메뉴 건너뛰기




Volumn 27, Issue 8, 2011, Pages 618-624

Epithelial thickness up to 26 years after radial keratotomy: Three-dimensional display with artemis very high-frequency digital ultrasound

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; CORNEA CURVATURE; CORNEA EPITHELIUM; CORNEA THICKNESS; ECHOOCULOGRAPHY; EPITHELIUM THICKNESS; HUMAN; IN VIVO STUDY; KERATOMETRY; MYOPIA; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RADIAL KERATOTOMY; THREE DIMENSIONAL IMAGING; ULTRASOUND SCANNER;

EID: 80052218603     PISSN: 1081597X     EISSN: 19382391     Source Type: Journal    
DOI: 10.3928/1081597X-20110125-01     Document Type: Article
Times cited : (32)

References (36)
  • 1
    • 33751033654 scopus 로고    scopus 로고
    • Combined Artemis very high-frequency digital ultrasound-assisted transepithelial phototherapeutic keratectomy and wavefront-guided treatment following multiple corneal refractive procedures
    • DOI 10.1016/j.jcrs.2006.07.016, PII S0886335006010467
    • Reinstein DZ, Archer T. Combined Artemis very high-frequency digital ultrasound-assisted transepithelial phototherapeutic keratectomy and wavefront-guided treatment following multiple corneal refractive procedures. J Cataract Refract Surg. 2006;32(11):1870-1876. (Pubitemid 44754918)
    • (2006) Journal of Cataract and Refractive Surgery , vol.32 , Issue.11 , pp. 1870-1876
    • Reinstein, D.Z.1    Archer, T.2
  • 2
    • 66149164458 scopus 로고    scopus 로고
    • Epithelial thickness profile changes induced by myopic LASIK as measured by Artemis very high-frequency digital ultrasound
    • Reinstein DZ, Srivannaboon S, Gobbe M, Archer TJ, Silverman RH, Sutton H, Coleman DJ. Epithelial thickness profile changes induced by myopic LASIK as measured by Artemis very high-frequency digital ultrasound. J Refract Surg. 2009;25(5):444-450.
    • (2009) J Refract Surg , vol.25 , Issue.5 , pp. 444-450
    • Reinstein, D.Z.1    Srivannaboon, S.2    Gobbe, M.3    Archer, T.J.4    Silverman, R.H.5    Sutton, H.6    Coleman, D.J.7
  • 4
    • 0033504309 scopus 로고    scopus 로고
    • Very high-frequency ultrasound corneal analysis identifies anatomic correlates of optical complications of lamellar refractive surgery: Anatomic diagnosis in lamellar surgery
    • Reinstein DZ, Silverman RH, Sutton HF, Coleman DJ. Very high-frequency ultrasound corneal analysis identifies anatomic correlates of optical complications of lamellar refractive surgery: anatomic diagnosis in lamellar surgery. Ophthalmology. 1999;106(3):474-482. (Pubitemid 30191580)
    • (1999) Ophthalmology , vol.106 , Issue.3 , pp. 474-482
    • Reinstein, D.Z.1    Silverman, R.H.2    Sutton, H.F.S.3    Coleman, D.J.4
  • 5
    • 0345515978 scopus 로고    scopus 로고
    • Regression after LASIK for the treatment of myopia: The role of the corneal epithelium
    • Lohmann CP, Guell JL. Regression after LASIK for the treatment of myopia: the role of the corneal epithelium. Semin Ophthalmol. 1998;13(2):79-82. (Pubitemid 28440468)
    • (1998) Seminars in Ophthalmology , vol.13 , Issue.2 , pp. 79-82
    • Lohmann, C.P.1    Guell, J.L.2
  • 6
    • 0036345780 scopus 로고    scopus 로고
    • Effect of myopic laser in situ keratomileusis on epithelial and stromal thickness: A confocal microscopy study
    • Erie JC, Patel SV, McLaren JW, Ramirez M, Hodge DO, Maguire LJ, Bourne WM. Effect of myopic laser in situ keratomileusis on epithelial and stromal thickness: a confocal microscopy study. Ophthalmology. 2002;109(8):1447-1452.
