-
1
-
-
2342430033
-
Efficacy of spinal manipulation and mobilization for low back pain and neck pain: A systematic review and best evidence synthesis
-
G Bronfort, M Haas, RL Evans, and LM Bouter Efficacy of spinal manipulation and mobilization for low back pain and neck pain: a systematic review and best evidence synthesis Spine J 4 2004 335 356
-
(2004)
Spine J
, vol.4
, pp. 335-356
-
-
Bronfort, G.1
Haas, M.2
Evans, R.L.3
Bouter, L.M.4
-
2
-
-
0032948805
-
Spinal manipulation: Current state of research and its indications
-
G Bronfort Spinal manipulation: current state of research and its indications Neurol Clin 17 1999 91 111
-
(1999)
Neurol Clin
, vol.17
, pp. 91-111
-
-
Bronfort, G.1
-
3
-
-
0036759028
-
Neurophysiological effects of spinal manipulation
-
JG Pickar Neurophysiological effects of spinal manipulation Spine J 1 2002 357 371
-
(2002)
Spine J
, vol.1
, pp. 357-371
-
-
Pickar, J.G.1
-
4
-
-
2942581321
-
Central neuronal plasticity, low back pain and spinal manipulative therapy
-
RW Boal, and RG Gillette Central neuronal plasticity, low back pain and spinal manipulative therapy J Manipulative Physiol Ther 27 2004 314 326
-
(2004)
J Manipulative Physiol Ther
, vol.27
, pp. 314-326
-
-
Boal, R.W.1
Gillette, R.G.2
-
5
-
-
0024670467
-
Sensory innervation of soft tissues of the lumbar spine in the rat
-
JM Cavanaugh, A el Bohy, WN Hardy, TV Getchell, ML Getchell, and AI King Sensory innervation of soft tissues of the lumbar spine in the rat J Orthop Res 7 1989 378 388
-
(1989)
J Orthop Res
, vol.7
, pp. 378-388
-
-
Cavanaugh, J.M.1
El Bohy, A.2
Hardy, W.N.3
Getchell, T.V.4
Getchell, M.L.5
King, A.I.6
-
6
-
-
0029981638
-
A morphological study of the fibrous capsule of the human lumbar facet joint
-
T Yamashita, Y Minaki, AC Ozaktay, JM Cavanaugh, and AI King A morphological study of the fibrous capsule of the human lumbar facet joint Spine 21 1996 538 543
-
(1996)
Spine
, vol.21
, pp. 538-543
-
-
Yamashita, T.1
Minaki, Y.2
Ozaktay, A.C.3
Cavanaugh, J.M.4
King, A.I.5
-
7
-
-
0029945075
-
Mechanical states encoded by stretch-sensitive neurons in feline joint capsule
-
PS Khalsa, AH Hoffman, and P Grigg Mechanical states encoded by stretch-sensitive neurons in feline joint capsule J Neurophysiol 76 1996 175 187
-
(1996)
J Neurophysiol
, vol.76
, pp. 175-187
-
-
Khalsa, P.S.1
Hoffman, A.H.2
Grigg, P.3
-
8
-
-
16244411948
-
Material properties of the human lumbar facet joint capsule
-
JS Little, and PS Khalsa Material properties of the human lumbar facet joint capsule J Biomech Eng 127 2005 15 24
-
(2005)
J Biomech Eng
, vol.127
, pp. 15-24
-
-
Little, J.S.1
Khalsa, P.S.2
-
9
-
-
1542379027
-
Human lumbar facet joint capsule strains: II. Alteration of strains subsequent to anterior interbody fixation
-
JS Little, A Ianuzzi, JB Chiu, A Baitner, and PS Khalsa Human lumbar facet joint capsule strains: II. Alteration of strains subsequent to anterior interbody fixation Spine J 4 2004 153 162
-
(2004)
Spine J
, vol.4
, pp. 153-162
-
-
Little, J.S.1
Ianuzzi, A.2
Chiu, J.B.3
Baitner, A.4
Khalsa, P.S.5
-
10
-
-
17444410040
-
Human lumbar spine creep during cyclic and static flexion: Creep rate, biomechanics, and facet joint capsule strain
-
JS Little, and PS Khalsa Human lumbar spine creep during cyclic and static flexion: creep rate, biomechanics, and facet joint capsule strain Ann Biomed Eng 33 2005 391 401
-
(2005)
Ann Biomed Eng
, vol.33
, pp. 391-401
-
-
Little, J.S.1
Khalsa, P.S.2
-
11
-
-
1542289037
-
Human lumbar facet joint capsule strains: I. during physiological motions
-
