-
1
-
-
67349210358
-
Postoperative monitoring of microsurgical free tissue transfers for head and neck reconstruction: A systematic review of current techniquespart I. Non-invasive techniques
-
Abdel-Galil K, Mitchell D. Postoperative monitoring of microsurgical free tissue transfers for head and neck reconstruction: a systematic review of current techniquespart I. Non-invasive techniques. Br J Oral Maxillofac Surg 2009 47 5 351-355
-
(2009)
Br J Oral Maxillofac Surg
, vol.47
, Issue.5
, pp. 351-355
-
-
Abdel-Galil, K.1
Mitchell, D.2
-
2
-
-
57249092690
-
Monitoring for upper-extremity free flaps and replantations
-
Bakri K, Moran S L. Monitoring for upper-extremity free flaps and replantations. J Hand Surg Am 2008 33 10 1905-1908
-
(2008)
J Hand Surg Am
, vol.33
, Issue.10
, pp. 1905-1908
-
-
Bakri, K.1
Moran, S.L.2
-
3
-
-
34250753273
-
Timing of presentation of the first signs of vascular compromise dictates the salvage outcome of free flap transfers
-
DOI 10.1097/01.prs.0000264077.07779.50, PII 0000653420070700000025
-
Chen K T., Mardini S, Chuang D C. et al. Timing of presentation of the first signs of vascular compromise dictates the salvage outcome of free flap transfers. Plast Reconstr Surg 2007 120 1 187-195 (Pubitemid 46956049)
-
(2007)
Plastic and Reconstructive Surgery
, vol.120
, Issue.1
, pp. 187-195
-
-
Chen, K.-T.1
Mardini, S.2
Chuang, D.C.-C.3
Lin, C.-H.4
Cheng, M.-H.5
Lin, Y.-T.6
Huang, W.-C.7
Tsao, C.-K.8
Wei, F.-C.9
-
4
-
-
0032978923
-
Efficacy of conventional monitoring techniques in free tissue transfer: An 11-year experience in 750 consecutive cases
-
DOI 10.1097/00006534-199907000-00013
-
Disa J J., Cordeiro P G., Hidalgo D A. Efficacy of conventional monitoring techniques in free tissue transfer: an 11-year experience in 750 consecutive cases. Plast Reconstr Surg 1999 104 1 97-101 (Pubitemid 29283196)
-
(1999)
Plastic and Reconstructive Surgery
, vol.104
, Issue.1
, pp. 97-101
-
-
Disa, J.J.1
Cordeiro, P.G.2
Hidalgo, D.A.3
-
5
-
-
77955545865
-
More consistent postoperative care and monitoring can reduce costs following microvascular free flap reconstruction
-
Haddock N T., Gobble R M., Levine J P. More consistent postoperative care and monitoring can reduce costs following microvascular free flap reconstruction. J Reconstr Microsurg 2010 26 7 435-439
-
(2010)
J Reconstr Microsurg
, vol.26
, Issue.7
, pp. 435-439
-
-
Haddock, N.T.1
Gobble, R.M.2
Levine, J.P.3
-
6
-
-
26844442293
-
Postoperative monitoring of free flaps in UK plastic surgery units
-
DOI 10.1002/micr.20148
-
Jallali N, Ridha H, Butler P E. Postoperative monitoring of free flaps in UK plastic surgery units. Microsurgery 2005 25 6 469-472 (Pubitemid 41446770)
-
(2005)
Microsurgery
, vol.25
, Issue.6
, pp. 469-472
-
-
Jallali, N.1
Ridha, H.2
Butler, P.E.3
-
7
-
-
75149143627
-
Advancements in free flap monitoring in the last decade: A critical review
-
Smit J M., Zeebregts C J., Acosta R, Werker P M. Advancements in free flap monitoring in the last decade: a critical review. Plast Reconstr Surg 2010 125 1 177-185
-
(2010)
Plast Reconstr Surg
, vol.125
, Issue.1
, pp. 177-185
-
-
Smit, J.M.1
Zeebregts, C.J.2