    • (2002) Ophthalmology , vol.109 , Issue.8 , pp. 1447-1452
    • Erie, J.C.1    Patel, S.V.2    McLaren, J.W.3    Ramirez, M.4    Hodge, D.O.5    Maguire, L.J.6    Bourne, W.M.7
  • 7
    • 0034115187 scopus 로고    scopus 로고
    • Role of the corneal epithelium in refractive changes following laser in situ keratomileusis for high myopia
    • Spadea L, Fasciani R, Necozione S, Balestrazzi E. Role of the corneal epithelium in refractive changes following laser in situ keratomileusis for high myopia. J Refract Surg. 2000;16(2):133-139. (Pubitemid 30202021)
    • (2000) Journal of Refractive Surgery , vol.16 , Issue.2 , pp. 133-139
    • Spadea, L.1    Fasciani, R.2    Necozione, S.3    Balestrazzi, E.4
  • 9
    • 0032924936 scopus 로고    scopus 로고
    • Regression and epithelial hyperplasia after myopic photorefractive keratectomy in a human cornea
    • DOI 10.1016/S0886-3350(99)00014-0, PII S0886335099000140
    • Lohmann CP, Reischl U, Marshall J. Regression and epithelial hyperplasia after myopic photorefractive keratectomy in a human cornea. J Cataract Refract Surg. 1999;25(5):712-715. (Pubitemid 29222605)
    • (1999) Journal of Cataract and Refractive Surgery , vol.25 , Issue.5 , pp. 712-715
    • Lohmann, C.P.1    Reischl, U.2    Marshall, J.3
  • 10
    • 25144453884 scopus 로고    scopus 로고
    • VHF digital ultrasound three-dimensional scanning in the diagnosis of myopic regression after corneal refractive surgery
    • Reinstein DZ, Ameline B, Puech M, Montefiore G, Laroche L. VHF digital ultrasound three-dimensional scanning in the diagnosis of myopic regression after corneal refractive surgery. J Refract Surg. 2005;21(5):480-484. (Pubitemid 41356292)
    • (2005) Journal of Refractive Surgery , vol.21 , Issue.5 , pp. 480-484
    • Reinstein, D.Z.1    Ameline, B.2    Puech, M.3    Montefiore, G.4    Laroche, L.5
  • 11
    • 34247269768 scopus 로고    scopus 로고
    • Confocal microscopy changes in epithelial and stromal thickness up to 7 years after LASIK and photorefractive keratectomy for myopia
    • Patel SV, Erie JC, McLaren JW, Bourne WM. Confocal microscopy changes in epithelial and stromal thickness up to 7 years after LASIK and photorefractive keratectomy for myopia. J Refract Surg. 2007;23(4):385-392. (Pubitemid 46608850)
    • (2007) Journal of Refractive Surgery , vol.23 , Issue.4 , pp. 385-392
    • Patel, S.V.1    Erie, J.C.2    McLaren, J.W.3    Bourne, W.M.4
  • 12
    • 0030274760 scopus 로고    scopus 로고
    • The importance of the corneal epithelium in excimer-laser photorefractive keratectomy
    • Lohmann CP, Patmore A, Reischl U, Marshall J. The importance of the corneal epithelium in excimer-laser photorefractive keratectomy. Ger J Ophthalmol. 1996;5(6):368-372.
    • (1996) Ger J Ophthalmol , vol.5 , Issue.6 , pp. 368-372
    • Lohmann, C.P.1    Patmore, A.2    Reischl, U.3    Marshall, J.4
  • 13
    • 78449242405 scopus 로고    scopus 로고
    • Epithelial thickness after hyperopic LASIK: Three-dimensional display with Artemis very high-frequency digital ultrasound
    • Reinstein DZ, Archer TJ, Gobbe M, Silverman RH, Coleman DJ. Epithelial thickness after hyperopic LASIK: three-dimensional display with Artemis very high-frequency digital ultrasound. J Refract Surg. 2010;26(8):555-564.
    • (2010) J Refract Surg , vol.26 , Issue.8 , pp. 555-564
    • Reinstein, D.Z.1    Archer, T.J.2    Gobbe, M.3    Silverman, R.H.4    Coleman, D.J.5
  • 14
    • 0035020018 scopus 로고    scopus 로고
    • Epithelial and stromal changes induced by Intacs examined by three-dimensional very high-frequency digital ultrasound
    • Reinstein DZ, Srivannaboon S, Holland SP. Epithelial and stromal changes induced by intacs examined by three-dimensional very high-frequency digital ultrasound. J Refract Surg. 2001;17(3):310-318. (Pubitemid 32487868)
    • (2001) Journal of Refractive Surgery , vol.17 , Issue.3 , pp. 310-318
    • Reinstein, D.Z.1    Srivannaboon, S.2    Holland, S.P.3
  • 16
    • 70350108665 scopus 로고    scopus 로고
    • Epithelial, stromal, and corneal pachymetry changes during orthokeratology
    • Reinstein DZ, Gobbe M, Archer TJ, Couch D, Bloom B. Epithelial, stromal, and corneal pachymetry changes during orthokeratology. Optom Vis Sci. 2009;86(8):E1006-E1014.
