메뉴 건너뛰기




Volumn 51, Issue 6, 1997, Pages 2013-2017

Hemodialyzer mass transfer-area coefficients for urea increase at high dialysate flow rates

Author keywords

[No Author keywords available]

Indexed keywords

UREA;

EID: 0030988709     PISSN: 00852538     EISSN: None     Source Type: Journal    
DOI: 10.1038/ki.1997.274     Document Type: Article
Times cited : (132)

References (14)
  • 2
    • 85030295588 scopus 로고    scopus 로고
    • C, KJELLSTRAND CM, KOCH KM, WINCHESTER JF, Dordrecht, Kluwer Academic, 1996, pp 34-102
    • C, KJELLSTRAND CM, KOCH KM, WINCHESTER JF, Dordrecht, Kluwer Academic, 1996, pp 34-102
  • 3
    • 0002120189 scopus 로고
    • Chronic hemodialysis prescription: A urea kinetic approach
    • edited by DAUGIRDAS JT, ING TS, Boston, Little Brown
    • DAUGIRDAS JT: Chronic hemodialysis prescription: a urea kinetic approach, in Handbook of Dialysis (2nd ed), edited by DAUGIRDAS JT, ING TS, Boston, Little Brown, 1994, pp 92-120
    • (1994) Handbook of Dialysis (2nd Ed) , pp. 92-120
    • Daugirdas, J.T.1
  • 4
    • 0002663303 scopus 로고
    • Hemodialysis: Physical principles and technical considerations
    • edited by BRENNER BM, RECTOR FC JR, Philadelphia, WB Saunders
    • COLTON CK, LOWRIE EG: Hemodialysis: Physical principles and technical considerations, in The Kidney (2nd ed), edited by BRENNER BM, RECTOR FC JR, Philadelphia, WB Saunders, 1981, pp 2425-2489
    • (1981) The Kidney (2nd Ed) , pp. 2425-2489
    • Colton, C.K.1    Lowrie, E.G.2
  • 5
    • 0026640403 scopus 로고
    • Differences in KT/V measured during dialysis and KT/V predicted from manufacturer clearance data
    • SAHA LK, VAN STONE JC: Differences in KT/V measured during dialysis and KT/V predicted from manufacturer clearance data. Int J Artif Organs 15:465-469, 1992
    • (1992) Int J Artif Organs , vol.15 , pp. 465-469
    • Saha, L.K.1    Van Stone, J.C.2
  • 7
    • 0013990616 scopus 로고
    • Operating parameters and performance criteria for hemodialyzers and other membrane-separation devices
    • MICHAELS AS: Operating parameters and performance criteria for hemodialyzers and other membrane-separation devices. Trans Am Soc Artif Intern Organs 12:387-392, 1966
    • (1966) Trans Am Soc Artif Intern Organs , vol.12 , pp. 387-392
    • Michaels, A.S.1
  • 9
    • 0018517562 scopus 로고
    • Effect of flow maldistribution on hollow fiber dialysis-experimental studies
    • NODA I, BROWN-WEST DG, GRYTE CC: Effect of flow maldistribution on hollow fiber dialysis-experimental studies. J Membr Sci 5:209-225, 1979
    • (1979) J Membr Sci , vol.5 , pp. 209-225
    • Noda, I.1    Brown-West, D.G.2    Gryte, C.C.3
  • 10
    • 0028858234 scopus 로고
    • The influence of the dialysate flow rate on hollow fiber hemodialyzer performance
    • ALLEN RA, FROST TH, HOENICH NA: The influence of the dialysate flow rate on hollow fiber hemodialyzer performance. Artif Organs 19:1176-1180, 1995
    • (1995) Artif Organs , vol.19 , pp. 1176-1180
    • Allen, R.A.1    Frost, T.H.2    Hoenich, N.A.3
  • 11
    • 84982662790 scopus 로고
    • Dialysate flow rate and dialyzer urea clearance
    • HOOTKINS R: Dialysate flow rate and dialyzer urea clearance. Semin Dial 8:53, 1995
    • (1995) Semin Dial , vol.8 , pp. 53
    • Hootkins, R.1
  • 12
    • 57249091862 scopus 로고    scopus 로고
    • Adjustments required to accurately predict in vivo hemodialysis urea clearance from in vitro derived constants
    • DEPNER TA, CHEUNG AK, DAUGIRDAS JT, GOTCH FA, GREENE T, LEYPOLDT JK: Adjustments required to accurately predict in vivo hemodialysis urea clearance from in vitro derived constants. (abstract) J Am Soc Nephrol 7:1510, 1996
    • (1996) J Am Soc Nephrol , vol.7 , pp. 1510
    • Depner, T.A.1    Cheung, A.K.2    Daugirdas, J.T.3    Gotch, F.A.4    Greene, T.5    Leypoldt, J.K.6
  • 13
    • 0028057392 scopus 로고
    • A nomogram approach to hemodialysis urea modeling
    • DAUGIRDAS JT, DEPNER TA: A nomogram approach to hemodialysis urea modeling. Am J Kidney Dis 23:33-40, 1994
    • (1994) Am J Kidney Dis , vol.23 , pp. 33-40
    • Daugirdas, J.T.1    Depner, T.A.2
  • 14
    • 8244246069 scopus 로고
    • Dialyzer urea mass transfer-area coefficient (KoA) increases at high dialysate flow rate
    • LEYPOLDT JK, CHEUNG AK, AGODOA LY, DAUGIRDAS JT, GREENE T: Dialyzer urea mass transfer-area coefficient (KoA) increases at high dialysate flow rate. (abstract) J Am Soc Nephrol 6:606, 1995
    • (1995) J Am Soc Nephrol , vol.6 , pp. 606
    • Leypoldt, J.K.1    Cheung, A.K.2    Agodoa, L.Y.3    Daugirdas, J.T.4    Greene, T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.