메뉴 건너뛰기




Volumn 6, Issue 9, 2011, Pages 2105-2107

The patient as a limit to dialysis technology

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFICIAL KIDNEY; BIOMEDICAL TECHNOLOGY ASSESSMENT; BLOOD FLOW VELOCITY; DIALYSATE; EDITORIAL; HEMATOCRIT; HEMODIALYSIS; HUMAN; KIDNEY PLASMA FLOW; MEDICAL TECHNOLOGY; QUALITY OF LIFE; SLEEP QUALITY; ULTRAFILTRATION;

EID: 80052593004     PISSN: 15559041     EISSN: 1555905X     Source Type: Journal    
DOI: 10.2215/CJN.07320711     Document Type: Editorial
Times cited : (4)

References (29)
  • 1
    • 80052579441 scopus 로고    scopus 로고
    • Dialysate flow rate and delivered Kt/Vurea for dialyzers with enhanced dialysate flow distribution
    • Ward RA, Idoux JW, Hamdan H, Ouseph R, Depner TA, Golper TA: Dialysate flow rate and delivered Kt/Vurea for dialyzers with enhanced dialysate flow distribution. Clin J Am Soc Nephrol 6: 2235-2239, 2011
    • (2011) Clin J Am Soc Nephrol , vol.6 , pp. 2235-2239
    • Ward, R.A.1    Idoux, J.W.2    Hamdan, H.3    Ouseph, R.4    Depner, T.A.5    Golper, T.A.6
  • 2
    • 23844483444 scopus 로고    scopus 로고
    • Combining SPECT medical imaging and computational fluid dynamics for analyzing blood and dialysate flow in hemodialyzers
    • Eloot S, D'Asseler Y, De Bondt P, Verdonck R: Combining SPECT medical imaging and computational fluid dynamics for analyzing blood and dialysate flow in hemodialyzers. Int J Artif Organs 28: 739-749, 2005
    • (2005) Int J Artif Organs , vol.28 , pp. 739-749
    • Eloot, S.1    D'asseler, Y.2    de Bondt, P.3    Verdonck, R.4
  • 3
    • 0035654925 scopus 로고    scopus 로고
    • Blood and dialysate flow distributions in hollow-fiber hemodialyzers analyzed by computerized helical scanning technique
    • Ronco C, Brendolan A, Crepaldi C, Rodighiero M, Scabardi M: Blood and dialysate flow distributions in hollow-fiber hemodialyzers analyzed by computerized helical scanning technique. J Am Soc Nephrol 13[SUPPL. 1]: S53-S61, 2002
    • (2002) J Am Soc Nephrol , vol.13 , Issue.SUPPL. 1
    • Ronco, C.1    Brendolan, A.2    Crepaldi, C.3    Rodighiero, M.4    Scabardi, M.5
  • 5
    • 0041307098 scopus 로고    scopus 로고
    • Effect of spacer yarns on the dialysate flow distribution of hemodialyzers: A magnetic resonance imaging study
    • Poh CK, Hardy PA, Liao Z, Huang Z, Clark WR, Gao D: Effect of spacer yarns on the dialysate flow distribution of hemodialyzers: A magnetic resonance imaging study. ASAIO J 49: 440-448, 2003
    • (2003) ASAIO J , vol.49 , pp. 440-448
    • Poh, C.K.1    Hardy, P.A.2    Liao, Z.3    Huang, Z.4    Clark, W.R.5    Gao, D.6
  • 6
    • 0030873353 scopus 로고    scopus 로고
    • Impact of spacing filaments external to hollow fibers on dialysate flow distribution and dialyzer performance
    • Ronco C, Scabardi M, Goldoni M, Brendolan A, Crepaldi C, La Greca G: Impact of spacing filaments external to hollow fibers on dialysate flow distribution and dialyzer performance. Int J Artif Organs 20: 261-266, 1997
    • (1997) Int J Artif Organs , vol.20 , pp. 261-266
    • Ronco, C.1    Scabardi, M.2    Goldoni, M.3    Brendolan, A.4    Crepaldi, C.5    la Greca, G.6
  • 7
    • 78649499044 scopus 로고    scopus 로고
    • Effect of increasing dialysate flow rate on diffusive mass transfer of urea, phosphate and beta2-microglobulin during clinical haemodialysis
    • Bhimani JP, Ouseph R, Ward RA: Effect of increasing dialysate flow rate on diffusive mass transfer of urea, phosphate and beta2-microglobulin during clinical haemodialysis. Nephrol Dial Transplant 25: 3990-3995, 2010
