-
1
-
-
1542289037
-
Human lumbar facet joint capsule strains: I. During physiological motions
-
DOI 10.1016/j.spinee.2003.07.008, PII S1529943003004972
-
A Ianuzzi, JS Little, JB Chiu, A Baitner, G Kawchuk, and PS Khalsa Human lumbar facet joint capsule strains: I. During physiological motions Spine J 4 2004 141 152 (Pubitemid 38304992)
-
(2004)
Spine Journal
, vol.4
, Issue.2
, pp. 141-152
-
-
Ianuzzi, A.1
Little, J.S.2
Chiu, J.B.3
Baitner, A.4
Kawchuk, G.5
Khalsa, P.S.6
-
2
-
-
0019969097
-
Physiologic strains in the lumbar spinal ligaments: An in vitro biomechanical study
-
DOI 10.1097/00007632-198205000-00003
-
MM Panjabi, VK Goel, and K Takata Physiologic strains in the lumbar spinal ligaments. An in vitro biomechanical study. 1981 Volvo Award in Biomechanics Spine (Phila Pa 1976) 7 1982 192 203 (Pubitemid 12038260)
-
(1982)
Spine
, vol.7
, Issue.3
, pp. 192-203
-
-
Panjabi, M.M.1
Goel, V.K.2
Takata, K.3
-
3
-
-
0030248235
-
Lumbar facet pain: Biomechanics, neuroanatomy and neurophysiology
-
DOI 10.1016/0021-9290(96)00023-1
-
JM Cavanaugh, AC Ozaktay, HT Yamashita, and AI King Lumbar facet pain: biomechanics, neuroanatomy and neurophysiology J.Biomech. 29 1996 1117 1129 (Pubitemid 26302177)
-
(1996)
Journal of Biomechanics
, vol.29
, Issue.9
, pp. 1117-1129
-
-
Cavanaugh, J.M.1
Ozaktay, A.C.2
Yamashita, H.T.3
King, A.I.4
-
4
-
-
0032518367
-
Mechanoreceptor endings in human thoracic and lumbar facet joints
-
DOI 10.1097/00007632-199801150-00004
-
RF McLain, and JG Pickar Mechanoreceptor endings in human thoracic and lumbar facet joints Spine 23 1998 168 173 (Pubitemid 28128149)
-
(1998)
Spine
, vol.23
, Issue.2
, pp. 168-173
-
-
McLain, R.F.1
Pickar, J.G.2
-
5
-
-
0024991117
-
Mechanosensitive afferent units in the lumbar facet joint
-
T Yamashita, JM Cavanaugh, AA el Bohy, TV Getchell, and AI King Mechanosensitive afferent units in the lumbar facet joint J Bone Joint Surg Am 72 1990 865 870 (Pubitemid 20246890)
-
(1990)
Journal of Bone and Joint Surgery - Series A
, vol.72
, Issue.6
, pp. 865-870
-
-
Yamashita, T.1
Cavanaugh, J.M.2
El-Bohy, A.A.3
Getchell, T.V.4
King, A.I.5
-
6
-
-
0031028805
-
Mechanisms of low back pain: A neurophysiologic and neuroanatomic study
-
JM Cavanaugh, AC Ozaktay, T Yamashita, A Avramov, TV Getchell, and AI King Mechanisms of low back pain: a neurophysiologic and neuroanatomic study Clin.Orthop 1997 166 180 (Pubitemid 27074494)
-
(1997)
Clinical Orthopaedics and Related Research
, Issue.335
, pp. 166-180
-
-
Cavanaugh, J.M.1
Ozaktay, A.C.2
Yamashita, T.3
Avramov, A.4
Getchell, T.V.5
King, A.I.6
-
7
-
-
0036759028
-
Neurophysiological effects of spinal manipulation
-
JG Pickar Neurophysiological effects of spinal manipulation Spine J 2 2002 357 371
-
(2002)
Spine J
, vol.2
, pp. 357-371
-
-
Pickar, J.G.1
-
8
-
-
0032798021
-
An in vivo preparation for investigating neural responses to controlled loading of a lumbar vertebra in the anesthetized cat
-
DOI 10.1016/S0165-0270(99)00060-6, PII S0165027099000606
-
JG Pickar An in vivo preparation for investigating neural responses to controlled loading of a lumbar vertebra in the anesthetized cat J Neurosci Methods 89 1999 87 96 (Pubitemid 29361502)
-
(1999)
Journal of Neuroscience Methods
, vol.89
, Issue.2
, pp. 87-96
-
-
Pickar, J.G.1
-
9
-
-
0028868976
-
Responses of mechanosensitive afferents to manipulation of the lumbar facet in the cat
-
JG Pickar, and RF McLain Responses of mechanosensitive afferents to manipulation of the lumbar facet in the cat Spine 20 1995 2379 2385
-
(1995)
Spine
, vol.20
, pp. 2379-2385
-
-
Pickar, J.G.1
McLain, R.F.2
-
10
-
-
29844433280
