메뉴 건너뛰기




Volumn 26, Issue 9, 2011, Pages 2194-2203

Simultaneous screening for osteoporosis at CT colonography: Bone mineral density assessment using MDCT attenuation techniques compared with the DXA reference standard

Author keywords

BONE MINERAL DENSITY; COMPUTED TOMOGRAPHY; CT COLONOGRAPHY; OSTEOPOROSIS; SCREENING

Indexed keywords

ADULT; AGED; ARTICLE; BONE DENSITY; COMPUTED TOMOGRAPHIC COLONOGRAPHY; DUAL ENERGY X RAY ABSORPTIOMETRY; FEMALE; HUMAN; LUMBAR SPINE; MAJOR CLINICAL STUDY; MALE; OSTEOPENIA; OSTEOPOROSIS; SCREENING TEST;

EID: 80051963642     PISSN: 08840431     EISSN: 15234681     Source Type: Journal    
DOI: 10.1002/jbmr.428     Document Type: Article
Times cited : (241)

References (34)
  • 1
    • 4143135208 scopus 로고    scopus 로고
    • Nonadenomatous polyps at CT colonography: Prevalence, size distribution, and detection rates
    • DOI 10.1148/radiol.2323031614
    • Pickhardt PJ, Choi JR, Hwang I, Schindler WR,. Nonadenomatous polyps at CT colonography: prevalence, size distribution, and detection rates. Radiology. 2004; 232: 784-790. (Pubitemid 39100264)
    • (2004) Radiology , vol.232 , Issue.3 , pp. 784-790
    • Pickhardt, P.J.1    Choi, J.R.2    Hwang, I.3    Schindler, W.R.4
  • 2
    • 57049178940 scopus 로고    scopus 로고
    • International Society for Clinical Densitometry 2007 adult and pediatric official positions
    • Lewiecki EM, Gordon CM, Baim S, et al. International Society for Clinical Densitometry 2007 adult and pediatric official positions. Bone. 2008; 43: 1115-1121.
    • (2008) Bone. , vol.43 , pp. 1115-1121
    • Lewiecki, E.M.1    Gordon, C.M.2    Baim, S.3
  • 3
    • 80052014121 scopus 로고    scopus 로고
    • National Osteoporosis Foundation (accessed June 17, 2010, at)
    • National Osteoporosis Foundation (accessed June 17, 2010, at).
  • 4
    • 79953808423 scopus 로고    scopus 로고
    • Feasibility of simultaneous computed tomographic colonography and fully automated bone mineral densitometry in a single examination
    • Summers RM, Baecher N, Yao J, et al. Feasibility of simultaneous computed tomographic colonography and fully automated bone mineral densitometry in a single examination. J Comput Assist Tomogr. 2011; 35: 212-216.
    • (2011) J Comput Assist Tomogr. , vol.35 , pp. 212-216
    • Summers, R.M.1    Baecher, N.2    Yao, J.3
  • 6
    • 34547596744 scopus 로고    scopus 로고
    • Screening CT colonography: How I do it
    • DOI 10.2214/AJR.07.2136
    • Pickhardt PJ,. Screening CT colonography: how I do it. AJR Am J Roentgenol. 2007; 189: 290-298. (Pubitemid 47195912)
    • (2007) American Journal of Roentgenology , vol.189 , Issue.2 , pp. 290-298
    • Pickhardt, P.J.1
  • 8
    • 33645832185 scopus 로고    scopus 로고
    • Extracolonic findings identified in asymptomatic adults at screening CT colonography
    • DOI 10.2214/AJR.04.1748
    • Pickhardt PJ, Taylor AJ,. Extracolonic findings identified in asymptomatic adults at screening CT colonography. Am J Roentgenol. 2006; 186: 718-728. (Pubitemid 46100256)
    • (2006) American Journal of Roentgenology , vol.186 , Issue.3 , pp. 718-728
    • Pickhardt, P.J.1    Taylor, A.J.2
  • 10
    • 69849098328 scopus 로고    scopus 로고
    • Quantitative computed tomography
    • Adams JE,. Quantitative computed tomography. Eur J Radiol. 2009; 71: 415-424.
    • (2009) Eur J Radiol. , vol.71 , pp. 415-424
    • Adams, J.E.1
  • 12
    • 22044443714 scopus 로고    scopus 로고
    • Screening for osteoporosis
    • DOI 10.1056/NEJMcp042092
    • Raisz LG,. Screening for osteoporosis. N Engl J Med. 2005; 353: 164-171. (Pubitemid 41058348)
    • (2005) New England Journal of Medicine , vol.353 , Issue.2 , pp. 164-171
    • Raisz, L.G.1
  • 13
    • 2442652872 scopus 로고    scopus 로고
    • In vitro and in vivo spiral CT to determine bone mineral density: Initial experience in patients at risk for osteoporosis
    • DOI 10.1148/radiol.2313030325
