-
1
-
-
47649105648
-
Toward the wearable artificial kidney
-
Ronco C, Davenport A, Gura V. Toward the wearable artificial kidney. Hemodial. Int. 12(Suppl. 1), S40-S47 (2008).
-
(2008)
Hemodial. Int.
, vol.12
, Issue.SUPPL. 1
-
-
Ronco, C.1
Davenport, A.2
Gura, V.3
-
2
-
-
0017978681
-
Optimal dialysis frequency and duration: The 'unphysiology hypothesis
-
Kjellstrand CM, Rosa AA, Shideman JR, Rodrigo F, Davin T, Lynch RE. Optimal dialysis frequency and duration: The 'unphysiology hypothesis'. Kidney Int. Suppl. (8), S120-S124 (1978).
-
(1978)
Kidney Int. Suppl.
, vol.8
-
-
Kjellstrand, C.M.1
Rosa, A.A.2
Shideman, J.R.3
Rodrigo, F.4
Davin, T.5
Lynch, R.E.6
-
3
-
-
0038003151
-
Patient quality of life on quotidian hemodialysis
-
Heidenheim AP, Muirhead N, Moist L, Lindsay RM. Patient quality of life on quotidian hemodialysis. Am. J. Kidney Dis. 42(1 Suppl.), 36-41 (2003).
-
(2003)
Am. J. Kidney Dis.
, vol.42
, Issue.1 SUPPL.
, pp. 36-41
-
-
Heidenheim, A.P.1
Muirhead, N.2
Moist, L.3
Lindsay, R.M.4
-
4
-
-
0037665414
-
Volume control and blood pressure management in patients undergoing quotidian hemodialysis
-
Nesrallah G, Suri R, Moist L, Kortas C, Lindsay RM. Volume control and blood pressure management in patients undergoing quotidian hemodialysis. Am. J. Kidney Dis. 42(1 Suppl.), 13-17 (2003).
-
(2003)
Am. J. Kidney Dis.
, vol.42
, Issue.1 SUPPL.
, pp. 13-17
-
-
Nesrallah, G.1
Suri, R.2
Moist, L.3
Kortas, C.4
Lindsay, R.M.5
-
6
-
-
0017980169
-
Two new concepts that might lead to a wearable artificial kidney
-
Blackshear PL Jr. Two new concepts that might lead to a wearable artificial kidney. Kidney Int. Suppl. 8, S133-S137 (1978).
-
(1978)
Kidney Int. Suppl.
, vol.8
-
-
Blackshear Jr., P.L.1
-
7
-
-
0016580241
-
A wearable artificial kidney: Functional description of hardware and clinical results
-
Jacobsen SC, Stephen RL, Bulloch EC, Luntz RD, Kolff WJ. A wearable artificial kidney: Functional description of hardware and clinical results. Proc. Clin. Dial. Transplant. Forum 5, 65-71 (1975).
-
(1975)
Proc. Clin. Dial. Transplant. Forum
, vol.5
, pp. 65-71
-
-
Jacobsen, S.C.1
Stephen, R.L.2
Bulloch, E.C.3
Luntz, R.D.4
Kolff, W.J.5
-
8
-
-
0016909861
-
Portable/wearable artificial kidney (WAK) - initial evaluation
-
Stephens RL, Jacobsen SC, Atkin-thor E, Kolff W. Portable/wearable artificial kidney (WAK) - initial evaluation. Proc. Eur. Dial. Transplant. Assoc. 12, 511-518 (1976).
-
(1976)
Proc. Eur. Dial. Transplant. Assoc.
, vol.12
, pp. 511-518
-
-
Stephens, R.L.1
Jacobsen, S.C.2
Atkin-thor, E.3
Kolff, W.4
-
9
-
-
0014375968
-
Factors in membrane design and selection as a step toward a wearable artificial kidney
-
Brown CE, Kramer NC. Factors in membrane design and selection as a step toward a wearable artificial kidney. Trans. Am. Soc. Artif. Intern. Organs 14, 36-42 (1968).
-
(1968)
Trans. Am. Soc. Artif. Intern. Organs
, vol.14
, pp. 36-42
-
-
Brown, C.E.1
Kramer, N.C.2
-
12
-
-
0017562446
-
Exponential growth and future of artificial organs
-
Kolff WJ. Exponential growth and future of artificial organs. Artif. Organs 1(1), 8-18 (1977).
-
(1977)
Artif. Organs
, vol.1
, Issue.1
, pp. 8-18
-
-
Kolff, W.J.1
-
13
-
-
0018206183
-
Sorbent regeneration of ultrafiltrate as a long-term treatment of end-stage renal failure
-
Shaldon S, Beau MC, Claret G. Sorbent regeneration of ultrafiltrate as a long-term treatment of end-stage renal failure. Artif. Organs 2(4), 343-347 (1978).
-
(1978)
Artif. Organs
, vol.2
, Issue.4
, pp. 343-347
-
-
Shaldon, S.1
Beau, M.C.2
Claret, G.3
-
14
-
-
0020606265
-
A portable hemodialysis/hemofiltration system independent of dialysate and infusion fluid
-
Shettigar UR, Kablitz C, Stephen R, Kolff WJ. A portable hemodialysis/hemofiltration system independent of dialysate and infusion fluid. Artif. Organs 7(2), 254-256 (1983).
