메뉴 건너뛰기




Volumn 36, Issue 4, 2010, Pages 617-624

Relationship between ciliary sulcus diameter and anterior chamber diameter and corneal diameter

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANTERIOR EYE CHAMBER; ARTICLE; BIOMICROSCOPY; CILIARY BODY; CILIARY SULCUS; CORNEA; HUMAN; PRIORITY JOURNAL; SCANNING SLIT TOPOGRAPHY; VISUAL SYSTEM EXAMINATION;

EID: 77950287220     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2009.11.017     Document Type: Article
Times cited : (47)

References (17)
  • 3
    • 34247277737 scopus 로고    scopus 로고
    • Ultrasound biomicroscopy for determining Visian implantable contact lens length in phakic IOL implantation
    • Choi K.H., Chung S.E., Chung T.Y., and Chung E.S. Ultrasound biomicroscopy for determining Visian implantable contact lens length in phakic IOL implantation. J Refract Surg 23 (2007) 362-367
    • (2007) J Refract Surg , vol.23 , pp. 362-367
    • Choi, K.H.1    Chung, S.E.2    Chung, T.Y.3    Chung, E.S.4
  • 5
    • 34548226462 scopus 로고    scopus 로고
    • Direct measurement of the ciliary sulcus diameter by 35-megahertz ultrasound biomicroscopy
    • Oh J., Shin H.-H., Kim J.-H., Kim H.-M., and Song J.-S. Direct measurement of the ciliary sulcus diameter by 35-megahertz ultrasound biomicroscopy. Ophthalmology 114 (2007) 1685-1688
    • (2007) Ophthalmology , vol.114 , pp. 1685-1688
    • Oh, J.1    Shin, H.-H.2    Kim, J.-H.3    Kim, H.-M.4    Song, J.-S.5
  • 6
    • 0034907871 scopus 로고    scopus 로고
    • Predicting sulcus size using ocular measurements
    • Pop M., Payette Y., and Mansour M. Predicting sulcus size using ocular measurements. J Cataract Refract Surg 27 (2001) 1033-1038
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1033-1038
    • Pop, M.1    Payette, Y.2    Mansour, M.3
  • 7
    • 4444297974 scopus 로고    scopus 로고
    • Correlation between different measurements within the eye relative to phakic intraocular lens implantation
    • Werner L., Izak A.M., Pandey S.K., Apple D.J., Trivedi R.H., and Schmidbauer J.M. Correlation between different measurements within the eye relative to phakic intraocular lens implantation. J Cataract Refract Surg 30 (2004) 1982-1988
    • (2004) J Cataract Refract Surg , vol.30 , pp. 1982-1988
    • Werner, L.1    Izak, A.M.2    Pandey, S.K.3    Apple, D.J.4    Trivedi, R.H.5    Schmidbauer, J.M.6
  • 8
    • 40949138840 scopus 로고    scopus 로고
    • Correlation between ciliary sulcus diameter measured by 35 MHz ultrasound biomicroscopy and other ocular measurements
    • Kim K.-H., Shin H.-H., Kim H.-M., and Song J.-S. Correlation between ciliary sulcus diameter measured by 35 MHz ultrasound biomicroscopy and other ocular measurements. J Cataract Refract Surg 34 (2008) 632-637
    • (2008) J Cataract Refract Surg , vol.34 , pp. 632-637
    • Kim, K.-H.1    Shin, H.-H.2    Kim, H.-M.3    Song, J.-S.4
  • 9
    • 0000135659 scopus 로고    scopus 로고
    • Forming inferences about some intraclass correlation coefficients
    • Accessed December 29, 2009
    • McGraw K.O., and Wond S.P. Forming inferences about some intraclass correlation coefficients. Psychol Meth 1 (1996) 30-46. http://www3.uta.edu/faculty/ricard/COED/McGraw%20(1996)%20Forming%20infe rences%20about%20ICCs.pdf Accessed December 29, 2009
    • (1996) Psychol Meth , vol.1 , pp. 30-46
    • McGraw, K.O.1    Wond, S.P.2
  • 11
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Accessed December 29, 2009
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310. Available at: http://www-users.york.ac.uk/∼mb55/meas/ba.pdf Accessed December 29, 2009
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 37449000474 scopus 로고    scopus 로고
    • Corneal diameter measurements by corneal topography and angle-to-angle measurements by optical coherence tomography: evaluation of equivalence
    • Piñero D.P., Plaza Puche A.B., and Alió J.L. Corneal diameter measurements by corneal topography and angle-to-angle measurements by optical coherence tomography: evaluation of equivalence. J Cataract Refract Surg 34 (2008) 126-131
    • (2008) J Cataract Refract Surg , vol.34 , pp. 126-131
    • Piñero, D.P.1    Plaza Puche, A.B.2    Alió, J.L.3
  • 13
    • 60849115870 scopus 로고    scopus 로고
    • Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using Artemis VHF digital ultrasound
    • Reinstein D.Z., Archer T.J., Silverman R.H., Rondeau M.J., and Coleman D.J. Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using Artemis VHF digital ultrasound. J Refract Surg 25 (2009) 185-194
    • (2009) J Refract Surg , vol.25 , pp. 185-194
    • Reinstein, D.Z.1    Archer, T.J.2    Silverman, R.H.3    Rondeau, M.J.4    Coleman, D.J.5
  • 15
    • 33750479829 scopus 로고    scopus 로고
    • Internal anterior chamber diameter using optical coherence tomography compared with white-to-white distances using automated measurements
    • Kohnen T., Thomala M.C., Cichocki M., and Strenger A. Internal anterior chamber diameter using optical coherence tomography compared with white-to-white distances using automated measurements. J Cataract Refract Surg 32 (2006) 1809-1813
    • (2006) J Cataract Refract Surg , vol.32 , pp. 1809-1813
    • Kohnen, T.1    Thomala, M.C.2    Cichocki, M.3    Strenger, A.4
  • 16
    • 0036981586 scopus 로고    scopus 로고
    • White-to-white corneal diameter measurements using the Eyemetrics program of the Orbscan topography system
    • Wang L., and Auffarth G.U. White-to-white corneal diameter measurements using the Eyemetrics program of the Orbscan topography system. Dev Ophthalmol 34 (2002) 141-146
    • (2002) Dev Ophthalmol , vol.34 , pp. 141-146
    • Wang, L.1    Auffarth, G.U.2
  • 17
    • 63449134268 scopus 로고    scopus 로고
    • Factors affecting the vaulting after Implantable Collamer Lens implantation
    • Kamiya K., Shimizu K., and Komatsu M. Factors affecting the vaulting after Implantable Collamer Lens implantation. J Refract Surg 25 (2009) 259-264
    • (2009) J Refract Surg , vol.25 , pp. 259-264
    • Kamiya, K.1    Shimizu, K.2    Komatsu, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.