A Ianuzzi, JS Little, JB Chiu, A Baitner, G Kawchuk, and PS Khalsa Human lumbar facet joint capsule strains: I. During physiological motions Spine J 4 2004 141 152
-
(2004)
Spine J
, vol.4
, pp. 141-152
-
-
Ianuzzi, A.1
Little, J.S.2
Chiu, J.B.3
Baitner, A.4
Kawchuk, G.5
Khalsa, P.S.6
-
12
-
-
18144373122
-
Comparison of human lumbar facet joint capsule strains during simulated high-velocity, low-amplitude spinal manipulation versus physiological motions
-
A Ianuzzi, and PS Khalsa Comparison of human lumbar facet joint capsule strains during simulated high-velocity, low-amplitude spinal manipulation versus physiological motions Spine J 5 2005 277 290
-
(2005)
Spine J
, vol.5
, pp. 277-290
-
-
Ianuzzi, A.1
Khalsa, P.S.2
-
13
-
-
0036126933
-
Long-term effectiveness of bone-setting, light exercise therapy, and physiotherapy for prolonged back pain: A randomized controlled trial
-
HM Hemmila, SM Keinanen-Kiukaanniemi, S Levoska, and P Puska Long-term effectiveness of bone-setting, light exercise therapy, and physiotherapy for prolonged back pain: a randomized controlled trial J Manipulative Physiol Ther 25 2002 99 104
-
(2002)
J Manipulative Physiol Ther
, vol.25
, pp. 99-104
-
-
Hemmila, H.M.1
Keinanen-Kiukaanniemi, S.M.2
Levoska, S.3
Puska, P.4
-
14
-
-
0027055510
-
The effects of controlled mechanical loading on group-II, III, and IV afferent units from the lumbar facet joint and surrounding tissue. An in vitro study
-
AI Avramov, JM Cavanaugh, CA Ozaktay, TV Getchell, and AI King The effects of controlled mechanical loading on group-II, III, and IV afferent units from the lumbar facet joint and surrounding tissue. An in vitro study J Bone Joint Surg Am 74 1992 1464 1471
-
(1992)
J Bone Joint Surg Am
, vol.74
, pp. 1464-1471
-
-
Avramov, A.I.1
Cavanaugh, J.M.2
Ozaktay, C.A.3
Getchell, T.V.4
King, A.I.5
-
16
-
-
0022354031
-
Biomechanical time-tolerance of fresh cadaveric human spine specimens
-
MM Panjabi, M Krag, D Summers, and T Videman Biomechanical time-tolerance of fresh cadaveric human spine specimens J Orthop Res 3 1985 292 300
-
(1985)
J Orthop Res
, vol.3
, pp. 292-300
-
-
Panjabi, M.M.1
Krag, M.2
Summers, D.3
Videman, T.4
-
17
-
-
0031425511
-
Loads transmitted during lumbosacral spinal manipulative therapy
-
J Triano, and AB Schultz Loads transmitted during lumbosacral spinal manipulative therapy Spine 22 1997 1955 1964
-
(1997)
Spine
, vol.22
, pp. 1955-1964
-
-
Triano, J.1
Schultz, A.B.2
-
18
-
-
0027897660
-
Determining the movements of the skeleton using well-configured markers
-
I Soderkvist, and PA Wedin Determining the movements of the skeleton using well-configured markers J Biomech 26 1993 1473 1477
-
(1993)
J Biomech
, vol.26
, pp. 1473-1477
-
-
Soderkvist, I.1
Wedin, P.A.2
-
19
-
-
0034657282
-
The cervical facet capsule and its role in whiplash injury: A biomechanical investigation
-
BA Winkelstein, RW Nightingale, WJ Richardson, and BS Myers The cervical facet capsule and its role in whiplash injury: a biomechanical investigation Spine 25 2000 1238 1246
-
(2000)
Spine
, vol.25
, pp. 1238-1246
-
-
Winkelstein, B.A.1
Nightingale, R.W.2
Richardson, W.J.3
Myers, B.S.4
-
20
-
-
0642279148
-
An electromyographic study of isokinetic axial rotation in young adults
-
S Kumar, Y Narayan, and D Garand An electromyographic study of isokinetic axial rotation in young adults Spine J 3 2003 46 54
-
(2003)
Spine J
, vol.3
, pp. 46-54
-
-
Kumar, S.1
Narayan, Y.2
Garand, D.3
-
21
-
-
0031423174
-
Axial rotation strength in seated neutral and prerotated postures of young adults
-