-
(1983)
Artif. Organs
, vol.7
, Issue.2
, pp. 254-256
-
-
Shettigar, U.R.1
Kablitz, C.2
Stephen, R.3
Kolff, W.J.4
-
15
-
-
0022751070
-
Continuous arterio-venous hemofiltration in a wearable device to treat end-stage renal disease
-
Murisasco A, Reynier JP, Ragon A et al. Continuous arterio-venous hemofiltration in a wearable device to treat end-stage renal disease. Trans. Am. Soc. Artif. Intern. Organs 32(1), 567-571 (1986).
-
(1986)
Trans. Am. Soc. Artif. Intern. Organs
, vol.32
, Issue.1
, pp. 567-571
-
-
Murisasco, A.1
Reynier, J.P.2
Ragon, A.3
-
16
-
-
0017839310
-
Continuous ambulatory peritoneal dialysis
-
Popovich RP, Moncrief JW, Nolph KD, Ghods AJ, Twardowski ZJ, Pyle WK. Continuous ambulatory peritoneal dialysis. Ann. Intern. Med. 88(4), 449-456 (1978).
-
(1978)
Ann. Intern. Med.
, vol.88
, Issue.4
, pp. 449-456
-
-
Popovich, R.P.1
Moncrief, J.W.2
Nolph, K.D.3
Ghods, A.J.4
Twardowski, Z.J.5
Pyle, W.K.6
-
17
-
-
0033200944
-
Innovative peritoneal dialysis: Flow-thru and dialysate regeneration
-
Roberts M, Ash SR, Lee DBN. Innovative peritoneal dialysis: Flow-thru and dialysate regeneration. ASAIO J. 45(5), 372-378 (1999).
-
(1999)
ASAIO J.
, vol.45
, Issue.5
, pp. 372-378
-
-
Roberts, M.1
Ash, S.R.2
Lee, D.B.N.3
-
18
-
-
3142686691
-
Wearable systems for health care applications
-
Lukowicz P, Kirstein T, Troster G. Wearable systems for health care applications. Methods Inf. Med. 43(3), 232-238 (2004).
-
(2004)
Methods Inf. Med.
, vol.43
, Issue.3
, pp. 232-238
-
-
Lukowicz, P.1
Kirstein, T.2
Troster, G.3
-
19
-
-
14844315072
-
New paradigms in telemedicine: Ambient intelligence, wearable, pervasive and personalized
-
Rubel P, Fayn J, Simon-Chautemps L et al. New paradigms in telemedicine: Ambient intelligence, wearable, pervasive and personalized. Stud. Health Technol. Inform. 108, 123-132 (2004).
-
(2004)
Stud. Health Technol. Inform.
, vol.108
, pp. 123-132
-
-
Rubel, P.1
Fayn, J.2
Simon-Chautemps, L.3
-
20
-
-
60349087902
-
The wearable artificial kidney, why and how: From holy grail to reality
-
Gura V, Ronco C, Davenport A. The wearable artificial kidney, why and how: From holy grail to reality. Semin. Dial. 22(1), 13-17 (2009).
-
(2009)
Semin. Dial.
, vol.22
, Issue.1
, pp. 13-17
-
-
Gura, V.1
Ronco, C.2
Davenport, A.3
-
22
-
-
71549114894
-
The implantable artificial kidney
-
Fissell WH, Roy S. The implantable artificial kidney. Semin. Dial. 22(6), 665-670 (2009).
-
(2009)
Semin. Dial.
, vol.22
, Issue.6
, pp. 665-670
-
-
Fissell, W.H.1
Roy, S.2
-
23
-
-
0344541871
-
Protein-membrane interactions during hemodialysis: Effects on solute transport
-
Morti SM, Zydney AL. Protein-membrane interactions during hemodialysis: Effects on solute transport. ASAIO J. 44(4), 319-326 (1998).
-
(1998)
ASAIO J.
, vol.44
, Issue.4
, pp. 319-326
-
-
Morti, S.M.1
Zydney, A.L.2
-
24
-
-
71549122014
-
Blood-membrane interactions during dialysis
-
Huang Z, Gao D, Letteri JJ, Clark WR. Blood-membrane interactions during dialysis. Semin. Dial. 22(6), 623-628 (2009).
-
(2009)
Semin. Dial.
, vol.22
, Issue.6
, pp. 623-628
-
-
Huang, Z.1
Gao, D.2
Letteri, J.J.3
Clark, W.R.4
-
25
-
-
79951829930
-
The future of the artificial kidney: Moving towards wearable and miniaturized devices
-
Ronco C, Davenport A, Gura V. The future of the artificial kidney: Moving towards wearable and miniaturized devices. Nefrologia 31(1), 9-16 (2011).
-
(2011)
Nefrologia
, vol.31
, Issue.1
, pp. 9-16
-
-
Ronco, C.1
Davenport, A.2
Gura, V.3
-
26
-
-
78651397849
-
Enhancement of solute removal in a hollow-fiber hemodialyzer by mechanical vibration
-
Kim JC, Garzotto F, Cruz DN et al. Enhancement of solute removal in a hollow-fiber hemodialyzer by mechanical vibration. Blood Purif. 31(4), 227-234 (2011).