Acosta, R.3
Werker, P.M.4
-
8
-
-
0036784543
-
Monitoring flap for buried free tissue transfer: Its importance and reliability
-
Cho B C., Shin D P., Byun J S., Park J W., Baik B S. Monitoring flap for buried free tissue transfer: its importance and reliability. Plast Reconstr Surg 2002 110 5 1249-1258
-
(2002)
Plast Reconstr Surg
, vol.110
, Issue.5
, pp. 1249-1258
-
-
Cho, B.C.1
Shin, D.P.2
Byun, J.S.3
Park, J.W.4
Baik, B.S.5
-
9
-
-
47949103170
-
The implantable Cook-Swartz Doppler probe for postoperative monitoring in head and neck free flap reconstruction
-
Guillemaud J P., Seikaly H, Cote D, Allen H, Harris J R. The implantable Cook-Swartz Doppler probe for postoperative monitoring in head and neck free flap reconstruction. Arch Otolaryngol Head Neck Surg 2008 134 7 729-734
-
(2008)
Arch Otolaryngol Head Neck Surg
, vol.134
, Issue.7
, pp. 729-734
-
-
Guillemaud, J.P.1
Seikaly, H.2
Cote, D.3
Allen, H.4
Harris, J.R.5
-
10
-
-
33746824687
-
Monitoring buried free flaps: Limitations of the implantable Doppler and use of color duplex sonography as a confirmatory test
-
DOI 10.1097/01.prs.0000221113.78244.8c, PII 0000653420060700000016
-
Rosenberg J J., Fornage B D., Chevray P M. Monitoring buried free flaps: limitations of the implantable Doppler and use of color duplex sonography as a confirmatory test. Plast Reconstr Surg 2006 118 1 109-113, discussion 114115 (Pubitemid 44324173)
-
(2006)
Plastic and Reconstructive Surgery
, vol.118
, Issue.1
, pp. 109-113
-
-
Rosenberg, J.J.1
Fornage, B.D.2
Chevray, P.M.3
-
11
-
-
76549104333
-
The efficacy of postoperative monitoring: A single surgeon comparison of clinical monitoring and the implantable Doppler probe in 547 consecutive free flaps
-
Rozen W M., Chubb D, Whitaker I S., Acosta R. The efficacy of postoperative monitoring: a single surgeon comparison of clinical monitoring and the implantable Doppler probe in 547 consecutive free flaps. Microsurgery 2010 30 2 105-110
-
(2010)
Microsurgery
, vol.30
, Issue.2
, pp. 105-110
-
-
Rozen, W.M.1
Chubb, D.2
Whitaker, I.S.3
Acosta, R.4
-
12
-
-
70149124549
-
Post operative monitoring of microvascular breast reconstructions using the implantable Cook-Swartz doppler system: A study of 145 probes & technical discussion
-
Smit J M., Whitaker I S., Liss A G., Audolfsson T, Kildal M, Acosta R. Post operative monitoring of microvascular breast reconstructions using the implantable Cook-Swartz doppler system: a study of 145 probes & technical discussion. J Plast Reconstr Aesthet Surg 2009 62 10 1286-1292
-
(2009)
J Plast Reconstr Aesthet Surg
, vol.62
, Issue.10
, pp. 1286-1292
-
-
Smit, J.M.1
Whitaker, I.S.2
Liss, A.G.3
Audolfsson, T.4
Kildal, M.5
Acosta, R.6
-
13
-
-
78650983191
-
Eight-year experience of the Cook-Swartz Doppler in free-flap operations: Microsurgical and reexploration results with regard to a wide spectrum of surgeries
-
Schmulder A, Gur E, Zaretski A. Eight-year experience of the Cook-Swartz Doppler in free-flap operations: microsurgical and reexploration results with regard to a wide spectrum of surgeries. Microsurgery 2011 31 1 1-6
-
(2011)
Microsurgery
, vol.31
, Issue.1
, pp. 1-6
-
-
Schmulder, A.1
