메뉴 건너뛰기




Volumn , Issue , 2011, Pages 984-989

Analytical study of high pulse current shunts

Author keywords

[No Author keywords available]

Indexed keywords

ELECTROMAGNETIC RAILS; GEOMETRICAL PARAMETERS; MEASUREMENT CIRCUIT; MUTUAL INDUCTANCE; PULSE CURRENTS; SQUIRREL-CAGE;

EID: 80051882156     PISSN: 10915281     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IMTC.2011.5944280     Document Type: Conference Paper
Times cited : (8)

References (16)
  • 1
    • 0033361305 scopus 로고    scopus 로고
    • The flat strap sandwhich shunt
    • May
    • F. Castelli, "The flat strap sandwhich shunt," IEEE Trans. Instrum. Meas., vol. 48, no. 5, May 1999, p. 894-898.
    • (1999) IEEE Trans. Instrum. Meas. , vol.48 , Issue.5 , pp. 894-898
    • Castelli, F.1
  • 3
    • 78651281606 scopus 로고    scopus 로고
    • Critical Parameters for Mutual Inductance between Rogowski Coil and Primary Conductor
    • Feb.
    • M. Marracci, B. Tellini, C. Zappacosta, G. Robles, "Critical Parameters for Mutual Inductance Between Rogowski Coil and Primary Conductor," IEEE Trans. Instrum. Meas., vol. 60, no. 2, Feb. 2011, p. 625-632.
    • (2011) IEEE Trans. Instrum. Meas. , vol.60 , Issue.2 , pp. 625-632
    • Marracci, M.1    Tellini, B.2    Zappacosta, C.3    Robles, G.4
  • 5
    • 33846315481 scopus 로고    scopus 로고
    • Highly Local Measurements of Strong Transient Magnetic Fields during Railgun Experiments Using CMR-Based Sensors
    • Jan.
    • M. Schneider, R. Schneider, V. Stankević, S. Balevičius, and N. Žurauskienė, "Highly Local Measurements of Strong Transient Magnetic Fields During Railgun Experiments Using CMR-Based Sensors," IEEE Trans. Magn., vol. 43, no. 1, Jan. 2007, p. 370-375.
    • (2007) IEEE Trans. Magn. , vol.43 , Issue.1 , pp. 370-375
    • Schneider, M.1    Schneider, R.2    Stankevič, V.3    Balevičius, S.4    Žurauskiene, N.5
  • 7
    • 48749130287 scopus 로고    scopus 로고
    • 20-A to 100-A AC-DC Coaxial Current Shunts for 100-kHz Frequency Range
    • Aug.
    • P. S. Filipski, M. Boecker, M. Garcocz, "20-A to 100-A AC-DC Coaxial Current Shunts for 100-kHz Frequency Range," IEEE Trans. Instrum. Meas., vol. 57, no. 8, Aug. 2008, p. 1637-1641.
    • (2008) IEEE Trans. Instrum. Meas. , vol.57 , Issue.8 , pp. 1637-1641
    • Filipski, P.S.1    Boecker, M.2    Garcocz, M.3
  • 8
    • 0030107730 scopus 로고    scopus 로고
    • Coaxial shunt intended for transient current measurement in a pseudospark switch
    • March
    • P. Moran, A. Gilbert, G. J. Francois, P. Pignolet, "Coaxial shunt intended for transient current measurement in a pseudospark switch," it IEE Proc. Sc. Meas. Technol., vol. 143, no. 2, March 1996, p. 119-124.
    • (1996) IEE Proc. Sc. Meas. Technol. , vol.143 , Issue.2 , pp. 119-124
    • Moran, P.1    Gilbert, A.2    Francois, G.J.3    Pignolet, P.4
  • 9
    • 34848894539 scopus 로고    scopus 로고
    • Recent Developments on High Current Measurement Using Current Shunt
    • Sept.
    • T. Kawamura, E. Haginomori, Y. Goda, T. Nakamoto, "Recent Developments on High Current Measurement Using Current Shunt," IEEJ Trans., vol. 2, no. 5, Sept. 2007, p. 516-522.
    • (2007) IEEJ Trans. , vol.2 , Issue.5 , pp. 516-522
    • Kawamura, T.1    Haginomori, E.2    Goda, Y.3    Nakamoto, T.4
  • 10
    • 0038196455 scopus 로고
    • Stress sensitivity of manganin resistor in high-current precision coaxial shunt
    • Dec.
    • W. F. Praeg, "Stress sensitivity of manganin resistor in high-current precision coaxial shunt," IEEE Trans. Instrum. Meas., vol. IM-15, no. 4, Dec. 1966, p. 234-242.
    • (1966) IEEE Trans. Instrum. Meas. , vol.IM-15 , Issue.4 , pp. 234-242
    • Praeg, W.F.1
  • 11
    • 0020715788 scopus 로고
    • Instrumentation for EM launcher systems
    • Mar.
    • K. Nalty, R. Zowarka, L. Holland, "Instrumentation for EM launcher systems," IEEE Trans. Magn., vol. 20, no. 2, Mar. 1984, p. 328-331.
    • (1984) IEEE Trans. Magn. , vol.20 , Issue.2 , pp. 328-331
    • Nalty, K.1    Zowarka, R.2    Holland, L.3
  • 12
    • 0019559270 scopus 로고
    • A Novel Principle of Distortionless Measurement of Current Impulse
    • Apr.
    • C. T. Nguyen, R. Malewski, "A Novel Principle of Distortionless Measurement of Current Impulse," Proc. of IEEE, vol. 69, no. 4, Apr. 1981, p. 490-491.
    • (1981) Proc. of IEEE , vol.69 , Issue.4 , pp. 490-491
    • Nguyen, C.T.1    Malewski, R.2
  • 14
    • 0028549505 scopus 로고
    • Current measurement using compensated coaxial shunts
    • Nov.
    • C. M. Johnson, P.R. Palmer, "Current measurement using compensated coaxial shunts," IEE Proc. Sc. Meas. Tech., vol. 141, no. 6, Nov. 1994, p. 471-480.
    • (1994) IEE Proc. Sc. Meas. Tech. , vol.141 , Issue.6 , pp. 471-480
    • Johnson, C.M.1    Palmer, P.R.2
  • 16
    • 79953767744 scopus 로고    scopus 로고
    • Characterization of Inductance Gradient and Current Distribution in Electromagnetic Launchers
    • in press on IEEE Trans. Instrum. Meas., doi:10.1109/TIM.2010.2091186
    • R. Ferrero, M. Marracci, B. Tellini, "Characterization of Inductance Gradient and Current Distribution in Electromagnetic Launchers," IEEE Trans. Instrum. Meas., in press on IEEE Trans. Instrum. Meas., doi:10.1109/TIM.2010.2091186.
    • IEEE Trans. Instrum. Meas.
    • Ferrero, R.1    Marracci, M.2    Tellini, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.