-
(2011)
Blood Purif.
, vol.31
, Issue.4
, pp. 227-234
-
-
Kim, J.C.1
Garzotto, F.2
Cruz, D.N.3
-
27
-
-
80052278990
-
Effects of ambulation on hemodynamics of hollow-fiber hemodialyzer in the wearable artificial kidney
-
Vicenza, Italy, 30 September-1 October
-
Kim JC, Garzotto F, Chung SG, Ronco C. Effects of ambulation on hemodynamics of hollow-fiber hemodialyzer in the wearable artificial kidney. Presented at: World Conference on Portable-Wearable and Miniaturized Systems for Dialysis and Ultrafiltration. Vicenza, Italy, 30 September-1 October 2010.
-
(2010)
Presented at: World Conference on Portable-Wearable and Miniaturized Systems for Dialysis and Ultrafiltration
-
-
Kim, J.C.1
Garzotto, F.2
Chung, S.G.3
Ronco, C.4
-
28
-
-
0033065041
-
Tissue engineering of a bioartificial renal tubule assist device: In vitro transport and metabolic characteristics
-
Humes HD, MacKay SM, Funke AJ, Buffington DA. Tissue engineering of a bioartificial renal tubule assist device: In vitro transport and metabolic characteristics. Kidney Int. 55(6), 2502-2514 (1999).
-
(1999)
Kidney Int.
, vol.55
, Issue.6
, pp. 2502-2514
-
-
Humes, H.D.1
MacKay, S.M.2
Funke, A.J.3
Buffington, D.A.4
-
29
-
-
4644247004
-
Initial clinical results of the bioartificial kidney containing human cells in ICU patients with acute renal failure
-
Humes HD, Weitzel WF, Bartlett RH et al. Initial clinical results of the bioartificial kidney containing human cells in ICU patients with acute renal failure. Kidney Int. 66(4), 1578-1588 (2004).
-
(2004)
Kidney Int.
, vol.66
, Issue.4
, pp. 1578-1588
-
-
Humes, H.D.1
Weitzel, W.F.2
Bartlett, R.H.3
-
30
-
-
34447504974
-
B2-microglobulin removal and plasma albumin levels with high cut-off hemodialysis
-
Haase M, Bellomo R, Baldwin I et al. b2-microglobulin removal and plasma albumin levels with high cut-off hemodialysis. Int. J. Artif. Organs 30(5), 385-392 (2007).
-
(2007)
Int. J. Artif. Organs
, vol.30
, Issue.5
, pp. 385-392
-
-
Haase, M.1
Bellomo, R.2
Baldwin, I.3
-
31
-
-
0942289919
-
Dialysis without membranes: How and why?
-
Leonard EF, West AC, Shapley NC, Larsen MU. Dialysis without membranes: How and why? Blood Purif. 22(1), 92-100 (2004).
-
(2004)
Blood Purif.
, vol.22
, Issue.1
, pp. 92-100
-
-
Leonard, E.F.1
West, A.C.2
Shapley, N.C.3
Larsen, M.U.4
-
32
-
-
24944472625
-
The human nephron filter: Toward a continuously functioning, implantable artificial nephron system
-
Nissenson AR, Ronco C, Pergamit G, Edelstein M, Watts R. The human nephron filter: Toward a continuously functioning, implantable artificial nephron system. Blood Purif. 23(4), 269-274 (2005).
-
(2005)
Blood Purif.
, vol.23
, Issue.4
, pp. 269-274
-
-
Nissenson, A.R.1
Ronco, C.2
Pergamit, G.3
Edelstein, M.4
Watts, R.5
-
33
-
-
49649089251
-
Concept and computational design for a bioartificial nephron-on-a-chip
-
Weinberg E, Kaazempur-Mofrad M, Borenstein J. Concept and computational design for a bioartificial nephron-on-a-chip. Int. J. Artif. Organs 31(6), 508-514 (2008).
-
(2008)
Int. J. Artif. Organs
, vol.31
, Issue.6
, pp. 508-514
-
-
Weinberg, E.1
Kaazempur-Mofrad, M.2
Borenstein, J.3
-
35
-
-
56649106448
-
High-performance silicon nanopore hemofiltration membranes
-
Fissell WH, Dubnisheva A, Eldridge AN, Fleischman AJ, Zydney AL, Roy S. High-performance silicon nanopore hemofiltration membranes. J. Memb. Sci. 326(1), 58-63 (2009).
-
(2009)
J. Memb. Sci.
, vol.326
, Issue.1
, pp. 58-63
-
-
Fissell, W.H.1
Dubnisheva, A.2
Eldridge, A.N.3
Fleischman, A.J.4
Zydney, A.L.5
Roy, S.6
-
36
-
-
79952436419
-
Structural biology: Breaking the protein rules
-
Chouard T. Structural biology: Breaking the protein rules. Nature 471(7337), 151-153 (2011).
-
(2011)
Nature
, vol.471
, Issue.7337
, pp. 151-153
-
-
Chouard, T.1
-
37
-
-
33847132253
-
Charge- and size-based separation of macromolecules using ultrathin silicon membranes
-
Striemer CC, Gaborski TR, McGrath JL, Fauchet PM. Charge- and size-based separation of macromolecules using ultrathin silicon membranes. Nature 445(7129), 749-753 (2007).
