메뉴 건너뛰기




Volumn 18, Issue 4, 2011, Pages 462-470

Endograft accommodation on the aortic bifurcation: An overview of anatomical fixation and implications for long-term stent-graft stability

Author keywords

Abdominal aortic aneurysm; Anatomical fixation; Aortic bifurcation; Endovascular aneurysm repair; Fixation; Powerlink; Stent graft; Stent graft migration; Zenith composite

Indexed keywords

AORTA BIFURCATION; AORTA FLOW; ARTERY CATHETERIZATION; ARTERY PROSTHESIS; COMPARATIVE EFFECTIVENESS; ENDOGRAFT MIGRATION; ENDOLEAK; ENDOPROSTHESIS; EQUIPMENT DESIGN; FIXATION DEVICE; GRAFT FAILURE; HUMAN; PRIORITY JOURNAL; REVIEW; TISSUE DEGENERATION;

EID: 80052215328     PISSN: 15266028     EISSN: 15451550     Source Type: Journal    
DOI: 10.1583/11-3411.1     Document Type: Review
Times cited : (26)

References (49)
  • 1
    • 4544298467 scopus 로고    scopus 로고
    • Comparison of endovascular aneurysm repair with open repair in patients with abdominal aortic aneurysm (EVAR trial 1), 30-day operative mortality results: Randomised controlled trial
    • Greenhalgh RM, Brown LC, Kwong GP, et al. Comparison of endovascular aneurysm repair with open repair in patients with abdominal aortic aneurysm (EVAR trial 1), 30-day operative mortality results: randomised controlled trial. Lancet. 2004;364:843-848.
    • (2004) Lancet , vol.364 , pp. 843-848
    • Greenhalgh, R.M.1    Brown, L.C.2    Kwong, G.P.3
  • 2
    • 77952653434 scopus 로고    scopus 로고
    • Endovascular versus open repair of abdominal aortic aneurysm
    • United Kingdom EVAR Trial Investigators
    • United Kingdom EVAR Trial Investigators, Greenhalgh RM, Brown LC, et al. Endovascular versus open repair of abdominal aortic aneurysm. N Engl J Med. 2010;362:1863-1871.
    • (2010) N Engl J Med , vol.362 , pp. 1863-1871
    • Greenhalgh, R.M.1    Brown, L.C.2
  • 4
    • 77952628285 scopus 로고    scopus 로고
    • Long-term outcome of open or endovascular repair of abdominal aortic aneurysm
    • De Bruin JL, Baas AF, Buth J, et al. Long-term outcome of open or endovascular repair of abdominal aortic aneurysm. N Engl J Med. 2010;362:1881-1889.
    • (2010) N Engl J Med , vol.362 , pp. 1881-1889
    • De Bruin, J.L.1    Baas, A.F.2    Buth, J.3
  • 5
  • 9
    • 67349242782 scopus 로고    scopus 로고
    • The association between iliac fixation and proximal stent-graft migration during EVAR follow-up: Mid-term results of 154 Talent devices
    • Waasdorp EJ, de Vries JP, Sterkenburg A, et al. The association between iliac fixation and proximal stent-graft migration during EVAR follow-up: mid-term results of 154 Talent devices. Eur J Vasc Endovasc Surg. 2009;37:681-687.
    • (2009) Eur J Vasc Endovasc Surg , vol.37 , pp. 681-687
    • Waasdorp, E.J.1    De Vries, J.P.2    Sterkenburg, A.3
  • 10
    • 34848852449 scopus 로고    scopus 로고
    • Device-specific resistance to in vivo displacement of stent-grafts implanted with maximum iliac fixation
    • DOI 10.1583/1545-1550(2007)14[585:DRTIVD]2.0.CO;2
    • Murphy EH, Johnson ED, Arko FR. Device-specific resistance to in vivo displacement of stent-grafts implanted with maximum iliac fixation. J Endovasc Ther. 2007;14:585-592. (Pubitemid 350155007)
    • (2007) Journal of Endovascular Therapy , vol.14 , Issue.4 , pp. 585-592
    • Murphy, E.H.1    Johnson, E.D.2    Arko, F.R.3
  • 12
    • 77955401516 scopus 로고    scopus 로고
    • Contemporary results of endovascular repair of abdominal aortic aneurysms: Effect of anatomical fixation on outcomes
    • Carpenter JP, Garcia MJ, Harlin SA, et al. Contemporary results of endovascular repair of abdominal aortic aneurysms: effect of anatomical fixation on outcomes. J Endovasc Ther. 2010;17:153-162.
