메뉴 건너뛰기




Volumn 23, Issue 4, 2005, Pages 269-274

The human nephron filter: Toward a continuously functioning, implantable artificial nephron system

Author keywords

Dialysis; Hemodialysis; Membranes; Nanotechnology; Renal replacement therapy

Indexed keywords

ARTIFICIAL KIDNEY; ARTIFICIAL MEMBRANE; BLOOD FILTER; COMPUTER MODEL; DEVICE; DIALYSATE; FEASIBILITY STUDY; GLOMERULUS; GLOMERULUS FILTRATION RATE; HEMODIALYSIS; INTERMETHOD COMPARISON; KIDNEY TRANSPLANTATION; KIDNEY TUBULE; NANOTECHNOLOGY; NEPHRON; PARTICLE SIZE; PRIORITY JOURNAL; QUALITY OF LIFE; REVIEW; SOLUTE; TIME; TREATMENT OUTCOME;

EID: 24944472625     PISSN: 02535068     EISSN: None     Source Type: Journal    
DOI: 10.1159/000085882     Document Type: Review
Times cited : (50)

References (21)
  • 3
    • 0034798945 scopus 로고    scopus 로고
    • Daily hemodialysis efficiency: An analysis of solute kinetics
    • Depner TA: Daily hemodialysis efficiency: An analysis of solute kinetics. Adv Ren Replace Ther 2001;8:227-235.
    • (2001) Adv Ren Replace Ther , vol.8 , pp. 227-235
    • Depner, T.A.1
  • 4
    • 0034792790 scopus 로고    scopus 로고
    • Hemeral (daily) hemodialysis
    • Lindsay RM, Kortas C, Daily/Nocturnal Dialysis Study Group: Hemeral (daily) hemodialysis. Adv Ren Replace Ther 2001;8:236-249.
    • (2001) Adv Ren Replace Ther , vol.8 , pp. 236-249
    • Lindsay, R.M.1    Kortas, C.2
  • 5
    • 21344435667 scopus 로고    scopus 로고
    • Daily (quotidian) nocturnal home hemodialysis: Nine years later
    • Pierratos A: Daily (quotidian) nocturnal home hemodialysis: Nine years later. Hemodial Int 2004;8:45-50.
    • (2004) Hemodial Int , vol.8 , pp. 45-50
    • Pierratos, A.1
  • 6
    • 0033491555 scopus 로고    scopus 로고
    • Hemodialysis 1912-1945: No medical technology before its time. Part 1
    • Fagette P: Hemodialysis 1912-1945: No medical technology before its time. Part 1. ASAIO J 1999;45:238-249.
    • (1999) ASAIO J , vol.45 , pp. 238-249
    • Fagette, P.1
  • 7
    • 0033200873 scopus 로고    scopus 로고
    • Hemodialysis 1912-1945: No medical technology before its time. Part 2
    • Fagette P: Hemodialysis 1912-1945: No medical technology before its time. Part 2. ASAIO J 1999;45:379-391.
    • (1999) ASAIO J , vol.45 , pp. 379-391
    • Fagette, P.1
  • 9
    • 0033281409 scopus 로고    scopus 로고
    • Recent developments in conductivity monitoring of haemodialysis session
    • Petitclerc T: Recent developments in conductivity monitoring of haemodialysis session. Nephrol Dial Transplant 1999;14:2607-2613.
    • (1999) Nephrol Dial Transplant , vol.14 , pp. 2607-2613
    • Petitclerc, T.1
  • 10
    • 15444374122 scopus 로고    scopus 로고
    • Hemofiltration as a treatment for end-stage renal disease
    • Zimmerman DL: Hemofiltration as a treatment for end-stage renal disease. Hemodial Int 2004;8:183-187.
    • (2004) Hemodial Int , vol.8 , pp. 183-187
    • Zimmerman, D.L.1
  • 11
    • 0346157034 scopus 로고    scopus 로고
    • Middle molecules and small-molecular-weight proteins in ESRD: Properties and strategies for their removal
    • Clark WR, Winchester JF: Middle molecules and small-molecular-weight proteins in ESRD: Properties and strategies for their removal. Adv Ren Replace Ther 2003;10:270-278.
    • (2003) Adv Ren Replace Ther , vol.10 , pp. 270-278
    • Clark, W.R.1    Winchester, J.F.2
  • 14
    • 0028790340 scopus 로고
    • Hemodialyzer performance: A review of the trends over the past two decades
    • Woffindin C, Hoenich NA: Hemodialyzer performance: A review of the trends over the past two decades. Artif Organs 1995;19:1113-1119.
    • (1995) Artif Organs , vol.19 , pp. 1113-1119
    • Woffindin, C.1    Hoenich, N.A.2
  • 15
    • 0035235707 scopus 로고    scopus 로고
    • Quantitative characterization of hemodialyzer solute and water transport
    • Clark WR: Quantitative characterization of hemodialyzer solute and water transport. Semin Dial 2001;14:32-36.
    • (2001) Semin Dial , vol.14 , pp. 32-36
    • Clark, W.R.1
  • 16
    • 0009555201 scopus 로고    scopus 로고
    • What clinically important advances in understanding and improving dialyzer function have occurred recently?
    • Ronco C: What clinically important advances in understanding and improving dialyzer function have occurred recently? Semin Dial 2001;3:164-169.
    • (2001) Semin Dial , vol.3 , pp. 164-169
    • Ronco, C.1
  • 17
    • 26544437639 scopus 로고    scopus 로고
    • The human nephron filter-1 (HNF-1): Toward a continuously functioning, implantable artificial nephron system by applying nanotechnology (NT)
    • Nissenson AR, Pergamit G, Edelstein M, Watts R: The human nephron filter-1 (HNF-1): Toward a continuously functioning, implantable artificial nephron system by applying nanotechnology (NT) (abstract). Am Soc Nephrol Annu Meet, 2003, www.asn-online.org.
    • (2003) Am Soc Nephrol Annu Meet
    • Nissenson, A.R.1    Pergamit, G.2    Edelstein, M.3    Watts, R.4
  • 19
    • 0009555732 scopus 로고    scopus 로고
    • Nanomedicine nears the clinic
    • Voss D: Nanomedicine nears the clinic. Tech Rev 2000;Jan/Feb:60-65.
    • (2000) Tech Rev , vol.JAN-FEB , pp. 60-65
    • Voss, D.1
  • 20
    • 0000361291 scopus 로고    scopus 로고
    • Quantum Dot Com
    • Rotman D: Quantum Dot Com. Tech Rev 2000;Jan/Feb:51-57.
    • (2000) Tech Rev , vol.JAN-FEB , pp. 51-57
    • Rotman, D.1
  • 21
    • 0035741792 scopus 로고    scopus 로고
    • Does nanotechnology apply to dialysis?
    • Ronco C, Nissenson AR: Does nanotechnology apply to dialysis? Blood Purif 2001;19:347-352.
    • (2001) Blood Purif , vol.19 , pp. 347-352
    • Ronco, C.1    Nissenson, A.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.