-
(2007)
Nature
, vol.445
, Issue.7129
, pp. 749-753
-
-
Striemer, C.C.1
Gaborski, T.R.2
McGrath, J.L.3
Fauchet, P.M.4
-
38
-
-
67849118864
-
Multilayered microfilter using a nanoporous PES membrane and applicable as the dialyzer of a wearable artificial kidney
-
Gu Y, Miki N. Multilayered microfilter using a nanoporous PES membrane and applicable as the dialyzer of a wearable artificial kidney. J. Micromech. Microeng. 19(6), 065031 (2009).
-
(2009)
J. Micromech. Microeng.
, vol.19
, Issue.6
, pp. 065031
-
-
Gu, Y.1
Miki, N.2
-
39
-
-
0015181098
-
Clinical maintenance hemodialysis with a sorbent-based, low-volume dialysate regeneration system
-
Gordon A, Better OS, Greenbaum MA, Marantz LB, Gral T, Maxwell MH. Clinical maintenance hemodialysis with a sorbent-based, low-volume dialysate regeneration system. Trans. Am. Soc. Artif. Intern. Organs 17, 253-258 (1971).
-
(1971)
Trans. Am. Soc. Artif. Intern. Organs
, vol.17
, pp. 253-258
-
-
Gordon, A.1
Better, O.S.2
Greenbaum, M.A.3
Marantz, L..B.4
Gral, T.5
Maxwell, M.H.6
-
40
-
-
0016360376
-
Experience with a sorbent-based dialysate regeneration system for hemodialysis
-
Blagg CR, Vizzo JE, Jensen WB, Cole JJ. Experience with a sorbent-based dialysate regeneration system for hemodialysis. Prog. Biochem. Pharmacol. 9, 239-248 (1974).
-
(1974)
Prog. Biochem. Pharmacol.
, vol.9
, pp. 239-248
-
-
Blagg, C.R.1
Vizzo, J.E.2
Jensen, W..B.3
Cole, J.J.4
-
41
-
-
0018651980
-
Applications of the Redy® sorbent system to hemodialysis and peritoneal dialysis
-
Blumenkrantz MJ, Gordon A, Roberts M. Applications of the Redy® sorbent system to hemodialysis and peritoneal dialysis. Artif. Organs 3(3), 230-236 (1979).
-
(1979)
Artif. Organs
, vol.3
, Issue.3
, pp. 230-236
-
-
Blumenkrantz, M.J.1
Gordon, A.2
Roberts, M.3
-
42
-
-
77952896986
-
Review: Understanding sorbent dialysis systems
-
Agar JWM. Review: Understanding sorbent dialysis systems. Nephrology (Carlton) 15(4), 406-411 (2010).
-
(2010)
Nephrology (Carlton)
, vol.15
, Issue.4
, pp. 406-411
-
-
Agar, J.W.M.1
-
43
-
-
0017211379
-
Cold carbon apparatus for hemodialysis
-
Giordano C, Esposito R, Bello P. Cold carbon apparatus for hemodialysis. J. Dial. 1(2), 165-179 (1976).
-
(1976)
J. Dial.
, vol.1
, Issue.2
, pp. 165-179
-
-
Giordano, C.1
Esposito, R.2
Bello, P.3
-
44
-
-
65549136335
-
Development of a cold dialysate regeneration system for home hemodialysis
-
Kim JH, Kim JC, Moon JH et al. Development of a cold dialysate regeneration system for home hemodialysis. Blood Purif. 28(2), 84-92 (2009).
-
(2009)
Blood Purif.
, vol.28
, Issue.2
, pp. 84-92
-
-
Kim, J.H.1
Kim, J.C.2
Moon, J.H.3
-
45
-
-
0025610759
-
A new approach for the filtrate regeneration system in the wearable artificial kidney
-
Tada Y, Horiuchi T, Ohta Y, Dohi T. A new approach for the filtrate regeneration system in the wearable artificial kidney. Artif. Organs 14(6), 405-409 (1990).
-
(1990)
Artif. Organs
, vol.14
, Issue.6
, pp. 405-409
-
-
Tada, Y.1
Horiuchi, T.2
Ohta, Y.3
Dohi, T.4
-
46
-
-
0018188004
-
A resin-sorbent system for dialysate regeneration
-
Giordano C, Esposito R, Bello P, Quarto E. A resin-sorbent system for dialysate regeneration. Kidney Int. 13(Suppl. 8), S138-S144 (1978).
-
(1978)
Kidney Int.
, vol.13
, Issue.SUPPL. 8
-
-
Giordano, C.1
Esposito, R.2
Bello, P.3
Quarto, E.4
-
47
-
-
0028588909
-
The microspheres based detoxification system (MDS): A new extracorporeal blood purification technology based on recirculated microspherical adsorbent particles
-
Weber C, Rajnoch C, Loth F, Schima H, Falkenhagen D. The microspheres based detoxification system (MDS): A new extracorporeal blood purification technology based on recirculated microspherical adsorbent particles. Int. J. Artif. Organs 17(11), 595-602 (1994).
