메뉴 건너뛰기




Volumn 106, Issue 3, 2011, Pages 191-197

Marginal accuracy and internal fit of machine-milled and cast titanium crowns

Author keywords

[No Author keywords available]

Indexed keywords

TITANIUM;

EID: 80052348005     PISSN: 00223913     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0022-3913(11)60120-0     Document Type: Article
Times cited : (45)

References (28)
  • 2
    • 0026845341 scopus 로고
    • Marginal accuracy and geometry of cast titanium copings
    • R Blackman, R Baez, N Barghi Marginal accuracy and geometry of cast titanium copings J Prosthet Dent 67 1992 435 440
    • (1992) J Prosthet Dent , vol.67 , pp. 435-440
    • Blackman, R.1    Baez, R.2    Barghi, N.3
  • 4
    • 0034146787 scopus 로고    scopus 로고
    • Fit of titanium and a base metal alloy metal-ceramic crown
    • S Oru, Y Tulunoglu Fit of titanium and a base metal alloy metal-ceramic crown J Prosthet Dent 83 2000 314 318
    • (2000) J Prosthet Dent , vol.83 , pp. 314-318
    • Oru, S.1    Tulunoglu, Y.2
  • 5
    • 0030155746 scopus 로고    scopus 로고
    • Titanium for prosthodontic applications: A review of the literature
    • RR Wang, A Fenton Titanium for prosthodontic applications: a review of the literature Quintessence Int 27 1996 401 408 (Pubitemid 126699279)
    • (1996) Quintessence International , vol.27 , Issue.6 , pp. 401-408
    • Wang, R.R.1    Fenton, A.2
  • 6
    • 0026235142 scopus 로고
    • Quality criteria for pure titanium casting, laboratory soldering, intraoral welding, and a device to aid in making uncontaminated castings
    • AR Hruska, P Borelli Quality criteria for pure titanium casting, laboratory soldering, intraoral welding, and a device to aid in making uncontaminated castings J Prosthet Dent 66 1991 561 565
    • (1991) J Prosthet Dent , vol.66 , pp. 561-565
    • Hruska, A.R.1    Borelli, P.2
  • 7
    • 0029382149 scopus 로고
    • Casting of TI-6AI-4V alloy compared with pure Ti in an Ar-arc casting machine
    • M Syverud, T Okabe, H Herø Casting of TI-6AI-4V alloy compared with pure Ti in an Ar-arc casting machine Eur J Oral Sci 103 1995 327 330
    • (1995) Eur J Oral Sci , vol.103 , pp. 327-330
    • Syverud, M.1    Okabe, T.2    Herø, H.3
  • 8
    • 33947528699 scopus 로고    scopus 로고
    • The effects of different types of investments on the alpha-case layer of titanium castings
    • Y Guilin, L Nan, L Yousheng, W Yining The effects of different types of investments on the alpha-case layer of titanium castings J Prosthet Dent 97 2007 157 164
    • (2007) J Prosthet Dent , vol.97 , pp. 157-164
    • Guilin, Y.1    Nan, L.2    Yousheng, L.3    Yining, W.4
  • 10
    • 33746383047 scopus 로고    scopus 로고
    • Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques
    • DOI 10.1016/j.prosdent.2006.05.013, PII S0022391306002757
    • S Witkowski, F Komine, T Gerds Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques J Prosthet Dent 96 2006 47 52 (Pubitemid 44109708)
    • (2006) Journal of Prosthetic Dentistry , vol.96 , Issue.1 , pp. 47-52
    • Witkowski, S.1    Komine, F.2    Gerds, T.3
  • 11
  • 12
    • 84985807754 scopus 로고
    • Gingival and alveolar bone reaction to marginal fit of subgingival crown margins
    • SE Sorensen, IB Larsen, KD Jörgensen Gingival and alveolar bone reaction to marginal fit of subgingival crown margins Scand J Dent Res 94 1986 109 114
    • (1986) Scand J Dent Res , vol.94 , pp. 109-114
    • Sorensen, S.E.1    Larsen, I.B.2    Jörgensen, K.D.3
  • 13
    • 0019529835 scopus 로고
    • The effect of various finish line preparations on the marginal seal and occlusal seat of full crown preparations
    • JR Gavelis, JD Morency, ED Riley, RB Sozio The effect of various finish line preparations on the marginal seal and occlusal seat of full crown preparations J Prosthet Dent 45 1981 138 145
    • (1981) J Prosthet Dent , vol.45 , pp. 138-145
    • Gavelis, J.R.1    Morency, J.D.2    Riley, E.D.3    Sozio, R.B.4
  • 14
    • 0026127801 scopus 로고
    • An investigation of dental luting cement solubility as a function of the marginal gap
    • MS Jacobs, AS Windeler An investigation of dental luting cement solubility as a function of the marginal gap J Prosthet Dent 65 1991 436 442
    • (1991) J Prosthet Dent , vol.65 , pp. 436-442
    • Jacobs, M.S.1    Windeler, A.S.2
  • 15
    • 0025684903 scopus 로고
    • Gingival margins for crowns: A review and discussion. Part II: Discrepancies and configurations
    • AJ Hunter, AR Hunter Gingival margins for crowns: a review and discussion. Part II: Discrepancies and configurations J Prosthet Dent 64 1990 636 642
    • (1990) J Prosthet Dent , vol.64 , pp. 636-642
    • Hunter, A.J.1    Hunter, A.R.2
  • 16
    • 0015209415 scopus 로고