    • (2010) Nephrol Dial Transplant , vol.25 , pp. 3990-3995
    • Bhimani, J.P.1    Ouseph, R.2    Ward, R.A.3
  • 8
    • 0013990616 scopus 로고
    • Operating parameters and performance criteria for hemodialyzers and other membrane-separation devices
    • Michaels AS: Operating parameters and performance criteria for hemodialyzers and other membrane-separation devices. Trans Am Soc Artif Intern Organs 12: 387-392, 1966
    • (1966) Trans Am Soc Artif Intern Organs , vol.12 , pp. 387-392
    • Michaels, A.S.1
  • 9
    • 0027688501 scopus 로고
    • Second generation logarithmic estimates of single- pool variable volume Kt/V: An analysis of error
    • Daugirdas JT: Second generation logarithmic estimates of single- pool variable volume Kt/V: An analysis of error. J Am Soc Nephrol 4: 1205-1213, 1993
    • (1993) J Am Soc Nephrol , vol.4 , pp. 1205-1213
    • Daugirdas, J.T.1
  • 10
    • 0028892923 scopus 로고
    • Overestimation of hemodialysis dose depends on dialysis efficiency by regional blood flow but not by conventional two pool urea kinetic analysis
    • Daugirdas JT, Schneditz D: Overestimation of hemodialysis dose depends on dialysis efficiency by regional blood flow but not by conventional two pool urea kinetic analysis. ASAIO J 41: M719-M724, 1995
    • (1995) ASAIO J , vol.41
    • Daugirdas, J.T.1    Schneditz, D.2
  • 11
    • 0018864615 scopus 로고
    • Total body water volumes for adult males and females estimated from simple anthropometric measurements
    • Watson PE, Watson ID, Batt RD: Total body water volumes for adult males and females estimated from simple anthropometric measurements. Am J Clin Nutr 33: 27-39, 1980
    • (1980) Am J Clin Nutr , vol.33 , pp. 27-39
    • Watson, P.E.1    Watson, I.D.2    Batt, R.D.3
  • 12
    • 33745285983 scopus 로고    scopus 로고
    • Clinical Practice Guidelines for Hemodialysis Adequacy, update 2006
    • National Kidney Foundation
    • National Kidney Foundation: Clinical Practice Guidelines for Hemodialysis Adequacy, update 2006. Am J Kidney Dis 48: S2-S90, 2006
    • (2006) Am J Kidney Dis , vol.48
  • 14
    • 0030988709 scopus 로고    scopus 로고
    • Hemodialyzer mass transfer-area coefficients for urea increase at high dialysate flow rates. The Hemodialysis (HEMO) Study
    • Leypoldt JK, Cheung AK, Agodoa LY, Daugirdas JT, Greene T, Keshaviah PR: Hemodialyzer mass transfer-area coefficients for urea increase at high dialysate flow rates. The Hemodialysis (HEMO) Study. Kidney Int 51: 2013-2017, 1997
    • (1997) Kidney Int , vol.51 , pp. 2013-2017
    • Leypoldt, J.K.1    Cheung, A.K.2    Agodoa, L.Y.3    Daugirdas, J.T.4    Greene, T.5    Keshaviah, P.R.6
  • 15
    • 0035151511 scopus 로고    scopus 로고
    • Increasing dialysate flow rate increases dialyzer urea mass transfer-area coefficients during clinical use
    • Ouseph R, Ward RA: Increasing dialysate flow rate increases dialyzer urea mass transfer-area coefficients during clinical use. Am J Kidney Dis 37: 316-320, 2001
    • (2001) Am J Kidney Dis , vol.37 , pp. 316-320
    • Ouseph, R.1    Ward, R.A.2
  • 18
    • 34447649369 scopus 로고    scopus 로고
    • Complex compartmental behavior of small water-soluble uremic retention solutes: Evaluation by direct measurements in plasma and erythrocytes
    • Eloot S, Torremans A, de Smet R, Marescau B, De Deyn PP, Verdonck P, Vanholder R: Complex compartmental behavior of small water-soluble uremic retention solutes: Evaluation by direct measurements in plasma and erythrocytes. Am J Kidney Dis 50: 279-288, 2007