-
(1994)
Int. J. Artif. Organs
, vol.17
, Issue.11
, pp. 595-602
-
-
Weber, C.1
Rajnoch, C.2
Loth, F.3
Schima, H.4
Falkenhagen, D.5
-
48
-
-
71549145358
-
Sorbents in treatment of uremia: A short history and a great future
-
Ash SR. Sorbents in treatment of uremia: A short history and a great future. Semin. Dial. 22(6), 615-622 (2009).
-
(2009)
Semin. Dial.
, vol.22
, Issue.6
, pp. 615-622
-
-
Ash, S.R.1
-
49
-
-
73249134399
-
Technical breakthroughs in the wearable artificial kidney (WAK)
-
Gura V, Macy AS, Beizai M, Ezon C, Golper TA. Technical breakthroughs in the wearable artificial kidney (WAK). Clin. J. Am. Soc. Nephrol. 4(9), 1441-1448 (2009).
-
(2009)
Clin. J. Am. Soc. Nephrol.
, vol.4
, Issue.9
, pp. 1441-1448
-
-
Gura, V.1
Macy, A.S.2
Beizai, M.3
Ezon, C.4
Golper, T.A.5
-
50
-
-
20544477737
-
Continuous renal replacement therapy for end-stage renal disease. The wearable artificial kidney (WAK)
-
Gura V, Beizai M, Ezon C, Polaschegg HD. Continuous renal replacement therapy for end-stage renal disease. The wearable artificial kidney (WAK). Contrib. Nephrol. 149, 325-333 (2005).
-
(2005)
Contrib. Nephrol.
, vol.149
, pp. 325-333
-
-
Gura, V.1
Beizai, M.2
Ezon, C.3
Polaschegg, H.D.4
-
51
-
-
34548639001
-
On-chip microfluidic biosensor for bacterial detection and identification
-
Boehm DA, Gottlieb PA, Hua SZ. On-chip microfluidic biosensor for bacterial detection and identification. Sens. Actuators B Chem. 126(2), 508-514 (2007).
-
(2007)
Sens. Actuators B Chem.
, vol.126
, Issue.2
, pp. 508-514
-
-
Boehm, D.A.1
Gottlieb, P.A.2
Hua, S.Z.3
-
52
-
-
79952149683
-
Towards a fast, high specific and reliable discrimination of bacteria on strain level by means of SERS in a microfluidic device
-
Walter A, Marz A, Schumacher W, Rosch P, Popp J. Towards a fast, high specific and reliable discrimination of bacteria on strain level by means of SERS in a microfluidic device. Lab Chip 11(6), 1013-1021 (2011).
-
(2011)
Lab Chip
, vol.11
, Issue.6
, pp. 1013-1021
-
-
Walter, A.1
Marz, A.2
Schumacher, W.3
Rosch, P.4
Popp, J.5
-
53
-
-
0025077593
-
Pitfalls of wearable artificial kidney
-
Vanholder R, Ringoir S. Pitfalls of wearable artificial kidney. Int. J. Artif. Organs 13(11), 715-719 (1990).
-
(1990)
Int. J. Artif. Organs
, vol.13
, Issue.11
, pp. 715-719
-
-
Vanholder, R.1
Ringoir, S.2
-
55
-
-
77954952310
-
Buttonhole needling of ateriovenous fistulae: A randomized controlled trial
-
Struthers J, Allan A, Peel RK, Lambie SH. Buttonhole needling of ateriovenous fistulae: A randomized controlled trial. ASAIO J. 56(4), 319-322 (2010).
-
(2010)
ASAIO J.
, vol.56
, Issue.4
, pp. 319-322
-
-
Struthers, J.1
Allan, A.2
Peel, R.K.3
Lambie, S.H.4
-
56
-
-
38849113423
-
Is single-needle hemodialysis still a good treatment in end-stage renal disease?
-
Trakarnvanich T, Chirananthavat T, Maneerat P, Chabsuwan S, Areeyakulnimit S. Is single-needle hemodialysis still a good treatment in end-stage renal disease? Blood Purif. 25(5-6), 490-496 (2007).
-
(2007)
Blood Purif.
, vol.25
, Issue.5-6
, pp. 490-496
-
-
Trakarnvanich, T.1
Chirananthavat, T.2
Maneerat, P.3
Chabsuwan, S.4
Areeyakulnimit, S.5
-
57
-
-
67651146413
-
Improving the efficiency of short-term single-needle hemodialysis
-
Rostoker G, Griuncelli M, Loridon C, Bourlet T, Welsch K, Benmaadi A. Improving the efficiency of short-term single-needle hemodialysis. Ren. Fail. 31(4), 261-266 (2009).
-
(2009)
Ren. Fail.
, vol.31
, Issue.4
, pp. 261-266
-
-
Rostoker, G.1
Griuncelli, M.2
Loridon, C.3
Bourlet, T.4
Welsch, K.5
Benmaadi, A.6
-
58
-
-
0033744764
-
Initial clinical results with the LifeSite Hemodialysis Access System
-
Beathard GA, Posen GA. Initial clinical results with the LifeSite Hemodialysis Access System. Kidney Int. 58(5), 2221-2227 (2000).
