-
1
-
-
77649091668
-
AACE Diabetes Mellitus Clinical Practice Guidelines Task Force: American Association of Clinical Endocrinologists medical guidelines for clinical practice for the management of diabetes mellitus
-
Rodbard HW, Blonde L, Braithwaite SS, Brett EM, Cobin RH, Handelsman Y, Hellman R, Jellinger PS, Jovanovic LG, Levy P, Mechanick JI, Zangeneh F; AACE Diabetes Mellitus Clinical Practice Guidelines Task Force: American Association of Clinical Endocrinologists medical guidelines for clinical practice for the management of diabetes mellitus. Endocr Pract 2007;13(Suppl 1):1-68.
-
(2007)
Endocr Pract
, vol.13
, Issue.SUPPL. 1
, pp. 1-68
-
-
Rodbard, H.W.1
Blonde, L.2
Braithwaite, S.S.3
Brett, E.M.4
Cobin, R.H.5
Handelsman, Y.6
Hellman, R.7
Jellinger, P.S.8
Jovanovic, L.G.9
Levy, P.10
Mechanick, J.I.11
Zangeneh, F.12
-
2
-
-
80052044533
-
Global guideline for self-monitoring of blood glucose in non-insulin treated type 2 diabetes
-
International Diabetes Federation: Global Guideline for Self-Monitoring of Blood Glucose in Non-Insulin Treated Type 2 Diabetes. Brussels: International Diabetes Federation, 2009: 1-39.
-
(2009)
Brussels: International Diabetes Federation
, pp. 1-39
-
-
-
3
-
-
26844457935
-
The role of self-monitoring of blood glucose in the care of people with diabetes: Report of a global consensus conference
-
DOI 10.1016/j.amjmed.2005.07.055, PII S0002934305006625
-
rd: The role of self-monitoring of blood glucose in the care of people with diabetes: report of a global consensus conference. Am J Med 2005;118(Suppl 9A):1S-6S. (Pubitemid 41446936)
-
(2005)
American Journal of Medicine
, vol.118
, Issue.9 SUPPL.
-
-
Bergenstal, R.M.1
Gavin III, J.R.2
-
4
-
-
77950651886
-
Self-monitoring of blood glucose in type 2 diabetes: Systematic review
-
Clar C, Barnard K, Cummins E, Royle P, Waugh N: Self-monitoring of blood glucose in type 2 diabetes: systematic review. Health Technol Assess 2010;14(12):1-140.
-
(2010)
Health Technol Assess
, vol.14
, Issue.12
, pp. 1-140
-
-
Clar, C.1
Barnard, K.2
Cummins, E.3
Royle, P.4
Waugh, N.5
-
6
-
-
31044455219
-
Variability among five over-the-counter blood glucose monitors
-
DOI 10.1016/j.cca.2005.07.027, PII S0009898105005000
-
Kimberly MM, Vesper HW, Caudill SP, Ethridge SF, Archibold E, Porter KH, Myers GL: Variability among five over-the-counter blood glucose monitors. Clin Chim Acta 2006;364:292-297. (Pubitemid 43120657)
-
(2006)
Clinica Chimica Acta
, vol.364
, Issue.1-2
, pp. 292-297
-
-
Kimberly, M.M.1
Vesper, H.W.2
Caudill, S.P.3
Ethridge, S.F.4
Archibold, E.5
Porter, K.H.6
Myers, G.L.7
-
7
-
-
24144453866
-
Measurement variability between test strip lots on five hendheld glucose meter systems [abstract]
-
Louie R, Tang Z, Chang K, Kost G: Measurement variability between test strip lots on five hendheld glucose meter systems [abstract]. Clin Chem 2000;46(Suppl 6):A15.
-
(2000)
Clin Chem
, vol.46
, Issue.SUPPL. 6
-
-
Louie, R.1
Tang, Z.2
Chang, K.3
Kost, G.4
-
8
-
-
24144435337
-
Between-lot variation in external quality assessment of glucose: Clinical importance and effect on participant performance evaluation
-
DOI 10.1373/clinchem.2005.049080
-
Kristensen GB, Christensen NG, Thue G, Sandberg S: Between-lot variation in external quality assessment of glucose: clinical importance and effect on participant performance evaluation. Clin Chem 2005;51:1632-1636. (Pubitemid 41233098)
-
(2005)
Clinical Chemistry
, vol.51
, Issue.9
, pp. 1632-1636
-
-
Kristensen, G.B.B.1
Christensen, N.G.2
Thue, G.3
Sandberg, S.4
-
9
-
-
0023730224
-
Effect of temperature on blood/plasma glucose measurements with a portable reflectance meter
-
Barbour HM: Effect of temperature on blood/plasma glucose measurements with a portable reflectance meter. Clin Chem 1988;34:1918.
-
(1988)
Clin Chem
, vol.34
, pp. 1918
-
-
Barbour, H.M.1
-
10
-
-
0025484128
-
Effect of temperature on glucose results obtained with the Reflolux II
-
Ridgwell P, Holmes J: Effect of temperature on glucose results obtained with the Reflolux II. Clin Chem 1990;36: 1705-1706.
-
(1990)
Clin Chem
, vol.36
, pp. 1705-1706
-
-
Ridgwell, P.1
Holmes, J.2
-
11
-
-
0029084580
-
Accuracy of self-monitoring blood glucose meters in a high humidity, high temperature summer camp setting
-
Silverstein JH, House DV, Schatz DA, Kubilis P, Rosen-bloom A: Accuracy of self-monitoring blood glucose meters in a high humidity, high temperature summer camp setting. Diabetes Care 1995;18:1200-1201.