    • (2010) J Endovasc Ther , vol.17 , pp. 153-162
    • Carpenter, J.P.1    Garcia, M.J.2    Harlin, S.A.3
  • 13
    • 0033106035 scopus 로고    scopus 로고
    • Endovascular abdominal aortic aneurysm repair with percutaneous transfemoral prostheses deployment under local anaesthesia. Initial experience with a new, simple-to-use tubular and bifurcated device in the first 27 cases
    • DOI 10.1053/ejvs.1998.0748
    • Papazoglou K, Christu K, Iordanides T, et al. Endovascular abdominal aortic aneurysm repair with percutaneous transfemoral prostheses deployment under local anesthesia. Initial experience with a new, simple-to-use tubular and bifurcated device in the first 27 cases. Eur J Vasc Endovasc Surg. 1999;17:202-207. (Pubitemid 29108012)
    • (1999) European Journal of Vascular and Endovascular Surgery , vol.17 , Issue.3 , pp. 202-207
    • Papazoglou, K.1    Christu, K.2    Iordanides, T.3    Balitas, A.4    Giakoystides, D.5    Giakoystides, E.6    Papazoglou, O.7
  • 17
    • 0036481881 scopus 로고    scopus 로고
    • Device migration after endoluminal abdominal aortic aneurysm repair: Analysis of 113 cases with a minimum follow-up period of 2 years
    • DOI 10.1067/mva.2002.120045
    • Cao P, Verzini F, Zannetti S, et al. Device migration after endoluminal abdominal aortic aneurysm repair: analysis of 113 cases with a minimum follow-up period of 2 years. J Vasc Surg. 2002;35:229-235. (Pubitemid 44718623)
    • (2002) Journal of Vascular Surgery , vol.35 , Issue.2 , pp. 229-235
    • Cao, P.1    Verzini, F.2    Zannetti, S.3    De Rango, P.4    Parlani, G.5    Lupattelli, L.6    Maselli, A.7
  • 18
    • 34247402187 scopus 로고    scopus 로고
    • Five-year report of a multicenter controlled clinical trial of open versus endovascular treatment of abdominal aortic aneurysms
    • DOI 10.1016/j.jvs.2007.01.044, PII S0741521407000602
    • Peterson BG, Matsumura JS, Brewster DC, et al. Five-year report of a multicenter controlled clinical trial of open versus endovascular treatment of abdominal aortic aneurysms. J Vasc Surg. 2007;45:885-890. (Pubitemid 46634940)
    • (2007) Journal of Vascular Surgery , vol.45 , Issue.5 , pp. 885-890
    • Peterson, B.G.1    Matsumura, J.S.2    Brewster, D.C.3    Makaroun, M.S.4
  • 19
    • 12144274297 scopus 로고    scopus 로고
    • Endograft technology: Highlights of the past 10 years
    • Fogarty TJ, Arko FR, Zarins CK. Endograft technology: highlights of the past 10 years. J Endovasc Ther. 2004;11(Suppl II):II-192-II-199.
    • (2004) J Endovasc Ther , vol.11 , Issue.SUPPL. II
    • Fogarty, T.J.1    Arko, F.R.2    Zarins, C.K.3
  • 20
    • 4143152946 scopus 로고    scopus 로고
    • Stent-graft migration: How do we know when we have it and what is its significance?
    • DOI 10.1583/03-1142C.1
    • Zarins CK. Stent-graft migration: how do we know when we have it and what is its significance? [commentary] J Endovasc Ther. 2004;11:364-365. (Pubitemid 39096330)
    • (2004) Journal of Endovascular Therapy , vol.11 , Issue.4 , pp. 364-365
    • Zarins, C.K.1
  • 22
    • 68549115298 scopus 로고    scopus 로고
    • Effect of curvature on displacement forces acting on aortic endografts: A 3-dimensional computational analysis
    • Figueroa CA, Taylor CA, Yeh V, et al. Effect of curvature on displacement forces acting on aortic endografts: a 3-dimensional computational analysis. J Endovasc Ther. 2009;16:284-294.
    • (2009) J Endovasc Ther , vol.16 , pp. 284-294
    • Figueroa, C.A.1    Taylor, C.A.2    Yeh, V.3
  • 23
    • 77952207470 scopus 로고    scopus 로고
    • Preliminary 3D computational analysis of the relationship between aortic displacement force and direction of endograft movement
    • Figueroa CA, Taylor CA, Yeh V, et al. Preliminary 3D computational analysis of the relationship between aortic displacement force and direction of endograft movement. J Vasc Surg. 2010;51:1488-1497.