    • (2007) Am J Kidney Dis , vol.50 , pp. 279-288
    • Eloot, S.1    Torremans, A.2    de Smet, R.3    Marescau, B.4    de Deyn, P.P.5    Verdonck, P.6    Vanholder, R.7
  • 20
    • 0036236303 scopus 로고    scopus 로고
    • Mexican Nephrology Collaborative Study Group: Effects of increased peritoneal clearances on mortality rates in peritoneal dialysis: ADEMEX, a prospective, randomized, controlled trial
    • Paniagua R, Amato D, Vonesh E, Correa-Rotter R, Ramos A, Moran J, Mujais S: Mexican Nephrology Collaborative Study Group: Effects of increased peritoneal clearances on mortality rates in peritoneal dialysis: ADEMEX, a prospective, randomized, controlled trial. J Am Soc Nephrol 13: 1307-1320, 2002
    • (2002) J Am Soc Nephrol , vol.13 , pp. 1307-1320
    • Paniagua, R.1    Amato, D.2    Vonesh, E.3    Correa-Rotter, R.4    Ramos, A.5    Moran, J.6    Mujais, S.7
  • 21
    • 58449118342 scopus 로고    scopus 로고
    • Ledebo I, Vanholder R: Effective removal of protein-bound uraemic solutes by different convective strategies: A prospective trial
    • Meert N, Eloot S, Waterloos MA, Van Landschoot M, Dhondt A, Glorieux G, Ledebo I, Vanholder R: Effective removal of protein-bound uraemic solutes by different convective strategies: A prospective trial. Nephrol Dial Transplant 24: 562-570, 2009
    • (2009) Nephrol Dial Transplant , vol.24 , pp. 562-570
    • Meert, N.1    Eloot, S.2    Waterloos, M.A.3    van Landschoot, M.4    Dhondt, A.5    Glorieux, G.6
  • 22
    • 0032587574 scopus 로고    scopus 로고
    • Rebound kinetics of beta2- microglobulin after hemodialysis
    • Leypoldt JK, Cheung AK, Deeter RB: Rebound kinetics of beta2- microglobulin after hemodialysis. Kidney Int 56: 1571-1577, 1999
    • (1999) Kidney Int , vol.56 , pp. 1571-1577
    • Leypoldt, J.K.1    Cheung, A.K.2    Deeter, R.B.3
  • 23
    • 0036587549 scopus 로고    scopus 로고
    • Validation of a two-pool model for the kinetics of beta2-microglobulin
    • Stiller S, Xu XQ, Gruner N, Vienken J, Mann H: Validation of a two-pool model for the kinetics of beta2-microglobulin. Int J Artif Organs 25: 411-420, 2002
    • (2002) Int J Artif Organs , vol.25 , pp. 411-420
    • Stiller, S.1    Xu, X.Q.2    Gruner, N.3    Vienken, J.4    Mann, H.5
  • 25
  • 26
    • 79953878863 scopus 로고    scopus 로고
    • De Nicolò EV, Ceci E, Teutonico A, Lomonte C: Removal of uraemic retention solutes in standard bicarbonate haemodialysis and long-hour slow-flow bicarbonate haemodialysis
    • Basile C, Libutti P, Di Turo AL, Casino FG, Vernaglione L, Tundo S, Maselli P, De Nicolò EV, Ceci E, Teutonico A, Lomonte C: Removal of uraemic retention solutes in standard bicarbonate haemodialysis and long-hour slow-flow bicarbonate haemodialysis. Nephrol Dial Transplant 26: 1296-1303, 2011
    • (2011) Nephrol Dial Transplant , vol.26 , pp. 1296-1303
    • Basile, C.1    Libutti, P.2    Di Turo, A.L.3    Casino, F.G.4    Vernaglione, L.5    Tundo, S.6    Maselli, P.7
  • 28
    • 0036329759 scopus 로고    scopus 로고
    • Behavior of non-protein-bound and protein-bound uremic solutes during daily hemodialysis
    • Fagugli RM, de Smet R, Buoncristiani U, Lameire N, Vanholder R: Behavior of non-protein-bound and protein-bound uremic solutes during daily hemodialysis. Am J Kidney Dis 40: 339-347, 2002
    • (2002) Am J Kidney Dis , vol.40 , pp. 339-347
    • Fagugli, R.M.1    de Smet, R.2    Buoncristiani, U.3    Lameire, N.4    Vanholder, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.