-
(1995)
Diabetes Care
, vol.18
, pp. 1200-1201
-
-
Silverstein, J.H.1
House, D.V.2
Schatz, D.A.3
Kubilis, P.4
Rosen-Bloom, A.5
-
12
-
-
0028956578
-
Effect of ambient temperature and humidity on performance of blood glucose meters
-
King JM, Eigenmann CA, Colagiuri S: Effect of ambient temperature and humidity on performance of blood glucose meters. Diabet Med 1995;12:337-340.
-
(1995)
Diabet Med
, vol.12
, pp. 337-340
-
-
King, J.M.1
Eigenmann, C.A.2
Colagiuri, S.3
-
13
-
-
0035515892
-
Effect of ambient temperature on analytical and clinical performance of a blood glucose monitoring system: Omnitest Sensor glucose meter
-
DOI 10.1258/0004563011901091
-
Nawawi H, Sazali BS, Kamaruzaman BH, Yazid TN, Jemain AA, Ismail F, Khalid BA: Effect of ambient temperature on analytical and clinical performance of a blood glucose monitoring system: Omnitest Sensor glucose meter. Ann Clin Biochem 2001;38:676-683. (Pubitemid 33702274)
-
(2001)
Annals of Clinical Biochemistry
, vol.38
, Issue.6
, pp. 676-683
-
-
Nawawi, H.1
Sazali, B.S.2
Kamaruzaman, B.H.3
Yazid, T.N.4
Jemain, A.A.5
Ismail, F.6
Khalid, B.A.K.7
-
14
-
-
60649086908
-
Assessing the quality of Bionime self-monitoring blood glucose system Rightest GM110: A critical evaluation of interference and ambient circumstances
-
Hsu CT, Hsiao HC, Lee MS, Chang SF, Lee TC, Tsai YS, Zen JM: Assessing the quality of Bionime self-monitoring blood glucose system Rightest GM110: a critical evaluation of interference and ambient circumstances. Clin Chim Acta 2009; 402:119-123.
-
(2009)
Clin Chim Acta
, vol.402
, pp. 119-123
-
-
Hsu, C.T.1
Hsiao, H.C.2
Lee, M.S.3
Chang, S.F.4
Lee, T.C.5
Tsai, Y.S.6
Zen, J.M.7
-
15
-
-
18144373408
-
Performance of glucose dehydrogenase- and glucose oxidase-based blood glucose meters at high altitude and low temperature [5]
-
DOI 10.2337/diacare.28.5.1261
-
Oberg D, Ostenson CG: Performance of glucose dehydro-genase-and glucose oxidase-based blood glucose meters at high altitude and low temperature. Diabetes Care 2005; 28:1261. (Pubitemid 40616654)
-
(2005)
Diabetes Care
, vol.28
, Issue.5
, pp. 1261
-
-
Oberg, D.1
Ostenson, C.-G.2
-
16
-
-
57349106743
-
Standardized evaluation of nine instruments for self-monitoring of blood glucose
-
Kristensen GB, Monsen G, Skeie S, Sandberg S: Standardized evaluation of nine instruments for self-monitoring of blood glucose. Diabetes Technol Ther 2008;10:467-477.
-
(2008)
Diabetes Technol Ther
, vol.10
, pp. 467-477
-
-
Kristensen, G.B.1
Monsen, G.2
Skeie, S.3
Sandberg, S.4
-
17
-
-
0035130886
-
Quality specifications for glucose meters: Assessment by simulation modeling of errors in insulin dose
-
Boyd JC, Bruns DE: Quality specifications for glucose meters: assessment by simulation modeling of errors in insulin dose. Clin Chem 2001;47:209-214. (Pubitemid 32142918)
-
(2001)
Clinical Chemistry
, vol.47
, Issue.2
, pp. 209-214
-
-
Boyd, J.C.1
Bruns, D.E.2
-
18
-
-
0035148237
-
Patient-derived quality specifications for instruments used in self-monitoring of blood glucose
-
Skeie S, Thue G, Sandberg S: Patient-derived quality specifications for instruments used in self-monitoring of blood glucose. Clin Chem 2001;47:67-73. (Pubitemid 32064277)
-
(2001)
Clinical Chemistry
, vol.47
, Issue.1
, pp. 67-73
-
-
Skeie, S.1
Thue, G.2
Sandberg, S.3
-
19
-
-
0016585365
-
Accurate estimation of standard deviations for quantitative methods used in clinical chemistry
-
Burnett RW: Accurate estimation of standard deviations for quantitative methods used in clinical chemistry. Clin Chem 1975;21:1935-1938.
-
(1975)
Clin Chem
, vol.21
, pp. 1935-1938
-
-
Burnett, R.W.1
-
21
-
-
70350780199
-
Interference studies with two hospital-grade and two home-grade glucose meters
-
Lyon ME, Baskin LB, Braakman S, Presti S, Dubois J, Shirey T: Interference studies with two hospital-grade and two home-grade glucose meters. Diabetes Technol Ther 2009; 11:641-647.
-
(2009)
Diabetes Technol Ther
, vol.11
, pp. 641-647
-
-
Lyon, M.E.1
Baskin, L.B.2
Braakman, S.3
Presti, S.4
Dubois, J.5
Shirey, T.6
-
23
-
-
0023205574
-
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
-
Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL: Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 1987;10:622-628. (Pubitemid 17158937)
-
(1987)
Diabetes Care
, vol.10
, Issue.5
, pp. 622-628
-
-
Clarke, W.L.1
Cox, D.2
Gonder-Frederick, L.A.3
Carter, W.4
Pohl, S.L.5
|