메뉴 건너뛰기




Volumn 47, Issue 6, 2009, Pages 438-442

Postoperative monitoring of microsurgical free-tissue transfers for head and neck reconstruction: a systematic review of current techniques-Part II. Invasive techniques

Author keywords

Free tissue transfer; Monitoring techniques; Systematic review

Indexed keywords

ARTICLE; COLOR ULTRASOUND FLOWMETRY; CONTRAST ENHANCEMENT; DIAGNOSTIC IMAGING; FREE TISSUE GRAFT; HEAD AND NECK SURGERY; HUMAN; IMPLANT; INVASIVE PROCEDURE; LASER DOPPLER FLOWMETRY; MICRODIALYSIS; MICROSURGERY; OXYGEN TENSION; OXYGEN TISSUE LEVEL; PATIENT MONITORING; PH MEASUREMENT; POSTOPERATIVE CARE; SALVAGE THERAPY; SURGICAL TECHNIQUE; SYSTEMATIC REVIEW; TEMPERATURE MEASUREMENT;

EID: 68349160524     PISSN: 02664356     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bjoms.2008.12.002     Document Type: Article
Times cited : (69)

References (32)
  • 3
    • 0031718428 scopus 로고    scopus 로고
    • A review of 716 consecutive free flaps for oncologic surgical defects: refinement in donor-site selection and technique
    • Hidalgo D.A., Disa J.J., Cordeiro P.G., and Hu Q.-Y. A review of 716 consecutive free flaps for oncologic surgical defects: refinement in donor-site selection and technique. Plast Reconstr Surg 102 (1998) 722-732
    • (1998) Plast Reconstr Surg , vol.102 , pp. 722-732
    • Hidalgo, D.A.1    Disa, J.J.2    Cordeiro, P.G.3    Hu, Q.-Y.4
  • 4
    • 0018146044 scopus 로고
    • How soon may the axial vessels of a surviving free flap be safely ligated: a study in pigs
    • Black M.J., Chait L., O'Brien B.M., Sykes P.J., and Sharzer L.A. How soon may the axial vessels of a surviving free flap be safely ligated: a study in pigs. Br J Plast Surg 31 (1978) 295-299
    • (1978) Br J Plast Surg , vol.31 , pp. 295-299
    • Black, M.J.1    Chait, L.2    O'Brien, B.M.3    Sykes, P.J.4    Sharzer, L.A.5
  • 6
    • 0023835477 scopus 로고
    • Direct monitoring of microvascular anastomoses with the 20 MHz ultrasonic Doppler probe: an experimental and clinical study
    • Swartz W.M., Jones N.F., Cherup L.L., and Klein A. Direct monitoring of microvascular anastomoses with the 20 MHz ultrasonic Doppler probe: an experimental and clinical study. Plast Reconstr Surg 81 (1988) 149-161
    • (1988) Plast Reconstr Surg , vol.81 , pp. 149-161
    • Swartz, W.M.1    Jones, N.F.2    Cherup, L.L.3    Klein, A.4
  • 7
    • 0028140059 scopus 로고
    • Implantable venous Doppler microvascular monitoring: laboratory investigation and clinical results
    • Swartz W.M., Izquierdo R., and Miller M.J. Implantable venous Doppler microvascular monitoring: laboratory investigation and clinical results. Plast Reconstr Surg 93 (1994) 152-163
    • (1994) Plast Reconstr Surg , vol.93 , pp. 152-163
    • Swartz, W.M.1    Izquierdo, R.2    Miller, M.J.3
  • 8
    • 0043234159 scopus 로고    scopus 로고
    • Retrospective review of the internal Doppler probe for intra- and postoperative microvascular surveillance
    • De la Torre J., Hedden W., Grant III J.H., Gardner P.M., Fix R.J., and Vasconez L.O. Retrospective review of the internal Doppler probe for intra- and postoperative microvascular surveillance. J Reconstr Microsurg 19 (2003) 287-290
    • (2003) J Reconstr Microsurg , vol.19 , pp. 287-290
    • De la Torre, J.1    Hedden, W.2    Grant III, J.H.3    Gardner, P.M.4    Fix, R.J.5    Vasconez, L.O.6
  • 9
    • 51349131623 scopus 로고    scopus 로고
    • Pr44p Monitoring buried free flaps-New Zealand's first four clinical cases of free flap monitoring with implantable 20 MHz ultrasonic Doppler probe
    • Mistry Y., James D.W., and Sinclair S. Pr44p Monitoring buried free flaps-New Zealand's first four clinical cases of free flap monitoring with implantable 20 MHz ultrasonic Doppler probe. ANZ J Surg 77 Suppl 1 (2007) A70
    • (2007) ANZ J Surg , vol.77 , Issue.SUPPL. 1
    • Mistry, Y.1    James, D.W.2    Sinclair, S.3
  • 10
    • 14944344874 scopus 로고    scopus 로고
