-
1
-
-
3442902210
-
LASIK for hyperopia, hyperopic astigmatism, and mixed astigmatism: A report by the American Academy of Ophthalmology
-
DOI 10.1016/j.ophtha.2004.05.016, PII S0161642004008176
-
G.A. Varley, D. Huang, C.J. Rapuano, S. Schallhorn, B.S. Boxer Wachler, and A. Sugar LASIK for hyperopia, hyperopic astigmatism, and mixed astigmatism; a report by the American Academy of Ophthalmology (Ophthalmic Technology Assessment) Ophthalmology 111 2004 1604 1617 (Pubitemid 39030819)
-
(2004)
Ophthalmology
, vol.111
, Issue.8
, pp. 1604-1617
-
-
Varley, G.A.1
Huang, D.2
Rapuano, C.J.3
Schallhorn, S.4
Boxer Wachler, B.S.5
Sugar, A.6
-
2
-
-
0036135669
-
Laser in situ keratomileusis for myopia and astigmatism: Safety and efficacy: A report by the American Academy of Ophthalmology
-
DOI 10.1016/S0161-6420(01)00966-6, PII S0161642001009666
-
A. Sugar, C.J. Rapuano, W.W. Culbertson, D. Huang, G.A. Varley, P.J. Agapitos, V.P. de Luise, and D.D. Koch Laser in situ keratomileusis for myopia and astigmatism: safety and efficacy; a report by the American Academy of Ophthalmology (Ophthalmic Technology Assessment) Ophthalmology 109 2002 175 187 (Pubitemid 34027444)
-
(2002)
Ophthalmology
, vol.109
, Issue.1
, pp. 175-187
-
-
Sugar, A.1
Rapuano, C.J.2
Culbertson, W.W.3
Huang, D.4
Varley, G.A.5
Agapitos, P.J.6
De Luise, V.P.7
Koch, D.D.8
-
3
-
-
0035132129
-
Pigmentary dispersion syndrome induced by a posterior chamber phakic refractive lens
-
DOI 10.1016/S0002-9394(00)00606-1, PII S0002939400006061
-
J.D. Brandt, M.E. Mockovak, and A. Chayet Pigmentary dispersion syndrome induced by a posterior chamber phakic refractive lens Am J Ophthalmol 131 2001 260 263 (Pubitemid 32157046)
-
(2001)
American Journal of Ophthalmology
, vol.131
, Issue.2
, pp. 260-263
-
-
Brandt, J.D.1
Mockovak, M.E.2
Chayet, A.3
-
4
-
-
0036929642
-
Malignant glaucoma induced by a phakic posterior chamber intraocular lens for myopia
-
DOI 10.1016/S0886-3350(02)01213-0, PII S0886335002012130
-
L. Kodjikian, P. Gain, D. Donate, F. Rouberol, and C. Burillon Malignant glaucoma induced by a phakic posterior chamber intraocular lens for myopia J Cataract Refract Surg 28 2002 2217 2221 (Pubitemid 36026102)
-
(2002)
Journal of Cataract and Refractive Surgery
, vol.28
, Issue.12
, pp. 2217-2221
-
-
Kodjikian, L.1
Gain, P.2
Donate, D.3
Rouberol, F.4
Burillon, C.5
-
5
-
-
0037239203
-
Cataract following posterior chamber phakic intraocular lens [2]
-
H.F. El-Sheikh, and K.F. Tabbara Cataract following posterior chamber phakic intraocular lens [letter] J Refract Surg 19 2003 72 73 (Pubitemid 36126032)
-
(2003)
Journal of Refractive Surgery
, vol.19
, Issue.1
, pp. 72-73
-
-
El-Sheikh, H.F.1
Tabbara, K.F.2
-
6
-
-
16544390827
-
Long-term complications of bilateral posterior chamber phakic intraocular lens implantation
-
DOI 10.1016/j.jcrs.2003.08.012, PII S0886335003008198