-
Paraspinal muscle spindle responses to the duration of a spinal manipulation under force control
-
DOI 10.1016/j.jmpt.2005.11.014, PII S0161475405003568
-
JG Pickar, and YM Kang Paraspinal muscle spindle responses to the duration of a spinal manipulation under force control J Manipulative Physiol Ther 29 2006 22 31 (Pubitemid 43035545)
-
(2006)
Journal of Manipulative and Physiological Therapeutics
, vol.29
, Issue.1
, pp. 22-31
-
-
Pickar, J.G.1
Kang, Y.-M.2
-
11
-
-
18144373122
-
Comparison of human lumbar facet joint capsule strains during simulated high-velocity, low-amplitude spinal manipulation versus physiological motions
-
DOI 10.1016/j.spinee.2004.11.006, PII S1529943004009271
-
A Ianuzzi, and PS Khalsa Comparison of human lumbar facet joint capsule strains during simulated high-velocity, low-amplitude spinal manipulation versus physiological motions Spine J 5 2005 277 290 (Pubitemid 40613670)
-
(2005)
Spine Journal
, vol.5
, Issue.3
, pp. 277-290
-
-
Ianuzzi, A.1
Khalsa, P.S.2
-
12
-
-
77955113773
-
Validation of the cat as a model for the human lumbar spine during simulated high-velocity, low-amplitude spinal manipulation
-
A Ianuzzi, JG Pickar, and PS Khalsa Validation of the cat as a model for the human lumbar spine during simulated high-velocity, low-amplitude spinal manipulation J Biomech Eng 132 2010 071008
-
(2010)
J Biomech Eng
, vol.132
, pp. 071008
-
-
Ianuzzi, A.1
Pickar, J.G.2
Khalsa, P.S.3
-
13
-
-
0029945075
-
Mechanical states encoded by stretch-sensitive neurons in feline joint capsule
-
PS Khalsa, AH Hoffman, and P Grigg Mechanical states encoded by stretch-sensitive neurons in feline joint capsule J Neurophysiol 76 1996 175 187 (Pubitemid 26251161)
-
(1996)
Journal of Neurophysiology
, vol.76
, Issue.1
, pp. 175-187
-
-
Khalsa, P.S.1
Hoffman, A.H.2
Grigg, P.3
-
14
-
-
16244411948
-
Material properties of the human lumbar facet joint capsule
-
DOI 10.1115/1.1835348
-
JS Little, and PS Khalsa Material properties of the human lumbar facet joint capsule J Biomech Eng 127 2005 15 24 (Pubitemid 40463477)
-
(2005)
Journal of Biomechanical Engineering
, vol.127
, Issue.1
, pp. 15-24
-
-
Little, J.S.1
Khalsa, P.S.2
-
15
-
-
57849157799
-
Determination of torque-limits for human and cat lumbar spine specimens during displacement-controlled physiological motions
-
A Ianuzzi, JG Pickar, and PS Khalsa Determination of torque-limits for human and cat lumbar spine specimens during displacement-controlled physiological motions Spine J 9 2009 77 86
-
(2009)
Spine J
, vol.9
, pp. 77-86
-
-
Ianuzzi, A.1
Pickar, J.G.2
Khalsa, P.S.3
-
16
-
-
1542379027
-
Human lumbar facet joint capsule strains: II. Alteration of strains subsequent to anterior interbody fixation
-
DOI 10.1016/j.spinee.2003.07.002, PII S1529943003004613
-
JS Little, A Ianuzzi, JB Chiu, A Baitner, and PS Khalsa Human lumbar facet joint capsule strains: II. Alteration of strains subsequent to anterior interbody fixation Spine J. 4 2004 153 162 (Pubitemid 38304993)
-
(2004)
Spine Journal
, vol.4
, Issue.2
, pp. 153-162
-
-
Little, J.S.1
Ianuzzi, A.2
Chiu, J.B.3
Baitner, A.4
Khalsa, P.S.5
-
17
-
-
17444410040
-
Human lumbar spine creep during cyclic and static flexion: Creep rate, biomechanics, and facet joint capsule strain
-
DOI 10.1007/s10439-005-1742-x
-
JS Little, and PS Khalsa Human lumbar spine creep during cyclic and static flexion: creep rate, biomechanics, and facet joint capsule strain Ann Biomed Eng 33 2005 391 401 (Pubitemid 40536671)
-
(2005)
Annals of Biomedical Engineering
, vol.33
, Issue.3
, pp. 391-401
-
-
Little, J.S.1
Khalsa, P.S.2
-
18
-
-
33747373141
