메뉴 건너뛰기




Volumn 159, Issue 1, 2011, Pages 307-313

Microfluidic chips for capillary electrophoresis with integrated electrodes for capacitively coupled conductivity detection based on printed circuit board technology

Author keywords

Capacitively coupled contactless conductivity detection (C4D); Capillary electrophoresis; Dry film photoresist; Integrated electrodes; Lab on a Chip; Microfluidic; Printed circuit board

Indexed keywords

ADVANCED TECHNOLOGY; CAPACITIVELY COUPLED; CAPACITIVELY COUPLED CONTACTLESS CONDUCTIVITY DETECTION; CONDUCTIVITY DETECTION; DETECTION ELECTRODE; DRY-FILM PHOTORESISTS; FIELD STRENGTHS; HYBRID DEVICES; INORGANIC CATIONS; INSULATING FILM; INTEGRATED DETECTORS; INTEGRATED ELECTRODES; LAB ON A CHIP; LAB-ON-A-CHIP DEVICES; MASS PRODUCTION; MICROFABRICATION METHODS; MICROFLUIDIC CHIP; MICROFLUIDIC NETWORKS; POLYDIMETHYLSILOXANE PDMS; PRINTED CIRCUIT BOARD TECHNOLOGY; SMOOTH SURFACE;

EID: 80052304665     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2011.06.023     Document Type: Article
Times cited : (54)