-
L. Mastropasqua, L. Toto, M. Nubile, G. Falconio, and M. Ciancaglini Long-term complications of bilateral posterior chamber phakic intraocular lens implantation J Cataract Refract Surg 30 2004 901 904 (Pubitemid 38501488)
-
(2004)
Journal of Cataract and Refractive Surgery
, vol.30
, Issue.4
, pp. 901-904
-
-
Mastropasqua, L.1
Toto, L.2
Nubile, M.3
Falconio, G.4
Ciancaglini, M.5
-
7
-
-
27444443816
-
Phakic intraocular lenses
-
DOI 10.1016/j.survophthal.2005.08.011, PII S0039625705001414
-
C.F. Lovisolo, and D.Z. Reinstein Phakic intraocular lenses Surv Ophthalmol 50 2005 549 587 (Pubitemid 41532322)
-
(2005)
Survey of Ophthalmology
, vol.50
, Issue.6
, pp. 549-587
-
-
Lovisolo, C.F.1
Reinstein, D.Z.2
-
8
-
-
0036857084
-
Incidence of lens opacities and clinically significant cataracts with the implantable contact lens: Comparison of two lens designs
-
D.R. Sanders, J.A. Vukich ICL in Treatment of Myopia (ITM) Study Group Incidence of lens opacities and clinically significant cataracts with the implantable contact lens: comparison of two lens designs J Refract Surg 18 2002 673 682 (Pubitemid 35429193)
-
(2002)
Journal of Refractive Surgery
, vol.18
, Issue.6
, pp. 673-682
-
-
Sanders, D.R.1
Vukich, J.A.2
Smith, D.3
-
9
-
-
0037312362
-
U.S. Food and Drug Administration clinical trial of the Implantable Contact Lens for moderate to high myopia
-
Implantable Contact Lens in Treatment of Myopia (ITM) Study Group
-
Implantable Contact Lens in Treatment of Myopia (ITM) Study Group U.S. Food and Drug Administration clinical trial of the Implantable Contact Lens for moderate to high myopia Ophthalmology 110 2003 255 266
-
(2003)
Ophthalmology
, vol.110
, pp. 255-266
-
-
-
10
-
-
40949138840
-
Correlation between ciliary sulcus diameter measured by 35 MHz ultrasound biomicroscopy and other ocular measurements
-
DOI 10.1016/j.jcrs.2007.11.034, PII S088633500800014X
-
K.-H. Kim, H.-H. Shin, H.-M. Kim, and J.-S. Song Correlation between ciliary sulcus diameter measured by 35 MHz ultrasound biomicroscopy and other ocular measurements J Cataract Refract Surg 34 2008 632 637 (Pubitemid 351417605)
-
(2008)
Journal of Cataract and Refractive Surgery
, vol.34
, Issue.4
, pp. 632-637
-
-
Kim, K.-H.1
Shin, H.-H.2
Kim, H.-M.3
Song, J.-S.4
-
11
-
-
60849115870
-
Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using Artemis VHF digital ultrasound
-
D.Z. Reinstein, T.J. Archer, R.H. Silverman, M.J. Rondeau, and D.J. Coleman Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using Artemis VHF digital ultrasound J Refract Surg 25 2009 185 194
-
(2009)
J Refract Surg
, vol.25
, pp. 185-194
-
-
Reinstein, D.Z.1
Archer, T.J.2
Silverman, R.H.3
Rondeau, M.J.4
Coleman, D.J.5
-
12
-
-
4444297974
-
Correlation between different measurements within the eye relative to phakic intraocular lens implantation