    • The Cook-Swartz venous doppler probe for the post-operative monitoring of free tissue transfers in the United Kingdom: a preliminary report
    • Oliver D.W., Whitaker I.S., Giele H., Critchley P., and Cassell O. The Cook-Swartz venous doppler probe for the post-operative monitoring of free tissue transfers in the United Kingdom: a preliminary report. Br J Plast Surg 58 (2005) 366-370
    • (2005) Br J Plast Surg , vol.58 , pp. 366-370
    • Oliver, D.W.1    Whitaker, I.S.2    Giele, H.3    Critchley, P.4    Cassell, O.5
  • 11
    • 0028730292 scopus 로고
    • Nonlinear acoustical response of coated microbubbles in diagnostic ultrasound
    • Uhlendorf V., and Hoffman C. Nonlinear acoustical response of coated microbubbles in diagnostic ultrasound. Proc IEEE Ultrason Symp (1994) 1559-1564
    • (1994) Proc IEEE Ultrason Symp , pp. 1559-1564
    • Uhlendorf, V.1    Hoffman, C.2
  • 12
    • 0031363435 scopus 로고    scopus 로고
    • Pulse inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents
    • Simpson D.H., and Burns P.N. Pulse inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents. Proc IEEE Ultrason Symp (1997) 1597-1600
    • (1997) Proc IEEE Ultrason Symp , pp. 1597-1600
    • Simpson, D.H.1    Burns, P.N.2
  • 13
    • 0036835868 scopus 로고    scopus 로고
    • Contrast echocardiography
    • Lindner J.R., and Wei K. Contrast echocardiography. Curr Probl Cardiol 27 (2002) 454-519
    • (2002) Curr Probl Cardiol , vol.27 , pp. 454-519
    • Lindner, J.R.1    Wei, K.2
  • 14
    • 0034067847 scopus 로고    scopus 로고
    • Harmonic hepatic US with microbubble contrast agent: initial experience showing improved characterization of hemangioma, hepatocellular carcinoma, and metastasis
    • Wilson S.R., Burns P.N., Muradali D., Wilson J.A., and Lai X. Harmonic hepatic US with microbubble contrast agent: initial experience showing improved characterization of hemangioma, hepatocellular carcinoma, and metastasis. Radiology 215 (2000) 153-161
    • (2000) Radiology , vol.215 , pp. 153-161
    • Wilson, S.R.1    Burns, P.N.2    Muradali, D.3    Wilson, J.A.4    Lai, X.5
  • 15
    • 0035869313 scopus 로고    scopus 로고
    • Quantification of renal blood flow with contrast-enhanced ultrasound
    • Wei K., Le E., Bin J.P., Coggins M., Thorpe J., and Kaul S. Quantification of renal blood flow with contrast-enhanced ultrasound. J Am Coll Cardiol 37 (2001) 1135-1140
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1135-1140
    • Wei, K.1    Le, E.2    Bin, J.P.3    Coggins, M.4    Thorpe, J.5    Kaul, S.6
  • 16
    • 0035923637 scopus 로고    scopus 로고
    • Quantification of cerebral perfusion with "real-time" contrast-enhanced ultrasound
    • Rim S.J., Leong-Poi H., Lindner J.R., Couture D., Ellegala D., Mason H., et al. Quantification of cerebral perfusion with "real-time" contrast-enhanced ultrasound. Circulation 104 (2001) 2582-2587
    • (2001) Circulation , vol.104 , pp. 2582-2587
    • Rim, S.J.1    Leong-Poi, H.2    Lindner, J.R.3    Couture, D.4    Ellegala, D.5    Mason, H.6
  • 17
    • 0036087465 scopus 로고    scopus 로고
    • Vascular recruitment in skeletal muscle during exercise and hyperinsulinemia assessed by contrast ultrasound
    • Dawson D., Vincent M.A., Barrett E.J., Kaul S., Clark A., Leong-Poi H., et al. Vascular recruitment in skeletal muscle during exercise and hyperinsulinemia assessed by contrast ultrasound. Am J Physiol Endocrinol Metab 282 (2002) E714-E720
    • (2002) Am J Physiol Endocrinol Metab , vol.282
    • Dawson, D.1    Vincent, M.A.2    Barrett, E.J.3    Kaul, S.4    Clark, A.5    Leong-Poi, H.6
  • 18
    • 0020513410 scopus 로고
    • Removable thermocouple probe microvascular patency monitor: an experimental and clinical study
    • May J.W., Lukash F.N., Gallico G.G., and Stirrat C.R. Removable thermocouple probe microvascular patency monitor: an experimental and clinical study. Plast Reconstr Surg 72 (1983) 366-379