-
(2000)
Kidney Int.
, vol.58
, Issue.5
, pp. 2221-2227
-
-
Beathard, G.A.1
Posen, G.A.2
-
59
-
-
33748281167
-
Efficacy and safety results with the LifeSite hemodialysis access system versus the Tesio-Cath hemodialysis catheter at 12 months
-
Rosenblatt M, Caridi JG, Hakki FZ et al. Efficacy and safety results with the LifeSite hemodialysis access system versus the Tesio-Cath hemodialysis catheter at 12 months. J. Vasc. Interv. Radiol. 17(3), 497-504 (2006).
-
(2006)
J. Vasc. Interv. Radiol.
, vol.17
, Issue.3
, pp. 497-504
-
-
Rosenblatt, M.1
Caridi, J.G.2
Hakki, F.Z.3
-
60
-
-
0033004921
-
Dialock: A new vascular access device for extracorporeal renal replacement therapy. Preliminary clinical results
-
Canaud B, My H, Morena M et al. Dialock: A new vascular access device for extracorporeal renal replacement therapy. Preliminary clinical results. Nephrol. Dial. Transplant. 14(3), 692-698 (1999).
-
(1999)
Nephrol. Dial. Transplant.
, vol.14
, Issue.3
, pp. 692-698
-
-
Canaud, .B.1
My, H.2
Morena, M.3
-
61
-
-
0034957361
-
Dialock® subcutaneous port for hemodialysis: A twelve-month experience in a single center
-
Quarello F, Forneris G, Formica M et al. Dialock® subcutaneous port for hemodialysis: A twelve-month experience in a single center. J. Vasc. Access 2(2), 73-79 (2001).
-
(2001)
J. Vasc. Access
, vol.2
, Issue.2
, pp. 73-79
-
-
Quarello, F.1
Forneris, G.2
Formica, M.3
-
62
-
-
33750119797
-
Paclitaxel-coated expanded polytetrafluoroethylene haemodialysis grafts inhibit neointimal hyperplasia in porcine model of graft stenosis
-
Lee BH, Nam HY, Kwon T et al. Paclitaxel-coated expanded polytetrafluoroethylene haemodialysis grafts inhibit neointimal hyperplasia in porcine model of graft stenosis. Nephrol. Dial. Transplant. 21(9), 2432-2438 (2006).
-
(2006)
Nephrol. Dial. Transplant.
, vol.21
, Issue.9
, pp. 2432-2438
-
-
Lee, B.H.1
Nam, H.Y.2
Kwon, T.3
-
63
-
-
71249143028
-
Induction of EPC homing on biofunctionalized vascular grafts for rapid in vivo self-endothelialization - A review of current strategies
-
Avci-Adali M, Ziemer G, Wendel HP. Induction of EPC homing on biofunctionalized vascular grafts for rapid in vivo self-endothelialization - a review of current strategies. Biotechnol. Adv. 28(1), 119-129 (2010).
-
(2010)
Biotechnol. Adv.
, vol.28
, Issue.1
, pp. 119-129
-
-
Avci-Adali, M.1
Ziemer, G.2
Wendel, H.P.3
-
64
-
-
0141954082
-
Recent advances in the discovery and development of direct coagulation factor Xa inhibitors
-
Gould WR, Leadley RJ. Recent advances in the discovery and development of direct coagulation factor Xa inhibitors. Curr. Pharm. Des. 9(28), 2337-2347 (2003).
-
(2003)
Curr. Pharm. Des.
, vol.9
, Issue.28
, pp. 2337-2347
-
-
Gould, W.R.1
Leadley, R.J.2
-
65
-
-
29144518504
-
Safety, pharmacodynamics, and pharmacokinetics of BAY 59-7939 - an oral, direct Factor Xa inhibitor - after multiple dosing in healthy male subjects
-
Kubitza D, Becka M, Wensing G, Voith B, Zuehlsdorf M. Safety, pharmacodynamics, and pharmacokinetics of BAY 59-7939 - an oral, direct Factor Xa inhibitor - after multiple dosing in healthy male subjects. Eur. J. Clin. Pharmacol. 61(12), 873-880 (2005).
-
(2005)
Eur. J. Clin. Pharmacol.
, vol.61
, Issue.12
, pp. 873-880
-
-
Kubitza, D.1
Becka, M.2
Wensing, G.3
Voith, .B.4
Zuehlsdorf, M.5
-
66
-
-
53849107475
-
Low-end videoconferencing for vascular access device site assessment in homecare
-
Astapova EV, Stachura ME, Chernecky C, Rosenkoetter MM. Low-end videoconferencing for vascular access device site assessment in homecare. J. Assoc. Vasc. Access 13(3), 135-138 (2008).
-
(2008)
J. Assoc. Vasc. Access
, vol.13
, Issue.3
, pp. 135-138
-
-
Astapova, E.V.1
Stachura, M.E.2
Chernecky, C.3
Rosenkoetter, M.M.4
-
67
-
-
77954406460
-
Comparison of different methods to assess fistula flow
-
Eloot S, Dhondt A, Hoeben H, Vanholder R. Comparison of different methods to assess fistula flow. Blood Purif. 30(2), 89-95 (2010).