References (33)
  • 1
    • 0025207507 scopus 로고
    • Miniaturized total chemical analysis systems. A novel concept for chemical sensing
    • A. Manz, N. Graber, and H.M. Widmer Miniaturized total chemical-analysis systems - a novel concept for chemical sensing Sens. Actuator B - Chem. 1 1990 244 248 (Pubitemid 20699475)
    • (1990) Sensors and Actuators, B: Chemical , vol.B1 , Issue.1-6 , pp. 244-248
    • Manz, A.1    Graber, N.2    Widmer, H.M.3
  • 2
    • 1942426483 scopus 로고    scopus 로고
    • Chip vision - Optics for microchips
    • E. Verpoorte Chip vision - optics for microchips Lab Chip 3 2003 42N 52N
    • (2003) Lab Chip , vol.3
    • Verpoorte, E.1
  • 4
    • 0035805375 scopus 로고    scopus 로고
    • Isotachophoresis and isotachophoresis - Zone electrophoresis separations of inorganic anions present in water samples on a planar chip with column-coupling separation channels and conductivity detection
    • DOI 10.1016/S0021-9673(00)01080-3, PII S0021967300010803
    • R. Bodor, V. Madajova, D. Kaniansky, M. Masár, M. Johnck, and B. Stanislawski Isotachophoresis and isotachophoresis - zone electrophoresis separations of inorganic anions present in water samples on a planar chip with column-coupling separation channels and conductivity detection J. Chromatogr. A 916 2001 155 165 (Pubitemid 32373244)
    • (2001) Journal of Chromatography A , vol.916 , Issue.1-2 , pp. 155-165
    • Bodor, R.1    Madajova, V.2    Kaniansky, D.3    Masar, M.4    Johnck, M.5    Stanislawski, B.6
  • 8
    • 0036863537 scopus 로고    scopus 로고
    • A microchip electrophoresis system with integrated in-plane electrodes for contactless conductivity detection
    • DOI 10.1002/1522-2683(200211)23:21<3769::AID-ELPS3769>3.0.CO;2-E
    • J. Lichtenberg, N.F. de Rooij, and E. Verpoorte A microchip electrophoresis system with integrated in-plane electrodes for contactless conductivity detection Electrophoresis 23 2002 3769 3780 (Pubitemid 35469561)
    • (2002) Electrophoresis , vol.23 , Issue.21 , pp. 3769-3780
    • Lichtenberg, J.1    De Rooij, N.F.2    Verpoorte, E.3
  • 9
    • 0036558164 scopus 로고    scopus 로고
    • Contactless conductivity detector for microchip capillary electrophoresis
    • DOI 10.1021/ac011219e
    • M. Pumera, J. Wang, F. Opekar, I. Jelínek, J. Feldman, H. Löwe, and S. Hardt Contactless conductivity detector for microchip capillary electrophoresis Anal. Chem. 74 2002 1968 1971 (Pubitemid 34465389)
    • (2002) Analytical Chemistry , vol.74 , Issue.9 , pp. 1968-1971
    • Pumera, M.1    Wang, J.2    Opekar, F.3    Jelinek, I.4    Feldman, J.5    Lowe, H.6    Hardt, S.7
  • 10
    • 12144273188 scopus 로고    scopus 로고
    • Conductivity detection for conventional and miniaturised capillary electrophoresis systems
    • DOI 10.1002/elps.200406156
    • R.M. Guijt, C.J. Evenhuis, M. Macka, and P.R. Haddad Conductivity detection for conventional and miniaturised capillary electrophoresis systems Electrophoresis 25 2004 4032 4057 (Pubitemid 40104141)
    • (2004) Electrophoresis , vol.25 , Issue.23-24 , pp. 4032-4057
    • Guijt, R.M.1    Evenhuis, C.J.2    Macka, M.3    Haddad, P.R.4
  • 11
    • 11444250095 scopus 로고    scopus 로고
    • Contactless conductivity detection in capillary electrophoresis: A review
    • DOI 10.1002/elan.200403125
    • P. Kubáň, and P.C. Hauser Contactless conductivity detection in capillary electrophoresis: a review Electroanalysis 16 2004 2009 2021 (Pubitemid 40083000)
    • (2004) Electroanalysis , vol.16 , Issue.24 , pp. 2009-2021
    • Kuban, P.1    Hauser, P.C.2
  • 12
    • 37449034019 scopus 로고    scopus 로고
    • A review of the recent achievements in capacitively coupled contactless conductivity detection
    • DOI 10.1016/j.aca.2007.11.045, PII S0003267007019587
    • P. Kubáň, and P.C. Hauser A review of the recent achievements in capacitively coupled contactless conductivity detection Anal. Chim. Acta 607 2008 15 29 (Pubitemid 50012737)
    • (2008) Analytica Chimica Acta , vol.607 , Issue.1 , pp. 15-29