    • (1983) Plast Reconstr Surg , vol.72 , pp. 366-379
    • May, J.W.1    Lukash, F.N.2    Gallico, G.G.3    Stirrat, C.R.4
  • 19
    • 0021950960 scopus 로고
    • Thermocouple probe monitoring for free tissue transfer, replantation and revascularization procedures
    • May J.W., and Halls M.J. Thermocouple probe monitoring for free tissue transfer, replantation and revascularization procedures. Clin Plast Surg 12 (1985) 197-207
    • (1985) Clin Plast Surg , vol.12 , pp. 197-207
    • May, J.W.1    Halls, M.J.2
  • 21
    • 0019733001 scopus 로고
    • 2 monitoring for assessing viability and predicting survival of skin flaps: experimental and clinical correlations
    • 2 monitoring for assessing viability and predicting survival of skin flaps: experimental and clinical correlations. J Microsurg 2 (1981) 165-178
    • (1981) J Microsurg , vol.2 , pp. 165-178
    • Serafin, D.1    Lesesne, C.B.2    Mullen, R.Y.3    Georgiade, N.G.4
  • 22
    • 0020964992 scopus 로고
    • Clinical application of transcutaneous oxygen measurements in replantation surgery and free tissue transfer
    • Smith A.R., Sonneveld G.J., Kort W.J., and Van der Meulen J.C. Clinical application of transcutaneous oxygen measurements in replantation surgery and free tissue transfer. J Hand Surg 8 (1983) 139-145
    • (1983) J Hand Surg , vol.8 , pp. 139-145
    • Smith, A.R.1    Sonneveld, G.J.2    Kort, W.J.3    Van der Meulen, J.C.4
  • 23
  • 24
    • 0023841211 scopus 로고    scopus 로고
    • 2: a new technique for monitoring flap viability
    • 2: a new technique for monitoring flap viability. Ann Plast Surg 20 (1996) 43-47
    • (1996) Ann Plast Surg , vol.20 , pp. 43-47
    • Mahoney, J.L.1    Lista, F.R.2
  • 26
    • 0020842714 scopus 로고
    • Tissue pH monitoring in microsurgery: a preliminary evaluation of continuous tissue pH monitoring as an indicator of perfusion disturbances in microvascular free flaps
    • Raskin D.J., Erk Y., Spira M., and Melissinos E.G. Tissue pH monitoring in microsurgery: a preliminary evaluation of continuous tissue pH monitoring as an indicator of perfusion disturbances in microvascular free flaps. Ann Plast Surg 11 (1983) 331-339
    • (1983) Ann Plast Surg , vol.11 , pp. 331-339
    • Raskin, D.J.1    Erk, Y.2    Spira, M.3    Melissinos, E.G.4
  • 27
    • 0024536594 scopus 로고
    • Comparative response of muscle and subcutaneous tissue pH during arterial and venous occlusion in musculocutaneous flaps
    • Warner K.G., Durham-Smith G., Butler M.D., Attinger C.E., Upton J., and Khuri S.F. Comparative response of muscle and subcutaneous tissue pH during arterial and venous occlusion in musculocutaneous flaps. Ann Plast Surg 22 (1989) 108-116
    • (1989) Ann Plast Surg , vol.22 , pp. 108-116
    • Warner, K.G.1    Durham-Smith, G.2    Butler, M.D.3    Attinger, C.E.4    Upton, J.5    Khuri, S.F.6
  • 31
    • 0036165385 scopus 로고    scopus 로고
    • Metabolism in pedicled and free TRAM flaps: a comparison using the microdialysis technique
    • Edsander-Nord A., Rojdmark J., and Wickman M. Metabolism in pedicled and free TRAM flaps: a comparison using the microdialysis technique. Plast Reconstr Surg 109 (2002) 664-673
    • (2002) Plast Reconstr Surg , vol.109 , pp. 664-673
    • Edsander-Nord, A.1    Rojdmark, J.2    Wickman, M.3
  • 32
    • 2642547407 scopus 로고    scopus 로고
    • Glucose, lactate, and pyruvate reponse in an experimental model of microvascular flap ischemia and reperfusion: a microdialysis study
    • Setala L.P., Korvenoja E.M., Harma M.A., Alhava E.M., Uusaro A.V., and Tenhunen J.J. Glucose, lactate, and pyruvate reponse in an experimental model of microvascular flap ischemia and reperfusion: a microdialysis study. Microsurgery 24 (2004) 223-231
    • (2004) Microsurgery , vol.24 , pp. 223-231
    • Setala, L.P.1    Korvenoja, E.M.2    Harma, M.A.3    Alhava, E.M.4    Uusaro, A.V.5    Tenhunen, J.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.