-
DOI 10.1016/j.jcrs.2003.10.041, PII S0886335004006479
-
L. Werner, A.M. Izak, S.K. Pandey, D.J. Apple, R.H. Trivedi, and J.M. Schmidbauer Correlation between different measurements within the eye relative to phakic intraocular lens implantation J Cataract Refract Surg 30 2004 1982 1988 (Pubitemid 39165933)
-
(2004)
Journal of Cataract and Refractive Surgery
, vol.30
, Issue.9
, pp. 1982-1988
-
-
Werner, L.1
Izak, A.M.2
Pandey, S.K.3
Apple, D.J.4
Trivedi, R.H.5
Schmidbauer, J.M.6
-
13
-
-
34548226462
-
Direct Measurement of the Ciliary Sulcus Diameter by 35-Megahertz Ultrasound Biomicroscopy
-
DOI 10.1016/j.ophtha.2006.12.018, PII S0161642006016678
-
J. Oh, H.-H. Shin, J.-H. Kim, H.-M. Kim, and J.-S. Song Direct measurement of the ciliary sulcus diameter by 35-megahertz ultrasound biomicroscopy Ophthalmology 114 2007 1685 1688 (Pubitemid 47332664)
-
(2007)
Ophthalmology
, vol.114
, Issue.9
, pp. 1685-1688
-
-
Oh, J.1
Shin, H.-H.2
Kim, J.-H.3
Kim, H.-M.4
Song, J.-S.5
-
14
-
-
0030976739
-
Age-related changes of the ciliary sulcus: Implications for implanting sulcus-fixated lenses
-
M. Blum, M.R. Tetz, U. Faller, and H.E. Völcker Age-related changes of the ciliary sulcus: implications for implanting sulcus-fixated lenses J Cataract Refract Surg 23 1997 91 96 (Pubitemid 27147583)
-
(1997)
Journal of Cataract and Refractive Surgery
, vol.23
, Issue.1
, pp. 91-96
-
-
Blum, M.1
Tetz, M.R.2
Faller, U.3
Volcker, H.E.4
-
16
-
-
4644258013
-
Very high frequency ultrasound biometry of the anterior and posterior chamber diameter
-
M.J. Rondeau, G. Barcsay, R.H. Silverman, D.Z. Reinstein, R. Krishnamurthy, A. Chabi, T. Du, and D.J. Coleman Very high frequency ultrasound biometry of the anterior and posterior chamber diameter J Refract Surg 20 2004 454 464 (Pubitemid 39299540)
-
(2004)
Journal of Refractive Surgery
, vol.20
, Issue.5
, pp. 454-464
-
-
Rondeau, M.J.1
Barcsay, G.2
Silverman, R.H.3
Reinstein, D.Z.4
Krishnamurthy, R.5
Chabi, A.6
Du, T.7
Coleman, D.J.8
-
17
-
-
0037224829
-
Ultrasound biomicroscopy examination of posterior chamber phakic intraocular lens position
-
DOI 10.1016/S0161-6420(02)01449-5, PII S0161642002014495
-
J. García-Feijoó, I. Jiménez Alfaro, R. Cuiña-Sardiña, C. Méndez-Hernandez, J.M. Benítez del Castillo, and J. García-Sánchez Ultrasound biomicroscopy examination of posterior chamber phakic intraocular lens position Ophthalmology 110 2003 163 172 (Pubitemid 36068742)
-
(2003)
Ophthalmology
, vol.110
, Issue.1
, pp. 163-172
-
-
Garcia-Feijoo, J.1
Jimenez Alfaro, I.2
Cuina-Sardina, R.3
Mendez-Hernandez, C.4
Benitez Del Castillo, J.M.5
Garcia-Sanchez, J.6
-
18
-
-
33845902546
-
Toric Implantable Collamer Lens for Moderate to High Myopic Astigmatism
-
DOI 10.1016/j.ophtha.2006.08.049, PII S0161642006013145
-