    • Kuban, P.1    Hauser, P.C.2
  • 13
    • 60949109716 scopus 로고    scopus 로고
    • Ten years of axial capacitively coupled contactless conductivity detection for CZE - A review
    • P. Kubáň, and P.C. Hauser Ten years of axial capacitively coupled contactless conductivity detection for CZE - a review Electrophoresis 30 2009 176 188
    • (2009) Electrophoresis , vol.30 , pp. 176-188
    • Kubáň, P.1    Hauser, P.C.2
  • 15
    • 80052324388 scopus 로고    scopus 로고
    • MicrofluidicChipShop
    • MicrofluidicChipShop, Lab-on-a-Chip Catalogue in, 2010.
    • (2010) Lab-on-a-Chip Catalogue
  • 18
    • 0036894426 scopus 로고    scopus 로고
    • Measurements of chemical warfare agent degradation products using an electrophoresis microchip with contactless conductivity detector
    • DOI 10.1021/ac025746p
    • J. Wang, M. Pumera, G.E. Collins, and A. Mulchandani Measurements of chemical warfare agent degradation products using an electrophoresis microchip with contactless conductivity Anal. Chem. 74 2002 6121 6125 (Pubitemid 35423922)
    • (2002) Analytical Chemistry , vol.74 , Issue.23 , pp. 6121-6125
    • Wang, J.1    Pumera, M.2    Collins, G.E.3    Mulchandani, A.4
  • 19
    • 0035251495 scopus 로고    scopus 로고
    • Miniature valveless pumps based on printed circuit board technique
    • DOI 10.1016/S0924-4247(00)00500-8
    • N.-T. Nguyen, and X. Huang Miniature valveless pumps based on printed circuit board technique Sens. Actuators A: Phys. 88 2001 104 111 (Pubitemid 32227208)
    • (2001) Sensors and Actuators, A: Physical , vol.88 , Issue.2 , pp. 104-111
    • Nguyen, N.-T.1    Huang, X.2
  • 20
    • 55949109118 scopus 로고    scopus 로고
    • Determination of gamma-hydroxybutyric acid in clinical samples using capillary electrophoresis with contactless conductivity detection
    • X.Y. Gong, P. Kubáň, A. Scholer, and P.C. Hauser Determination of gamma-hydroxybutyric acid in clinical samples using capillary electrophoresis with contactless conductivity detection J. Chromatogr. A 1213 2008 100 104
    • (2008) J. Chromatogr. A , vol.1213 , pp. 100-104
    • Gong, X.Y.1    Kubáň, P.2    Scholer, A.3    Hauser, P.C.4
  • 21
    • 33644836376 scopus 로고    scopus 로고
    • Integrated microfluidic UV absorbance detector with attomol-level sensitivity for BSA
    • L. Zhu, C.S. Lee, and D.L. DeVoe Integrated microfluidic UV absorbance detector with attomol-level sensitivity for BSA Lab Chip 6 2006 115 120
    • (2006) Lab Chip , vol.6 , pp. 115-120
    • Zhu, L.1    Lee, C.S.2    Devoe, D.L.3
  • 23
    • 75749136044 scopus 로고    scopus 로고
    • Modular integration of electronics and microfluidic systems using flexible printed circuit boards
    • A. Wu, L. Wang, E. Jensen, R. Mathies, and B. Boser Modular integration of electronics and microfluidic systems using flexible printed circuit boards Lab Chip 10 2010 519 521
    • (2010) Lab Chip , vol.10 , pp. 519-521
    • Wu, A.1    Wang, L.2    Jensen, E.3    Mathies, R.4    Boser, B.5
  • 24
    • 77949708383 scopus 로고    scopus 로고
    • Capacitively coupled contactless conductivity detection with dual top-bottom cell configuration for microchip electrophoresis
    • K.A. Mahabadi, I. Rodriguez, C.Y. Lim, D.K. Maurya, P.C. Hauser, and N.F. de Rooij Capacitively coupled contactless conductivity detection with dual top-bottom cell configuration for microchip electrophoresis Electrophoresis 31 2010 1063 1070
    • (2010) Electrophoresis , vol.31 , pp. 1063-1070
    • Mahabadi, K.A.1    Rodriguez, I.2    Lim, C.Y.3    Maurya, D.K.4    Hauser, P.C.5    De Rooij, N.F.6
  • 25
    • 55949105542 scopus 로고    scopus 로고
    • High intensity light emitting diode array as an alternative exposure source for the fabrication of electrophoretic microfluidic devices
    • M.C. Breadmore, and R.M. Guijt High intensity light emitting diode array as an alternative exposure source for the fabrication of electrophoretic microfluidic devices J. Chromatogr. A 1213 2008 3 7
