메뉴 건너뛰기




Volumn 31, Issue 3, 2011, Pages 429-441

High Throughput Automated LC-MS/MS Analysis of Endogenous Small Molecule Biomarkers

Author keywords

Automation; Endogenous biomarkers; High throughput; LC MS MS

Indexed keywords

BIOGENIC AMINE; BIOLOGICAL MARKER; STEROID HORMONE; VITAMIN D;

EID: 80052542674     PISSN: 02722712     EISSN: 15579832     Source Type: Journal    
DOI: 10.1016/j.cll.2011.07.008     Document Type: Review
Times cited : (8)

References (46)
  • 1
    • 84989036012 scopus 로고
    • Atmospheric pressure ionization mass spectrometry
    • Proctor C.J., Todd J.F.J. Atmospheric pressure ionization mass spectrometry. Org Mass Spec 1983, 18:509-516.
    • (1983) Org Mass Spec , vol.18 , pp. 509-516
    • Proctor, C.J.1    Todd, J.F.J.2
  • 2
    • 0023053488 scopus 로고
    • Metabolic profiling with gas chromatography-mass spectrometry and its application to clinical medicine
    • Niwa T. Metabolic profiling with gas chromatography-mass spectrometry and its application to clinical medicine. J Chromatogr 1986, 370:313-345.
    • (1986) J Chromatogr , vol.370 , pp. 313-345
    • Niwa, T.1
  • 3
    • 0034223174 scopus 로고    scopus 로고
    • Liquid chromatography-mass spectrometry in forensic toxicology
    • Van Bocxlaer J.F., Clauwaert K.M., Lambert W.E., et al. Liquid chromatography-mass spectrometry in forensic toxicology. Mass Spectrom Rev 2000, 19:165-214.
    • (2000) Mass Spectrom Rev , vol.19 , pp. 165-214
    • Van Bocxlaer, J.F.1    Clauwaert, K.M.2    Lambert, W.E.3
  • 4
    • 59949099140 scopus 로고    scopus 로고
    • Mass spectrometry in newborn and metabolic screening: historical perspective and future directions
    • Chace D. Mass spectrometry in newborn and metabolic screening: historical perspective and future directions. J Mass Spectrom 2009, 44:163-170.
    • (2009) J Mass Spectrom , vol.44 , pp. 163-170
    • Chace, D.1
  • 5
    • 0027414682 scopus 로고
    • Mass spectrometry in the diagnosis of steroid related disorders and in hypertension research
    • Shackleton C.H. Mass spectrometry in the diagnosis of steroid related disorders and in hypertension research. J Steroid Biochem Mol Biol 1993, 45:127-140.
    • (1993) J Steroid Biochem Mol Biol , vol.45 , pp. 127-140
    • Shackleton, C.H.1
  • 6
    • 78650902308 scopus 로고    scopus 로고
    • Thyroid hormone testing by tandem mass spectrometry
    • Soldin O.P., Soldin S.J. Thyroid hormone testing by tandem mass spectrometry. Clin Biochem 2011, 44:89-94.
    • (2011) Clin Biochem , vol.44 , pp. 89-94
    • Soldin, O.P.1    Soldin, S.J.2
  • 7
    • 78650883356 scopus 로고    scopus 로고
    • Current status and future developments of LC-MS/MS in clinical chemistry for quantification of biogenic amines
    • de Jong W.H., de Vries E.G., Kema I.P. Current status and future developments of LC-MS/MS in clinical chemistry for quantification of biogenic amines. Clin Biochem 2011, 44:95-103.
    • (2011) Clin Biochem , vol.44 , pp. 95-103
    • de Jong, W.H.1    de Vries, E.G.2    Kema, I.P.3
  • 8
    • 33645459367 scopus 로고    scopus 로고
    • Analysis of methylmalonic acid in plasma by liquid chromatography-tandem mass spectrometry
    • Schmedes A., Brandslund I. Analysis of methylmalonic acid in plasma by liquid chromatography-tandem mass spectrometry. Clin Chem 2006, 52:754-757.
    • (2006) Clin Chem , vol.52 , pp. 754-757
    • Schmedes, A.1    Brandslund, I.2
  • 9
    • 0035241692 scopus 로고    scopus 로고
    • Mass spectrometry in the clinical laboratory
    • Chace D.H. Mass spectrometry in the clinical laboratory. Chem Rev 2001, 101:445-478.