Gur, E.2
Zaretski, A.3
-
14
-
-
32944466233
-
Design of a visible-light spectroscopy clinical tissue oximeter
-
Benaron D A., Parachikov I H., Cheong W F. et al. Design of a visible-light spectroscopy clinical tissue oximeter. J Biomed Opt 2005 10 4 44005
-
(2005)
J Biomed Opt
, vol.10
, Issue.4
, pp. 44005
-
-
Benaron, D.A.1
Parachikov, I.H.2
Cheong, W.F.3
-
15
-
-
68349160524
-
Postoperative monitoring of microsurgical free-tissue transfers for head and neck reconstruction: A systematic review of current techniquespart II. Invasive techniques
-
Abdel-Galil K, Mitchell D. Postoperative monitoring of microsurgical free-tissue transfers for head and neck reconstruction: a systematic review of current techniquespart II. Invasive techniques. Br J Oral Maxillofac Surg 2009 47 6 438-442
-
(2009)
Br J Oral Maxillofac Surg
, vol.47
, Issue.6
, pp. 438-442
-
-
Abdel-Galil, K.1
Mitchell, D.2
-
16
-
-
34249932327
-
Non-invasive tissue oximetry for flap monitoring: An initial study
-
DOI 10.1055/s-2007-974655
-
Keller A. Noninvasive tissue oximetry for flap monitoring: an initial study. J Reconstr Microsurg 2007 23 4 189-197 (Pubitemid 46878832)
-
(2007)
Journal of Reconstructive Microsurgery
, vol.23
, Issue.4
, pp. 189-197
-
-
Keller, A.1
-
17
-
-
68949176891
-
Advances in free flap monitoring: Have we gone too far
-
Luu Q, Farwell D G. Advances in free flap monitoring: have we gone too far? Curr Opin Otolaryngol Head Neck Surg 2009 17 4 267-269
-
(2009)
Curr Opin Otolaryngol Head Neck Surg
, vol.17
, Issue.4
, pp. 267-269
-
-
Luu, Q.1
Farwell, D.G.2
-
18
-
-
2542450814
-
Continuous, noninvasive, and localized microvascular tissue oximetry using visible light spectroscopy
-
DOI 10.1097/00000542-200406000-00019
-
Benaron D A., Parachikov I H., Friedland S et al. Continuous, noninvasive, and localized microvascular tissue oximetry using visible light spectroscopy. Anesthesiology 2004 100 6 1469-1475 (Pubitemid 38679316)
-
(2004)
Anesthesiology
, vol.100
, Issue.6
, pp. 1469-1475
-
-
Benaron, D.A.1
Parachikov, I.H.2
Friedland, S.3
Soetikno, R.4
Brock-Utne, J.5
Van Der Starre, P.J.A.6
Nezhat, C.7
Terris, M.K.8
Maxim, P.G.9
Carson, J.J.L.10
Razavi, M.K.11
Gladstone, H.B.12
Fincher, E.F.13
Hsu, C.P.14
Clark, F.L.15
Cheong, W.-F.16
Duckworth, J.L.17
Stevenson, D.K.18
-
19
-
-
79957845335
-
Intraoperative assessment of microperfusion with visible light spectroscopy for prediction of anastomotic leakage in colorectal anastomoses
-
Karliczek A, Benaron D A., Baas P C., Zeebregts C J., Wiggers T, van Dam G M. Intraoperative assessment of microperfusion with visible light spectroscopy for prediction of anastomotic leakage in colorectal anastomoses. Colorectal Dis 2010 12 10 1018-1025
-
(2010)
Colorectal Dis
, vol.12
, Issue.10
, pp. 1018-1025
-
-
Karliczek, A.1
Benaron, D.A.2
Baas, P.C.3
Zeebregts, C.J.4
Wiggers, T.5
Van Dam, G.M.6
-
20
-
-
63849333399
-
In vivo detection of myocardial ischemia in pigs using visible light spectroscopy
-
Ho J K., Liakopoulos O J., Crowley R et al. In vivo detection of myocardial ischemia in pigs using visible light spectroscopy. Anesth Analg 2009 108 4 1185-1192
-
(2009)
Anesth Analg