S Kumar Axial rotation strength in seated neutral and prerotated postures of young adults Spine 22 1997 2213 2221
-
(1997)
Spine
, vol.22
, pp. 2213-2221
-
-
Kumar, S.1
-
22
-
-
0028350725
-
Mechanical behavior of the human lumbar and lumbosacral spine as shown by three-dimensional load-displacement curves
-
MM Panjabi, TR Oxl, I Yamamoto, and JJ Crisco Mechanical behavior of the human lumbar and lumbosacral spine as shown by three-dimensional load-displacement curves J Bone Joint Surg Am 76 1994 413 424
-
(1994)
J Bone Joint Surg Am
, vol.76
, pp. 413-424
-
-
Panjabi, M.M.1
Oxl, T.R.2
Yamamoto, I.3
Crisco, J.J.4
-
23
-
-
0029080254
-
In vivo axial rotations and neutral zones of the thoracolumbar spine
-
S Kumar, and MM Panjabi In vivo axial rotations and neutral zones of the thoracolumbar spine J Spinal Disord 8 1995 253 263
-
(1995)
J Spinal Disord
, vol.8
, pp. 253-263
-
-
Kumar, S.1
Panjabi, M.M.2
-
24
-
-
0023090649
-
Method and instrument for noninvasive measurements of thoracolumbar rotation
-
G Mellin Method and instrument for noninvasive measurements of thoracolumbar rotation Spine 12 1987 28 31
-
(1987)
Spine
, vol.12
, pp. 28-31
-
-
Mellin, G.1
-
25
-
-
84939081906
-
Motion of the lumbar spine. Reliability of two measurement techniques
-
J Dillard, J Trafimow, GB Andersson, and K Cronin Motion of the lumbar spine. Reliability of two measurement techniques Spine 16 1991 321 324
-
(1991)
Spine
, vol.16
, pp. 321-324
-
-
Dillard, J.1
Trafimow, J.2
Andersson, G.B.3
Cronin, K.4
-
26
-
-
0031748960
-
Three-dimensional kinematics and trunk muscle myoelectric activity in the young lumbar spine: A database
-
JP Peach, CG Sutarno, and SM McGill Three-dimensional kinematics and trunk muscle myoelectric activity in the young lumbar spine: a database Arch Phys Med Rehabil 79 1998 663 669
-
(1998)
Arch Phys Med Rehabil
, vol.79
, pp. 663-669
-
-
Peach, J.P.1
Sutarno, C.G.2
McGill, S.M.3
-
27
-
-
0034517374
-
Three-dimensional lumbar spinal kinematics: A study of range of movement in 100 healthy subjects aged 20 to 60+ years
-
G Van Herp, P Rowe, P Salter, and JP Paul Three-dimensional lumbar spinal kinematics: a study of range of movement in 100 healthy subjects aged 20 to 60+ years Rheumatology (Oxford) 39 2000 1337 1340
-
(2000)
Rheumatology (Oxford)
, vol.39
, pp. 1337-1340
-
-
Van Herp, G.1
Rowe, P.2
Salter, P.3
Paul, J.P.4
-
28
-
-
0035165361
-
Range of motion and lordosis of the lumbar spine: Reliability of measurement and normative values
-
JK Ng, V Kippers, CA Richardson, and M Parnianpour Range of motion and lordosis of the lumbar spine: reliability of measurement and normative values Spine 26 2001 53 60
-
(2001)
Spine
, vol.26
, pp. 53-60
-
-
Ng, J.K.1
Kippers, V.2
Richardson, C.A.3
Parnianpour, M.4
-
29
-
-
0242410850
-
A real-time gyroscopic system for three-dimensional measurement of lumbar spine motion
-
RY Lee, J Laprade, and EH Fung A real-time gyroscopic system for three-dimensional measurement of lumbar spine motion Med Eng Phys 25 2003 817 824
-
(2003)
Med Eng Phys
, vol.25
, pp. 817-824
-
-
Lee, R.Y.1
Laprade, J.2
Fung, E.H.3
-
30
-
-
0015759592
-
Regional rotation of the spine
-
WY Loebl Regional rotation of the spine Rheumatol Rehabil 12 1973 223
-
(1973)
Rheumatol Rehabil
, vol.12
, pp. 223
-
-
Loebl, W.Y.1
-
31
-
-
0019207071
-
Sagittal and horizontal plane movement of the human lumbar vertebral column in cadavers and in the living
-
J Taylor, and L Twomey Sagittal and horizontal plane movement of the human lumbar vertebral column in cadavers and in the living Rheumatol Rehabil 19 1980 223 232
-
(1980)