    • (2010) J Vasc Surg , vol.51 , pp. 1488-1497
    • Figueroa, C.A.1    Taylor, C.A.2    Yeh, V.3
  • 24
    • 84859165373 scopus 로고    scopus 로고
    • A computational study of the magnitude and direction of migration forces in patient-specific abdominal aortic aneurysm stent-grafts
    • Molony DS, Kavanagh EG, Madhavan P, et al. A computational study of the magnitude and direction of migration forces in patient-specific abdominal aortic aneurysm stent-grafts. Eur J Vasc Endovasc Surg. 2010;40:332-329.
    • (2010) Eur J Vasc Endovasc Surg , vol.40 , pp. 332-1329
    • Molony, D.S.1    Kavanagh, E.G.2    Madhavan, P.3
  • 25
    • 68249087423 scopus 로고    scopus 로고
    • A comparison of the mid-term results following the use of bifurcated and aorto-uni-iliac devices in the treatment of abdominal aortic aneurysms
    • Jean-Baptiste E, Batt M, Azzaoui R, et al. A comparison of the mid-term results following the use of bifurcated and aorto-uni-iliac devices in the treatment of abdominal aortic aneurysms. Eur J Vasc Endovasc Surg. 2009;38:298-304.
    • (2009) Eur J Vasc Endovasc Surg , vol.38 , pp. 298-304
    • Jean-Baptiste, E.1    Batt, M.2    Azzaoui, R.3
  • 26
    • 67649203185 scopus 로고    scopus 로고
    • Reporting mid- and long-term results of endovascular grafting for abdominal aortic aneurysms using the aortomonoiliac configuration
    • Lazaridis J, Melas N, Saratzis A, et al. Reporting mid- and long-term results of endovascular grafting for abdominal aortic aneurysms using the aortomonoiliac configuration. J Vasc Surg. 2009;50:8-14.
    • (2009) J Vasc Surg , vol.50 , pp. 8-14
    • Lazaridis, J.1    Melas, N.2    Saratzis, A.3
  • 27
    • 69849098517 scopus 로고    scopus 로고
    • Endovascular repair of abdominal aortic aneurysms: Only a mechanical solution for a biological problem?
    • Diehm N, Dick F, Katzen BT, et al. Endovascular repair of abdominal aortic aneurysms: only a mechanical solution for a biological problem? J Endovasc Ther. 2009;16(Suppl I):I119-I126.
    • (2009) J Endovasc Ther , vol.16 , Issue.SUPPL. I
    • Diehm, N.1    Dick, F.2    Katzen, B.T.3
  • 28
    • 35349001580 scopus 로고    scopus 로고
    • Use of aortic bifurcation for better graft stability: A new generation concept
    • Abstract
    • Stelter WJ. Use of aortic bifurcation for better graft stability: a new generation concept [Abstract]. J Endovasc Ther. 2002;9(suppl 1):e73.
    • (2002) J Endovasc Ther , vol.9 , Issue.SUPPL. 1
    • Stelter, W.J.1
  • 31
    • 80052225832 scopus 로고    scopus 로고
    • A new concept in EVAR. Anatomical fixation with the Powerlink stent-graft
    • May
    • Raithel D, Qu L, Hetzel G. A new concept in EVAR. Anatomical fixation with the Powerlink stent-graft. Endovasc Today. 2006 May:1-2.
    • (2006) Endovasc Today , pp. 1-2
    • Raithel, D.1    Qu, L.2    Hetzel, G.3
  • 32
    • 67650490741 scopus 로고    scopus 로고
    • From clinical trials to clinical practice: 612 cases treated with the Powerlink stent-graft for endovascular repair of AAA
    • Qu L, Raithel D. From clinical trials to clinical practice: 612 cases treated with the Powerlink stent-graft for endovascular repair of AAA. J Cardiovasc Surg (Torino). 2009;50:131-137.