    • (2009) Optom Vis Sci , vol.86 , Issue.8
    • Reinstein, D.Z.1    Gobbe, M.2    Archer, T.J.3    Couch, D.4    Bloom, B.5
  • 18
    • 38549097581 scopus 로고    scopus 로고
    • Malleability of the ocular surface in response to mechanical stress induced by orthokeratology contact lenses
    • DOI 10.1097/ICO.0b013e318158b4b5, PII 0000322620080200000002
    • Lu F, Simpson T, Sorbara L, Fonn D. Malleability of the ocular surface in response to mechanical stress induced by orthokeratology contact lenses. Cornea. 2008;27(2):133-141. (Pubitemid 351158728)
    • (2008) Cornea , vol.27 , Issue.2 , pp. 133-141
    • Lu, F.1    Simpson, T.2    Sorbara, L.3    Fonn, D.4
  • 19
    • 0037343652 scopus 로고    scopus 로고
    • Corneal response to short-term orthokeratology lens wear
    • DOI 10.1097/00006324-200303000-00009
    • Sridharan R, Swarbrick H. Corneal response to short-term orthokeratology lens wear. Optom Vis Sci. 2003;80(3):200-206. (Pubitemid 36343244)
    • (2003) Optometry and Vision Science , vol.80 , Issue.3 , pp. 200-206
    • Sridharan, R.1    Swarbrick, H.2
  • 20
    • 49049098496 scopus 로고    scopus 로고
    • Epithelial thickness changes from the induction of myopia with CRTH RGP contact lenses
    • Haque S, Fonn D, Simpson T, Jones L. Epithelial thickness changes from the induction of myopia with CRTH RGP contact lenses. Invest Ophthalmol Vis Sci. 2008;49(8):3345-3350.
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , Issue.8 , pp. 3345-3350
    • Haque, S.1    Fonn, D.2    Simpson, T.3    Jones, L.4
  • 21
    • 34250745397 scopus 로고    scopus 로고
    • Artemis VHF digital ultrasound technology
    • Wang M, ed. Thorofare, NJ: SLACK Incorporated
    • Reinstein DZ, Silverman RH. Artemis VHF digital ultrasound technology. In: Wang M, ed. Corneal Topography in the Wavefront Era. Thorofare, NJ: SLACK Incorporated; 2006:207-226.
    • (2006) Corneal Topography in the Wavefront Era , pp. 207-226
    • Reinstein, D.Z.1    Silverman, R.H.2
  • 23
    • 67651073272 scopus 로고    scopus 로고
    • Evaluation of irregular astigmatism with Artemis very high-frequency digital ultrasound scanning
    • Wang M, ed. Thorofare, NJ: SLACK Incorporated
    • Reinstein DZ, Archer TJ. Evaluation of irregular astigmatism with Artemis very high-frequency digital ultrasound scanning. In: Wang M, ed. Irregular Astigmatism: Diagnosis and Treatment. Thorofare, NJ: SLACK Incorporated; 2007:29-42.
    • (2007) Irregular Astigmatism: Diagnosis and Treatment , pp. 29-42
    • Reinstein, D.Z.1    Archer, T.J.2
  • 24
    • 33751032366 scopus 로고    scopus 로고
    • Artemis very high-frequency digital ultrasound-guided repositioning of a free cap after laser in situ keratomileusis
    • Reinstein DZ, Rothman RC, Couch DG, Archer TJ. Artemis very high-frequency digital ultrasound-guided repositioning of a free cap after laser in situ keratomileusis. J Cataract Refract Surg. 2006;32(11):1877-1882.
    • (2006) J Cataract Refract Surg , vol.32 , Issue.11 , pp. 1877-1882
    • Reinstein, D.Z.1    Rothman, R.C.2    Couch, D.G.3    Archer, T.J.4
  • 25
    • 0026706360 scopus 로고
    • Histopathological variation in keratoconus
    • Scroggs MW, Proia AD. Histopathological variation in keratoconus. Cornea. 1992;11(6):553-559.
    • (1992) Cornea , vol.11 , Issue.6 , pp. 553-559
    • Scroggs, M.W.1    Proia, A.D.2
  • 26
    • 33646712980 scopus 로고    scopus 로고
    • Corneal and epithelial thickness in keratoconus: A comparison of ultrasonic pachymetry, Orbscan II, and optical coherence tomography
    • Haque S, Simpson T, Jones L. Corneal and epithelial thickness in keratoconus: a comparison of ultrasonic pachymetry, Orbscan II, and optical coherence tomography. J Refract Surg. 2006;22(5):486-493. (Pubitemid 43736477)
    • (2006) Journal of Refractive Surgery , vol.22 , Issue.5 , pp. 486-493
    • Haque, S.1    Simpson, T.2    Jones, L.3
  • 28
    • 77951062787 scopus 로고    scopus 로고
    • Epithelial, stromal, and corneal thickness in the keratoconic cornea: Three-dimensional display with Artemis very high-frequency digital ultrasound
    • Reinstein DZ, Archer TJ, Gobbe M, Silverman RH, Coleman DJ. Epithelial, stromal, and corneal thickness in the keratoconic cornea: three-dimensional display with Artemis very high-frequency digital ultrasound. J Refract Surg. 2010;26(7):259-271.