-
(2010)
Blood Purif.
, vol.30
, Issue.2
, pp. 89-95
-
-
Eloot, S.1
Dhondt, A.2
Hoeben, H.3
Vanholder, R.4
-
69
-
-
77952897798
-
Visualized sclerotherapy of varicose veins
-
Kikuchi M, Hosokawa K. Visualized sclerotherapy of varicose veins. Dermatol. Surg. 36(Suppl. 2), 1050-1055 (2010).
-
(2010)
Dermatol. Surg.
, vol.36
, Issue.SUPPL. 2
, pp. 1050-1055
-
-
Kikuchi, M.1
Hosokawa, K.2
-
70
-
-
0038003149
-
Patient monitoring in the London Daily/Nocturnal Hemodialysis Study
-
Heidenheim AP, Leitch R, Kortas C, Lindsay RM. Patient monitoring in the London Daily/Nocturnal Hemodialysis Study. Am. J. Kidney Dis. 42(1 Suppl.), 61-65 (2003).
-
(2003)
Am. J. Kidney Dis.
, vol.42
, Issue.1 SUPPL.
, pp. 61-65
-
-
Heidenheim, A.P.1
Leitch, R.2
Kortas, C.3
Lindsay, R.M.4
-
71
-
-
34748903407
-
Wearable and portable eHealth systems. Technological issues and opportunities for personalized care
-
Gatzoulis L, Iakovidis I. Wearable and portable eHealth systems. Technological issues and opportunities for personalized care. IEEE Eng. Med. Biol. Mag. 26(5), 51-56 (2007).
-
(2007)
IEEE Eng. Med. Biol. Mag.
, vol.26
, Issue.5
, pp. 51-56
-
-
Gatzoulis, L.1
Iakovidis, I.2
-
72
-
-
0842325877
-
Intelligent biomedical clothing for personal health and disease management: State of the art and future vision
-
Lymberis A, Olsson S. Intelligent biomedical clothing for personal health and disease management: State of the art and future vision. Telemed. J. E. Health. 9(4), 379-386 (2003).
-
(2003)
Telemed. J. E. Health.
, vol.9
, Issue.4
, pp. 379-386
-
-
Lymberis, A.1
Olsson, S.2
-
73
-
-
34548702456
-
A wearable mobihealth care system supporting real-time diagnosis and alarm
-
Zheng JW, Zhang ZB, Wu TH, Zhang Y. A wearable mobihealth care system supporting real-time diagnosis and alarm. Med. Biol. Eng. Comput. 45(9), 877-885 (2007).
-
(2007)
Med. Biol. Eng. Comput.
, vol.45
, Issue.9
, pp. 877-885
-
-
Zheng, J.W.1
Zhang, Z..B.2
Wu, T.H.3
Zhang, Y.4
-
74
-
-
40549098384
-
Telemonitoring and telerehabilitation of patients with Parkinson's disease: Health technology assessment of a novel wearable step counter
-
Giansanti D, Macellari V, Maccioni G. Telemonitoring and telerehabilitation of patients with Parkinson's disease: Health technology assessment of a novel wearable step counter. Telemed. J. E. Health 14(1), 76-83 (2008).
-
(2008)
Telemed. J. E. Health
, vol.14
, Issue.1
, pp. 76-83
-
-
Giansanti, D.1
Macellari, V.2
Maccioni, G.3
-
75
-
-
11144322984
-
Opportunities at the skin interface for continuous patient monitoring: A reverse iontophoresis model tested on lactate and glucose
-
Connolly P, Cotton C, Morin F. Opportunities at the skin interface for continuous patient monitoring: A reverse iontophoresis model tested on lactate and glucose. IEEE Trans. Nanobioscience 1(1), 37-41 (2002).
-
(2002)
IEEE Trans. Nanobioscience
, vol.1
, Issue.1
, pp. 37-41
-
-
Connolly, P.1
Cotton, C.2
Morin, F.3
-
76
-
-
33846982537
-
Monitoring the well-being of older people
-
Sixsmith A, Hine N, Neild I, Clarke N, Brown S, Garner P. Monitoring the well-being of older people. Top. Geriatr. Rehabil. 23(1), 9-23 (2007).
-
(2007)
Top. Geriatr. Rehabil.
, vol.23
, Issue.1
, pp. 9-23
-
-
Sixsmith, A.1
Hine, N.2
Neild, I.3
Clarke, N.4
Brown, S.5
Garner, P.6
-
77
-
-
55549132656
-
Unobtrusive assessment of activity patterns associated with mild cognitive impairment
-
Hayes TL, Abendroth F, Adami A, Pavel M, Zitzelberger TA, Kaye JA. Unobtrusive assessment of activity patterns associated with mild cognitive impairment. Alzheimers Dement. 4(6), 395-405 (2008).
-
(2008)
Alzheimers Dement.
, vol.4
, Issue.6
, pp. 395-405
-
-
Hayes, T.L.1
Abendroth, F.2
Adami, A.3
Pavel, M.4
Zitzelberger, T.A.5
Kaye, J.A.6
-
78
-
-
62649168700
-
Nonintrusive biological signal monitoring in a car to evaluate a driver's stress and health state
-
Baek HJ, Lee HB, Kim JS, Choi JM, Kim KK, Park KS. Nonintrusive biological signal monitoring in a car to evaluate a driver's stress and health state. Telemed. J. E. Health 15(2), 182-189 (2009).