    • (2001) Chem Rev , vol.101 , pp. 445-478
    • Chace, D.H.1
  • 10
    • 42449118906 scopus 로고    scopus 로고
    • Free thyroid hormones in serum by direct equilibrium dialysis and online solid-phase extraction-liquid chromatography/tandem mass spectrometry
    • Yue B., Rockwood A.L., Sandrock T., et al. Free thyroid hormones in serum by direct equilibrium dialysis and online solid-phase extraction-liquid chromatography/tandem mass spectrometry. Clin Chem 2008, 54:642-651.
    • (2008) Clin Chem , vol.54 , pp. 642-651
    • Yue, B.1    Rockwood, A.L.2    Sandrock, T.3
  • 11
    • 54149084920 scopus 로고    scopus 로고
    • The impact of assay quality and reference ranges on clinical decision making in the diagnosis of androgen disorders
    • Bhasin S., Zhang A., Coviello A., et al. The impact of assay quality and reference ranges on clinical decision making in the diagnosis of androgen disorders. Steroids 2008, 73:1311-1317.
    • (2008) Steroids , vol.73 , pp. 1311-1317
    • Bhasin, S.1    Zhang, A.2    Coviello, A.3
  • 12
    • 48949106598 scopus 로고    scopus 로고
    • State-of-the-art of serum testosterone measurement by isotope dilution-liquid chromatography-tandem mass spectrometry
    • Thienpont L.M., Van Uytfanghe K., Blincko S., et al. State-of-the-art of serum testosterone measurement by isotope dilution-liquid chromatography-tandem mass spectrometry. Clin Chem 2008, 54:1290-1297.
    • (2008) Clin Chem , vol.54 , pp. 1290-1297
    • Thienpont, L.M.1    Van Uytfanghe, K.2    Blincko, S.3
  • 13
    • 12944250918 scopus 로고    scopus 로고
    • Precisely wrong?. Urinary fractionated metanephrines and peer-based laboratory proficiency testing
    • discussion 473-4
    • Singh R.J., Grebe S.K., Yue B., et al. Precisely wrong?. Urinary fractionated metanephrines and peer-based laboratory proficiency testing. Clin Chem 2005, 51:472-473. discussion 473-4.
    • (2005) Clin Chem , vol.51 , pp. 472-473
    • Singh, R.J.1    Grebe, S.K.2    Yue, B.3
  • 16
    • 33747846300 scopus 로고    scopus 로고
    • Simultaneous determination of 12 steroids by isotope dilution liquid chromatography-photospray ionization tandem mass spectrometry
    • Guo T., Taylor R.L., Singh R.J., et al. Simultaneous determination of 12 steroids by isotope dilution liquid chromatography-photospray ionization tandem mass spectrometry. Clin Chim Acta 2006, 372:76-82.
    • (2006) Clin Chim Acta , vol.372 , pp. 76-82
    • Guo, T.1    Taylor, R.L.2    Singh, R.J.3
  • 17
    • 80052539443 scopus 로고    scopus 로고
    • LC-MS/MS in the Clinical Laboratory - Where to From Here?
    • Grebe S.K., Singh R.J. LC-MS/MS in the Clinical Laboratory - Where to From Here?. Clin Biochem Rev 2011, 32:5-31.
    • (2011) Clin Biochem Rev , vol.32 , pp. 5-31
    • Grebe, S.K.1    Singh, R.J.2
  • 18
    • 77955246441 scopus 로고    scopus 로고
    • Pitfalls associated with the use of liquid chromatography-tandem mass spectrometry in the clinical laboratory
    • Vogeser M., Seger C. Pitfalls associated with the use of liquid chromatography-tandem mass spectrometry in the clinical laboratory. Clin Chem 2010, 56:1234-1244.
    • (2010) Clin Chem , vol.56 , pp. 1234-1244
    • Vogeser, M.1    Seger, C.2
  • 19
    • 14844305229 scopus 로고    scopus 로고
    • Therapeutic drug monitoring of immunosuppressant drugs by high performance liquid chromatography-mass spectrometry
    • Taylor P.J. Therapeutic drug monitoring of immunosuppressant drugs by high performance liquid chromatography-mass spectrometry. Ther Drug Monit 2004, 26:215-219.