    • Link TM, Koppers BB, Licht T, Bauer J, Lu Y, Rummeny EJ,. In vitro and in vivo spiral CT to determine bone mineral density: Initial experience in patients at risk for osteoporosis. Radiology. 2004; 231: 805-811. (Pubitemid 38668102)
    • (2004) Radiology , vol.231 , Issue.3 , pp. 805-811
    • Link, T.M.1    Koppers, B.B.2    Licht, T.3    Bauer, J.4    Lu, Y.5    Rummeny, E.J.6
  • 16
    • 77955290049 scopus 로고    scopus 로고
    • Screening for Osteoporosis: An Update for the US Preventive Services Task Force
    • Nelson HD, Haney EM, Dana T, Bougatsos C, Chou R,. Screening for Osteoporosis: An Update for the US Preventive Services Task Force. Ann Intern Med. 2010; 153: 99-W43.
    • (2010) Ann Intern Med. , vol.153
    • Nelson, H.D.1    Haney, E.M.2    Dana, T.3    Bougatsos, C.4    Chou, R.5
  • 17
    • 0028790121 scopus 로고
    • Quantitative computed tomography (QCT) and dual x-ray absorptiometry (DXA) in the diagnosis of osteoporosis
    • Guglielmi G,. Quantitative computed tomography (QCT) and dual x-ray absorptiometry (DXA) in the diagnosis of osteoporosis. Eur J Radiol. 1995; 20: 185-17.
    • (1995) Eur J Radiol. , vol.20 , pp. 185-117
    • Guglielmi, G.1
  • 18
    • 0028049747 scopus 로고
    • Osteoporosis: Diagnosis with lateral and posteroanterior dual x-ray absorptiometry compared with quantitative CT
    • Guglielmi G, Grimston SK, Fischer KC, Pacifici R,. Osteoporosis-diagnosis with lateral and posteroanterior dual x-ray absorptiometry compared with quantitative C. Radiology. 1994; 192: 845-850. (Pubitemid 24266808)
    • (1994) Radiology , vol.192 , Issue.3 , pp. 845-850
    • Guglielmi, G.1    Grimston, S.K.2    Fischer, K.C.3    Pacifici, R.4
  • 20
    • 0036096033 scopus 로고    scopus 로고
    • Quantitative computed tomography of the lumbar spine, not dual x-ray absorptiometry, is an independent predictor of prevalent vertebral fractures in postmenopausal women with osteopenia receiving long-term glucocorticoid and hormone-replacement therapy
    • DOI 10.1002/art.10277
    • Rehman Q, Lang T, Modin G, Lane NE,. Quantitative computed tomography of the lumbar spine, not dual X-ray absorptiometry, is an independent predictor of prevalent vertebral fractures in postmenopausal women with osteopenia receiving long-term glucocorticoid and hormone-replacement therapy. Arthritis Rheum. 2002; 46: 1292-1297. (Pubitemid 34525838)
    • (2002) Arthritis and Rheumatism , vol.46 , Issue.5 , pp. 1292-1297
    • Rehman, Q.1    Lang, T.2    Modin, G.3    Lane, N.E.4
  • 21
    • 0031265048 scopus 로고    scopus 로고
    • QCT, the most accurate method of measuring bone mineral density?
    • Weigert JM,. QCT, the most accurate method of measuring bone mineral density? J Bone Miner Res. 1997; 12: 1954-1955.
    • (1997) J Bone Miner Res. , vol.12 , pp. 1954-1955
    • Weigert, J.M.1
  • 22
    • 0029033292 scopus 로고
    • Influence of degenerative joint disease on spinal bone mineral measurements in postmenopausal women
    • Yu W, Gluer CC, Fuerst T, et al. Influence of degenerative joint disease on spinal bone mineral measurements in postmenopausal women. Calcif Tissue Int. 1995; 57: 169-174.
    • (1995) Calcif Tissue Int. , vol.57 , pp. 169-174
    • Yu, W.1    Gluer, C.C.2    Fuerst, T.3
  • 23
    • 0028895230 scopus 로고
    • Spinal bone mineral assessment in postmenopausal women: A comparison between dual X-ray absorptiometry and quantitative computed tomography
    • Yu W, Gluer CC, Grampp S, et al. Spinal bone mineral assessment in postmenopausal women: A comparison between dual X-ray absorptiometry and quantitative computed tomography. Osteoporosis Int. 1995; 5: 433-439.
    • (1995) Osteoporosis Int. , vol.5 , pp. 433-439
    • Yu, W.1    Gluer, C.C.2    Grampp, S.3
  • 24
    • 44349098538 scopus 로고    scopus 로고
    • IMV Des Plains, IL: IMV Medical Information Division; 2006
    • IMV. 2006. CT Market Summary Report. Des Plains, IL: IMV Medical Information Division; 2006.
