메뉴 건너뛰기




Volumn 16, Issue 6, 2011, Pages 852-856

The influence of platform switching on the biomechanical aspects of the implant-abutment system. A three dimensional finite element study

Author keywords

Bone mechanical response; Finite element analysis; Implant abutment stres; Platform switching

Indexed keywords

ARTICLE; BIOMECHANICS; CORTICAL BONE; DENTURE; FINITE ELEMENT ANALYSIS; TRABECULAR BONE;

EID: 80052599308     PISSN: 16984447     EISSN: 16986946     Source Type: Journal    
DOI: 10.4317/medoral.17243     Document Type: Article
Times cited : (25)

References (20)
  • 1
    • 4644291445 scopus 로고    scopus 로고
    • Biomechanical aspects of marginal bone resorption around osseointegrated implants: Considerations based on a three-dimensional finite element analysis
    • Kitamura E, Stegaroiu R, Nomura S, Miyakawa O. Biomechanical aspects of marginal bone resorption around osseointegrated implants: considerations based on a three-dimensional finite element analysis. Clin Oral Implants Res. 2004;15:401-12.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 401-412
    • Kitamura, E.1    Stegaroiu, R.2    Nomura, S.3    Miyakawa, O.4
  • 2
    • 0031183716 scopus 로고    scopus 로고
    • A qualitative and quantitative method for evaluating implant success: A 5-year retrospective analysis of the Brånemark implant
    • Roos J, Sennerby L, Lekholm U, Jemt T, Gröndahl K, Albrektsson T. A qualitative and quantitative method for evaluating implant success: a 5-year retrospective analysis of the Brånemark implant. Int J Oral Maxillofac Implants. 1997;12:504-14.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 504-514
    • Roos, J.1    Sennerby, L.2    Lekholm, U.3    Jemt, T.4    Gröndahl, K.5    Albrektsson, T.6
  • 4
    • 33748290174 scopus 로고    scopus 로고
    • Influence of forces on peri-implant bone
    • Isidor F. Influence of forces on peri-implant bone. Clin Oral Implants Res. 2006;17Suppl 2:8-18.
    • (2006) Clin Oral Implants Res , vol.17 , Issue.SUPPL. 2 , pp. 8-18
    • Isidor, F.1
  • 5
    • 67649224060 scopus 로고    scopus 로고
    • Platform-switched restorations on wide-diameter implants: A 5-year clinical prospective study
    • Vigolo P, Givani A. Platform-switched restorations on wide-diameter implants: a 5-year clinical prospective study. Int J Oral Maxillofac Implants. 2009;24:103-9.
    • (2009) Int J Oral Maxillofac Implants , vol.24 , pp. 103-109
    • Vigolo, P.1    Givani, A.2
  • 6
    • 38149054263 scopus 로고    scopus 로고
    • Preservation of peri-implant soft and hard tissues using platform switching of implants placed in immediate extraction sockets: A proof-of-concept study with 12- to 36-month follow-up
    • Canullo L, Rasperini G. Preservation of peri-implant soft and hard tissues using platform switching of implants placed in immediate extraction sockets: a proof-of-concept study with 12- to 36-month follow-up. Int J Oral Maxillofac Implants. 2007;22:995-1000.
    • (2007) Int J Oral Maxillofac Implants , vol.22 , pp. 995-1000
    • Canullo, L.1    Rasperini, G.2
  • 8
    • 77649207430 scopus 로고    scopus 로고
    • The microbiota associated with implants restored with platform switching: A preliminary report
    • Canullo L, Quaranta A, Teles RP. The microbiota associated with implants restored with platform switching: a preliminary report. J Periodontol. 2010;81:403-11.
    • (2010) J Periodontol , vol.81 , pp. 403-411
    • Canullo, L.1    Quaranta, A.2    Teles, R.P.3
  • 9
    • 31944431959 scopus 로고    scopus 로고
    • Platform switching: A new concept in implant dentistry for controlling postrestorative crestal bone levels
    • Lazzara RJ, Porter SS. Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels. Int J Periodontics Restorative Dent. 2006;26:9-17.
    • (2006) Int J Periodontics Restorative Dent , vol.26 , pp. 9-17
    • Lazzara, R.J.1    Porter, S.S.2
  • 10
    • 78249253317 scopus 로고    scopus 로고
    • Platform switching for marginal bone preservation around dental implants: A systematic review and meta-analysis
    • Atieh MA, Ibrahim HM, Atieh AH. Platform switching for marginal bone preservation around dental implants: a systematic review and meta-analysis. J Periodontol. 2010;81:1350-66.