    • (2009) J Cardiovasc Surg (Torino) , vol.50 , pp. 131-137
    • Qu, L.1    Raithel, D.2
  • 33
    • 0037003020 scopus 로고    scopus 로고
    • Multicenter trial of the PowerLink bifurcated system for endovascular aortic aneurysm repair
    • DOI 10.1067/mva.2002.129641
    • Carpenter JP, Endologix Investigators. Multicenter trial of the PowerLink bifurcated system for endovascular aortic aneurysm repair. J Vasc Surg. 2002;36:1129-1137. (Pubitemid 36236334)
    • (2002) Journal of Vascular Surgery , vol.36 , Issue.6 , pp. 1129-1137
    • Carpenter, J.P.1    Makaroun, M.S.2    Brener, B.J.3
  • 34
    • 8844238411 scopus 로고    scopus 로고
    • Midterm results of the multicenter trial of the powerlink bifurcated system for endovascular aortic aneurysm repair
    • DOI 10.1016/j.jvs.2004.08.051, PII S0741521404011462
    • Carpenter JP, Endologix Investigators. Midterm results of the multicenter trial of the Powerlink bifurcated system for endovascular aortic aneurysm repair. J Vasc Surg. 2004;40:849-859. (Pubitemid 39535212)
    • (2004) Journal of Vascular Surgery , vol.40 , Issue.5 , pp. 849-859
    • Carpenter, J.P.1
  • 35
    • 70350568629 scopus 로고    scopus 로고
    • Secure fixation following EVAR with the Powerlink XL system in wide aortic necks: Results of a prospective, multicenter trial
    • Jordan WD, Moore WM, Melton JG, et al. Secure fixation following EVAR with the Powerlink XL system in wide aortic necks: results of a prospective, multicenter trial. J Vasc Surg. 2009;50:979-986.
    • (2009) J Vasc Surg , vol.50 , pp. 979-986
    • Jordan, W.D.1    Moore, W.M.2    Melton, J.G.3
  • 36
    • 77956527199 scopus 로고    scopus 로고
    • Endovascular abdominal aortic aneurysm repair using an anatomical fixation technique and concomitant suprarenal orientation: Results of a prospective, multicenter trial
    • Harlin SA, Beasley RE, Feldman RL, et al. Endovascular abdominal aortic aneurysm repair using an anatomical fixation technique and concomitant suprarenal orientation: results of a prospective, multicenter trial. Ann Vasc Surg. 2010;24:921-929.
    • (2010) Ann Vasc Surg , vol.24 , pp. 921-929
    • Harlin, S.A.1    Beasley, R.E.2    Feldman, R.L.3
  • 37
    • 80052213332 scopus 로고    scopus 로고
    • Irvine, California, USA: Endologix
    • Powerlink System Users Report. Irvine, California, USA: Endologix; 2009.
    • (2009) Powerlink System Users Report
  • 38
    • 77955356899 scopus 로고    scopus 로고
    • Use of the IntuiTrak stent-graft delivery system for percutaneous abdominal aortic aneurysm exclusion: Initial single-center experience
    • TomCW, Krajcer Z. Use of the IntuiTrak stent-graft delivery system for percutaneous abdominal aortic aneurysm exclusion: initial single-center experience. Tex Heart Inst J. 2010;37:331-333.
    • (2010) Tex Heart Inst J , vol.37 , pp. 331-333
    • Tom, C.W.1    Krajcer, Z.2
  • 40
    • 33748873664 scopus 로고    scopus 로고
    • False endoleak image
    • Letter
    • Dalainas I, Nano G. False endoleak image [Letter]. J Endovasc Ther. 2006;13:566-567.
    • (2006) J Endovasc Ther , vol.13 , pp. 566-567
    • Dalainas, I.1    Nano, G.2
  • 41
    • 48249126783 scopus 로고    scopus 로고
    • Experience with the Endologix Powerlink endograft in endovascular repair of abdominal aortic aneurysms with short and angulated necks
    • Qu L, Raithel D. Experience with the Endologix Powerlink endograft in endovascular repair of abdominal aortic aneurysms with short and angulated necks. Perspect Vasc Surg Endovasc Ther. 2008;20:158-166.
    • (2008) Perspect Vasc Surg Endovasc Ther , vol.20 , pp. 158-166
    • Qu, L.1    Raithel, D.2
  • 42
    • 0141885377 scopus 로고    scopus 로고
    • Does hostile neck anatomy preclude successful endovascular aortic aneurysm repair?
    • Dillavou ED, Muluk SC, Rhee RY, et al. Does hostile neck anatomy preclude successful endovascular aortic aneurysm repair? J Vasc Surg. 2003;38:657-663.