-
(2009)
Telemed. J. E. Health
, vol.15
, Issue.2
, pp. 182-189
-
-
Baek, H.J.1
Lee, H..B.2
Kim, J.S.3
Choi, J.M.4
Kim, K.K.5
Park, K.S.6
-
79
-
-
77956464930
-
Energy sources and their development for application in medical devices
-
Rasouli M, Phee LSJ. Energy sources and their development for application in medical devices. Expert Rev. Med. Devices 7(5), 693-709 (2010).
-
(2010)
Expert Rev. Med. Devices
, vol.7
, Issue.5
, pp. 693-709
-
-
Rasouli, M.1
Phee, L.S.J.2
-
80
-
-
77956460452
-
Lithium batteries for medical applications
-
Nazri G-A, Pistoia G (Eds). Springer, NY, USA
-
Takeuchi ES, Leising RA, Spillman DM et al. Lithium batteries for medical applications. In:Lithium Batteries: Science and Technology. Nazri G-A, Pistoia G (Eds). Springer, NY, USA, 686-700 (2003).
-
(2003)
Lithium Batteries: Science and Technology.
, pp. 686-700
-
-
Takeuchi, E.S.1
Leising, R.A.2
Spillman, D.M.3
-
81
-
-
77956259639
-
Lithium transport at silicon thin film: Barrier for high-rate capability anode
-
Peng B, Cheng F, Tao Z, Chen J. Lithium transport at silicon thin film: Barrier for high-rate capability anode. J. Chem. Phys. 133(3), 034701 (2010).
-
(2010)
J. Chem. Phys.
, vol.133
, Issue.3
, pp. 034701
-
-
Peng, .B.1
Cheng, F.2
Tao, Z.3
Chen, J.4
-
82
-
-
38949101650
-
Materials science. Toward flexible batteries
-
Nishide H, Oyaizu K. Materials science. Toward flexible batteries. Science 319(5864), 737-738 (2008).
-
(2008)
Science
, vol.319
, Issue.5864
, pp. 737-738
-
-
Nishide, H.1
Oyaizu, K.2
-
83
-
-
36849085855
-
A wearable haemodialysis device for patients with end-stage renal failure: A pilot study
-
Davenport A, Gura V, Ronco C, Beizai M, Ezon C, Rambod E. A wearable haemodialysis device for patients with end-stage renal failure: A pilot study. Lancet 370(9604), 2005-2010 (2007).
-
(2007)
Lancet
, vol.370
, Issue.9604
, pp. 2005-2010
-
-
Davenport, A.1
Gura, V.2
Ronco, C.3
Beizai, M.4
Ezon, C.5
Rambod, E.6
-
85
-
-
34548857693
-
The vicenza wearable artificial kidney for peritoneal dialysis (ViWAK PD)
-
Ronco C, Fecondini L. The vicenza wearable artificial kidney for peritoneal dialysis (ViWAK PD). Blood Purif. 25(4), 383-388 (2007).
-
(2007)
Blood Purif.
, vol.25
, Issue.4
, pp. 383-388
-
-
Ronco, C.1
Fecondini, L.2
-
86
-
-
44149093557
-
A peritoneal-based automated wearable artificial kidney
-
Lee DBN, Roberts M. A peritoneal-based automated wearable artificial kidney. Clin. Exp. Nephrol. 12(3), 171-180 (2008).
-
(2008)
Clin. Exp. Nephrol.
, vol.12
, Issue.3
, pp. 171-180
-
-
Lee, D.B.N.1
Roberts, M.2
-
87
-
-
38749137748
-
A wearable hemofilter for continuous ambulatory ultrafiltration
-
Gura V, Ronco C, Nalesso F et al. A wearable hemofilter for continuous ambulatory ultrafiltration. Kidney Int. 73(4), 497-502 (2008).
-
(2008)
Kidney Int.
, vol.73
, Issue.4
, pp. 497-502
-
-
Gura, V.1
Ronco, C.2
Nalesso, F.3
-
88
-
-
36049035646
-
Development of continuous implantable renal replacement: Past and future
-
Fissell WH, Fleischman AJ, Humes HD, Roy S. Development of continuous implantable renal replacement: Past and future. Transl. Res. 150(6), 327-336 (2007).
-
(2007)
Transl. Res.
, vol.150
, Issue.6
, pp. 327-336
-
-
Fissell, W.H.1
Fleischman, A.J.2
Humes, H.D.3
Roy, S.4
-
89
-
-
20544435028
-
Slow continuous intravenous plasmapheresis (SCIP): Clinical applications and hemostability of extracorporeal ultrafiltration
-
Handley HH, Gorsuch R, Peters H et al. Slow continuous intravenous plasmapheresis (SCIP): Clinical applications and hemostability of extracorporeal ultrafiltration. Contrib. Nephrol. 149, 334-342 (2005).
-
(2005)
Contrib. Nephrol.
, vol.149
, pp. 334-342
-
-
Handley, H.H.1
Gorsuch, R.2
Peters, H.3
|