    • (2004) Ther Drug Monit , vol.26 , pp. 215-219
    • Taylor, P.J.1
  • 20
    • 54149101289 scopus 로고    scopus 로고
    • Potential role of ultra-sensitive estradiol assays in estimating the risk of breast cancer and fractures
    • Santen R.J., Lee J.S., Wang S., et al. Potential role of ultra-sensitive estradiol assays in estimating the risk of breast cancer and fractures. Steroids 2008, 73:1318-1321.
    • (2008) Steroids , vol.73 , pp. 1318-1321
    • Santen, R.J.1    Lee, J.S.2    Wang, S.3
  • 21
    • 77955414023 scopus 로고    scopus 로고
    • Advantages and challenges of mass spectrometry assays for steroid hormones
    • Stanczyk F.Z., Clarke N.J. Advantages and challenges of mass spectrometry assays for steroid hormones. J Steroid Biochem Mol Biol 2010, 121:491-495.
    • (2010) J Steroid Biochem Mol Biol , vol.121 , pp. 491-495
    • Stanczyk, F.Z.1    Clarke, N.J.2
  • 22
    • 78650864018 scopus 로고    scopus 로고
    • Liquid chromatography tandem mass spectrometry for analysis of steroids in clinical laboratories
    • Kushnir M.M., Rockwood A.L., Roberts W.L., et al. Liquid chromatography tandem mass spectrometry for analysis of steroids in clinical laboratories. Clin Biochem 2011, 44:77-88.
    • (2011) Clin Biochem , vol.44 , pp. 77-88
    • Kushnir, M.M.1    Rockwood, A.L.2    Roberts, W.L.3
  • 24
    • 14844286109 scopus 로고    scopus 로고
    • Assessing analytical specificity in quantitative analysis using tandem mass spectrometry
    • Kushnir M.M., Rockwood A.L., Nelson G.J. Assessing analytical specificity in quantitative analysis using tandem mass spectrometry. Clin Biochem 2005, 38;:319-327.
    • (2005) Clin Biochem , pp. 319-327
    • Kushnir, M.M.1    Rockwood, A.L.2    Nelson, G.J.3
  • 25
    • 0036153476 scopus 로고    scopus 로고
    • Analysis of catecholamines in urine by positive-ion electrospray tandem mass spectrometry
    • Kushnir M.M., Urry F.M., Frank E.L., et al. Analysis of catecholamines in urine by positive-ion electrospray tandem mass spectrometry. Clin Chem 2002, 48:323-331.
    • (2002) Clin Chem , vol.48 , pp. 323-331
    • Kushnir, M.M.1    Urry, F.M.2    Frank, E.L.3
  • 26
    • 42949129215 scopus 로고    scopus 로고
    • High-sensitivity tandem mass spectrometry assay for serum estrone and estradiol
    • Kushnir M.M., Rockwood A.L., Bergquist J. High-sensitivity tandem mass spectrometry assay for serum estrone and estradiol. Am J Clin Pathol 2008, 129:530-539.
    • (2008) Am J Clin Pathol , vol.129 , pp. 530-539
    • Kushnir, M.M.1    Rockwood, A.L.2    Bergquist, J.3
  • 27
    • 78650882617 scopus 로고    scopus 로고
    • Progress in automation of LC-MS in laboratory medicine
    • Vogeser M., Kirchoff F. Progress in automation of LC-MS in laboratory medicine. Clin Biochem 2011, 44:4-13.
    • (2011) Clin Biochem , vol.44 , pp. 4-13
    • Vogeser, M.1    Kirchoff, F.2
  • 28
    • 59249107194 scopus 로고    scopus 로고
    • Two new techniques for sample preparation in bioanalysis: microextraction in packed sorbent (MEPS) and use of a bonded monolith as sorbent for sample preparation in polypropylene tips for 96-well plates
    • Blomberg L.G. Two new techniques for sample preparation in bioanalysis: microextraction in packed sorbent (MEPS) and use of a bonded monolith as sorbent for sample preparation in polypropylene tips for 96-well plates. Anal Bioanal Chem 2009, 393:797-807.