    • (2010) J Refract Surg , vol.26 , Issue.7 , pp. 259-271
    • Reinstein, D.Z.1    Archer, T.J.2    Gobbe, M.3    Silverman, R.H.4    Coleman, D.J.5
  • 29
    • 67651036588 scopus 로고    scopus 로고
    • Corneal epithelial thickness profile in the diagnosis of keratoconus
    • Reinstein DZ, Archer TJ, Gobbe M. Corneal epithelial thickness profile in the diagnosis of keratoconus. J Refract Surg. 2009;25(7):604-610.
    • (2009) J Refract Surg , vol.25 , Issue.7 , pp. 604-610
    • Reinstein, D.Z.1    Archer, T.J.2    Gobbe, M.3
  • 30
    • 0027427552 scopus 로고
    • High-frequency ultrasound measurement of the thickness of the corneal epithelium
    • Reinstein DZ, Silverman RH, Coleman DJ. High-frequency ultrasound measurement of the thickness of the corneal epithelium. Refract Corneal Surg. 1993;9(5):385-387. (Pubitemid 23300161)
    • (1993) Refractive and Corneal Surgery , vol.9 , Issue.5 , pp. 385-387
    • Reinstein, D.Z.1    Silverman, R.H.2    Coleman, D.J.3
  • 31
    • 0028084929 scopus 로고
    • Epithelial and corneal thickness measurements by high-frequency ultrasound digital signal processing
    • Reinstein DZ, Silverman RH, Rondeau MJ, Coleman DJ. Epithelial and corneal thickness measurements by high-frequency ultrasound digital signal processing. Ophthalmology. 1994;101(1):140-146. (Pubitemid 24044155)
    • (1994) Ophthalmology , vol.101 , Issue.1 , pp. 140-146
    • Reinstein, D.Z.1    Silverman, R.H.2    Rondeau, M.J.3    Coleman, D.J.4
  • 33
    • 45249084956 scopus 로고    scopus 로고
    • Epithelial thickness in the normal cornea: Three-dimensional display with artemis very high-frequency digital ultrasound
    • Reinstein DZ, Archer TJ, Gobbe M, Silverman RH, Coleman DJ. Epithelial thickness in the normal cornea: three-dimensional display with Artemis very high-frequency digital ultrasound. J Refract Surg. 2008;24(6):571-581. (Pubitemid 351842081)
    • (2008) Journal of Refractive Surgery , vol.24 , Issue.6 , pp. 571-581
    • Reinstein, D.Z.1    Archer, T.J.2    Gobbe, M.3    Silverman, R.H.4    Coleman, D.J.5
  • 34
    • 77957669157 scopus 로고    scopus 로고
    • Repeatability of layered corneal pachymetry with the Artemis very high-frequency digital ultrasound arc-scanner
    • Reinstein DZ, Archer TJ, Gobbe M, Silverman RH, Coleman DJ. Repeatability of layered corneal pachymetry with the Artemis very high-frequency digital ultrasound arc-scanner. J Refract Surg. 2010;26(9):646-659.
    • (2010) J Refract Surg , vol.26 , Issue.9 , pp. 646-659
    • Reinstein, D.Z.1    Archer, T.J.2    Gobbe, M.3    Silverman, R.H.4    Coleman, D.J.5
  • 35
    • 4444278818 scopus 로고    scopus 로고
    • Monitoring corneal structures with slitlamp-adapted optical coherence tomography in laser in situ keratomileusis
    • DOI 10.1016/j.jcrs.2004.01.035, PII S0886335004003475
    • Wirbelauer C, Pham DT. Monitoring corneal structures with slitlamp-adapted optical coherence tomography in laser in situ keratomileusis. J Cataract Refract Surg. 2004;30(9):1851-1860. (Pubitemid 39165913)
    • (2004) Journal of Cataract and Refractive Surgery , vol.30 , Issue.9 , pp. 1851-1860
    • Wirbelauer, C.1    Pham, D.T.2
  • 36
    • 3042580061 scopus 로고    scopus 로고
    • Noncontact measurements of central corneal epithelial and flap thickness after laser in situ keratomileusis
    • DOI 10.1167/iovs.03-1088
    • Wang J, Thomas J, Cox I, Rollins A. Noncontact measurements of central corneal epithelial and flap thickness after laser in situ keratomileusis. Invest Ophthalmol Vis Sci. 2004;45(6):1812-1816. (Pubitemid 38868976)
    • (2004) Investigative Ophthalmology and Visual Science , vol.45 , Issue.6 , pp. 1812-1816
    • Wang, J.1    Thomas, J.2    Cox, I.3    Rollins, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.