    • The estimation of cement film thickness by an in vivo technique
    • JW McLean, JA von Fraunhofer The estimation of cement film thickness by an in vivo technique Br Dent J 131 1971 107 111
    • (1971) Br Dent J , vol.131 , pp. 107-111
    • McLean, J.W.1    Von Fraunhofer, J.A.2
  • 17
    • 0038488528 scopus 로고    scopus 로고
    • Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible
    • A Ortorp, T Jemt, T Back, T Jälevik Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible Int J Prosthodont 16 2003 194 200 (Pubitemid 37162376)
    • (2003) International Journal of Prosthodontics , vol.16 , Issue.2 , pp. 194-200
    • Ortorp, A.1    Jemt, T.2    Back, T.3    Jalevik, T.4
  • 18
    • 0043130461 scopus 로고    scopus 로고
    • Stress-relieving and porcelain firing cycle influence on marginal fit of commercially pure titanium and titanium aluminum vanadium copings
    • JC Fonseca, GE Henriques, LC Sobrinho, MF de Góes Stress-relieving and porcelain firing cycle influence on marginal fit of commercially pure titanium and titanium aluminum vanadium copings Dent Mater 19 2003 686 691
    • (2003) Dent Mater , vol.19 , pp. 686-691
    • Fonseca, J.C.1    Henriques, G.E.2    Sobrinho, L.C.3    De Góes, M.F.4
  • 19
    • 0035258727 scopus 로고    scopus 로고
    • Evaluation of high-temperature distortion of high-palladium metal-ceramic crowns
    • DOI 10.1067/mpr.2001.113707
    • E Papazoglou, WA Brantley, WM Johnston Evaluation of high-temperature distortion of high-palladium metal-ceramic crowns J Prosthet Dent 85 2001 133 140 (Pubitemid 33642442)
    • (2001) Journal of Prosthetic Dentistry , vol.85 , Issue.2 , pp. 133-140
    • Papazoglou, E.1    Brantley, W.A.2    Johnston, W.M.3
  • 20
    • 47249089599 scopus 로고    scopus 로고
    • An in vitro comparison of vertical marginal gaps of CAD/CAM titanium and conventional cast restorations
    • PL Tan, DG Gratton, AM Diaz-Arnold, DC Holmes An in vitro comparison of vertical marginal gaps of CAD/CAM titanium and conventional cast restorations J Prosthodont 17 2008 378 383
    • (2008) J Prosthodont , vol.17 , pp. 378-383
    • Tan, P.L.1    Gratton, D.G.2    Diaz-Arnold, A.M.3    Holmes, D.C.4
  • 21
    • 0020144920 scopus 로고
    • Measurement of paint-on die spacers used for casting relief
    • MV Campagni, JD Preston, MH Reisbick Measurement of paint-on die spacers used for casting relief J Prosthet Dent 47 1982 606 611
    • (1982) J Prosthet Dent , vol.47 , pp. 606-611
    • Campagni, M.V.1    Preston, J.D.2    Reisbick, M.H.3
  • 22
    • 73149084160 scopus 로고    scopus 로고
    • Effect of metal selection and porcelain firing on the marginal accuracy of titanium-based metal ceramic restorations
    • TE Shokry, M Attia, I Mosleh, M Elhosary, T Hamza, C Shen Effect of metal selection and porcelain firing on the marginal accuracy of titanium-based metal ceramic restorations J Prosthet Dent 103 2010 45 52
    • (2010) J Prosthet Dent , vol.103 , pp. 45-52
    • Shokry, T.E.1    Attia, M.2    Mosleh, I.3    Elhosary, M.4    Hamza, T.5    Shen, C.6
  • 23
    • 0027142077 scopus 로고
    • Mold filling and porosity in castings of titanium
    • H Herø, M Syverud, M Waarli Mold filling and porosity in castings of titanium Dent Mater 9 1993 15 18
    • (1993) Dent Mater , vol.9 , pp. 15-18
    • Herø, H.1    Syverud, M.2    Waarli, M.3
  • 24
    • 48749087870 scopus 로고    scopus 로고
    • Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology
    • K Quante, K Ludwig, M Kern Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology Dent Mater 24 2008 1311 1315
    • (2008) Dent Mater , vol.24 , pp. 1311-1315
    • Quante, K.1    Ludwig, K.2    Kern, M.3
  • 25
    • 37648999428 scopus 로고    scopus 로고
    • Resistance to dislodgement of zirconiacopings cemented onto titanium abutments of different heights
    • B Abbo, ME Razzoog, J Vivas, M Sierraalta Resistance to dislodgement of zirconiacopings cemented onto titanium abutments of different heights J Prosthet Dent 99 2008 25 29
    • (2008) J Prosthet Dent , vol.99 , pp. 25-29
    • Abbo, B.1    Razzoog, M.E.2    Vivas, J.3    Sierraalta, M.4
  • 28
    • 2342646870 scopus 로고    scopus 로고
    • A clinical evaluation of the agar alginate combined impression: Dimensional accuracy of dies by new master crown technique
    • PM Ratnaweera, K Yoshida, H Miura, A Kohta, K Tsuchihira A clinical evaluation of the agar alginate combined impression: dimensional accuracy of dies by new master crown technique J Med Dent Sci 50 2003 231 238 (Pubitemid 41114808)
    • (2003) Journal of Medical and Dental Sciences , vol.50 , Issue.3 , pp. 231-238
    • Ratnaweera, P.M.1    Yoshida, K.2    Miura, H.3    Kohta, A.4    Tsuchihira, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.