메뉴 건너뛰기




Volumn 38, Issue 9, 2011, Pages 5049-5057

Measuring signal-to-noise ratio in partially parallel imaging MRI

Author keywords

GRAPPA; MRI; mSENSE; partially parallel imaging; SNR

Indexed keywords

BIOMEDICAL SIGNAL PROCESSING; ENCODING (SYMBOLS); MAGNETIC RESONANCE IMAGING; SIGNAL ENCODING;

EID: 80052421229     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3618730     Document Type: Article
Times cited : (125)

References (28)
  • 1
    • 80052416100 scopus 로고    scopus 로고
    • American College of Radiology, (American College of Radiology, Reston, VA)
    • American College of Radiology, Magnetic Resonance Imaging Quality Control Manual. (American College of Radiology, Reston, VA, 2004).
    • (2004) Magnetic Resonance Imaging Quality Control Manual
  • 2
    • 0021948756 scopus 로고
    • Measurement of signal intensities in the presence of noise in MR images
    • 10.1118/1.595711
    • R. M. Henkelman, Measurement of signal intensities in the presence of noise in MR images., Med. Phys. 12, 232-233 (1985). 10.1118/1.595711
    • (1985) Med. Phys. , vol.12 , pp. 232-233
    • Henkelman, R.M.1
  • 3
    • 0028839871 scopus 로고
    • The Rician distribution of noisy MRI data
    • 10.1002/mrm.v34:6
    • H. Gudbjartsson and S. Patz, The Rician distribution of noisy MRI data., Magn. Reson. Med. 34, 910-914 (1995). 10.1002/mrm.v34:6
    • (1995) Magn. Reson. Med. , vol.34 , pp. 910-914
    • Gudbjartsson, H.1    Patz, S.2
  • 5
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • 10.1002/mrm.v38:4
    • D. K. Sodickson and W. J. Manning, Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays., Magn. Reson. Med. 38, 591-603 (1997). 10.1002/mrm.v38:4
    • (1997) Magn. Reson. Med. , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 6
    • 0032712873 scopus 로고    scopus 로고
    • SENSE: Sensitivity encoding for fast MRI
    • 10.1002/(SICI)1522-2594(199911)42:51.0.CO;2-O
    • K. P. Pruessmann, M. Weiger, M. B. Scheidegger, and P. Boesiger, SENSE: Sensitivity encoding for fast MRI., Magn. Reson. Med. 42, 952-962 (1999). 10.1002/(SICI)1522-2594(199911)42:51.0.CO;2-O
    • (1999) Magn. Reson. Med. , vol.42 , pp. 952-962
    • Pruessmann, K.P.1    Weiger, M.2    Scheidegger, M.B.3    Boesiger, P.4
  • 7
    • 0030726766 scopus 로고    scopus 로고
    • Signal-to-noise measurements in magnitude images from NMR phased arrays
    • 10.1002/mrm.v38:5
    • C. D. Constantinides, E. Atalar, and E. R. McVeigh, Signal-to-noise measurements in magnitude images from NMR phased arrays., Magn. Reson. Med. 38, 852-857 (1997). 10.1002/mrm.v38:5
    • (1997) Magn. Reson. Med. , vol.38 , pp. 852-857
    • Constantinides, C.D.1    Atalar, E.2    McVeigh, E.R.3
  • 8
    • 34547879249 scopus 로고    scopus 로고
    • Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters
    • 10.1002/jmri.v26:2
    • O. Dietrich, J. G. Raya, S. B. Reeder, M. F. Reiser, and S. O. Schoenberg, Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters., J. Magn. Reson. Imaging 26, 375-385 (2007). 10.1002/jmri.v26:2
    • (2007) J. Magn. Reson. Imaging , vol.26 , pp. 375-385
    • Dietrich, O.1    Raya, J.G.2    Reeder, S.B.3    Reiser, M.F.4    Schoenberg, S.O.5
  • 12
    • 24144470505 scopus 로고    scopus 로고
    • Practical approaches to the evaluation of signal-to-noise ratio performance with parallel imaging: Application with cardiac imaging and a 32-channel cardiac coil
    • 10.1002/mrm.v54:3
    • S. B. Reeder, B. J. Wintersperger, O. Dietrich, T. Lanz, A. Greiser, M. F. Reiser, G. M. Glazer, and S. O. Schoenberg, Practical approaches to the evaluation of signal-to-noise ratio performance with parallel imaging: Application with cardiac imaging and a 32-channel cardiac coil., Magn. Reson. Med. 54, 748-754 (2005). 10.1002/mrm.v54:3
    • (2005) Magn. Reson. Med. , vol.54 , pp. 748-754
    • Reeder, S.B.1    Wintersperger, B.J.2    Dietrich, O.3    Lanz, T.4    Greiser, A.5    Reiser, M.F.6    Glazer, G.M.7    Schoenberg, S.O.8
  • 13
    • 53549094426 scopus 로고    scopus 로고
    • Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions
    • 10.1002/mrm.21728
    • P. M. Robson, A. K. Grant, A. J. Madhuranthakam, R. Lattanzi, D. K. Sodickson, and C. A. McKenzie, Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions., Magn. Reson. Med. 60, 895-907 (2008). 10.1002/mrm.21728
    • (2008) Magn. Reson. Med. , vol.60 , pp. 895-907
    • Robson, P.M.1    Grant, A.K.2    Madhuranthakam, A.J.3    Lattanzi, R.4    Sodickson, D.K.5    McKenzie, C.A.6
  • 15
    • 27644527486 scopus 로고    scopus 로고
    • Image reconstruction in SNR units: A general method for SNR measurement
    • 10.1002/mrm.v54:6
    • P. Kellman and E. R. McVeigh, Image reconstruction in SNR units: A general method for SNR measurement., Magn. Reson. Med. 54, 1439-1447 (2005). 10.1002/mrm.v54:6
    • (2005) Magn. Reson. Med. , vol.54 , pp. 1439-1447
    • Kellman, P.1    McVeigh, E.R.2
  • 16
    • 85027224044 scopus 로고    scopus 로고
    • AAPM TG #118 (Personal Correspondence)
    • AAPM TG #118 (Personal Correspondence, 2009).
    • (2009)
  • 18
    • 84944485718 scopus 로고
    • Mathematical analysis of random noise
    • S. Rice, Mathematical analysis of random noise., Bell Syst. Tech. J. 24, 46-156 (1945).
    • (1945) Bell Syst. Tech. J. , vol.24 , pp. 46-156
    • Rice, S.1
  • 19
    • 0027318510 scopus 로고
    • Signal-to-noise measures for magnetic resonance imagers
    • 10.1016/0730-725X(93)90076-P
    • B. Murphy, P. Carson, J. Ellis, Y. Zhang, R. Hyde, and T. Chenevert, Signal-to-noise measures for magnetic resonance imagers., Magn. Reson. Imag. 11, 425-428 (1993). 10.1016/0730-725X(93)90076-P
    • (1993) Magn. Reson. Imag. , vol.11 , pp. 425-428
    • Murphy, B.1    Carson, P.2    Ellis, J.3    Zhang, Y.4    Hyde, R.5    Chenevert, T.6
  • 21
    • 0032800940 scopus 로고    scopus 로고
    • A comparison of two methods for measuring the signal to noise ratio on MR images
    • 10.1088/0031-9155/44/12/403
    • M. J. Firbank, A. Coulthard, R. M. Harrison, and E. D. Williams, A comparison of two methods for measuring the signal to noise ratio on MR images., Phys. Med. Biol. 44, N261-N264 (1999). 10.1088/0031-9155/44/12/403
    • (1999) Phys. Med. Biol. , vol.44
    • Firbank, M.J.1    Coulthard, A.2    Harrison, R.M.3    Williams, E.D.4
  • 24
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • 10.1016/S0140-6736(86)90837-8
    • J. M. Bland and D. G. Altman, Statistical methods for assessing agreement between two methods of clinical measurement., Lancet 1, 307-310 (1986). 10.1016/S0140-6736(86)90837-8
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 25
    • 0028791287 scopus 로고
    • Comparing methods of measurement: Why plotting difference against standard method is misleading
    • 10.1016/S0140-6736(95)91748-9
    • J. M. Bland and D. G. Altman, Comparing methods of measurement: Why plotting difference against standard method is misleading., Lancet 346, 1085-1087 (1995). 10.1016/S0140-6736(95)91748-9
    • (1995) Lancet , vol.346 , pp. 1085-1087
    • Bland, J.M.1    Altman, D.G.2
  • 26
    • 33744528646 scopus 로고    scopus 로고
    • An introduction to coil array design for parallel MRI
    • 10.1002/nbm.v19:3
    • M. A. Ohliger and D. K. Sodickson, An introduction to coil array design for parallel MRI., NMR Biomed. 19, 300-315 (2006). 10.1002/nbm.v19:3
    • (2006) NMR Biomed. , vol.19 , pp. 300-315
    • Ohliger, M.A.1    Sodickson, D.K.2
  • 28
    • 30344457025 scopus 로고    scopus 로고
    • Beyond the g-factor limit in sensitivity encoding using joint histogram entropy
    • 10.1002/mrm.v55:1
    • D. J. Larkman, P. G. Batchelor, D. Atkinson, D. Rueckert, and J. V. Hajnal, Beyond the g-factor limit in sensitivity encoding using joint histogram entropy., Magn. Reson. Med. 55, 153-160 (2006). 10.1002/mrm.v55:1
    • (2006) Magn. Reson. Med. , vol.55 , pp. 153-160
    • Larkman, D.J.1    Batchelor, P.G.2    Atkinson, D.3    Rueckert, D.4    Hajnal, J.V.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.