    • (2003) J Vasc Surg , vol.38 , pp. 657-663
    • Dillavou, E.D.1    Muluk, S.C.2    Rhee, R.Y.3
  • 43
    • 32044445787 scopus 로고    scopus 로고
    • Outcomes of endovascular AAA repair in patients with hostile neck anatomy using adjunctive balloon-expandable stents
    • DOI 10.1177/153857440604000105
    • Cox DE, Jacobs DL, Motaganahalli RL, et al. Outcomes of endovascular AAA repair in patients with hostile neck anatomy using adjunctive balloon-expandable stents. Vasc Endovascular Surg. 2006;40:35-40. (Pubitemid 43201913)
    • (2006) Vascular and Endovascular Surgery , vol.40 , Issue.1 , pp. 35-40
    • Cox, D.E.1    Jacobs, D.L.2    Motaganahalli, R.L.3    Wittgen, C.M.4    Peterson, G.J.5
  • 44
    • 80052239581 scopus 로고    scopus 로고
    • Endograft fixation on the aortic bifurcation for better stability. Composite endoprosthesis
    • Perdikides T, Stelter WJ, Veith FJ, et al., eds. Paschalides Medical Publications: Athens, Greece
    • Perdikides T, Avgerinos ED, Tzilalis V, et al. Endograft fixation on the aortic bifurcation for better stability. Composite endoprosthesis. In: Perdikides T, Stelter WJ, Veith FJ, et al., eds. Advances in Endovascular Management of Abdominal Aortic Aneurysms. Paschalides Medical Publications: Athens, Greece; 2009:119-125.
    • (2009) Advances in Endovascular Management of Abdominal Aortic Aneurysms , pp. 119-125
    • Perdikides, T.1    Avgerinos, E.D.2    Tzilalis, V.3
  • 45
    • 49749097899 scopus 로고    scopus 로고
    • The Powerlink system for endovascular abdominal aortic aneurysm repair: Six-year results
    • Endologix Investigators
    • Wang GJ, Carpenter JP, Endologix Investigators. The Powerlink system for endovascular abdominal aortic aneurysm repair: six-year results. J Vasc Surg. 2008;48:535-545.e3.
    • (2008) J Vasc Surg , vol.48
    • Wang, G.J.1    Carpenter, J.P.2
  • 46
    • 55149100052 scopus 로고    scopus 로고
    • Endovascular treatment of abdominal aortic aneurysms with the Powerlink Endograft System: Influence of placement on the bifurcation and use of a proximal extension on early and late outcomes
    • Coppi G, Silingardi R, Tasselli S, et al. Endovascular treatment of abdominal aortic aneurysms with the Powerlink Endograft System: influence of placement on the bifurcation and use of a proximal extension on early and late outcomes. J Vasc Surg. 2008;48:795-801.
    • (2008) J Vasc Surg , vol.48 , pp. 795-801
    • Coppi, G.1    Silingardi, R.2    Tasselli, S.3
  • 47
    • 30744456283 scopus 로고    scopus 로고
    • Endovascular repair of abdominal aortic aneurysms with a unibody stent-graft: 3-Year results of the French powerlink multicenter trial
    • DOI 10.1583/05-1629R.1
    • Albertini JN, Lahlou Z, Magnan PE, et al. Endovascular repair of abdominal aortic aneurysms with a unibody stent-graft: 3-year results of the French Powerlink Multicenter Trial. J Endovasc Ther. 2005;12:629-637. (Pubitemid 43100918)
    • (2005) Journal of Endovascular Therapy , vol.12 , Issue.6 , pp. 629-637
    • Albertini, J.-N.1    Lahlou, Z.2    Magnan, P.-E.3    Branchereau, A.4
  • 48
    • 34250210474 scopus 로고    scopus 로고
    • The role of aortic neck dilation and elongation in the etiology of stent graft migration after endovascular abdominal aortic aneurysm repair with a passive fixation device
    • DOI 10.1016/j.jvs.2006.08.028, PII S0741521406014923
    • Litwinski RA, Donayre CE, Chow SL, et al. The role of aortic neck dilation and elongation in the etiology of stent graft migration after endovascular abdominal aortic aneurysm repair with a passive fixation device. J Vasc Surg. 2006;44:1176-1181. (Pubitemid 44828416)
    • (2006) Journal of Vascular Surgery , vol.44 , Issue.6 , pp. 1176-1181
    • Litwinski, R.A.1    Donayre, C.E.2    Chow, S.L.3    Song, T.K.4    Kopchok, G.5    Walot, I.6    White, R.A.7
  • 49
    • 47049131528 scopus 로고    scopus 로고
    • Lateral movement of endografts within the aneurysm sac is an indicator of stent-graft instability
    • DOI 10.1583/08-2422.1
    • Rafii BY, Abilez OJ, Benharash P, et al. Lateral movement of endografts within the aneurysm sac is an indicator of stent-graft instability. J Endovasc Ther. 2008;15:335-343. (Pubitemid 351969148)
    • (2008) Journal of Endovascular Therapy , vol.15 , Issue.3 , pp. 335-343
    • Rafii, B.Y.1    Abilez, O.J.2    Benharash, P.3    Zarins, C.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.