    • (2009) Anal Bioanal Chem , vol.393 , pp. 797-807
    • Blomberg, L.G.1
  • 29
    • 34548356575 scopus 로고    scopus 로고
    • Plasma free metanephrine measurement using automated online solid phase extraction HPLC-tandem mass spectrometry
    • De Jong W.H.A., Graham K.S., van der Molen J.C. Plasma free metanephrine measurement using automated online solid phase extraction HPLC-tandem mass spectrometry. Clin Chem 2007, 53:1684-1693.
    • (2007) Clin Chem , vol.53 , pp. 1684-1693
    • De Jong, W.H.A.1    Graham, K.S.2    van der Molen, J.C.3
  • 31
    • 33746413029 scopus 로고    scopus 로고
    • Automated, fast and sensitive quantification of 17alpha-hydroxyprogesterone, androstenedione, and testosterone by tandem mass spectrometry with online extraction
    • Rauh M., Groschl M., Rascher W., et al. Automated, fast and sensitive quantification of 17alpha-hydroxyprogesterone, androstenedione, and testosterone by tandem mass spectrometry with online extraction. Steroids 2006, 71:450-458.
    • (2006) Steroids , vol.71 , pp. 450-458
    • Rauh, M.1    Groschl, M.2    Rascher, W.3
  • 32
    • 67650747270 scopus 로고    scopus 로고
    • Automated method for the direct analysis of 8-oxo-guanosine and 8-oxo-2'-deoxyguanosine in human urine using ultraperformance liquid chromatography and tandem mass spectrometry
    • Henriksen T., Hellestrom P.R., Poulsen H.E., et al. Automated method for the direct analysis of 8-oxo-guanosine and 8-oxo-2'-deoxyguanosine in human urine using ultraperformance liquid chromatography and tandem mass spectrometry. Free Radic Biol Med 2009, 47:629-635.
    • (2009) Free Radic Biol Med , vol.47 , pp. 629-635
    • Henriksen, T.1    Hellestrom, P.R.2    Poulsen, H.E.3
  • 33
    • 34248170735 scopus 로고    scopus 로고
    • A simple high-throughput method for the determination of plasma methylmalonic acid by liquid chromatography-tandem mass spectrometry
    • Blom H.J., van Rooij A., Hogeveen M. A simple high-throughput method for the determination of plasma methylmalonic acid by liquid chromatography-tandem mass spectrometry. Clin Chem Lab Med 2007, 45:645-650.
    • (2007) Clin Chem Lab Med , vol.45 , pp. 645-650
    • Blom, H.J.1    van Rooij, A.2    Hogeveen, M.3
  • 34
    • 53149143498 scopus 로고    scopus 로고
    • Automated solid-phase extraction for concentration and clean-up of female steroid hormones prior to liquid chromatography-electrospray ionization-tandem mass spectrometry: an approach to lipidomics
    • Alvarez Sánchez B., Capote F.P., Jiménez J.R., et al. Automated solid-phase extraction for concentration and clean-up of female steroid hormones prior to liquid chromatography-electrospray ionization-tandem mass spectrometry: an approach to lipidomics. J Chromatogr A 2008, 1207:46-54.
    • (2008) J Chromatogr A , vol.1207 , pp. 46-54
    • Alvarez Sánchez, B.1    Capote, F.P.2    Jiménez, J.R.3
  • 35
    • 0032986050 scopus 로고    scopus 로고
    • The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds
    • Bonfiglio R., King R.C., Olah T.V., et al. The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds. Rapid Commun Mass Spectrom 1999, 13:1175-1185.
    • (1999) Rapid Commun Mass Spectrom , vol.13 , pp. 1175-1185
    • Bonfiglio, R.1    King, R.C.2    Olah, T.V.3
  • 37
    • 77952102785 scopus 로고    scopus 로고
    • A rubber transfer gasket to improve the throughput of liquid-liquid extraction in 96 well plates: application to vitamin D testing
    • Hoofnagle A.N., Laha T.J., Donaldson T.F. A rubber transfer gasket to improve the throughput of liquid-liquid extraction in 96 well plates: application to vitamin D testing. J Chromogr B Analyt Technol Biomed Life Sci 2010, 878:1639-1642.