Rheumatol Rehabil
, vol.19
, pp. 223-232
-
-
Taylor, J.1
Twomey, L.2
-
32
-
-
0022479637
-
Quantification of lumbar function. Part 5: Reliability of range-of-motion measures in the sagittal plane and an in vivo torso rotation measurement technique
-
J Keeley, TG Mayer, R Cox, RJ Gatchel, J Smith, and V Mooney Quantification of lumbar function. Part 5: reliability of range-of-motion measures in the sagittal plane and an in vivo torso rotation measurement technique Spine 11 1986 31 35
-
(1986)
Spine
, vol.11
, pp. 31-35
-
-
Keeley, J.1
Mayer, T.G.2
Cox, R.3
Gatchel, R.J.4
Smith, J.5
Mooney, V.6
-
33
-
-
0026566821
-
Interexaminer reliability and discriminant validity of inclinometric measurement of lumbar rotation in chronic low-back pain patients and subjects without low-back pain
-
PD Boline, JC Keating, M Haas, and AV Anderson Interexaminer reliability and discriminant validity of inclinometric measurement of lumbar rotation in chronic low-back pain patients and subjects without low-back pain Spine 17 1992 335 388
-
(1992)
Spine
, vol.17
, pp. 335-388
-
-
Boline, P.D.1
Keating, J.C.2
Haas, M.3
Anderson, A.V.4
-
34
-
-
0028286809
-
Analysis of spine motion variability using a computerized goniometer compared to physical examination. a prospective clinical study
-
CA Dopf, SS Mandel, DF Geiger, and PJ Mayer Analysis of spine motion variability using a computerized goniometer compared to physical examination. A prospective clinical study Spine 19 1994 586 595
-
(1994)
Spine
, vol.19
, pp. 586-595
-
-
Dopf, C.A.1
Mandel, S.S.2
Geiger, D.F.3
Mayer, P.J.4
-
35
-
-
7944219818
-
Kinematic response of lumbar functional spinal units to axial torsion with and without superimposed compression and flexion/extension
-
H Haberl, PA Cripton, TE Orr, T Beutler, H Frei, and WR Lanksch Kinematic response of lumbar functional spinal units to axial torsion with and without superimposed compression and flexion/extension Eur Spine J 13 2004 560 566
-
(2004)
Eur Spine J
, vol.13
, pp. 560-566
-
-
Haberl, H.1
Cripton, P.A.2
Orr, T.E.3
Beutler, T.4
Frei, H.5
Lanksch, W.R.6
-
36
-
-
0019969097
-
Physiologic strains in the lumbar spinal ligaments. An in vitro biomechanical study 1981 Volvo Award in Biomechanics
-
MM Panjabi, VK Goel, and K Takata Physiologic strains in the lumbar spinal ligaments. An in vitro biomechanical study 1981 Volvo Award in Biomechanics Spine 7 1982 192 203
-
(1982)
Spine
, vol.7
, pp. 192-203
-
-
Panjabi, M.M.1
Goel, V.K.2
Takata, K.3
-
37
-
-
0034016462
-
Effects of specimen length on the monosegmental motion behavior of the lumbar spine
-
A Kettler, HJ Wilke, C Haid, and L Claes Effects of specimen length on the monosegmental motion behavior of the lumbar spine Spine 25 2000 543 550
-
(2000)
Spine
, vol.25
, pp. 543-550
-
-
Kettler, A.1
Wilke, H.J.2
Haid, C.3
Claes, L.4
-
38
-
-
0038617310
-
Efficacy of cervical endplay assessment as an indicator for spinal manipulation
-
M Haas, E Groupp, D Panzer, L Partna, S Lumsden, and M Aickin Efficacy of cervical endplay assessment as an indicator for spinal manipulation Spine 28 2003 1091 1096
-
(2003)
Spine
, vol.28
, pp. 1091-1096
-
-
Haas, M.1
Groupp, E.2
Panzer, D.3
Partna, L.4
Lumsden, S.5
Aickin, M.6
-
39
-
-
0033556113
-
Electromyographic responses of back and limb muscles associated with spinal manipulative therapy
-
W Herzog, D. Scheele, and PJ Conway Electromyographic responses of back and limb muscles associated with spinal manipulative therapy Spine 24 1999 146 152
-
(1999)
Spine
, vol.24
, pp. 146-152
-
-
Herzog, W.1
Scheele, D.2
Conway, P.J.3
|