, vol.108
, Issue.4
, pp. 1185-1192
-
-
Ho, J.K.1
Liakopoulos, O.J.2
Crowley, R.3
-
21
-
-
38949168887
-
Evaluation of near infrared spectroscopy in monitoring postoperative regional tissue oxygen saturation for fibular flaps
-
DOI 10.1016/j.bjps.2007.10.047, PII S1748681507005645
-
Cai Z G., Zhang J, Zhang J G. et al. Evaluation of near infrared spectroscopy in monitoring postoperative regional tissue oxygen saturation for fibular flaps. J Plast Reconstr Aesthet Surg 2008 61 3 289-296 (Pubitemid 351215146)
-
(2008)
Journal of Plastic, Reconstructive and Aesthetic Surgery
, vol.61
, Issue.3
, pp. 289-296
-
-
Cai, Z.-g.1
Zhang, J.2
Zhang, J.-g.3
Zhao, F.-y.4
Yu, G.-y.5
Li, Y.6
Ding, H.-s.7
-
22
-
-
43149111830
-
Near-infrared spectroscopy measures tissue oxygenation in free flaps for breast reconstruction
-
DOI 10.1097/PRS.0b013e31816b11e5, PII 0000653420080500000088
-
Colwell A S., Wright L, Karanas Y. Near-infrared spectroscopy measures tissue oxygenation in free flaps for breast reconstruction. Plast Reconstr Surg 2008 121 5 344e-345e (Pubitemid 351642784)
-
(2008)
Plastic and Reconstructive Surgery
, vol.121
, Issue.5
-
-
Colwell, A.S.1
Wright, L.2
Karanas, Y.3
-
23
-
-
36649008539
-
Continuous postoperative monitoring of cutaneous free flaps using near infrared spectroscopy
-
DOI 10.1016/j.bjps.2007.04.003, PII S1748681507002471
-
Repez A, Oroszy D, Arnez Z M. Continuous postoperative monitoring of cutaneous free flaps using near infrared spectroscopy. J Plast Reconstr Aesthet Surg 2008 61 1 71-77 (Pubitemid 350199113)
-
(2008)
Journal of Plastic, Reconstructive and Aesthetic Surgery
, vol.61
, Issue.1
, pp. 71-77
-
-
Repez, A.1
Oroszy, D.2
Arnez, Z.M.3
-
24
-
-
84860213961
-
-
Available at
-
Spectros. Available at: http://www.spectros.com Accessed August 9, 2010
-
(2010)
Spectros
-
-
-
25
-
-
47349104134
-
Monitoring microvascular free flaps with tissue oxygen measurement and PET
-
Schrey A R., Kinnunen I A., Grénman R A., Minn H R., Aitasalo K M. Monitoring microvascular free flaps with tissue oxygen measurement and PET. Eur Arch Otorhinolaryngol 2008 265 Suppl 1 S105-S113
-
(2008)
Eur Arch Otorhinolaryngol
, vol.265
, Issue.SUPPL. 1
-
-
Schrey, A.R.1
Kinnunen, I.A.2
Grénman, R.A.3
Minn, H.R.4
Aitasalo, K.M.5
-
26
-
-
77951081726
-
Monitoring of free flaps using near-infrared spectroscopy: A systematic review of the initial trials
-
Najefi A, Leff D R., Nicolaou M, Nduka C, Yang G Z., Darzi A W. Monitoring of free flaps using near-infrared spectroscopy: a systematic review of the initial trials. Plast Reconstr Surg 2010 125 4 182e-184e
-
(2010)
Plast Reconstr Surg
, vol.125
, Issue.4
-
-
Najefi, A.1
Leff, D.R.2
Nicolaou, M.3
Nduka, C.4
Yang, G.Z.5
Darzi, A.W.6
-
27
-
-
0028140059
-
Implantable venous doppler microvascular monitoring: Laboratory investigation and clinical results
-
Swartz W M., Izquierdo R, Miller M J. Implantable venous Doppler microvascular monitoring: laboratory investigation and clinical results. Plast Reconstr Surg 1994 93 1 152-163 (Pubitemid 24015175)
-
(1994)
Plastic and Reconstructive Surgery
, vol.93
, Issue.1
, pp. 152-163
-
-
Swartz, W.M.1
Izquierdo, R.2
Miller, M.J.3
|