scan diffusion tensor MRI at low magnetic field strength: feasibility study of cervical spondylotic myelopathy in an early clinical stage. J Magn Reson Imaging 23:183-188. (Pubitemid 43191072)
    • (2006) Journal of Magnetic Resonance Imaging , vol.23 , Issue.2 , pp. 183-188
    • Hori, M.1    Okubo, T.2    Aoki, S.3    Kumagai, H.4    Araki, T.5
  • 12
    • 21244469101 scopus 로고    scopus 로고
    • Apparent diffusion coefficient and fractional anisotropy in spinal cord: Age and cervical spondylosis-related changes
    • DOI 10.1002/jmri.20357
    • Mamata H, Jolesz FA, Maier SE (2005) Apparent diffusion coefficient and fractional anisotropy in spinal cord: age and cervical spondylosis-related changes. J Magn Reson Imaging 22:38-43. (Pubitemid 40885126)
    • (2005) Journal of Magnetic Resonance Imaging , vol.22 , Issue.1 , pp. 38-43
    • Mamata, H.1    Jolesz, F.A.2    Maier, S.E.3
  • 14
    • 77951665858 scopus 로고    scopus 로고
    • 3 T magnetic resonance diffusion tensor imaging and fibre tracking in cervical myelopathy
    • Xiangshui M, Xiangjun C, Xiaoming Z et al (2010) 3 T magnetic resonance diffusion tensor imaging and fibre tracking in cervical myelopathy. Clin Radiol 65:465-473.
    • (2010) Clin Radiol , vol.65 , pp. 465-473
    • Xiangshui, M.1    Xiangjun, C.2    Xiaoming, Z.3
  • 15
    • 77949261441 scopus 로고    scopus 로고
    • Diffusion tensor imaging (DTI) and tractography of the brachial plexus: Feasibility and initial experience in neoplastic conditions
    • Vargas MI, Viallon M, Nguyen D, Delavelle J, Becker M (2010) Diffusion tensor imaging (DTI) and tractography of the brachial plexus: feasibility and initial experience in neoplastic conditions. Neuroradiology 52:237-245.
    • (2010) Neuroradiology , vol.52 , pp. 237-245
    • Vargas, M.I.1    Viallon, M.2    Nguyen, D.3    Delavelle, J.4    Becker, M.5
  • 17
    • 74749085422 scopus 로고    scopus 로고
    • Evaluation of diffusion tensor imaging and fiber tractography of the median nerve: Preliminary results on intrasubject variability and precision of measurements
    • Andreisek G, White LM, Kassner A, Sussman MS (2010) Evaluation of diffusion tensor imaging and fiber tractography of the median nerve: preliminary results on intrasubject variability and precision of measurements. AJR Am J Roentgenol 194:W65- W72.
    • (2010) AJR Am J Roentgenol , vol.194
    • Andreisek, G.1    White, L.M.2    Kassner, A.3    Sussman, M.S.4
  • 18
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159-174. (Pubitemid 8054849)
    • (1977) Biometrics , vol.33 , Issue.1 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 19
    • 0030017818 scopus 로고    scopus 로고
    • Measurement error proportional to the mean
    • Bland JM, Altman DG (1996) Measurement error proportional to the mean. BMJ 313:106. (Pubitemid 26257767)
    • (1996) British Medical Journal , vol.313 , Issue.7049 , pp. 106
    • Bland, J.M.1    Altman, D.G.2
  • 20
    • 0030596840 scopus 로고    scopus 로고
    • Measurement error
    • Bland JM, Altman DG (1996) Measurement error. BMJ 313:744.
    • (1996) BMJ , vol.313 , pp. 744
    • Bland, J.M.1    Altman, D.G.2
  • 21
    • 0036199430 scopus 로고    scopus 로고
    • Reproducibility of quantitative dynamic MRI of normal human tissues
    • DOI 10.1002/nbm.732
    • Padhani AR, Hayes C, Landau S, Leach MO (2002) Reproducibility of quantitative dynamic MRI of normal human tissues. NMR Biomed 15:143-153. (Pubitemid 34213404)
    • (2002) NMR in Biomedicine , vol.15 , Issue.2 , pp. 143-153
    • Padhani, A.R.1    Hayes, C.2    Landau, S.3    Leach, M.O.4
  • 22
    • 80755159528 scopus 로고    scopus 로고
    • Measurement of renal volume using respiratory-gated MRI in subjects without known kidney disease: Intraobserver, interobserver, and interstudy reproducibility
    • doi:10.1016/j. ejrad.2010.09.005
    • Di Leo G, Di Terlizzi F, Flor N, Morganti A, Sardanelli F (2010) Measurement of renal volume using respiratory-gated MRI in subjects without known kidney disease: intraobserver, interobserver, and interstudy reproducibility. Eur J Radiol. doi:10.1016/j. ejrad.2010.09.005.
    • (2010) Eur J Radiol.
    • Di Leo, G.1    Di Terlizzi, F.2    Flor, N.3    Morganti, A.4    Sardanelli, F.5
  • 23
    • 35248816901 scopus 로고    scopus 로고
    • Effects of signal-to-noise ratio on the accuracy and reproducibility of diffusion tensor imaging-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T
    • DOI 10.1002/jmri.21053
    • Farrell JA, Landman BA, Jones CK, Smith SA, Prince JL, van Zijl PC et al (2007) Effects of signal-to-noise ratio on the accuracy and reproducibility of diffusion tensor imaging-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5 T. J Magn Reson Imaging 26:756-767. (Pubitemid 350194602)
    • (2007) Journal of Magnetic Resonance Imaging , vol.26 , Issue.3 , pp. 756-767
    • Farrell, J.A.D.1    Landman, B.A.2    Jones, C.K.3    Smith, S.A.4    Prince, J.L.5    Van Zijl, P.C.M.6    Mori, S.7
  • 24
    • 77957349542 scopus 로고    scopus 로고
    • Consensus interpretation in imaging research: Is there a better way?
    • Bankier AA, Levine D, Halpern EF, Kressel HY (2010) Consensus interpretation in imaging research: is there a better way? Radiology 257:14-17.
    • (2010) Radiology , vol.257 , pp. 14-17
    • Bankier, A.A.1    Levine, D.2    Halpern, E.F.3    Kressel, H.Y.4
  • 25
    • 61749088918 scopus 로고    scopus 로고
    • Shortand midterm reproducibility of apparent diffusion coefficient measurements at 3.0-T diffusion-weighted imaging of the abdomen
    • Braithwaite AC, Dale BM, Boll DT, Merkle EM (2009) Shortand midterm reproducibility of apparent diffusion coefficient measurements at 3.0-T diffusion-weighted imaging of the abdomen. Radiology 250:459-465.
    • (2009) Radiology , vol.250 , pp. 459-465
    • Braithwaite, A.C.1    Dale, B.M.2    Boll, D.T.3    Merkle, E.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.