-
Biomechanical evaluation of surgical constructs for stabilization of cervical teardrop fractures
-
A Ianuzzi, I Zambrano, J Tataria, A Ameerally, M Agulnick, and JS Goodwin Biomechanical evaluation of surgical constructs for stabilization of cervical teardrop fractures Spine J 6 2006 514 523
-
(2006)
Spine J
, vol.6
, pp. 514-523
-
-
Ianuzzi, A.1
Zambrano, I.2
Tataria, J.3
Ameerally, A.4
Agulnick, M.5
Goodwin, J.S.6
-
19
-
-
0028043939
-
Comparison of in vivo and in vitro adjacent segment motion after lumbar fusion
-
DOI 10.1097/00007632-199408000-00015
-
MB Dekutoski, MJ Schendel, JW Ogilvie, JM Olsewski, LJ Wallace, and JL Lewis Comparison of in vivo and in vitro adjacent segment motion after lumbar fusion Spine (Phila Pa 1976) 19 1994 1745 1751 (Pubitemid 24314184)
-
(1994)
Spine
, vol.19
, Issue.15
, pp. 1745-1751
-
-
Dekutoski, M.B.1
Schendel, M.J.2
Ogilvie, J.W.3
Olsewski, J.M.4
Wallace, L.J.5
Lewis, J.L.6
-
20
-
-
0027897660
-
Determining the movements of the skeleton using well-configured markers
-
I Soderkvist, and PA Wedin Determining the movements of the skeleton using well-configured markers J Biomech 26 1993 1473 1477
-
(1993)
J Biomech
, vol.26
, pp. 1473-1477
-
-
Soderkvist, I.1
Wedin, P.A.2
-
21
-
-
0034740598
-
Computer aided speckle interferometry: A technique for measuring deformation of the surface of the heart
-
DOI 10.1114/1.1397785
-
GR Gaudette, J Todaro, IB Krukenkamp, and FP Chiang Computer aided speckle interferometry: a technique for measuring deformation of the surface of the heart Ann Biomed Eng 29 2001 775 780 (Pubitemid 33013700)
-
(2001)
Annals of Biomedical Engineering
, vol.29
, Issue.9
, pp. 775-780
-
-
Gaudette, G.R.1
Todaro, J.2
Krukenkamp, I.B.3
Chiang, F.-P.4
-
22
-
-
0023878086
-
High-precision three-dimensional photogrammetric calibration and object space reconstruction using a modified DLT-approach
-
H Hatze High-precision three-dimensional photogrammetric calibration and object space reconstruction using a modified DLT-approach J Biomech 21 1988 533 538
-
(1988)
J Biomech
, vol.21
, pp. 533-538
-
-
Hatze, H.1
-
23
-
-
0034657282
-
The cervical facet capsule and its role in whiplash injury: A biomechanical investigation
-
DOI 10.1097/00007632-200005150-00007
-
BA Winkelstein, RW Nightingale, WJ Richardson, and BS Myers The cervical facet capsule and its role in whiplash injury: a biomechanical investigation Spine 25 2000 1238 1246 (Pubitemid 30322314)
-
(2000)
Spine
, vol.25
, Issue.10
, pp. 1238-1246
-
-
Winkelstein, B.A.1
Nightingale, R.W.2
Richardson, W.J.3
Myers, B.S.4
-
24
-
-
28644439524
-
High loading rate during spinal manipulation produces unique facet joint capsule strain patterns compared with axial rotations
-
DOI 10.1016/j.jmpt.2005.08.020, PII S0161475405003234
-
A Ianuzzi, and PS Khalsa High loading rate during spinal manipulation produces unique facet joint capsule strain patterns compared with axial rotations J Manipulative Physiol Ther 28 2005 673 687 (Pubitemid 41750953)
-
(2005)
Journal of Manipulative and Physiological Therapeutics
, vol.28
, Issue.9
, pp. 673-687
-
-
Ianuzzi, A.1
Khalsa, P.S.2
-
25
-
-
4243310172
-
Mixing continuous and categorical variables: Analysis of covariance
-
McGraw-Hill, Inc. New York
-
SA Glantz, and BK Slinker Mixing continuous and categorical variables: analysis of covariance Primer of applied regression and analysis of variance Vol 2 2004 McGraw-Hill, Inc. New York 241 273
-
(2004)
Primer of Applied Regression and Analysis of Variance
, vol.2
, pp. 241-273
-
-
Glantz, S.A.1
Slinker, B.K.2
-
26
-
-
0031885419
-
The cat vertebral column: Stance configuration and range of motion