D.R. Sanders, D. Schneider, R. Martin, D. Brown, D. Dulaney, J. Vukich, S. Slade, and S. Schallhorn Toric Implantable Collamer Lens for moderate to high myopic astigmatism Ophthalmology 114 2007 54 61 (Pubitemid 46019883)
-
(2007)
Ophthalmology
, vol.114
, Issue.1
, pp. 54-61
-
-
Sanders, D.R.1
Schneider, D.2
Martin, R.3
Brown, D.4
Dulaney, D.5
Vukich, J.6
Slade, S.7
Schallhorn, S.8
-
19
-
-
33751023087
-
Magnetic resonance imaging of aging, accommodating, phakic, and pseudophakic ciliary muscle diameters
-
DOI 10.1016/j.jcrs.2006.05.031, PII S0886335006010418
-
S.A. Strenk, L.M. Strenk, and S. Guo Magnetic resonance imaging of aging, accommodating, phakic, and pseudophakic ciliary muscle diameters J Cataract Refract Surg 32 2006 1792 1798 (Pubitemid 44754916)
-
(2006)
Journal of Cataract and Refractive Surgery
, vol.32
, Issue.11
, pp. 1792-1798
-
-
Strenk, S.A.1
Strenk, L.M.2
Guo, S.3
-
20
-
-
0032924928
-
Age-related changes in human ciliary muscle and lens: A magnetic resonance imaging study
-
S.A. Strenk, J.L. Semmlow, L.M. Strenk, P. Munoz, J. Gronlund-Jacob, and J.K. DeMarco Age-related changes in human ciliary muscle and lens: a magnetic resonance imaging study Invest Ophthalmol Vis Sci 40 1999 1162 1169 Available at: http://www.iovs.org/cgi/reprint/40/6/1162 Accessed April 19, 2011 (Pubitemid 29211453)
-
(1999)
Investigative Ophthalmology and Visual Science
, vol.40
, Issue.6
, pp. 1162-1169
-
-
Strenk, S.A.1
Semmlow, J.L.2
Strenk, L.M.3
Munoz, P.4
Gronlund-Jacob, J.5
DeMarco, J.K.6
-
21
-
-
27144530645
-
Magnetic resonance imaging and Orbscan assessment of the anterior chamber
-
DOI 10.1016/j.jcrs.2005.02.040, PII S0886335005004256
-
A.M. Fea, F. Annetta, S. Cirillo, D. Campanella, M. De Giuseppe, D. Regge, and F.M. Grignolo Magnetic resonance imaging and Orbscan assessment of the anterior chamber J Cataract Refract Surg 31 2005 1713 1718 (Pubitemid 41503426)
-
(2005)
Journal of Cataract and Refractive Surgery
, vol.31
, Issue.9
, pp. 1713-1718
-
-
Fea, A.M.1
Annetta, F.2
Cirillo, S.3
Campanella, D.4
De Giuseppe, M.5
Regge, D.6
Grignolo, F.M.7
-
22
-
-
0034907871
-
Predicting sulcus size using ocular measurements
-
DOI 10.1016/S0886-3350(00)00830-0, PII S0886335001008300
-
M. Pop, Y. Payette, and M. Mansour Predicting sulcus size using ocular measurements J Cataract Refract Surg 27 2001 1033 1038 (Pubitemid 32734153)
-
(2001)
Journal of Cataract and Refractive Surgery
, vol.27
, Issue.7
, pp. 1033-1038
-
-
Pop, M.1
Payette, Y.2
Mansour, M.3
-
23
-
-
77950287220
-
Relationship between ciliary sulcus diameter and anterior chamber diameter and corneal diameter
-
T. Kawamorita, H. Uozato, K. Kamiya, and K. Shimizu Relationship between ciliary sulcus diameter and anterior chamber diameter and corneal diameter J Cataract Refract Surg 36 2010 617 624
-
(2010)
J Cataract Refract Surg
, vol.36
, pp. 617-624
-
-
Kawamorita, T.1
Uozato, H.2
Kamiya, K.3
Shimizu, K.4
|