    • (2010) J Chromogr B Analyt Technol Biomed Life Sci , vol.878 , pp. 1639-1642
    • Hoofnagle, A.N.1    Laha, T.J.2    Donaldson, T.F.3
  • 39
    • 77950348819 scopus 로고    scopus 로고
    • Quantitation of 17-OH-progesterone (OHPG) for diagnosis of congenital adrenal hyperplasia (CAH)
    • Singh R.J. Quantitation of 17-OH-progesterone (OHPG) for diagnosis of congenital adrenal hyperplasia (CAH). Methods Mol Biol 2010, 603:271-277.
    • (2010) Methods Mol Biol , vol.603 , pp. 271-277
    • Singh, R.J.1
  • 40
    • 77952801705 scopus 로고    scopus 로고
    • Liquid chromatography-tandem mass spectrometry applications in endocrinology
    • Kushnir M.M., Rockwood A.L., Bergquist J. Liquid chromatography-tandem mass spectrometry applications in endocrinology. Mass Spectrom Rev 2010, 29:480-502.
    • (2010) Mass Spectrom Rev , vol.29 , pp. 480-502
    • Kushnir, M.M.1    Rockwood, A.L.2    Bergquist, J.3
  • 42
    • 68849083050 scopus 로고    scopus 로고
    • Integrated, nontargeted ultrahigh performance liquid chromatography/electrospray ionization tandem mass spectrometry platform for the identification and relative quantification of the small-molecule complement of biological systems
    • Evans A.M., DeHaven C.D., Barrett T., et al. Integrated, nontargeted ultrahigh performance liquid chromatography/electrospray ionization tandem mass spectrometry platform for the identification and relative quantification of the small-molecule complement of biological systems. Anal Chem 2009, 81:6656-6667.
    • (2009) Anal Chem , vol.81 , pp. 6656-6667
    • Evans, A.M.1    DeHaven, C.D.2    Barrett, T.3
  • 43
    • 54349107828 scopus 로고    scopus 로고
    • Validation of a high throughput method for serum/plasma testosterone using liquid chromatography tandem mass spectrometry (LC-MS/MS)
    • Singh R.J. Validation of a high throughput method for serum/plasma testosterone using liquid chromatography tandem mass spectrometry (LC-MS/MS). Steroids 2008, 73:1339-1344.
    • (2008) Steroids , vol.73 , pp. 1339-1344
    • Singh, R.J.1
  • 44
    • 0031569131 scopus 로고    scopus 로고
    • Ultrahigh-pressure reversed-phase liquid chromatography in packed capillary columns
    • MacNair J.E., Lewis K.C., Jorgenson J.W. Ultrahigh-pressure reversed-phase liquid chromatography in packed capillary columns. Anal Chem 1997, 69:983-989.
    • (1997) Anal Chem , vol.69 , pp. 983-989
    • MacNair, J.E.1    Lewis, K.C.2    Jorgenson, J.W.3
  • 45
    • 77955735445 scopus 로고    scopus 로고
    • Emerging analytical separation techniques with high throughput potential for pharmaceutical analysis, part I: Stationary phase and instrumental developments in LC
    • Review
    • Pieters S., Dejaegher B., Vander Heyden Y. Emerging analytical separation techniques with high throughput potential for pharmaceutical analysis, part I: Stationary phase and instrumental developments in LC. Comb Chem High Throughput Screen 2010, 13:510-529. Review.
    • (2010) Comb Chem High Throughput Screen , vol.13 , pp. 510-529
    • Pieters, S.1    Dejaegher, B.2    Vander Heyden, Y.3
  • 46
    • 79952230012 scopus 로고    scopus 로고
    • Increasing liquid chromatography-tandem mass spectrometry throughput by mass tagging: a sample-multiplexed high-throughput assay for 25-hydroxyvitamin D2 and D3
    • Netzel B.C., Cradic K.W., Bro E.T., et al. Increasing liquid chromatography-tandem mass spectrometry throughput by mass tagging: a sample-multiplexed high-throughput assay for 25-hydroxyvitamin D2 and D3. Clin Chem 2011, 57:431-440.
    • (2011) Clin Chem , vol.57 , pp. 431-440
    • Netzel, B.C.1    Cradic, K.W.2    Bro, E.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.