-
DOI 10.1007/s002210050348
-
JM Macpherson, and Y Ye The cat vertebral column: stance configuration and range of motion Exp Brain Res 119 1998 324 332 (Pubitemid 28118740)
-
(1998)
Experimental Brain Research
, vol.119
, Issue.3
, pp. 324-332
-
-
Macpherson, J.M.1
Ye, Y.2
-
27
-
-
0028350725
-
Mechanical behavior of the human lumbar and lumbosacral spine as shown by three-dimensional load-displacement curves
-
MM Panjabi, TR Oxland, I Yamamoto, and JJ Crisco Mechanical behavior of the human lumbar and lumbosacral spine as shown by three-dimensional load-displacement curves J Bone Joint Surg Am 76 1994 413 424 (Pubitemid 24138935)
-
(1994)
Journal of Bone and Joint Surgery - Series A
, vol.76
, Issue.3
, pp. 413-424
-
-
Panjabi, M.M.1
Oxland, T.R.2
Yamamoto, I.3
Crisco, J.J.4
-
28
-
-
21844459470
-
Neurophysiological and biomechanical characterization of goat cervical facet joint capsules
-
DOI 10.1016/j.orthres.2005.01.002, PII S0736026605000094
-
Y Lu, C Chen, S Kallakuri, A Patwardhan, and JM Cavanaugh Neurophysiological and biomechanical characterization of goat cervical facet joint capsules J Orthop Res 23 2005 779 787 (Pubitemid 40960028)
-
(2005)
Journal of Orthopaedic Research
, vol.23
, Issue.4
, pp. 779-787
-
-
Lu, Y.1
Chen, C.2
Kallakuri, S.3
Patwardhan, A.4
Cavanaugh, J.M.5
-
29
-
-
28744446946
-
Musculoskeletal examination for somatic dysfunction
-
RC Ward, RJ Hruby, JA Jerome, JM Jones, RE Kappler, Lippincott Williams & Wilkins
-
WA Kuchera, and RE Kappler Musculoskeletal examination for somatic dysfunction RC Ward, RJ Hruby, JA Jerome, JM Jones, RE Kappler, Foundations for osteopathic medicine 2002 Lippincott Williams & Wilkins 633 659
-
(2002)
Foundations for Osteopathic Medicine
, pp. 633-659
-
-
Kuchera, W.A.1
Kappler, R.E.2
-
30
-
-
80052266545
-
Documentation and record keeping
-
S Halderman, S Dagenais, B Budgell, McGraw-Hill New York
-
L Sportelli, and G Tarola Documentation and record keeping S Halderman, S Dagenais, B Budgell, Principles and practice of chiropractic 2005 McGraw-Hill New York 725 741
-
(2005)
Principles and Practice of Chiropractic
, pp. 725-741
-
-
Sportelli, L.1
Tarola, G.2
-
32
-
-
33746883122
-
A quantitative analysis of strain at adjacent segments after segmental immobilization of the cervical spine
-
DOI 10.1097/00024720-200608000-00006, PII 0002472020060800000006
-
AA Ragab, AJ Escarcega, and TA Zdeblick A quantitative analysis of strain at adjacent segments after segmental immobilization of the cervical spine J Spinal Disord Tech 19 2006 407 410 (Pubitemid 44197591)
-
(2006)
Journal of Spinal Disorders and Techniques
, vol.19
, Issue.6
, pp. 407-410
-
-
Ragab, A.A.1
Escarcega, A.J.2
Zdeblick, T.A.3
-
33
-
-
0032168970
-
The ability of lumbar medial branch blocks to anesthetize the zygapophysial joint: A physiologic challenge
-
DOI 10.1097/00007632-199809010-00008
-
M Kaplan, P Dreyfuss, B Halbrook, and N Bogduk The ability of lumbar medial branch blocks to anesthetize the zygapophysial joint. A physiologic challenge Spine (Phila Pa 1976) 23 1998 1847 1852 (Pubitemid 28432480)
-
(1998)
Spine
, vol.23
, Issue.17
, pp. 1847-1852
-
-
Kaplan, M.1
Dreyfuss, P.2
Halbrook, B.3
Bogduk, N.4
-
34
-
-
0036214369
-
The use of a quadruped as an in vivo model for the study of the spine - Biomechanical considerations
-
DOI 10.1007/s005860100346
-
TH Smit The use of a quadruped as an in vivo model for the study of the spine-biomechanical considerations Eur Spine J 11 2002 137 144 (Pubitemid 34328116)
-
(2002)
European Spine Journal
, vol.11
, Issue.2
, pp. 137-144
-
-
Smit, T.H.1
|