    • (2008) J. Chromatogr. A , vol.1213 , pp. 3-7
    • Breadmore, M.C.1    Guijt, R.M.2
  • 26
    • 78649546882 scopus 로고    scopus 로고
    • Capillary electrophoretic separation of mono- and di-saccharides with dynamic pH junction and implementation in microchips
    • A.A. Kazarian, E.F. Hilder, and M.C. Breadmore Capillary electrophoretic separation of mono- and di-saccharides with dynamic pH junction and implementation in microchips Analyst 135 2010 1970 1978
    • (2010) Analyst , vol.135 , pp. 1970-1978
    • Kazarian, A.A.1    Hilder, E.F.2    Breadmore, M.C.3
  • 27
    • 54349095009 scopus 로고    scopus 로고
    • Evaluation of microchip capillary electrophoresis with external contactless conductivity detection for the determination of major inorganic ions and lithium in serum and urine samples
    • P. Kubáň, and P.C. Hauser Evaluation of microchip capillary electrophoresis with external contactless conductivity detection for the determination of major inorganic ions and lithium in serum and urine samples Lab Chip 8 2008 1829 1836
    • (2008) Lab Chip , vol.8 , pp. 1829-1836
    • Kubáň, P.1    Hauser, P.C.2
  • 29
    • 0037115381 scopus 로고    scopus 로고
    • High-voltage capacitively coupled contactless conductivity detection for microchip capillary electrophoresis
    • DOI 10.1021/ac020489+
    • J. Tanyanyiwa, and P.C. Hauser High-voltage capacitively coupled contactless conductivity detection for microchip capillary electrophoresis Anal. Chem. 74 2002 6378 6382 (Pubitemid 36025186)
    • (2002) Analytical Chemistry , vol.74 , Issue.24 , pp. 6378-6382
    • Tanyanyiwa, J.1    Hauser, P.C.2
  • 30
    • 59249095933 scopus 로고    scopus 로고
    • Identification of inorganic ions in post-blast explosive residues using portable CE instrumentation and capacitively coupled contactless conductivity detection
    • J.P. Hutchinson, C. Johns, M.C. Breadmore, E.F. Hilder, R.M. Guijt, C. Lennard, G. Dicinoski, and P.R. Haddad Identification of inorganic ions in post-blast explosive residues using portable CE instrumentation and capacitively coupled contactless conductivity detection Electrophoresis 29 2008 4593 4602
    • (2008) Electrophoresis , vol.29 , pp. 4593-4602
    • Hutchinson, J.P.1    Johns, C.2    Breadmore, M.C.3    Hilder, E.F.4    Guijt, R.M.5    Lennard, C.6    Dicinoski, G.7    Haddad, P.R.8
  • 31
    • 77954137155 scopus 로고    scopus 로고
    • A prefilled, ready-to-use electrophoresis based lab-on-a-chip device for monitoring lithium in blood
    • A. Floris, S. Staal, S. Lenk, E. Staijen, D. Kohlheyer, J. Eijkel, and A. van den Berg A prefilled, ready-to-use electrophoresis based lab-on-a-chip device for monitoring lithium in blood Lab Chip 10 2010 1799 1806
    • (2010) Lab Chip , vol.10 , pp. 1799-1806
    • Floris, A.1    Staal, S.2    Lenk, S.3    Staijen, E.4    Kohlheyer, D.5    Eijkel, J.6    Van Den Berg, A.7
  • 32
    • 77149153677 scopus 로고    scopus 로고
    • Dual contactless conductivity and amperometric detection on hybrid PDMS/glass electrophoresis microchips
    • M. Vázquez, C. Frankenfeld, W.K.T. Coltro, E. Carrilho, D. Diamond, and S.M. Lunte Dual contactless conductivity and amperometric detection on hybrid PDMS/glass electrophoresis microchips Analyst 135 2010 96 103
    • (2010) Analyst , vol.135 , pp. 96-103
    • Vázquez, M.1    Frankenfeld, C.2    Coltro, W.K.T.3    Carrilho, E.4    Diamond, D.5    Lunte, S.M.6
  • 33
    • 79952960665 scopus 로고    scopus 로고
    • Rapid prototyping of polymeric electrophoresis microchips with integrated copper electrodes for contactless conductivity detection
    • W.K.T. Coltro, J.A. Fracassi da Silva, and E. Carrilho Rapid prototyping of polymeric electrophoresis microchips with integrated copper electrodes for contactless conductivity detection Anal. Methods 3 2011 168 172
    • (2011) Anal. Methods , vol.3 , pp. 168-172
    • Coltro, W.K.T.1    Fracassi Da Silva, J.A.2    Carrilho, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.