    • (2006) CT Market Summary Report
  • 25
    • 0024613324 scopus 로고
    • Precise measurement of vertebral bone density using computed tomography without the use of an external reference phantom
    • Boden SD, Goodenough DJ, Stockham CD, Jacobs E, Dina T, Allman RM,. Precise measurement of vertebral bone density using computed tomography without the use of an external reference phantom. J Digit Imaging. 1989; 2: 31-38.
    • (1989) J Digit Imaging. , vol.2 , pp. 31-38
    • Boden, S.D.1    Goodenough, D.J.2    Stockham, C.D.3    Jacobs, E.4    Dina, T.5    Allman, R.M.6
  • 27
  • 28
    • 43049175471 scopus 로고    scopus 로고
    • FRAX (TM) and the assessment of fracture probability in men and women from the UK
    • Kanis JA, Johnell O, Oden A, Johansson H, McCloskey E,. FRAX (TM) and the assessment of fracture probability in men and women from the UK. Osteoporosis Int. 2008; 19: 385-397.
    • (2008) Osteoporosis Int. , vol.19 , pp. 385-397
    • Kanis, J.A.1    Johnell, O.2    Oden, A.3    Johansson, H.4    McCloskey, E.5
  • 29
    • 52249108133 scopus 로고    scopus 로고
    • Accuracy of CT colonography for detection of large adenomas and cancers
    • Johnson CD, Chen MH, Toledano AY, et al. Accuracy of CT colonography for detection of large adenomas and cancers. N Engl J Med. 2008; 359: 1207-1217.
    • (2008) N Engl J Med. , vol.359 , pp. 1207-1217
    • Johnson, C.D.1    Chen, M.H.2    Toledano, A.Y.3
  • 30
    • 53749086472 scopus 로고    scopus 로고
    • Unsuspected extracolonic findings at screening CT colonography: Clinical and economic impact
    • Pickhardt PJ, Hanson ME, Vanness DJ, et al. Unsuspected extracolonic findings at screening CT colonography: clinical and economic impact. Radiology. 2008; 249: 151-159.
    • (2008) Radiology. , vol.249 , pp. 151-159
    • Pickhardt, P.J.1    Hanson, M.E.2    Vanness, D.J.3
  • 31
    • 77950404461 scopus 로고    scopus 로고
    • Colorectal and extracolonic cancers detected at screening CT colonography in 10,286 asymptomatic adults
    • Pickhardt PJ, Kim DH, Meiners RJ, et al. Colorectal and extracolonic cancers detected at screening CT colonography in 10,286 asymptomatic adults. Radiology. 2010; 255: 83-88.
    • (2010) Radiology. , vol.255 , pp. 83-88
    • Pickhardt, P.J.1    Kim, D.H.2    Meiners, R.J.3
  • 32
    • 42449106833 scopus 로고    scopus 로고
    • Computed tomographic colonography to screen for colorectal cancer, extracolonic cancer, and aortic aneurysm: Model simulation with cost-effectiveness analysis
    • DOI 10.1001/archinte.168.7.696
    • Hassan C, Pickhardt P, Laghi A, et al. Computed tomographic colonography to screen for colorectal cancer, extracolonic cancer, and aortic aneurysm. Arch Intern Med. 2008; 168: 696-705. (Pubitemid 351563952)
    • (2008) Archives of Internal Medicine , vol.168 , Issue.7 , pp. 696-705
    • Hassan, C.1    Pickhardt, P.2    Laghi, A.3    Kim, D.4    Zullo, A.5    Iafrate, F.6    Di Giulio, L.7    Morini, S.8
  • 33
    • 29144471895 scopus 로고    scopus 로고
    • Sarcopenia in premenopausal and postmenopausal women with osteopenia, osteoporosis and normal bone mineral density
    • DOI 10.1007/s00198-005-1900-x
    • Walsh MC, Hunter GR, Livingstone MB,. Sarcopenia in premenopausal and postmenopausal women with osteopenia, osteoporosis and normal bone mineral density. Osteoporosis Int. 2006; 17: 61-67. (Pubitemid 41798029)
    • (2006) Osteoporosis International , vol.17 , Issue.1 , pp. 61-67
    • Walsh, M.C.1    Hunter, G.R.2    Livingstone, M.B.3
  • 34
    • 80051965888 scopus 로고    scopus 로고
    • Sarcopenia in ageing men with osteopenia, osteoporosis and normal bone mineral density
    • Zerbini CA, Pippa MG,. Sarcopenia in ageing men with osteopenia, osteoporosis and normal bone mineral density. J Bone Miner Res. 2007; 22: W264.
    • (2007) J Bone Miner Res. , vol.22
    • Zerbini, C.A.1    Pippa, M.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.