    • (2010) J Periodontol , vol.81 , pp. 1350-1366
    • Atieh, M.A.1    Ibrahim, H.M.2    Atieh, A.H.3
  • 11
    • 72949099260 scopus 로고    scopus 로고
    • Platform switching and marginal bone-level alterations: The results of a randomized-controlled trial
    • Canullo L, Fedele GR, Iannello G, Jepsen S. Platform switching and marginal bone-level alterations: the results of a randomized-controlled trial. Clin Oral Implants Res. 2010;21:115-21.
    • (2010) Clin Oral Implants Res , vol.21 , pp. 115-121
    • Canullo, L.1    Fedele, G.R.2    Iannello, G.3    Jepsen, S.4
  • 12
    • 34548700364 scopus 로고    scopus 로고
    • Biomechanical analysis on platform switching: Is there any biomechanical rationale?
    • Maeda Y, Miura J, Taki I, Sogo M. Biomechanical analysis on platform switching: is there any biomechanical rationale? Clin Oral Implants Res. 2007;18:581-4.
    • (2007) Clin Oral Implants Res , vol.18 , pp. 581-584
    • Maeda, Y.1    Miura, J.2    Taki, I.3    Sogo, M.4
  • 14
    • 26944480482 scopus 로고    scopus 로고
    • Effects of splinted prosthesis supported a wide implant or two implants: A three-dimensional finite element analysis
    • Huang HL, Huang JS, Ko CC, Hsu JT, Chang CH, Chen MY. Effects of splinted prosthesis supported a wide implant or two implants: a three-dimensional finite element analysis. Clin Oral Implants Res. 2005;16:466-72.
    • (2005) Clin Oral Implants Res , vol.16 , pp. 466-472
    • Huang, H.L.1    Huang, J.S.2    Ko, C.C.3    Hsu, J.T.4    Chang, C.H.5    Chen, M.Y.6
  • 15
    • 34250334131 scopus 로고    scopus 로고
    • Factors influencing the preservation of the periimplant marginal bone
    • Hermann F, Lerner H, Palti A. Factors influencing the preservation of the periimplant marginal bone. Implant Dent. 2007;16:165-75.
    • (2007) Implant Dent , vol.16 , pp. 165-175
    • Hermann, F.1    Lerner, H.2    Palti, A.3
  • 16
    • 62349103691 scopus 로고    scopus 로고
    • Double-blind randomized controlled trial study on post-extraction immediately restored implants using the switching platform concept: Soft tissue response. Preliminary report
    • Canullo L, Iurlaro G, Iannello G. Double-blind randomized controlled trial study on post-extraction immediately restored implants using the switching platform concept: soft tissue response. Preliminary report. Clin Oral Implants Res. 2009;20:414-20.
    • (2009) Clin Oral Implants Res , vol.20 , pp. 414-420
    • Canullo, L.1    Iurlaro, G.2    Iannello, G.3
  • 17
    • 55749100339 scopus 로고    scopus 로고
    • Effect of microthreads and platform switching on crestal bone stress levels: A finite element analysis
    • Schrotenboer J, Tsao YP, Kinariwala V, Wang HL. Effect of microthreads and platform switching on crestal bone stress levels: a finite element analysis. J Periodontol. 2008;79:2166-72.
    • (2008) J Periodontol , vol.79 , pp. 2166-2172
    • Schrotenboer, J.1    Tsao, Y.P.2    Kinariwala, V.3    Wang, H.L.4
  • 18
    • 0035375020 scopus 로고    scopus 로고
    • Dynamic fatigue properties of the dental implant-abutment interface: Joint opening in wide-diameter versus standard-diameter hex-type implants
    • Hoyer SA, Stanford CM, Buranadham S, Fridrich T, Wagner J, Gratton D. Dynamic fatigue properties of the dental implant-abutment interface: joint opening in wide-diameter versus standard-diameter hex-type implants. J Prosthet Dent. 2001;85:599-607.
    • (2001) J Prosthet Dent , vol.85 , pp. 599-607
    • Hoyer, S.A.1    Stanford, C.M.2    Buranadham, S.3    Fridrich, T.4    Wagner, J.5    Gratton, D.6
  • 20
    • 33646232732 scopus 로고    scopus 로고
    • Influence of implant abutment type on stress distribution in bone under various loading conditions using finite element analysis
    • Chun HJ, Shin HS, Han CH, Lee SH. Influence of implant abutment type on stress distribution in bone under various loading conditions using finite element analysis. Int J Oral Maxillofac Implants. 2006;21:195-202.
    • (2006) Int J Oral Maxillofac Implants , vol.21 , pp. 195-202
    • Chun, H.J.1    Shin, H.S.2    Han, C.H.3    Lee, S.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.